IECC. nlight Applications Guide.

Similar documents
Mini Product Guide.

CA TITLE 24 QUICK SOLUTIONS GUIDE FOR

Catalog Number. Notes

Catalog Number. Notes. Type ADP. Series Air function Lumens Diffuser Voltage Driver Color temperature. Acrylic linear prismatic

Catalog Number. Notes

Lighting Control Strategies. to meet code requirements save energy and improve building performance

North Hanover Township School District North Hanover Township, New Jersey

visual environment technologies etcconnect.com

Vive Solutions. Commercial Application Guide Code Compliance Lighting Controls IECC 2015

800 TO 9000 LUMEN 10 LED RETRO-FIT HYPERBOLIC / PARABOLIC LRT10 SERIES

Catalog Number. Notes

Vive Solutions. Commercial Application Guide Code Compliance Lighting Controls IECC 2012

Energy Codes. Connected Lighting simplified by Eaton. design and application guide

DEMOLITION GENERAL NOTES As-built conditions have been determined from Record Drawings (if they exist), field investigations (accessible areas and

Vive Solutions. Commercial Application Guide Code Compliance Lighting Controls IECC 2015

visual environment technologies etcconnect.com

800 TO 9000 LUMEN 8 LED RETRO-FIT HYPERBOLIC / PARABOLIC / WALLWASH LRT8 SERIES

ANSI/ASHRAE/IES

ANSI/ASHRAE/IES

LightSweep. Lighting Control System

LOW PROFILE 4 APERTURE UP TO 4800 LUMENS DELIVERED LLP4/LLPRM4 SERIES

LIGHTING CONTROLS

800 TO 9000 LUMEN 6 LED RETRO-FIT HYPERBOLIC / PARABOLIC / WALLWASH LRT6 SERIES

Code Compliance. Lightcloud. Guides for California Title 24 & ASHRAE

3 2 1 A B D F

Empowering Your Vision

Code Compliance Commercial Application Guide

East Central College

Advances in Non-Residential Lighting Technologies

CERRA 10 LED Design2Ship

MANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130.1)

800 TO 9000 LUMEN 8 LED RETRO-FIT HYPERBOLIC / PARABOLIC / WALLWASH LRT8 SERIES

800 TO 9000 LUMEN 6 LED RETRO-FIT HYPERBOLIC / PARABOLIC / WALLWASH LRT6 SERIES

Lighting Application Guide for K-12 Classrooms

Reduce lighting energy costs with controls

Restaurants IECC 2015 Solutions

Hawthorn Building. Penn State Altoona Campus Altoona, PA. Walter Nichols. Lighting/Electrical Option Faculty Advisor: Dr.

A Guide for Applicants and Lighting Designers

SECTION NETWORK LIGHTING CONTROLS

LIGHTING CONTROLS. Smart Enough to Work Right Out of the Box

Wireless Indoor Lighting Control System

Balance LC. classroom light control fixture solution. simple to order simple to install simple to use

800 TO 9000 LUMEN 6 LED NEW CONSTRUCTION/REMODEL/FLANGELESS HYPERBOLIC / PARABOLIC / WALLWASH L6 / LRM6 SERIES

Hubbell Controls Application Guide to ASHRAE 90.1 A SUPPLEMENTAL GUIDE TO CODE REVISIONS IMPACTING LIGHTING CONTROL

800 TO 5500 LUMEN 6 LED CYLINDER HYPERBOLIC / PARABOLIC / WALLWASH / OPEN APERTURE LC6 SERIES

800 TO 2800 LUMEN 4 LED CYLINDER HYPERBOLIC / PARABOLIC / WALLWASH / OPEN APERTURE LC4 SERIES

DIVISION 26 ELECTRICAL SECTION LIGHTING CONTROL SYSTEM

Product Specifications Dialog Room Controller* (*patent pending)

Advanced Lighting For Office

800 TO 5500 LUMEN 8 LED CYLINDER HYPERBOLIC / PARABOLIC / WALLWASH / OPEN APERTURE LC8 SERIES

CONTROLS SOLUTIONS GUIDE

Dissecting Lighting Control Requirements ANSI/ASHRAE/IES Standard & 2013

SECTION LIGHTING CONTROLS

800 TO 8000 LUMEN 4 LED NEW CONSTRUCTION/REMODEL/FLANGELESS HYPERBOLIC / PARABOLIC / WALLWASH L4 / LRM4 SERIES

WVU DESIGN GUIDELINES & CONSTRUCTION STANDARDS DIVISION 26 ELECTRICAL

A Simpler and Smarter Wireless Lighting Control Solution. Design & Application Guide

800 TO 9000 LUMEN 6 LED NEW CONSTRUCTION/REMODEL/FLANGELESS HYPERBOLIC / PARABOLIC / WALLWASH L6 / LRM6 SERIES

800 TO 9000 LUMEN 8 LED NEW CONSTRUCTION/REMODEL/FLANGELESS HYPERBOLIC / PARABOLIC / WALLWASH L8 / LRM8 SERIES

Application Guide to CA Title 24

800 TO 9000 LUMEN 6 LED NEW CONSTRUCTION/REMODEL/FLANGELESS HYPERBOLIC / PARABOLIC / WALLWASH L6 / LRM6 SERIES

Distributed Low-Voltage Power System. design and application guide

Education Title Solutions

VESICA LINEAR SUSPENDED VES L

SECTION 26 NX DISTRIBUTED INTELLIGENCE LIGHTING CONTROL SYSTEM HUBBELL CONTROL SOLUTIONS

Lighting Controls. Energy-Saving Solutions For Efficient Buildings

High Performance Lighting. Terry Egnor Senior Consultant NBI

Connectivity Control Confidence

UBC Technical Guidelines Section Edition Interior Building Lighting Page 1 of 5

California s 2008 Building Energy Efficiency Standards for Residential and Nonresidential Buildings

