DEFLAGRATION FIRE MARSHAL PMAX WOOD

Similar documents
Combustible Dusts. Some recent examples of dust explosion losses in the U.S. include:

Grain Dust Explosions (59 dead, 49 injured since 1976)

DUST COLLECTORS AND POTENTIALLY EXPLOSIVE ATMOSPHERES NOTIFIED BODY NOTIFIED BODY NOTIFIED BODY

HAFCOVAC. COMBUSTIBLE DUST Understanding How To Prevent Industrial Fire Hazards. Solid Leadership In Industrial Safety

Bulwark Training. Combustible Dust: Understanding the Basics

OUTDOOR INSTALL NO RETURN AIR SINGLE MODULE COLLECTORS OUTDOOR INSTALL WITH RETURN AIR SINGLE MODULE COLLECTORS

Combustible Dust Hazards- Awareness

Combustible Dust 101: Understanding Combustible Dust Hazards

Combustible Dust Issues

Combustible Dust Hazard Recognition and Control NFPA Standards for Combustible Dusts

COMBUSTIBLE DUST SAFETY PROGRAM

administered by RC12: Recommendations for the prevention and control of dust explosions

LP BAGHOUSE DUST COLLECTORS

Conducting a NFPA 652 Dust Hazard Analysis (DHA): Practical Tips & Approaches

Leading Trends in Chemical Processing

MESSER DUST COLLECTORS Models 2-8 through 4-128

Aluminum Dust Management in a Metallizing Facility

Jason Reason. NFPA Technical Committees

Property risk solutions

Objectives. NFPA Dust Specific Documents. Combustible Dust Process Hazard Safety Overview of NFPA Standards for Combustible Dusts

With CV Technology products and care, you ll be better protected from dust explosions.

Understanding. Combustible Dust Hazards: Basic Measures to Ensure the Safety of Combustible Dust Handling Operations

Combustible Dust Awareness. David McEwan Business Line Manager Configured Products

Industrial Explosion Suppression Technology

Protecting Critical Facilities Against Explosions

Dust Explosions. health & environmental sciences failure analysis & prevention

OSHA - Enforcement Define the terminology Recognize a Dust Explosion hazard Learn hazard management methods

DUST COLLECTION TRAINING. Revision 2013

Prevention of Fires and Explosions in Wood Pellet Facilities. Allen Wagoner, FLAMEX, Inc.

COMBUSTIBLE DUST HAZARD MITIGATION

Special Occupancy Requirements

Dust Explosion Hazard Overview

Protecting Facilities Against Explosions. Since 1956

Managing Combustible Dust

PRIMATECH WHITE PAPER PROCEDURE FOR DUST HAZARD ANALYSIS (DHA)

3/20/2017. The Impact & Implications of NFPA 652 NFPA s Newest Combustible Dust Standard. Jason Reason. Jason Reason

Progressive Safety Services LLC 1

INTRODUCTION TO DUSTS AND THEIR EXPLOSIVE PROPERTIES

Industrial Dust Explosions Causes & Case Studies. Presented by Geof Brazier at Expocorma, Concepcion, Chile 10th November 2017

GEAPS Great Lakes Regional Conference 2017 Explosion Protection Overview & Market Drivers. April 6, 2017

A Global Leader in Explosion Protection

Implementing a Combustible Dust Program. Presented by: Nick Miedema Amway EH&S For: Michigan Safety Conference

Before proceeding with the selection process, let s briefly look at the various explosion protection options:

Dust Collection Tips to Keep Free-From Foods Safe from Cross-Contamination

1NFPA 68 has changed from a guideline to a

COMBUSTIBLE DUST HAZARD RECOGNITION

Combustible Dust Resources OVERVIEW OF COMBUSTIBLE DUST. What is Combustible Dust? Where are Combustible Dusts found?

Combustible Dust Booklet

Explosion-proof Duct Heaters

WHITE PAPER Dust Hazard Analysis for Simple Dust Collection Systems

This Second Correlating Revision effects correct usage. This also addresses one of the Affirmative Comments to Second Revision No. 28.

Ontario Fire Code SECTION 5.10 COMBUSTIBLE DUST PRODUCING PROCESSES. Illustrated Commentary. Office of the Ontario Fire Marshal

We ve all heard about catastrophic combustible

Preventing and Mitigating Combustible Dust Fires and Explosions

There are always options in the management of explosion risks!

