Technical Bulletin. Concealed extended flues

Similar documents
Appliance Make / Model Location Repaired I.S. 813* Annex C * Annex E * Type Installed Serviced Safety Check

Appliance Make / Model Location Repaired I.S. 813/I.S. EN 1949* Annex C * Annex E * Type Installed Serviced Safety Check

Technical Bulletin. Gazco Riva2 800 & 1050 Gas Fires- Installation and servicing issues resulting in Glass Panel Failure.

The Register of Gas Installers of Ireland (RGII)

DOMESTIC PREMISES GAS INSTALLATION

putting safety first natural gas

Technical Bulletin 008 (Edition 2) CIP-RACL Developed by Industry

Title: Room-sealed fanned draught flue systems concealed within voids

Domestic Gas Safety Assessments (DGA) Competency Assessment Certification Scheme for Registered Gas Installers

Safety Alert New Gas Regulation 2013

QUALIFICATIONS AND CREDIT FRAMEWORK (QCF) LOGIC CERTIFICATION LIMITED (LCL) QUALIFICATION SPECIFICATION

Standards of Training in Safe Gas Work Domestic Natural Gas Training Specification

Domestic Gas Safety Assessments (DGA) Competency Assessment Certification Scheme for Registered Gas Installers

REGULATED QUALIFICATIONS FRAMEWORK (RQF) LOGIC CERTIFICATION LIMITED (LCL) QUALIFICATION SPECIFICATION

Annex 5a Solid fuel (Domestic) Annex 5a Common Minimum Technical Competency Requirements for Solid fuel burning appliance installation (domestic)

2.0 VISIT TO SITE. It was immediately evident entering the boiler house that there are several issues with the existing installation.

VENTING CLEARANCES. BBT NORTH AMERICA Bosch Group. Bosch Water Heating 340 Mad River Park, Waitsfield, VT TWH-V-26 page 1 of 6 rev 01/06

F I R E S A F E T Y R E G I S T E R

Welcome to RGII NEWSLETTER FOR REGISTERED GAS INSTALLERS RGII ISSUE 2 MARCH 2012

Protect Safety Alarms

Part J of the Building Regulations: Changes for 2010 Tuesday 28 th September 2010 Presenter: David Bleicher

Home CALOR. At with INTRODUCING OUR NEW TUMBLE DRYER SAFETY AT HOME

The new Gas Appliances Regulation (EU) 2016/426

The Gas Safety (Installations and Use) Regulations 1998.

Non-domestic gas installations (Edition 2)

Annex 4a Common Minimum Technical Competency Requirements for Oil Appliance Installation Work (Domestic)

Side by side. Cascade Venting System for RTG 199HE. Extension Set for units 3 or Installation instructions

Installation Instructions

Extension of Registered Gas Installer Scheme to include Non-Domestic Gas Works

HHIC consumer guide to gas boiler servicing

Back to back. Cascade Venting System for RTG 199HE. Basic Set for units 1 and Installation instructions

GB162 Concentric Horizontal Vent Kit

Walkthrough Inspection Checklist

CHC's One Big Housing Conference Health and Safety Update: Gas Safety

Carbon Monoxide Safety Information

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE

Carbon Monoxide Safety

I n s t r u c t i o n m a n u a l f o r b u i l t - i n h o o d. Model code: BORA600

ADVICE NOTE GAS SAFETY. How you can stay gas safe in your flat

USER GUIDE VOGUE MAX SYSTEM

Sargasso Range. Installation manual. Sargasso A. Issue 001 January 2018 ENGLISH UK IRL SmithsEP.co.uk

WARMCAIR. Condensing Air & Water Heater. High Efficiency Downflow Condensing Air & Water Heater USERS INSTRUCTIONS

Exhaust Duct Design Page 1 of (C)

COMBUSTION APPLIANCE SAFETY INSPECTION FOR VENTED APPLIANCES*

CHAPTER 5 - STRUCTURAL FIRE PRECAUTIONS

AUTOMATIC MAKE-UP AIR DAMPER WITH TRANSFORMER READ AND SAVE THESE INSTRUCTIONS

Regulation of Gas Installers with respect to Safety Definition for the Scope of Gas Works With regard to Liquefied Petroleum Gas (LPG)

WIRELESS GAS DETECTION & SHUT OFF SYSTEM INSTRUCTION MANUAL. Wireless Gas Detection & Shut Off System - User Manual & Instructions

Fuel Oil Heating Installation Inspection Report #1 2008

Wausau Fire Department Inspection Violation Code Listing (Modified) All Applicable Records

,4X IMPORTANT SAFETY INSTRUCTIONS

Building Regulations Update. by Eamonn Smyth

EXTRACTOR HOOD. Please read all the instructions carefully before starting the installation. 230 / 240V 50Hz