CONTENTS SENSOR SWITCH

PRESCRIPTIVE APPROACH

Lithonia Lighting LED Downlighting. A Solutions Guide For Every Need, Every Application, Every Budget

Indoor Controls. SpaceWise SWZG2. Wireless technology

ADDENDUM NO. 2 COOK LIBRARY BATHROOM RENOVATIONS PROJECT NUMBER TU-1874-SBR

Connecting Lighting & Controls

ASHRAE October 18, 2013

Sensors and Detectors

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

SECTION DIGITAL-NETWORKING LIGHTING CONTROLS ENLIGHTED LIGHT MANAGEMENT SYSTEM

DUFFERIN-PEEL CATHOLIC DISTRICT SCHOOL BOARD

Shannon J Markey LC, LEED AP Legrand BCS / Wattstopper Western Regional Manager. Yesterday, Today & Tomorrow

Restaurants ASHRAE Solutions

Ceiling Mount Sensors B4-B9. Occupancy and Vacancy Sensors B10-B15 B16-B17. Wall Mount Occupancy Sensors B-1

CRESTRON: GREEN LIGHT NETWORK LIGHTING CONTROLS 1

Lighting Controls An Introduction and Review

Connected Buildings Sales positioning guide

Applied Lighting Controls

Metalux SWLED LED. Type. Catalog # Project. Date. Comments. Prepared by

TITLE 24 ICONOGRAPHY. Iconography System

Intentional Uplighting for Unprecedented Uniformity. Phuzion PHS LED High Bay 1

WSA120: New Energy Codes and Lighting Controls

Commercial & Industrial Lighting LED Retrofits for Troffers

Connected Buildings Sales positioning guide

Connected lighting components. Xitanium SR drivers EasyAir office sensors. Connected lighting components

Lobby Lighting Design

Technology. Occupancy & Vacancy Sensors & Timers. Technology. Occupancy & Vacancy Sensors & Timers L-2

Project Name. Date. Cat. Number. Type

Office Title Solutions

Are LED s ready for Prime Time?

Overview. The Reading Room

Transcription:

IECC nlight Applications Guide www.acuitycontrols.com

2 Intro ACUITY CONTROLS It s not just smarter. It s easier. Acuity Controls is advanced lighting controls technology, service and support from a single expert source. We offer one of the industry s most extensive product portfolios for indoor and outdoor applications; single rooms to campuses to municipalities. Our product solutions include occupancy and photosensors, centralized and distributed systems, panels, fixture-integrated, wired and wireless controls that simply work. www.acuitycontrols.com 800-535-2465

Table of Contents 1 TABLE OF CONTENTS 04 05 06 10 12 14 17 18 20 24 26 27 28 Code Requirements for Common Building Spaces How to Use This Guide Private Office Solutions Open Office Solutions Conference Room Solutions Classroom Solutions Stairwell Solutions Lobby Solutions Restroom Solutions Corridor Solutions Network Control Appendix A nlight Enabled Fixtures Appendix B Requirements Overview IECC: nlight Applications Guide

2 Title 24 Lighting Control www.acuitycontrols.com 800-535-2465

About 3 ABOUT About IECC The International Energy Conservation Code (IECC) 2015 is a residential and commercial building energy code. The IECC has been adopted by many states and municipalities. The intention of the code is to reduce energy consumption by outlining design and construction requirements which include specific constraints for lighting controls. The use of lighting controls to synchronize light levels with daylight, occupancy, and multi-level control demand response capability are required in order to be compliant. About this Guide Acuity Controls offers the nlight IECC Application Guide to facilitate quicker and easier code compliant lighting control solutions to aid in complying with the requirements of IECC. Use this guide as a quick reference of typical nlight layouts that can help get your project on the path towards compliance. The Acuity Controls Design Services Team is also available to support engineers and contractors with detailed design, submittal, and installation. For additional information, please contact your Acuity Brands Sales Representative. About nlight The nlight networked digital lighting control system is easy-to-use, easy-to-install and saves energy. Using only standard CAT-5e cable, nlight networks together occupancy sensors, wall stations, and digital LED luminaires to create a digital lighting system with unmatched flexibility! nlight easily scales from one room to an entire campus. Create a lighting control solution that s perfect for your space and need. IECC: nlight Applications Guide

4 Code Requirements for Common Building Spaces The chart below is an overview of the Code Requirements for Common Building Spaces. Please use this information as a guide. For specific code requirements please refer to the IECC code. Space Type Control Requirement* Code Provision Code Summary* Private Office Open Office Conference, Classroom, Meeting, Lecture Hall, Multipurpose Training Room Room Lobby Corridor Restroom Stairwell Manual-On or Partial-On C405.2.1.1.2 Automatically controlled spaces must be controlled to automatically turn the lighting on to not more than 50% power. Full Automatic-On C405.2.1.1.2 Automatically controlled spaces are allowed to turn on to full. Full Auto-Off via Occupancy Sensor C405.2.1.1.1 Fixtures must automatically turn off within 30 minutes of all occupants leaving the space. On-O f Control Programmable Timeclock C405.2.2.1 Each area of the building not provided with occupant sensor controls shall be provided with time switch controls. These areas must also be provided with a manual override switch. (or) (or) (or) (or) Manual Lighting Reduction C405.2.2.2 Spaces shall have a manual control that allows the occupant to reduce the connected lighting load uniformly by at least 50%. (or) (or) Local Switch C405.2.1.3 Areas shall incorporate a manual control to allow occupants to turn fixtures off. Daylight Control Daylight- Responsive Controls C405.2.3.1/2 Daylight-responsive controls shall be provided within each space with sidelight and toplight daylight zones. * Note: This summary is for general information purposes only and is provided without any warranty as to accuracy, completeness, or otherwise. The user should read the applicable code sections for more complete and detailed descriptions of code requirements and exceptions and should consult with a professional engineering or other competent advisor before making any decision or taking any action based on this summary. www.acuitycontrols.com 800-535-2465