First Revision No. 15-NFPA [ Chapter 2 ]

EVOLUTION DUST COLLECTORS FOR MIST INDUSTRIES

Plant Issues in an NFPA 652 Dust Hazard Analysis

Guide - Basic Information

AUTOMATIC FIRE SUPPRESSION SYSTEMS

Combustible Dust with FR Clothing June Service Experience Trust Quality Flexibility

Combustible Wood Dust Management Program Development Guide

Compliance Guidance for non-technical managers

4/6/2018. Merrill Childs Cargill Eddyville, IA Iowa-Illinois Safety Council Coralville, IA April 12, 2018

Managing explosive dust risk in sugar handling

Explosion prevention and explosion protection according to ATEX guidelines. Safe extraction and separation of explosive dust

First Revision No. 1-NFPA [ Chapter 2 ]

Combustible Dust Hazards- Awareness

Fire Prevention Plan Program

Pepperl+Fuchs Class II Solutions

Overview of Hazardous Locations as They Relate to Solenoid Valves

Clean. Easy. COMPLIANT.

BUILDING/FIRE CODE REFERENCES 2006 EDITION

Safe installations are also cost effective installations

Soot Mitigation Strategies

Flameless Venting The New Technology for Safe Indoor Explosion Venting

Dust Hazard Assessments

Meeting NFPA standards for

Laboratories and Hazardous Materials. Company Overview

Identifying and Preventing Dust Fire and Explosion Hazards

Explosion prevention and explosion protection according to ATEX guidelines. Safe extraction and separation of explosive dust

Fire Alarm System Accessories

The element is closed at one end and open at the other, and it s bolted onto the explosion vent opening on the equipment so that its open end overlaps

DUST EXPLOSION CODES AND STANDARDS: Ensuring Regional Compliance and Global Consistency

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

ADDITIONS TO NFPA 61, STANDARD FOR THE PREVENTION OF FIRES AND DUST EXPLOSIONS IN THE AGRICULTURAL AND FOOD PROCESSING INDUSTRIES

DALAMATIC DUST COLLECTORS

Savard Labor & Marine Staffing, Inc. Fire Prevention Program Rev3/14

Explosion Venting and Suppression of Bucket Elevator Legs, G90-990

The correlating committee has revised the numbering in these sections to provide clarity for the next edition of the document.

AQ Translated English of Chinese Standard: AQ WORK SAFETY INDUSTRY STANDARD

CLEACOM Engineered System Solutions. Established 24/7 technology for the separation of dust and fume during compounding processes

Making sense of risk Risk engineering. Metalworking operations

Kice Dust Control System Design and Maintenance Basics Design, Maintenance, & Operation

PRELIMINARY REVIEW OF APPLICABLE CODES AND STANDARDS, PROCESS HAZARD ANALYSIS AND OPERATIONAL FIRE SAFETY PLAN

GHS Dust Explosion Guidance. ANNEX 11 Guidance on other hazards not resulting in classification. September 2017

THE PACESETTER IN EXPLOSION SAFETY INNOVATION EXPLOSION PROTECTION SOLUTIONS YOU CAN COUNT ON WORLDWIDE.

Introduction Airflow and filtration area General design practices Cleaning system

GENERAL FIRE REQUIREMENTS SELF INSPECTION CHECKLIST

Reducing the Cost and Risk of Dust Collection in Coal

Transcription:

DUST COLLECTORS & COMBUSTIBLE DUST STRATEGIES FACTORY MUTUAL X-VENT DUCTS AHJ TESTING BUILDING INSPECTOR NFPA68,91,654 CSB FIRE PROTECTION FACTORY MUTUAL X-VENT DUCTS AHJ TESTING BUILDING INSPECTOR NFPA68,91,654 CSB FIRE PROTECTION BUILDING INSPECTOR NFPA68,91,654 CSB FIRE PROTECTION BUILDING INSPECTOR NFPA68,91,654 CSB FIRE PROTECTION FACTORY MUTUAL X-VENT DUCTS AHJ TESTING

