Model 8356WCSM Pull-Down Shower Eye/Face Wash

Similar documents
Model 8356WCC Pull-Down Shower Eye/Face Wash

Model 7656WCC Eye/face Wash

Model 8330 Stainless Steel Combination Shower Eye/Face Wash

Model /8300CRP-8309CRP Shower & Eye/Face Wash

Model Combination Shower Eye/Face Wash

Model /8320CRP Shower and Eye/Face Wash

Model 8300FP Freeze Resistant Combination Shower Eye/Face Wash

Model 1011/1011HPS Drinking Fountain

Model 9001, Alarm

Model 9001, Alarm

Model TWBS.EW.H Tempered Water Blending System

Model NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

Model TWBS.SHE Tempered Water Blending System

Model 9201EFE Tempered Water Blending System

Model 9201EW Tempered Water Blending System

Model 7501/7501T/7501TH/7501T240/7501T240H Portable Eyewash/Portable Eyewash with Heater

Model 7611 Eye/Face Wash

Model 9001EXP Alarm. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

Model 7500EB Portable Eyewash with Heater

Model H1011.8/H1011.8HPS Water Cooler

Model 1900 Retrofit Bottle Filler

Model 8730 INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS. Outdoor Shower and Eyewash System General Area Classification & Class I Division 2

INSTALLATION & TESTING MANUAL

3121FR Pedestal Mounted Drinking Fountain

Model 7603BL/7603BL240 Heated Blanket for 7603 Portable Eyewash

Model 7603/7603T/7603T240 Portable Eyewash / Portable Eyewash with Heater

Model 8780 INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS. Tempering Skid General Area Classification & Class I Division 2. No.

INSTALLATION & TESTING MANUAL

H Barrier-Free Wall Mounted Electric Drinking Fountain

H1011.8HPS Barrier-Free Wall Mounted Electric Drinking Fountain

H Barrier-Free Wall Mounted Electric Drinking Fountain

Model 1920/1920HPS/1920W Bottle Filler

ADA Compliant Freeze-Resistant Wall-Mount Fountain and Bottle Filler

ADA Compliant Freeze-Resistant Wall-Mount Fountain and Bottle Filler

model1117l with1920 ADA Compliant Dual Wall-Mount Fountain and Bottle Filler FEATURES & BENEFITS MODEL CHOICES OPTIONS SPECIFICATIONS

ADA Compliant Wall-Mount Fountain and Bottle Filler

EMERGENCY DRENCH SHOWER

8317CTFP AXION MSR COMBINATION EYE / FACE WASH & DRENCH SHOWER Freeze Resistant

SEABREEZE. SeaBreeze Rain Shower System Model #1086-CH Owner's Manual

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

SPEAKMAN SPEAKMAN SPECIFICATIONS

ELECTRONIC FAUCETS INSTRUCTION MANUAL. Toll Free: (800) Haul Road Wayne, NJ krowne.

TRU-TEMP VALVE. Tru-Temp Pressure Balance 1/2" Rough-In Valve Owner's Manual 3001-RIV-PB-ORB 3001-RIV-PB-BN 3001-RIV-PB-CH 3003-RIV-PB-ORB

2001 Smith Eastern Corporation

Installation Instructions / Warranty

Heater Installation Kit

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Thermometer. Hot Water Inlet. Cold Water Inlet G3600LF

Flat Line Spray Systems Kits

Installation, Operation and Maintenance Guide AP3900 Series Thermostatic Mixing Valves

55-Gallon Dispenser Package

INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE SERIES LV-981 & LV-982

INSTALLATION ADJUSTMENT SERVICE HIGHLOW THERMOSTATIC WATER MIXING VALVE SERIES XL-32, XL-82

MOJAVE. Mojave ShowerSpa Model #1016 Owner's Manual

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

Installation, Operation and Maintenance Guide G3600 Series Thermostatic Mixing Valves

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

TUB AND SHOWER FAUCET

ENCLOSED UNIT TECHNICAL MANUAL Items # &

Installation S

J120 STEAM BOOSTER INSTALLATION, OPERATION, AND SERVICE MANUAL J120 STEAM BOOSTER. J120 Steam Booster Manual D

55-Gallon Dispenser Package

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Tempered Water Outlet. Hot Water Inlet.