How to Use This Guide 5 Quick summary of applicable code sections Room description Room layout with devices & locations 6 PRIVATE OFFICE: No Windows, nlight Enabled Fixtures Room layout diagram with control, fixture, and wiring type detail Local Switch (C405.2.2.3) Lighting Reduction (C405.2.2.2) Enhanced Digital Lighting Controls (C406.4) CAT-5e Cable Line Voltage Wires Line Power Feed 4 Various; see Appendix A nlight Enabled Fixture 1 On/Off & Raise/Lower WallPod 1 Dual Technology Occupancy Sensor Required list of devices in order to implement room layout design above OPERATION DETAILS: ADDITIONAL OPTIONS: All fixtures are controlled together or independently Maximum level can be limited to 80% Optional automatic lumen compensation Daylight Control: Fixtures must be turned Not required for offices on manually (or optionally without windows or that can be configured to have loads <150W in come on automatically sidelight zones to 50%) Fixtures automatically turn off when room becomes vacant Manual Control: On/off & raise/lower control of fixtures Surface or recessed mount sensors also available Room can be connected to nlight backbone For emergency lighting control order fixtures with -n80emg or -n100emg option www.acuitycontrols.com 800-535-2465 Operational details describe the functionality provided by the equipment specified in the solution Additional options that add control capacity beyond code requirements IECC: nlight Applications Guide

6 PRIVATE OFFICE: No Windows, nlight Enabled Fixtures Local Switch (C405.2.2.3) Lighting Reduction (C405.2.2.2) Enhanced Digital Lighting Controls (C406.4) CAT-5e Cable Line Voltage Wires Line Power Feed 4 Various; see Appendix A nlight Enabled Fixture 1 On/Off & Raise/Lower WallPod 1 Dual Technology Occupancy Sensor OPERATION DETAILS: ADDITIONAL OPTIONS: All fixtures are controlled together or independently Maximum level can be limited to 80% Optional automatic lumen compensation Fixtures must be turned on manually (or optionally can be configured to come on automatically to 50%) Fixtures automatically turn off when room becomes vacant Daylight Control: Not required for offices without windows or that have loads <150W in sidelight zones Manual Control: On/off & raise/lower control of fixtures Surface or recessed mount sensors also available Room can be connected to nlight backbone For emergency lighting control order fixtures with -n80emg or -n100emg option www.acuitycontrols.com 800-535-2465

PRIVATE OFFICE: No Windows, 0-10V Dimming Fixtures 7 npp16 D Local Switch (C405.2.2.3) Lighting Reduction (C405.2.2.2) CAT-5e Cable Line Voltage Wires Line Power Feed 0-10V Wires 1 npp16 D Relay Module with 0-10V Dimming Output 1 On/Off & Raise/Lower WallPod 1 Dual Technology Occupancy Sensor OPERATION DETAILS: ADDITIONAL OPTIONS: All fixtures are controlled together Maximum level can be limited to 80% Fixtures must be turned on manually (or optionally can be configured to come on automatically to 50%) Fixtures automatically turn off when room becomes vacant Daylight Control: Not required for offices without windows or that have loads <150W in sidelight zone Manual Control: On/off & raise/lower control of fixtures Surface or recessed mount sensors also available Room can be connected to nlight backbone For emergency lighting control add a npp16 D ER pack. IECC: nlight Applications Guide

8 PRIVATE OFFICE: Windows, nlight Enabled Fixtures Local Switch (C405.2.2.3) Lighting Reduction (C405.2.2.2) Sidelight Daylight Zone (C405.2.3.2) Enhanced Digital Lighting Controls (C406.4) ncm PDT 9 ADCX (RJB) CAT-5e Cable Line Voltage Wires Line Power Feed 4 Various; see Appendix A nlight Enabled Fixture 1 On/Off & Raise/Lower WallPod 1 ncm PDT 9 ADCX (RJB) Dual Technology Occupancy Sensor with Automatic Dimming Photocell OPERATION DETAILS: ADDITIONAL OPTIONS: All fixtures are controlled together or independently Maximum level can be limited to 80% Optional automatic lumen compensation Fixtures must be turned on manually (or optionally can be configured to come on automatically to 50%) Fixtures automatically turn off when room becomes vacant Daylight Control: Smooth continuous dimming Custom grouping of fixtures into separate daylight zones (max. number zones = number of fixtures) Not required for offices without windows or that have loads <150W in sidelight zones Manual Control: On/off & raise/lower control of fixtures Surface or recessed mount sensors also available Room can be connected to nlight backbone For emergency lighting control order fixtures with -n80emg or -n100emg option www.acuitycontrols.com 800-535-2465

PRIVATE OFFICE: Windows, 0-10V Dimming Fixtures 9 npp16 D Local Switch (C405.2.2.3) Lighting Reduction (C405.2.2.2) Sidelight Daylight Zone (C405.2.3.2) ncm PDT 9 ADCX (RJB) CAT-5e Cable Line Voltage Wires Line Power Feed 0-10V Wires 1 npp16 D Relay Module with 0-10V Dimming Output 1 On/Off & Raise/Lower WallPod 1 ncm PDT 9 ADCX (RJB) Dual Technology Occupancy Sensor with Automatic Dimming Photocell OPERATION DETAILS: ADDITIONAL OPTIONS: All fixtures are controlled together Maximum level can be limited to 80% Fixtures must be turned on manually (or optionally can be configured to come on automatically to 50%) Fixtures automatically turn off when room becomes vacant Daylight Control: Smooth continuous dimming Not required for offices without windows or that have loads <150W in sidelight zones Manual Control: On/off & raise/lower control of fixtures Surface or recessed mount sensors also available Room can be connected to nlight backbone For emergency lighting control add a npp16 D ER pack IECC: nlight Applications Guide