INTRODUCTION TO COMBUSTIBLE DUST The U.S. Occupational Safety and Health Administration (OSHA) has issued a National Emphasis Program and continues to communicate with most industries on the hazards of combustible dust. The agency's focused effort is targeted at reducing combustible dust risks in industrial plant settings. Is your plant effectively managing the risks associated with combustible dust in its processes? For decades Donaldson Torit has been providing quality dust collectors that have become an integral part of many plant s combustible dust compliance strategies. Donaldson remains active in supplying dust collectors to support your combustible dust control strategy by interfacing with you and your experts on fire and explosion protection equipment and strategies. This document is intended to increase your understanding of typical combustible dust management strategies and some of the components involved. WHERE TO START? A Donaldson Torit representative can review your operational challenges to help you better understand how to integrate dust collection into your combustible dust management strategy. The following considerations are designed to help you decide how you want Donaldson Torit to support your combustible dust management strategy: DO YOU HAVE COMBUSTIBLE MATERIALS?* ARE THERE SPARKS? HAS THE PROCESS EXPERIENCED FIRES? DO YOU HAVE TEST RESULTS CONFIRMING COMBUSTIBLE MATERIALS? Obtain test data on combustible properties K st, P max, MIE, MEC. DO TEST RESULTS CONFIRM COMBUSTIBLE MATERIALS? MATERIALS MAY T BE COMBUSTIBLE. GET VERIFICATION OF MATERIAL PROPERTIES. OPTIONS FOR COMBUSTIBLE MATERIALS MAY T BE NECESSARY FOR YOUR COLLECTOR. Collector selections could be made without options for combustible material risk management. DO YOU WANT DONALDSON TORIT TO INCLUDE OPTIONS TO SUPPORT YOUR COMBUSTIBLE MATERIALS MANAGEMENT STRATEGIES? Options for your combustible material risks management strategies are provided by others. DOCUMENTED PROCESS HAZARD ASSESSMENT MAY SUGGEST OPTIONS TO CONSIDER DURING COLLECTOR SELECTION. Donaldson Torit will include options to support your combustible material risk management strategies. Additional options may be provided by others. 1 Donaldson Torit * See the partial list from OSHA on page 6

COMPLIANCE STRATEGY COMPONENTS * DUST CONTROL PROTECTION FIRE TRIANGLE Fire management strategies traditionally focus on the control or elimination of one of the three key elements necessary for a fire often represented by the fire triangle." Managing one or more of the elements in the triangle can decrease the fire risk. PREVENTION IGNITION CONTROL UNDERSTANDING THE BASICS Many manufacturing processes create very small particles of dust which may become airborne, where they settle on surfaces and in crevices throughout the plant. Eventually these particles not only create a housekeeping issue, but if the particles are combustible, they can represent a potentially explosive dust cloud if disturbed. It is essential for plant leaders to understand the risks of combustible dust and ensure they manage combustible dusts in their facilities. Donaldson Torit can supply dust collectors to support your combustible dust control strategy by interfacing with you and your experts on fire and explosion protection equipment and solutions. Combustible dusts generally present both fire and explosion risks so it may help to consider the management of these risks separately (see side bar). WHY DUST COLLECTORS SHOULD BE PART OF YOUR STRATEGY DECISION Many process requirements may make elimination of combustible dust, mist, or fume impractical. However, it may still be very possible to manage the dispersion of dust within your plant by using an appropriate and effective industrial ventilation system including dust collection. A well designed, maintained, and operated industrial ventilation system including good hoods, proper duct sizes, and properly selected collection equipment can provide effective dust control and can therefore help manage the presence of dispersed dust. This not only reduces housekeeping frequency and expense, but could also help you reduce the risk of dust explosions in your facility, particularly the destructive secondary explosions, by helping reduce the presence of dispersed fuel in your facility. * For more information, please see page 6. FIRE TRIANGLE EXPLOSION PENTAGON Explosion risk management strategies consider a slightly expanded set of elements often represented as an explosion pentagon. In addition to the key elements from the fire triangle fuel, heat, and oxygen, the explosion pentagon includes two additional elements necessary for an explosion: Dispersion of Dust and Confinement of Dust. As with fire management strategies, the management or removal of one or more of the elements in the explosion pentagon can reduce the explosion risk. While many explosion management strategies focus on controlling the same elements in the fire triangle, explosion risk management strategies that focus on the dispersion of dust, or the containment of dust alone, may require a separate strategy to address any remaining fire risks. Oxygen/Air Dispersion of Dust Confinement of Dust DUST EXPLOSION Combustible Dust/Fume To be compliant with OSHA regulations, you must meet other requirements and all applicable standards or codes. Visit www.osha.gov to find OSHA regulations. Ignition Source donaldsontorit.com 800-365-1331 2