Read and save these instructions! DRANE-KOOLER. Water tempering device Installation, operation and maintenance manual

Installation Instructions / Warranty. PuraVida 15775XX1

Installation Instructions

INSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEM TM-500, TM-550

This Product MasterSpec Section is licensed by AVITRU, LLC to Haws Corporation ("Licensee").

Product Bulletin Recessed Laboratory Units

installation, operation & Maintenance manual Floor-mounted Induction units

SSBF2150 Recessed Safety Station with Drain Pan, Exposed Shower Head

NIAGARA. Niagara ShowerSpa Model #1048B-BN Owner s Manual

SEISCO SUPERCHARGER EXTENDER/BOOSTER INSTALLATION GUIDE & OWNERS MANUAL

installation, operation & Maintenance manual Floor-mounted Induction units acb 30/35

Installation S

Installation S

Instructions. Certifications Brass w/built-in Stop Valve. Pressure Balance Shower Valve. Tools Required. Important Points.

Corrosion Resistant Fluid and Air Handling Systems.

Mini Tank water heater Electric undersink Water heaters GL GL 4 - GL 6+

Oahu Showerspa Model #1035 Owner's Manual

TUB AND SHOWER FAUCET

Installation S19-324D1. Class I, Division 1, Groups C & D Explosion Proof. Emergency Signaling System

Leilani ShowerSpa Model #1022-B Owner's Manual

Installation S

Installation S

RIO. Rio ShowerSpa Model #1049B-BN Owner s Manual

IMPORTANT SAFETY INSTRUCTIONS EC-AG1-25 EC-AG1, EC-AG2 SAVE THESE INSTRUCTIONS.

INSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEM * TM-500A, TM-550A

Installation & Operation Manual

INSTALLATION ADJUSTMENT SERVICE

Installation & Operation Manual

SANTA CRUZ. Santa Cruz ShowerSpa Model #1033 Owner's Manual

Drain Tempering Reservoir READ & SAVE THESE INSTRUCTIONS. Installation, Operation, & Maintenance. TRION

OUTLET HOT INLET COLD INLET INSTALLATION

S19314 Series. Combination Drench Shower and Halo Eyewash or Eye/Face Wash. Recommended Option:

S19314 Series. Combination Drench Shower and Halo Eyewash or Eye/Face Wash. Recommended Option:

BIR Showerhead Installation and User Guide

Transcription:

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS 1455 Kleppe Lane Sparks, NV 8941-6467 (775) 59-4712 Fax (775) 59-7424 E-mail: haws@hawsco.com website: www.hawsco.com Model 856WCSM Pull-Down Shower Eye/Face Wash No. 2080150(8) NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY HAWS warrants that this specific product is guaranteed against defective material or poor workmanship for a period of one year from date of shipment. HAWS liability under this warranty shall be discharged by furnishing without charge F.O.B. HAWS Factory any goods, or part thereof, which shall appear to the Company upon inspection to be of defective material or not of first class workmanship, provided that claim is made in writing to Haws within a reasonable period after receipt of the product. Where claims for defects are made, the defective part or parts shall be delivered to the Company, prepaid, for inspection. HAWS will not be liable for the cost of repairs, alterations or replacements, or for any expense connected therewith made by the owner or his agents, except upon written authority from HAWS, Sparks, Nevada. HAWS will not be liable for any damages caused by defective materials or poor workmanship, except for replacements, as provided above. Buyer agrees that Haws has made no other warranties either expressed or implied in addition to those above stated, except that of title with respect to any of the products or equipment sold hereunder and that HAWS shall not be liable for general, special, or consequential damages claimed to arise under the contract of sale. The emergency equipment manufactured by HAWS is warranted to function if installation and maintenance instructions provided are adhered to. The units also must be used for the purpose for which they were intended. This product is intended to supplement first-aid treatment. Due to widely varying conditions, Haws cannot guarantee that the use of this emergency equipment will prevent serious injury or the aggravation of existing or prior injuries. NO OTHER WARRANTIES EXPRESSED OR IMPLIED ARE AUTHORIZED, PROVIDED OR GIVEN BY HAWS. SHOULD YOU EXPERIENCE DIFFICULTY WITH THE INSTALLATION OF THIS MODEL PLEASE CALL: TECHNICAL SUPPORT: 1-800-766-5612 FOR CUSTOMER SERVICE: 1-888-640-4297 11/17 Model 856WCSM Page 1 of 5