10 OPEN OFFICE with nlight Enabled Fixtures Local Switch (C405.2.2.3) EMG EMG CAT-5e Cable Lighting Reduction (C405.2.2.2) Line Voltage Wires Sidelight Daylight Zone (C405.2.3.2) Line Power Feed Enhanced Digital Lighting Controls (C406.4) ncm ADCX (RJB) EM Power Feed 0-10V Wires Note: Not all emergency nlight enabled fixtures require a normal monitoring feed. Refer to data sheet for additional information. 14 2 Various; see Appendix A Various; see Appendix A nlight Enabled Fixture nlight Enabled Fixture with EMG Option 2 On/Off & Raise/Lower WallPod 4 Dual Technology Occupancy Sensor 1 ncm ADCX (RJB) Automatic Dimming Control Photocell OPERATION DETAILS: All fixtures are controlled together or independently Maximum level can be limited to 80% Optional automatic lumen compensation Fixtures must be turned on manually (or optionally can be configured to come on automatically to 50%) Fixtures automatically turn off when room becomes vacant Daylight Control: Smooth continuous dimming Custom grouping of fixtures into separate daylight zones (max. number zones = number of fixtures) Not required for offices without windows or that have loads <150W in sidelight zones Manual Control: Master on/off & raise/ lower control of fixtures Optional individual row control (add npodm 4P DX) ADDITIONAL OPTIONS: Surface or recessed mount sensors also available Add Graphic WallPod (model npod GFX) for individual row and up to 16 scene control Room can be connected to nlight backbone www.acuitycontrols.com 800-535-2465

OPEN OFFICE with 0-10V Dimming Fixtures 11 npp16 D npp16 D ER npp16 D Local Switch (C405.2.2.3) CAT-5e Cable Lighting Reduction (C405.2.2.2) npp16 D Line Voltage Wires Sidelight Daylight Zone (C405.2.3.2) npp16 D Line Power Feed EM Power Feed ncm ADCX (RJB) 0-10V Wires 4 npp16 D Relay Module with 0-10V Dimming Output 1 npp16 D ER Emergency Relay Module with 0-10V Dimming Output 2 On/Off & Raise/Lower WallPod 4 Dual Technology Occupancy Sensor 1 ncm ADCX (RJB) Automatic Dimming Control Photocell OPERATION DETAILS: ADDITIONAL OPTIONS: Each row controlled independently Maximum level can be limited to 80% Fixtures must be turned on manually (or optionally can be configured to come on automatically to 50%) Fixtures automatically turn off when room becomes vacant Daylight Control: Smooth continuous dimming Daylight zones defined by rows Not required for offices without windows or that have loads <150W in sidelight zones Manual Control: Master on/off & raise/ lower control of fixtures Optional individual row control (add npodm 4P DX) Surface or recessed mount sensors also available Add Graphic WallPod (model npod GFX) for individual row and up to 16 scene control Room can be connected to nlight backbone IECC: nlight Applications Guide

12 CONFERENCE ROOM with nlight Enabled Fixtures npodm 2P DX Local Switch (C405.2.2.3) Lighting Reduction (C405.2.2.2) Sidelight Daylight Zone (C405.2.3.2) Enhanced Digital Lighting Controls (C406.4) ncm ADCX (RJB) CAT-5e Cable Line Voltage Wires Line Power Feed 6 Various; see Appendix A nlight Enabled Fixture 1 npodm 2P DX Dual On/Off & Raise/Lower WallPod 1 Dual Technology Occupancy Sensor Options 1 ncm ADCX (RJB) Automatic Dimming Control Photocell OPERATION DETAILS: Each row/fixture controlled independently Maximum level can be limited to 80% Optional automatic lumen compensation Fixtures must be turned on manually (or optionally can be configured to some on automatically to 50%) Fixtures automatically turn off when room becomes vacant Daylight Control: Smooth continuous dimming Custom grouping of fixtures into separate daylight zones (max number zones = number of fixtures) Not required for areas without windows or that have loads <150w in sidelight zones Manual Control: On/off & raise/lower control of two groups of fixtures ADDITIONAL OPTIONS: Surface or recessed mount sensors also available Add npodm 4S for four scene or npod GFX for touch screen control Room can be connected to nlight backbone For emergency lighting control order fixtures with -n80emg or -n100emg option www.acuitycontrols.com 800-535-2465

CONFERENCE ROOM with 0-10V Dimming Fixtures 13 npp16 D npodm 2P DX Local Switch (C405.2.2.3) Lighting Reduction (C405.2.2.2) npp16 D Sidelight Daylight Zone (C405.2.3.2) ncm ADCX (RJB) CAT-5e Cable Line Voltage Wires Line Power Feed 0-10V Wires 2 npp16 D Relay Module with 0-10V Dimming Output 1 npodm 2P DX Dual On/Off & Raise/Lower WallPod 1 Dual Technology Occupancy Sensor Options 1 ncm ADCX (RJB) Automatic Dimming Control Photocell OPERATION DETAILS: ADDITIONAL OPTIONS: Each row controlled independently Maximum level can be limited to 80% Fixtures must be turned on manually (or optionally can be configured to some on automatically to 50%) Fixtures automatically turn off when room becomes vacant Daylight Control: Smooth continuous dimming Daylight zones defined by rows Not required for areas without windows or that have loads <150W in sidelight zones Manual Control: On/off & raise/lower control of each row Surface or recessed mount sensors also available Add npodm 4S for four scene or npod GFX for touch screen control Room can be connected to nlight backbone For emergency lighting control add a npp16 D ER pack IECC: nlight Applications Guide