GUIDE TO EXPLOSION/FIRE PROTECTION COMPONENTS FOR DUST COLLECTIONS ITEM # DESCRIPTION 1 Explosion Relief Panels 2 Detector / Sensor Chemical or Actuated System Devices 3 Chemical Suppressant Delivery Device 4 Suppression System Control Panel 5 Fire Extinguisher/Fire Suppression/Sprinkler Coupling 6 Overflow Drain 7 Rotary Valve/ Airlock 8 Flow Actuated Isolation Valve - Inlet OUTLET 9 In-line Spark Abatement 10 Spark Detection & Extinguishing System 11 Actuated Knife Gate - Inlet 12 Chemical Isolation Device - Inlet 13 Automatic Fast Acting Abort Gate 14 Actuated Knife Gate - Outlet 15 Flow Actuated Isolation Valve - Outlet 16 Chemical Isolation Device - Outlet INLET INLET OPTIONS 3 Donaldson Torit

Some Components in Risk Management Strategies for: Item # EXPLOSION FIRE FIRE PROTECTION Fire Extinguisher/ Fire Suppression / Sprinkler Coupling 5 Overflow Drain 6 Automatic Fast Acting Abort Gate 13 In-line Spark Abatement 9 Spark Detection & Extinguishing System 10 EXPLOSION PROTECTION MECHANICAL Explosion Relief Panels 1 CHEMICAL Chemical Suppressant Delivery Device 3 Suppression System Control Panel 4 Detector / Sensor Chemical or Actuated System Devices 2 DUST COLLECTOR ISOLATION INLET MECHANICAL Actuated Knife Gate Inlet 11 Flow Actuated Isolation Valve Inlet 8 CHEMICAL Chemical Isolation Device Inlet 12 Suppression System Control Panel 4 Detector / Sensor Chemical or Actuated System Devices 2 HOPPER Rotary Valve/ Airlock 7 OUTLET (IF AIR IS RETURNED TO THE BUILDING) MECHANICAL Actuated Knife Gate Outlet 14 Flow Actuated Isolation Valve Outlet 15 CHEMICAL Chemical Isolation Device Outlet 16 Suppression System Control Panel 4 Detector / Sensor Chemical or Actuated System Devices 2 OUTLET OPTIONS donaldsontorit.com 800-365-1331 4

As a process owner, you are responsible for the selection of your combustible material management strategy and to assure compliance with all applicable federal, state, and local codes and standards. DEFINITIONS Authority Having Jurisdiction (AHJ): An organization, office, or individual responsible for enforcing the requirements of a code or standard, or for approving equipment, materials, an installation, or a procedure A v (Vent Area): Calculated from P red, container volume, K st, P max and P stat Combustible Dust: A combustible particulate solid that presents a fire or deflagration hazard when suspended in air or some other oxidizing medium over a range of concentrations, regardless of particle size or shape Deflagration: Propagation of a combustion zone at a velocity that is less than the speed of sound in the unreacted medium Detonation: Propagation of a combustion zone at a velocity that is greater than the speed of sound in the unreacted medium Explosion: The bursting or rupturing of an enclosure or container due to the development of internal pressure from a deflagration K st (Deflagration Index for Dust): The maximum rate of pressure rise during a contained deflagration of an optimum mixture Millisecond (msec): 1,000th of a second (Time for light to travel: 300km in a vacuum=1 msec, Honeybee wing flap= 5 msec, Reaction speed of a human= 100 msec, Blink of a human eye= 300-400 msec) P max (Maximum Pressure): The maximum pressure developed in a contained deflagration of an optimum mixture P red (Reduced Pressure): The calculated maximum pressure developed in a vented enclosure during a vented deflagration P stat (Static Activation Pressure): The pressure that activates a vent closure when the pressure is increase slowly (with a rate of pressure rise less than 0.1 bar/min) TSP (Total Suppressed Pressure): Pressure in an enclosure after a suppressed event NFPA 652 NFPA 654 NFPA 68 NFPA 69 NFPA 91 NFPA 61 NFPA 484 NFPA 664 NFPA 33 Short list of NFPA Design Standards with associated visual images to reinforce the topic covered by the standard. Standard on the Fundamentals of Combustible Dust Standard for the Prevention of Fire and Dust Explosions from the Manufacturing, Processing, and Handling of Combustible Particulate Solids Standard for Explosion Protection by Deflagration Venting Standard on Explosion Prevention Systems Standard for Exhaust Systems for Air Conveying of Vapors, Gases, Mists, and Noncombustible Particulate Solids Standard for the Prevention of Fires and Dust Explosions in Agricultural and Food Processing Facilities Standard for Combustible Metals Standard for Prevention of Fires and Explosions in Wood Processing and Woodworking Facilities Standard for Spray Applications Using Flammable or Combustible Materials STANDARDS, CODES, & GUIDELINES THAT IMPACT DUST COLLECTOR DECISIONS Many standards and codes may influence your decisions on dust control, including local, state, and federal regulations. Knowing the codes that apply to your facility is critical, and you should always research the code requirements in your area. A few commonly referenced standards for combustible dust risk management strategies include those issued by: National Fire Protection Association (NFPA), the International Mechanical Code, the International Fire Code, Factory Mutual Property Loss, and OSHA (federal). Since each Authority Having Jurisdiction may have a specific set of codes it references, you may need to have general knowledge of more than one standard or code. Some of the most commonly referenced standards are published by NFPA, including both design and operational standards focused on combustible dust (see above). Since these standards are often referenced by OSHA, and have been adopted as code in many areas of the country, they may be a good starting point for consideration in developing your combustible dust management strategy. 5 Donaldson Torit Visit www.nfpa.org for more information.