MRXBOX95B-LOFT. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Loft Mounting. Installation and Maintenance

The Heating System and Ventilation and Combustion Air

Technical Bulletin Developed with Glow-worm

Building Standards Division. Whisky Maturation Warehouses Storage Buildings (Class 1) Automatic Fire Suppression Systems

Installation and Servicing Instructions. Alpha GasSaver GS-2

Carbon Monoxide Alarms for Boats

5.5.1 General CD/30 (Oil Condensing Boiler Installation Assessment Form) General Technician Stationary...

USER GUIDE VOGUE COMBI GEN2 C26 C32 C40

FIRE SAFETY MANAGEMENT PROTOCOL FIRE DOORS & FIRE DOOR ASSEMBLIES

Introduction. Products conforming with a European Council Directive. CE marked construction products. Other regulations

AMENDMENTS TO THE BUILDING AND FIRE CODE FOR THE CITY AND COUNTY OF DENVER

Installation and Servicing Instructions. Alpha GasSaver GS-1

e. Potential sources of air contaminants do not exist near the building. (e.g. chimneys, stacks, industrial plants, exhaust from nearby buildings)

Section C-2 of the Gas Regulations

PLAN THE INSTALLATION Planning the installation first requires selecting the most appropriate installation approach. The chart below offers suggestion

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Bracket

e. Potential sources of air contaminants do not exist near the building. (e.g. chimneys, stacks, industrial plants, exhaust from nearby buildings)

Esse B MODEL Roomheater with boiler WOOD BURNING ONLY MODEL

Comhshaol, Pobal agus Rialtas Áitiúil Environment, Community and Local Government. Fire safety at home

COMBINATION SOLUTION FOR COLLECTIVE FLUE, AIR VENTILATION AND EXHAUST

Code of Practice - Ventilation- Mechanical Extract Ventilation (MEV) + Mechanical Ventilation with Heat Recovery (MHVR)

Sandwell Valley School and Sandwell Community Care Trust Training. 150 Birmingham Road, West Bromwich, B70 6QT

Twin Wall Installation Instructions And Maintenance Guide

Permanent Ventilators (for the Supply of Combustion Air)

USER GUIDE LOGIC HEAT H

User s Information Manual

INSTALLATION AND OPERATING INSTRUCTIONS TABLE OF CONTENTS IMPORTANT

FIRE SAFETY POLICY June 2014

7.4 CD/12 (Landlord Oil Installation Safety Check)

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

DOMESTIC SMOKE. working for a cleaner, quieter, healthier world

Gas Fired Humidifier. SKG Series Combustion Field Adjustment Instructions. SKG Combustion Field Adjustment Instructions

carbon monoxide alarms

Gas Technical Standards Committee

IMPORTANT It is vital that the information in this leaflet, the user instructions and the appliance labels are carefully read and adhered to.

Implementation Guidance for ISO 9001:2008

MRXBOX95-WALL. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Extract air.

Introduction ... The HETAS Guide. to Approved Solid Fuel, Wood and Biomass Products and Services. List no. 24 HETAS 2018

To: All SAAS Accredited Certification Bodies Subject: Clarification to Emergency and Health & Safety Requirements in the SA8000 Standard

Do not use this vent pipe or fittings for venting incinerators of any kind.

New Approaches to Design for Fire Safety

Guidance Note. Guidance Document on Best Practice for Fire Detector Testing/Test Equipment

User Guide. Promax SL Condensing Central Heating Boiler

Top of the World Tower

about your house Assessing the Comfort and Safety of Your Home s Mechanical Systems

Section 42. Lead Paint Risk Factor NONE WATER HEATER STORAGE GAS

SUP 14: Floor laying. Unified procedures for use within NHS Scotland

Transcription:

Register of Gas Installers of Ireland Unit 9, KCR Industrial Estate, Ravensdale Park, Kimmage, Dublin 12 Tel: 01-4997998 Fax: 01-4929983 Email: installationstandards@rgii.ie Technical Bulletin Concealed extended flues January 2012