14 CLASSROOM with nlight Enabled Fixtures ncm ADCX (RJB) CAT-5e Cable Local Switch (C405.2.2.3) Line Voltage Wires Lighting Reduction (C405.2.2.2) EMG EMG Line Power Feed Sidelight Daylight Zone (C405.2.3.2) EM Power Feed Enhanced Digital Lighting Controls (C406.4) nwv PDT 16 npodm 4S DX 0-10V Wires Note: Not all emergency nlight enabled fixtures require a normal monitoring feed. Refer to data sheet for additional information. 10 Various; see Appendix A nlight Enabled Fixture 2 Various; see Appendix A nlight Enabled Fixture with the EMG Option 1 On/Off & Raise/Lower WallPod 1 nwv PDT 16 Dual Technology Wide View Occupancy Sensor Options 1 npodm 4S DX Teacher Station 4 Scene Control Master On/Off & Raise/Lower 1 ncm ADCX (RJB) Automatic Dimming Control Photocell OPERATION DETAILS: Each row/fixture controlled independently Maximum level can be limited to 80% Optional automatic lumen compensation Fixtures must be turned on manually (or optionally can be configured to some on automatically to 50%) Fixtures automatically turn off when room becomes vacant Daylight Control: Smooth continuous dimming Custom grouping of fixtures into separate daylight zones (max number zones = number of fixtures) Not required for areas without windows or that have loads <150W in sidelight zones Manual Control: Master on/off & raise/ lower control of entire room Optional 4 scene control ADDITIONAL OPTIONS: Surface or recessed mount sensors also available Add additional relay pack (model npp16 D) if a white board lighting zone also required Add graphic wallpod (model npod GFX) for individual row and up to 16 scene control Room can be connected to nlight backbone to enable network control or time schedules www.acuitycontrols.com 800-535-2465

CLASSROOM with 0-10V Dimming Fixtures (Distributed Relays) 15 ncm ADCX (RJB) npp16 D CAT-5e Cable Local Switch (C405.2.2.3) npp16 D ER Line Voltage Wires Lighting Reduction (C405.2.2.2) npp16 D Line Power Feed Sidelight Daylight Zone (C405.2.3.2) nwv PDT 16 npp16 D npodm 4S DX EM Power Feed 0-10V Wires 3 npp16 D Relay Module with 0-10V Dimming Output 1 npp16 D ER Emergency Relay Module with 0-10V Dimming Output 1 On/Off & Raise/Lower WallPod 1 nwv PDT 16 Dual Technology Wide View Occupancy Sensor Options 1 npodm 4S DX Teacher Station 4 Scene Control Master On/Off & Raise/Lower 1 ncm ADCX (RJB) Automatic Dimming Control Photocell OPERATION DETAILS: Each row controlled independently Maximum level can be limited to 80% Fixtures must be turned on manually (or optionally can be configured to some on automatically to 50%) Fixtures automatically turn off when room becomes vacant Daylight Control: Smooth continuous dimming Custom grouping of fixtures into separate daylight zones (max number zones = number of fixtures) Not required for areas without windows or that have loads <150W in sidelight zones Manual Control: Master on/off & raise/ lower control of entire room Optional 4 scene control ADDITIONAL OPTIONS: Surface or recessed mount sensors also available Add additional relay pack (model npp16 D) if a white board lighting zone also required Add graphic wallpod (model npod GFX) for individual row and up to 16 scene control Room can be connected to nlight backbone IECC: nlight Applications Guide

16 CLASSROOM with 0-10V Dimming Fixtures (Panel Alternative) ncm ADCX (RJB) Local Switch (C405.2.2.3) Lighting Reduction (C405.2.2.2) npanel 4 CAT-5e Cable Line Voltage Wires Sidelight Daylight Zone (C405.2.3.2) nwv PDT 16 npodm 4S DX Line Power Feed 0-10V Wires 1 npanel 4 Four Relay Module With 0-10V Dimming Output & EM Options 1 On/Off & Raise/Lower WallPod 1 nwv PDT 16 Dual Technology Wide View Occupancy Sensor Options 1 npodm 4S DX Teacher Station 4 Scene Control Master On/Off & Raise/Lower 1 ncm ADCX (RJB) Automatic Dimming Control Photocell OPERATION DETAILS: Each row controlled independently Maximum level can be limited to 80% Fixtures must be turned on manually (or optionally can be configured to come on automatically to 50%) Fixtures automatically turn off when room becomes vacant Daylight Control: Smooth continuous dimming Provides up to three daylight zones, each controlled independently Not required for areas without windows or that have loads <150W in sidelight zones Manual Control: Master on/off & raise/ lower control of entire room Optional 4 scene control ADDITIONAL OPTIONS: Surface or recessed mount sensors also available Add additional relay pack (model npp16 D) if a white board lighting zone also required Add graphic wallpod (model npod GFX) for individual row and up to 16 scene control Room can be connected to nlight backbone For emergency lighting control add a Voltage Barrier to npanel 4 www.acuitycontrols.com 800-535-2465