Does your company or firm process any of these products or materials in powdered form? See side bar. ** If so, there is potential for a Combustible Dust explosion. Dust Control Measures The dust-containing systems (ducts and dust collectors) are designed in a manner (i.e., no leaking) that fugitive dusts are not allowed to accumulate in the work area. The facility has a housekeeping program with regular cleaning frequencies established for floors and horizontal surfaces, such as ducts, pipes, hoods, ledges, and beams, to minimize dust accumulations within operating areas of the facility. The working surfaces are designed in a manner to minimize dust accumulation and facilitate cleaning. Protection Measures The facility has an emergency action plan. Dust collectors are not located inside of buildings. (Some exceptions) Rooms, buildings, or other enclosures (dust collectors) have explosion relief venting distributed over the exterior wall of buildings and enclosures. Explosion venting is directed to a safe location away from employees. The facility has isolation devices to prevent deflagration propagation between pieces of equipment connected by ductwork. The dust collector systems have spark detection and explosion/deflagration suppression systems. Emergency exit routes are maintained properly. Ignition Control Measures Electrically-powered cleaning devices such as vacuum cleaners, and electrical equipment are approved for the hazard classification for Class II locations. The facility has an ignition control program, such as grounding and bonding and other methods, for dissipating any electrostatic charge that could be generated while transporting the dust through the ductwork. The facility has a HotWork permit program. Areas where smoking is prohibited are posted with No Smoking signs. Duct systems, dust collectors, and dust-producing machinery are bonded and grounded to minimize accumulation of static electrical charge. The facility selects and uses industrial trucks that are approved for the combustible dust locations. Prevention Measures The facility has separator devices to remove foreign materials capable of igniting combustible dusts. MSDSs for the chemicals which could become combustible dust under normal operations are available to employees. Employees are trained on the explosion hazards of combustible dusts. Combustible Dust Statement As a manufacturer and supplier of Industrial Filtration Products, Donaldson can assist process owners/operators in the selection of filtration technologies. Donaldson cannot, however, select fire and/or explosion mitigation strategies for process owners. Agricultural Products Egg white Milk, powdered Milk, nonfat, dry Soy flour Starch, corn Starch, rice Starch, wheat Sugar Sugar, milk Sugar, beet Tapioca Whey Wood flour Agricultural Dusts Alfalfa Apple Beet root Carrageen Carrot Cocoa bean dust Cocoa powder Coconut shell dust Coffee dust Corn meal Cornstarch Cotton Cottonseed Garlic powder Gluten Grass dust Green coffee Hops (malted) Lemon peel dust Lemon pulp Linseed Locust bean gum Malt Oat flour Oat grain dust Olive pellets Onion powder Parsley (dehydrated) Peach Peanut meal & skins Peat Potato Potato flour Potato starch Raw yucca seed dust Rice dust Rice flour Rice starch Rye flour Semolina Soybean dust Spice dust Spice powder Sugar (10x) Sunflower Sunflower seed dust Tea Tobacco blend Tomato Walnut dust Wheat flour Wheat grain dust Wheat starch Xanthan gum Carbonaceous Dusts Charcoal, activated Charcoal, wood Coal, bituminous Coke, petroleum Lampblack Lignite Peat, 22% H 2 0 Soot, pine Cellulose Cellulose pulp Cork Corn Chemical Dusts Adipic acid Anthraquinone Ascorbic acid Calcium acetate Calcium stearate Carboxy-methylcellulose Dextrin Lactose Lead stearate Methyl-cellulose Paraformaldehyde Sodium ascorbate Sodium stearate Sulfur Metal Dusts Aluminum Bronze Iron carbonyl Magnesium Zinc Plastic Dusts (poly) Acrylamide (poly) Acrylonitrile (poly) Ethylene (low-pressure process) Epoxy resin Melamine resin Melamine, molded (phenol-cellulose) Melamine, molded (wood flour & mineral filled phenolformaldehyde) (poly) Methyl acrylate (poly) Methyl acrylate, emulsion polymer Phenolic resin (poly) Propylene Terpene-phenol resin Urea-formaldehyde cellulose, molded (poly) Vinyl acetate/ ethylene copolymer (poly) Vinyl alcohol (poly) Vinyl butyral (poly) Vinyl chloride ethylene/vinyl acetylene suspension copolymer (poly) Vinyl chloride/ vinyl acetylene/ emulsion/copolymer Compliance with applicable codes and standards remains the responsibility of the process owner/operator. Among other considerations, the current NFPA standards require owners/operators whose processes involve potentially combustible materials to have a current Hazard Analysis, which can serve as the foundation for the process owner/operators hazard mitigation strategies. Upon request, Donaldson can assist owners/operators to incorporate Donaldson Filtration Product into a comprehensive fire and/or explosion mitigation strategy. To provide this support, Donaldson needs complete and accurate information on all potentially combustible contaminants and the fire and/or explosion mitigation strategies that process owner/operator intends to pursue. * Information on this page from "Combustible Dust Does your company or firm process any of these products or materials in powdered form?" OSHA Poster, (2008). ** The above list from OSHA should not be considered complete, nor should it replace the need to obtain validated test data on your dust. donaldsontorit.com 800-365-1331 6