BACKGROUND: Introduction Incidents have occurred in Ireland and in the UK where joints between flue sections have become disconnected either through not being installed correctly or through interference. A disconnected flue will permit products of combustion to terminate within the property with a risk of carbon monoxide poisoning to those occupants within the property and in neighbouring properties. In accordance with the relevant manufacturers instructions, I.S. 813 and Building Regulations Part J 1997, all products of combustion must terminate outside of building. Before commencing the service and inspection of a gas appliance, it is therefore critical that the RGI is equipped with the appliance manufacturers instructions and correct tools including, where appropriate a calibrated flue gas analyser (specification EN 50379). As a Registered Gas Installer (RGI) you are responsible for ensuring you carry out gas works safely and in line with the relevant technical standards. The Irish Standard for Domestic Gas Installations (I.S. 813) and the relevant manufacturers instructions must be adhered to when installing and servicing gas appliances. All requirements including those relating to Flueing, Ventilation and Permitted Location must be adhered to. While servicing appliances and/ or carrying out gas safety inspections it is imperative that all RGIs are aware of the specific requirements of I.S. 813 and the manufacturers instructions that relate to the flueing of the appliance. It is essential that The effectiveness of any flue or chimney be checked. Scope This technical bulletin provides guidance and clarity to RGI s on the additional steps to take at gas installations where the flue is concealed and extended within a duct or a void (i.e. roof spaces, studs, walls, ceilings etc.) It is stressed that equal care must be taken when inspecting and testing standard flues, non-concealed flues or chimneys however this bulletin deals specifically with concealed extended flues. An extended flue is any flue with more than two joints, those being the joint at the boiler flue inlet/outlet and the joint at the terminal. 2

SAFETY ACTIONS: When requested by a customer to carry out a service/repair or safety inspection on a gas installation which includes a concealed extended flue the following additional steps must be carried out, as well as those required by Annex C of I.S. 813. Servicing a domestic gas appliance Appliances shall be serviced according to I.S. 813 and manufacturers instructions. In servicing the appliance(s), the Registered Gas Installer shall address the following safety indicators: Visually inspect the exposed flue where possible. Ensure the flue is installed as per manufacturers instructions. Where access to flue is not available Visually inspect the pathway of the concealed extended flue for evidence of staining. If access to the void is available carry out a CO test in the void. Ask customer if there has been any ongoing problems/issues with boiler performance. When these steps have been achieved, continue with the following: Perform combustion flue gas analysis and air intake contamination analysis at the flue sample points (where fitted) at the boiler. If no sample points are fitted at the boiler then the flue gas sample should be taken at the flue terminal where reasonably possible. Gas rating and burner pressure Rate the gas appliance at the gas meter. It must fall within the range specified on the data badge on the appliance and/or in the manufacturers instructions. If this is not possible then the appliance working pressure (all appliances) and burner pressure (where applicable) shall be checked and must be within the range as displayed on the data badge on the appliance and/or in the manufacturers instructions. Customer Awareness/ Notification Wherever there is a concealed flue which cannot be inspected and on completion of the above steps: 3

Issue the owner/occupier responsible for the premises in which concealed extended flues are fitted with the Concealed Flue Advisory Note from RGII. The issuing of the Concealed Flue Advisory Note must be recorded in the comments section of the Certificate of Conformance (Certificate 3) and witnessed by way of the owner/occupier signature. The Concealed Flue Advisory Note does not replace a Notice of Hazard. NOTE When the steps in this Technical Bulletin have been carried out in addition to those in Annex C of I.S. 813 and it is considered that there may be a safety risk a Notification of Hazard must be issued. 4

Appendix A- Concealed Flue Advisory Note Concealed Flue Advisory Note Dear Owner/Occupier, Your Registered Gas Installer (RGI) has identified that your gas installation includes a concealed (hidden) extended flue from your boiler to the flue terminal outside. This flue is designed to safely remove flue gases produced by your boiler to outside of your building. If it is not installed correctly Carbon Monoxide may be produced and could be a risk to your health. Your RGI has attempted to inspect the flue. However because it is hidden it has not been possible to carry out a full inspection. Without access to the flue your RGI cannot fully confirm the safety of its installation. It is strongly recommended that you take further steps to ensure your own safety, that of other people in the property and your neighbours by making the hidden sections of the flue accessible for inspection by a RGI. Your RGI will be able to advise you on the options available to you. Additional safety measures In addition to making the hidden sections of the flue accessible for inspection it is also strongly recommended that you have a Carbon Monoxide alarm(s) installed by a competent person, such as a RGI. When installing a Carbon Monoxide alarm: Make sure it meets the standard EN 50291 (this will be marked on the packaging); Make sure it has an end-of-life indicator and carries a third party certification mark, for example the BSI Kitemark; Make sure that the installation instructions are followed to ensure that your Carbon Monoxide alarm is installed in the correct location and operates effectively. You should also regularly check the path of your flue for staining or discolouration and have your boiler serviced annually by a RGI. If you see any evidence of staining or discolouration along the path of, or near the flue, switch off your gas appliance and contact your RGI immediately to inspect the entire length of the flue. Staining may be a sign that your flue has corroded and may require immediate replacement. Visit www.carbonmonoxide.ie or phone 1850 797979 to learn more about the signs and dangers of Carbon Monoxide. 5

For further information on getting your flue inspected or to find a RGI, please contact the Register of Gas Installers of Ireland on 1850 454 454 or 01 4997998. You can also visit our website www.rgii.ie Yours sincerely, The Register of Gas Installers of Ireland 6