STAIRWELL with 0-10V Dimming Fixtures 17 npp16 D ncm 10 (RJB) CAT-5e Cable Line Voltage Wires Line Power Feed 0-10V Wires 1 npp16 D Relay Module with 0-10V Dimming Output 1 ncm 10 (RJB) PIR Extended Range Occupancy Sensor OPERATION DETAILS: Maximum level can be limited to 80% Fixtures automatically go to full bright when occupied Fixtures automatically turn off or optionally can be configured to drop to low dim setting when space becomes vacant ADDITIONAL OPTIONS: Surface or recessed mount sensors also available Room can be connected to nlight backbone For emergency lighting control add a npp16 D ER pack For sidelight/toplight daylight zones with a load >150W, add ncm ADCX (RJB) for daylight control (C405.2.3.1/2) IECC: nlight Applications Guide

18 LOBBY with nlight Enabled Fixtures ncm PDT 10 ADCX (RJB) Sidelight Daylight Zone (C405.2.3.2) Enhanced Digital Lighting Controls (C406.4) CAT-5e Cable Line Voltage Wires Line Power Feed 0-10V Wires 4 Various; see Appendix A nlight Enabled Fixture 1 ncm PDT 10 ADCX (RJB) Dual Technology Extended Range Occupancy Sensor with Automatic Dimming Photocell OPERATION DETAILS: ADDITIONAL OPTIONS: All fixtures are controlled together or independently Maximum level can be limited to 80% Optional automatic lumen compensation Fixtures automatically go to full bright when occupied Fixtures automatically turn off or optionally can be configured to low dim setting when space becomes vacant Daylight Control: Smooth continuous dimming Custom grouping of fixtures into separate daylight zones (max. number of zones = number of fixtures) Not required for spaces without windows or that have loads <150W in sidelight zones Surface or recessed mount sensors also available Space can be connected to nlight backbone For emergency lighting control, order fixtures with n80emg or n100emg option www.acuitycontrols.com 800-535-2465

LOBBY with 0-10V Dimming Fixtures 19 npp16 D ncm PDT 10 ADCX (RJB) Sidelight Daylight Zone (C405.2.3.2) CAT-5e Cable Line Voltage Wires Line Power Feed 0-10V Wires 1 npp16 D Relay Module with 0-10V Dimming Output 1 ncm PDT 10 ADCX (RJB) Dual Technology Extended Range Occupancy Sensor With Automatic Dimming Photcell OPERATION DETAILS: ADDITIONAL OPTIONS: All fixtures are controlled together Maximum level can be limited to 80% Fixtures automatically go to full bright when occupied Fixtures automatically turn off or optionally can be configured to drop to low dim setting when space becomes vacant Daylight Control: Smooth continuous dimming Not required for spaces without windows or that have loads <150W in sidelight zones Surface or recessed mount sensors also available Space can be connected to nlight backbone For emergency lighting control add a npp16 D ER pack IECC: nlight Applications Guide

20 PRIVATE / SINGLE RESTROOM with nlight Enabled Fixture Local Switch (C405.2.2.3) nwsx PDT LV DX Lighting Reduction (C405.2.2.2) Enhanced Digital Lighting Controls (C406.4) CAT-5e Cable Line Voltage Wires Line Power Feed 1 Various; see Appendix A nlight Enabled Fixture 1 nwsx PDT LV DX Dual Technology Occupancy Wall Switch w/ Raise/ Lower OPERATION DETAILS: ADDITIONAL OPTIONS: Maximum level can be limited to 80% Optional automatic lumen compensation Fixtures automatically go to full bright when occupied (or optionally can be configured to come on automatically to 50%) Fixtures automatically turn off when space becomes vacant Manual Control: On/off & raise/lower control of fixtures Surface or recessed mount sensors also available Space can be connected to nlight backbone For emergency lighting control order fixtures with -n80emg or -n100emg option www.acuitycontrols.com 800-535-2465

PRIVATE / SINGLE RESTROOM with Switching Only Fixture 21 npp16 Local Switch (C405.2.2.3) nwsx PDT LV CAT-5e Cable Line Voltage Wires Line Power Feed 1 npp16 Relay Pack 1 nwsx PDT LV Dual Technology Occupancy Wall Switch OPERATION DETAILS: ADDITIONAL OPTIONS: Switching only, no dimming Fixtures automatically turn on when occupied Fixtures automatically turn off when space becomes vacant Manual Control: On/off control of fixtures Surface or recessed mount sensors also available Space can be connected to nlight backbone For emergency lighting control add a npp16 ER pack IECC: nlight Applications Guide

22 PUBLIC RESTROOM with nlight Enabled Fixtures Local Switch (C405.2.2.3) Lighting Reduction (C405.2.2.2) Enhanced Digital Lighting Controls (C406.4) CAT-5e Cable Line Voltage Wires Line Power Feed (Each Restroom) 2 Various; see Appendix A nlight Enabled Fixture 1 On/Off & Raise/Lower WallPod 2 Dual Technology Occupancy Sensor OPERATION DETAILS: ADDITIONAL OPTIONS: All fixtures are controlled together or independently (per room) Maximum level can be limited to 80% Optional automatic lumen compensation Fixtures automatically go to full bright when occupied (or optionally can be configured to come on automatically to 50%) Fixtures automatically turn off when room becomes vacant Manual Control: On/off & raise/lower control of fixtures (per room) Surface or recessed mount sensors also available Room can be connected to nlight backbone For emergency lighting control order fixtures with -n80emg or -n100emg option www.acuitycontrols.com 800-535-2465