Industry-Leading Technology Advanced filtration technology for optimal performance Reduced energy consumption and cost of ownership Advanced design and testing capabilities The Most Filters and Parts For every brand and style of collector Wide range of filtration media for any application 90,000 filters and parts in stock and ready to ship Unparalleled Support Live technical specialists Comprehensive pre- and post-sale support 40 manufacturing plants and 14 distribution centers worldwide Significantly improve the performance of your collector with genuine Donaldson Torit replacement filters and parts. Call Donaldson Torit at 800-365-1331. Important Notice Many factors beyond the control of Donaldson can affect the use and performance of Donaldson products in a particular application, including the conditions under which the product is used. Since these factors are uniquely within the user s knowledge and control, it is essential the user evaluate the products to determine whether the product is fit for the particular purpose and suitable for the user s application. All products, product specifications, availability and data are subject to change without notice, and may vary by region or country. Donaldson Company, Inc. Minneapolis, MN donaldsontorit.com shop.donaldson.com North America Email: donaldsontorit@donaldson.com Phone: (USA): 800-365-1331 (MX): 800-343-3639 Australasia Email: marketing.australia@donaldson.com Phone: +61 2 4350 2000 Toll Free: (AU) 1800 345 837 (NZ) 0800 743 387 China IAF Email: info.cn@donaldson.com Phone: (86) 400-820-1038 Donaldson Europe B.V.B.A. Email: IAF-europe@donaldson.com Phone: + 32 (0) 16 38 38 11 India Email: marketing.india@donaldson.com Phone: +91 124 4807400 Toll Free: 18001035018 F118003 ENG (06/18) Dust Collectors and Combustible Dust Strategies 2011-2018 Donaldson Company, Inc. Donaldson, Torit and the color blue are marks of Donaldson Company, Inc. All other marks belong to their respective owners. Latinoamerica Email: IndustrialAir@donaldson.com Phone: +52 449 300 2442 South Africa Email: SAMarketing@donaldson.com Phone: +27 11 997 6000 Southeast Asia IAF Email: IAF.SEA@donaldson.com Phone: (65) 63117373