RECOMMENDED TOOLS: Adjustable wrench, pipe wrench, pipe joint sealant, Phillips screw driver, ¼ hex key wrench. LOCATION OF UNIT: The Model 856WCSM eye/face wash should be installed in close proximity to potential accident areas. It should be clearly identified free from obstructions and easy to access. See ANSI Z58.1 guidelines for more information. SUPPLY LINE: The minimum recommended line size is 1" IPS with 0-90 psi (2-6 ATM) flowing pressure at supply inlet. Where sediment or mineral content is a problem, an inlet filter is recommended. PLUMBING CONNECTIONS: Inlet supply is male 1" IPS; waste is 2 IPS. INSTALLATION PROCEDURE Refer to installation drawing for clarification. Check Parts List to ensure all required parts are included. 1. Install all items at dimensions shown in installation drawing. 2. Once valve assembly is installed, install mounting frame(s) over valve assembly.. IMPORTANT: Showerhead must be positioned in-line with eye/face wash to allow for simultaneous use by the same user per ANSI Z58.1. 4. Install remaining items to dimensions shown. 5. Each unit is factory preset to meet the 5 pound (22.2 N) maximum activation force requirement for disabled persons. If adjustment is required after installation, follow the adjustment directions below. a) Locate the two ball detents, one on each side of the eyewash tray. See installation drawing. b) Using a flat screwdriver, adjust each ball detent to make slight contact with the eyewash housing just before the ball detent snaps into its locating position on the housing. c) Once both ball detents are adjusted as above, tighten each ball detent ¼ turn. d) Using a force gauge, ensure the force required to open the eyewash unit does not exceed 5 pounds (22.2 N). CLEANING INSTRUCTIONS FOR STAINLESS BEAD-BLASTED PRODUCTS Haws recommended cleaning procedure for stainless bead blasted products is as follows: 1. Use a stainless steel polish and cleaner for removing stains and finger prints. 2. Spray cleaner onto stainless surfaces and wipe dry with clean cloth. Cleaned surface will resist new stains and fingerprints. 11/17 Model 856WCSM Page 2 of 5

INCLUDED PARTS MODEL PACKAGE QUANTITY ITEMS INCLUDED 856WCSM 1 Mounting Frame/Eyewash assembly 1 Surface Mount Frame 1 Valve assembly 1 Handle/screw assembly 1 Showerhead 1 1 x 2-1/2 Nipple 1 1 elbow 1 1 Street elbow 1 Emergency Eyewash/shower sign 1 Test Tag 1 1 X 46 Nipple 1 1 X 9-1/2 Nipple TROUBLESHOOTING PROBLEM REPAIR CHECKLIST 1. No flow. 1. Check the main shut-off valve. 2. Insufficient water flow at eye/face wash.. Eye/face wash streams do not meet desired eye level. 2a. Verify minimum 0 psi (2 ATM) flowing supply line pressure. b. Probable clogging of flow control due to inadequate line flushing. Unscrew eye/face wash head and remove the four screws to disassemble the head. Clean the flow control and reassemble head. c. Remove cap located on in-line strainer housing using a ¼ Allen wrench to access and clean filter screen. See installation drawing for location. a. Possible blocked flow control, see above solution. b. Possible non-leveled eye/face wash assembly. c. Possible low supply pressure. 4. Insufficient water flow at the showerhead, however, eye/face wash is sufficient. 5. Tray too hard to open or does not stay closed. 4. Probable clogging of flow control inside showerhead. Remove showerhead by unscrewing it and clean rubber flow control. 5. See Installation Procedure Step 5. For more information about Haws products, see our website: www.hawsco.com. 2017 Haws Corporation All Rights Reserved HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation. 11/17 Model 856WCSM Page of 5

THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEMENTS MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE. 5 ITEM 1 2 4 5 6 7 DESCRIPTION TEST TAG SHOWER/EYEWASH SIGN SHOWER HEAD SHOWER BALL VALVE FLOW CONTROL VALVE REPAIR KIT PART NO. SP170 SP178 SP829SS 0006575900 0001892 SP65PD VRK7650 7 6 4 2 1 PARTS BREAKDOWN 1455 KLEPPE LANE SPARKS, NEVADA 8941 (775) 59-4712 FAX (775) 59-7424 E-MAIL: HAWS@HAWSCO.COM WEBSITE: WWW.HAWSCO.COM ECN NO. REVISED PER BY MODEL(S) PART NUMBER 4290 ECN: 5242 VWC DRAWN DATE CHKD 856WCSM REVISION I. ROBERTS 07/21/10 VWC APPROVED DATE 8 FV 11/2/17 SCALE: 1/8 DRAWING TYPE: PARTS BREAKDOWN SIZE: A SHEET 1 OF 1 WHEN ORDERING PARTS PLEASE SPECIFY MODEL NUMBER. C 2017 Haws Corporation - All Rights Reserved R HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation. 0002080150 PAGE 4 of 5

THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEMENTS MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE. HANGER BRACKET (NOT SUPPLIED) 5 OF 5 STAINLESS STEEL SHOWER HEAD WITH 20 GPM FLOW CONTROL 1 X 9 1/2" SST NIPPLE 1 X 46" S.S. NIPPLE 1 X 2-1/2" S.S. NIPPLE Ø 10-1/2" 267mm (5-7/8") (911mm) PAGE "PANIC BAR" (SHOWN IN OFF POSITION- PULL DOWN TO ACTIVATE) 2-1/2" 826mm 11 1/4" 292mm 22 1/2" 572mm 2-9/16" 598mm 1" IPS BRASS STAY OPEN BALL VALVE WITH INLET AND OUTLET UNION 19-1/4" 489mm 6X Ø/16" 4 4.8mm MOUNTING HOLE 2X 11-1/2" 292mm (84-1/2") (2148mm) (SHOWN IN ON POSITION) SHOWER "PANIC BAR" (SHOWN IN OFF POSITION PULL DOWN TO OPEN -/4" 95mm 6-9/16" 167mm 2" NPT FEMALE OUTLET REMOVABLE ACCESS PANELS (NOT SHOWN) 1" IPS FEMALE SUPPLY INLET IN-LINE STRAINER HOUSING (47-1/2") (1206mm) "-5" 88mm-146mm FLOW PATTERN (4-5/8") (879mm) 2X BALL DETENT (29-5/8") (752mm) 18-1/2" 470mm 20-5/8" 524mm FLOOR LINE 1-11/16" 4mm 1-11/16" 4mm 4-1/4" 108mm -1/16" 97mm NOTES: 1. WHEN INSTALLING THIS UNIT, LOCAL, STATE, OR FEDERAL CODES SHOULD BE ADHERED TO FOR INSTALLATION DIMENSIONS (LOCATIONS), WASTE AND SUPPLY REQUIREMENTS OTHER THAN SHOWN. 2. TO COMPLY WITH ANSI Z58.1-2014 FOR EMERGENCY EYEWASH OR : EYEWASH OR SHALL BE POSITIONED SUCH THAT FLUSHING FLUID PATTERN IS NOT LESS THAN " (88mm), NO GREATER THAN 5" (146mm) FROM SURFACE ON WHICH USER STANDS, AND 6.0" (15mm) MINIMUM FROM WALL OR NEAREST OBSTRUCTION. SHOWER MUST BE POSITIONED IN-LINE WITH EYE/FACEWASH HEAD TO ALLOW FOR SIMULTANEOUS USE BY THE SAME USER PER ANSI Z58.1. 4 MOUNTING HARDWARE NOT SUPPLIED. 5. DIMENSIONS MAY VARY BY ±1/2" (1 mm). C 1455 KLEPPE LANE SPARKS, NEVADA 8941 (775) 59-4712 FAX (775) 59-7424 E-MAIL: HAWS@HAWSCO.COM WEBSITE: WWW.HAWSCO.COM ECN NO. REVISED PER BY: MODEL(S) PART NUMBER 4290 ECN: 5242 VWC DRAWN: DATE: CHK'D.: 856WCSM REVISION I. ROBERTS 7/1/10 VWC APPROVED: DATE: 8 FV 11/2/17 SCALE: 1/19 DRAWING TYPE: INSTALLATION SIZE: A SHEET 1 OF 1 R 2017 Haws Corporation - All Rights Reserved. HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation. 0002080150.D