PUBLIC RESTROOM with 0-10V Dimming Fixtures 23 Local Switch (C405.2.2.3) Lighting Reduction (C405.2.2.2) npp16 D npp16 D CAT-5e Cable Line Voltage Wires Line Power Feed 0-10V Wires (Each Restroom) 1 npp16 D Relay Module with 0-10V Dimming Output 1 On/Off & Raise/Lower WallPod 2 Dual Technology Occupancy Sensor OPERATION DETAILS: ADDITIONAL OPTIONS: All fixtures are controlled together (per room) Maximum level can be limited to 80% Fixtures automatically go to full bright when occupied (or optionally can be configured to come on automatically to 50%) Fixtures automatically turn off when room becomes vacant Manual Control: On/off & raise/lower control of fixtures (per room) Surface or recessed mount sensors also available Room can be connected to nlight backbone For emergency lighting control add a npp16 D ER pack IECC: nlight Applications Guide

24 CORRIDOR with nlight Enabled Fixtures ncm 10 (RJB) ncm 10 (RJB) Enhanced Digital Lighting Controls (C406.4) ncm 10 (RJB) ncm 10 (RJB) CAT-5e Cable Line Voltage Wires Line Power Feed 9 Various; see Appendix A nlight Enabled Fixture 4 ncm 10 (RJB) Extended Range PIR Occupancy Sensor OPERATION DETAILS: ADDITIONAL OPTIONS: All fixtures are controlled together or independently Maximum level can be limited to 80% Optional automatic lumen compensation Fixtures automatically go to full bright when occupied Fixtures automatically turn off or optionally can be configured to drop to low dim setting when space becomes vacant Surface or recessed mount sensors also available Space/zone can be connected to nlight backbone to enable network control or time schedules For emergency lighting control order fixtures with -n80emg or -n100emg option For sidelight/toplight daylight zones with a load >150W, add ncm ADCX (RJB) for daylight control (C405.2.3.1/2) www.acuitycontrols.com 800-535-2465

CORRIDOR with 0-10V Dimming Fixtures 25 ncm 10 (RJB) npp16 D ncm 10 (RJB) ncm 10 (RJB) ncm 10 (RJB) CAT-5e Cable Line Voltage Wires Line Power Feed 0-10V Wires 1 npp16 D Relay Module with 0-10V Dimming Output 4 ncm 10 (RJB) Extended Range PIR Occupancy Sensor OPERATION DETAILS: ADDITIONAL OPTIONS: All fixtures are controlled together Maximum level can be limited to 80% Fixtures automatically go to full bright when occupied Fixtures automatically turn off or optionally can be configured to drop to low dim setting when space becomes vacant Surface or recessed mount sensors also available Space/zone can be connected to nlight backbone to enable network control or time schedules For emergency lighting control add a npp16 D ER For sidelight/toplight daylight zones with a load >150W, add ncm ADCX (RJB) for daylight control (C405.2.3.1/2) IECC: nlight Applications Guide

26 nlight Networked Lighting Control: Programmable Timeclock Programmable Timeclock Control: Bridge Gateway2 Although not pictured within each of 1 2 3 the individual room design guides, each nlight Control Zone can be connected via an nlight backbone to create a networked nlight lighting control system capable of meeting the requirements of the IECC programmable timeclock provision (Section C405.2.2.1). A networked system also enables astronomical time clock control. npp20 PL For additional information regarding building management integration or demand response features, please ncm ADCX (RJB) ncm ADCX (RJB) contact your Acuity Brands Sales Representative. CAT-5e Cable Line Voltage Wires Line Power Feed 0-10V Wires 1 nbrg 8 KIT 8-Port Backbone Bridge 1 ngwy2 KIT Network Gateway Controller www.acuitycontrols.com 800-535-2465

APPENDIX A: nlight Enabled Fixtures 27 Product Family Fixture Series Notes Product Family Fixture Series Notes Lithonia Lighting AC Series LED Recessed Mark Architectural Lighting Slot 4 LED Pendant, Wall, Surface, Recessed Lithonia Lighting AL Series LED High Performance Architectural Recessed Mark Architectural Lighting Slot 6 LED Recessed Lithonia Lighting ALLS LED Surface Mount Lithonia Lighting AVLED Avante LED Recessed - Direct/Indirect Lithonia Lighting BZL Series LED Recessed Indirect Lithonia Lighting FSL Series LED Recessed Lithonia Lighting RT Series LED Recessed Volumetric Lithonia Lighting T Series LED Recessed Troffer Lithonia Lighting VT Series LED Recessed Volumetric Lithonia Lighting GT Series General Recessed Troffer Lithonia Lighting SBS Series LED Shadow Box Square Lithonia Lighting WL Series LED Wall Bracket Surface Mount Lithonia Lighting RTLX LED Surface Volumetric Lithonia Lighting ST LED LED Surface Volumetric Lithonia Lighting IBL / IBH LED Highbay Lithonia Lighting PTN LED Highbay - Proteon Lithonia Lighting LDN Downlight Lithonia Lighting ACLX AC Series Surface Mount Lithonia Lighting RTLR LED Relight Volumetric Recessed Mount Lithonia Lighting RTLEDRT Relight Volumetric for Lensed Troffers Lithonia Lighting SBS LX LED Relight Shadow Box Square Lithonia Lighting T LX LED Relight Surface Mount Lithonia Lighting VTL RT LED LED Relight Lensed Troffers Mark Architectural Lighting Fin LED Recessed Mark Architectural Lighting Whisper LED Recessed Mark Architectural Lighting Nol LED Recessed Mark Architectural Lighting SPR LED Perimeter Peerless Vellum LED Suspended, Recessed Peerless Mino LED Recessed Peerless Round 2/4 LED Suspended, Wall Peerless Square LED Suspended, Wall Peerless Origami LED Suspended, Wall Peerless Bruno LED Suspended, Wall Peerless Staple Suspended, Wall Peerless Lightline, Indirect Suspended Peerless Lightedge Suspended Peerless Icetray Suspended Peerless Cerra Suspended Peerless Prima Suspended Peerless Naro Suspended Peerless Tulip Suspended Peerless Envision Suspended Peerless Aero Suspended Peerless Enzo Suspended Lithonia Lighting VTLR LED LED Relight Parabolic Lensed Lithonia Lighting VTLX LED Relight Volumetric Surface Mount Gotham EVO LED Downlight Gotham Incito LED Downlight Note: New nlight enabled fixtures are added regularly. Please reference fixture spec sheets for nlight enabled options. IECC: nlight Applications Guide

28 APPENDIX B: Requirements Overview Control Requirement Code Provision Code Summary* Recommendations for Compliance nlight Solution Details nlight WallPod devices provide a user with local control of lighting within an nlight controlled space (i.e. nlight zone). WallPods are available in multiple styles each with varying features and user experience. Push-Button WallPod Graphic WallPod Local Switch C405.2.1.3 Areas shall incorporate a manual control to allow occupants to turn fixtures off. Include manual control device(s) in all room control system designs Traditional tactile buttons and LED user feedback. Full color touch screen provides a sophisticated look and feel. Individual nlight Control Zones (ie rooms) can be easily networked together across an entire building simply by connecting them into a backbone made up of one or more nlight Bridge devices and an nlight Gateway. The Gateway provides programmable time clock functionality for an nlight network as well as interfaces to the SensorView Suite of web-based software applications (via an Ethernet LAN / WAN connection). Shut-Off Control Programmable Timeclock C405.2.2.1 Each area of the building not provided with occupant sensor controls shall be provided with time switch controls. These areas must also be provided with a manual override switch. Utilizing controls capable of being networked across an entire building enables simple compliance via a single central programmable time clock. Network Gateway Additional benefits of installing an nlight backbone include remote status monitoring, ios smartphone app control, and BMS interface capability Full Auto-Off via Occupancy Sensor C405.2.1.1.1 Fixtures must automatically turn off within 30 minutes of all occupants leaving the space. Always include occupancy sensors in all control system designs regardless of lighting type. nlight occupancy sensors utilize 100% digital passive infrared (PIR) detection, come in several mounting styles, and offer multiple coverage pattern options. Additionally, nlight sensors are available with patented Microphonics TM dual technology detection for rooms with obstructions. Configuring for full off vs. partial off control is done with system programming. Manual-On, Partial-On, Full Automatic On C405.2.1.1.2 Automatically controlled spaces must be controlled to either turn the lighting on to not more than 50%, or in certain spaces, to full on. Always include occupancy sensors in all control system designs. Reducing the level of dimmable fixtures to 50% is easiest method of compliance, however turning off 50% of lighting via circuit switching is also an option. 360 Occupancy Sensor 120 WideView Corner Sensor Surface or recessed mounts to ceiling tiles or sheetrock/plaster. Directly mounts in corner or to ceiling via repositionable ceiling bracket. * Note: This summary is for general information purposes only and is provided without any warranty as to accuracy, completeness, or otherwise. The user should read the applicable code sections for more complete and detailed descriptions of code requirements and exceptions and should consult with a professional engineering or other competent advisor before making any decision or taking any action based on this summary. www.acuitycontrols.com 800-535-2465

APPENDIX B: Requirements Overview 29 Control Requirement Code Provision Code Summary* Recommendation for Compliance nlight Solution Details nlight provides multiple options for controlling continuous dimming luminaires. This allows spaces with several lighting types and technologies to be controlled together and with a common user experience. nlight enabled Acuity Brands Fixtures Dimming Relay Packs / Panels Manual Lighting Reduction C405.2.2.2 Spaces shall have a manual control that allows the occupant to reduce the connected lighting load uniformly by at least 50%. Continuously dimmable LED (or fluorescent) fixtures and manual dimming controls are the easiest method of compliance. Light Level Control Daylight- Responsive Controls C405.2.3.1/2 Daylight-responsive controls shall be provided within each space with sidelight and toplight daylight zones. Automatic daylight harvesting photocells that continuously adjust the level of dimming fixtures according to daylight levels provide the most effective and least distracting control. Acuity offers a wide variety of LED fixtures with factory installed integrated nlight controls that provide smooth continuous dimming, and optional automatic lumen maintenance or manual task tuning. nlight dimming relay packs / panels enable control of any 0-10VDC dimmable LED (or fluorescent) luminaire. Manual task tuning control can also be used. nlight offers standalone daylight harvesting sensors as well as occupancy sensors with integrated daylight harvesting. Sensors are available in four different housings and provide continuous dimming control of any/all networked nlight enabled fixtures or dimming relay packs, each capable of being its own daylight zone. Ceiling Mount Dimming Photocell Recessed Mount Dimming Photocell * Note: This summary is for general information purposes only and is provided without any warranty as to accuracy, completeness, or otherwise. The user should read the applicable code sections for more complete and detailed descriptions of code requirements and exceptions and should consult with a professional engineering or other competent advisor before making any decision or taking any action based on this summary. IECC: nlight Applications Guide

Additional Resources: Acuity Controls Typical Layout Drawings http://www.acuitybrands.com/typicals IECC http://www.iccsafe.org/ Use the Following Sections of the IECC-2015 Code as Reference: Section C405.2.1.1.1 Sensor Section C405.2.1.1.2 Manual-On or Partial-On Section C405.2.1.1.2 Full Automatic On Section C405.2.1.3 Local Switch Section C405.2.2.1 Programmable Timeclock Section C405.2.2.2 Manual Lighting Reduction Section C405.2.3.1/2 Daylight-Responsive Controls Section C406.4 Enhanced Digital Lighting Controls One Lithonia Way Conyers, Georgia 30012 Phone: 800.535.2465 2015 Acuity Brands Lighting, Inc. All rights reserved. 04/15 10/15 SSI_1832 SSI_2026