Effective ventilation is necessary for the comfort

Similar documents
This month we are discussing the basics of

REQUIREMENTS FOR HOOD PLANS

Contents Chapters 4 & 5 of the 2012 Michigan Mechanical Code CHAPTER 4, MMC: VENTILATION CHAPTER 5, MMC: EXHAUST SYSTEMS

Design Guide Improving Commercial Kitchen Ventilation System Performance

MECHANICAL EXHAUST VENTILATION SYSTEMS OPERATIONAL GUIDELINES-REVISED 2003

Demand Control Ventilation What, When and Where?

for commercial kitchen ventilation

LABEL PLEASE NOTE: ALL APPLICATIONS AND SITE PLANS MUST BE COMPLETED IN BLACK OR BLUE INK ONLY

Basic Hood Considerations The design process for a successful kitchen ventilation system starts when the engineering design HVAC team receives

Lombard Fire Department Bureau of Fire Prevention COMMERCIAL HOOD & DUCT SYSTEMS

FOUNDATIONS OF MODERN KITCHEN VENTILATION (CKV) DESIGN HANDBOOK

Halton - Meeting the Kitchen Ventilation challenges of multiple venues in Hotels, Casinos and Resorts

2012 ICC Commercial Kitchen Hoods

90.1 and Designing High Performance Commercial Kitchen Ventilation Systems BY DON FISHER, P.ENG., RICH SWIERCZYNA,

Mobile Vendors Bulletin

MECHANICAL EXHAUST VENTILATION SYSTEMS FOR RETAIL FOOD FACILITIES. Design, Calculations, and Operational Guidelines

MSYS 4490 AC Systems

APPLICATION FOR EXEMPTION FROM MECHANICAL VENTILATION

CHAPTER 5: EXHAUST SYSTEMS

2015 ICC Commercial Cooking Systems

GUIDELINES FOR HIGHRISE BUILDING CONSTRUCTION PROJECTS (MECHANICAL VENTILATION)

Commercial Kitchen Ventilation (CKV) Design and Recent Innovations and Developments in the Industry.

Effects of Kitchen Ventilation on Residential Dwellings

Kitchen Ventilation Hood Permit Application

Demand-Controlled Ventilation for Commercial Kitchen Ventilation

Notable Changes in the Mechanical Codes

SECTION COMMERCIAL-KITCHEN HOODS

The Enviro-Clean Air Scrubber keeps the Atmosphere Clear and Creates Clean Air

MINNESOTA COMMERCIAL KITCHEN

Biosafety Cabinets and Fume Hoods Supplemental Material (OHS_BIO304)

Project Name: Project Address: Installer Name: Installer Address: Date of Inspection:

Kieffer s Buying Guide: Wall Ovens

Ventilation System Description. September 8, 2000 HETA

PDH & Professional Training

Commercial Kitchen Exhaust Requirements Kitchen Exhaust for Food Service Operations

MODEL: JRSVH SERIES JEAN S RESTAURANT SUPPLY 426 SOUTH STAPLES CORPUS CHRISTI, TEXAS PH: (361)

Innovative Technologies [and Design Concepts] in Commercial Foodservice

COMMERCIAL KITCHEN SUPPRESSION SYSTEMS INFORMATION PACKET

MECHANICAL VENTILATION

BETTER BUILDINGS BY DESIGN CONFERENCE 2008 Designing a Sustainable Commercial Kitchen FEBRUARY 13 BURLINGTON, VERMONT

Introduction to the Exhaust Fan Interceptor Commercial Exhaust Fans from a Service Perspective

Combustion Safety. RESNET Conference San Antonio, TX February 27, Presented by Rich Moore Lightly Treading Energy & Design Denver, CO

MECHANICAL EXHAUST VENTILATION SYSTEMS Design, Calculations, and Operational Guidelines

Land Use and Environmental Service Agency (Code Enforcement) NC Mechanical Code. Table of Contents

Customer Advanced Technologies Program Technology Evaluation Report

Home Performance Science

Displacement Ventilation

Food Service Plan Review Information

Ventilation Guidelines

Land Use and Environmental Service Agency (Code Enforcement) Mechanical Q&A 2009

IMC Significant Changes Summary Tier I

Chapter One Commercial Kitchen Fires

DOWNDRAFT BENCH SERIES

To expedite the plan review and inspection processes, please refer to the information below.

Demand-Controlled Ventilation For Commercial Kitchens

Challenges and Methods of Estimating a Conceptual HVAC Design

2015 & 2012 International Mechanical Code Significant Changes and the PA Uniform Construction Code

Commercial Kitchen Ventilation Services. Ventilation Systems. Canopies. Ductwork. Gas Interlock Systems

Air Purification Systems. Clearing the Air. Air Purification Systems. Air Purification Systems

FRESNO COUNTY HUMAN SERVICES SYSTEM ENVIRONMENTAL HEALTH SYSTEM P.O. Box Fresno, CA Telephone (209)

RFMA 2016 March 13 15, 2016

Sentry Air Systems, Inc.

THE EVALUATION OF MULTI-ZONE AIR FLOW PATTERN AND VENTILATION RATES WITH TRACER GAS METHODS IN APARTMENT HOUSE

SYSTEM SOLUTIONS SCHOOLS

Breathe Easy With. Out. Out 54 FINE HOMEBUILDING. COPYRIGHT 2014 by The Taunton Press, Inc. Copying and distribution of this article is not permitted.

Building Science Basics

Kitchenology: Tales of Transformation and Efficient and Effective Operations

Land Use and Environmental Service Agency (Code Enforcement) Mechanical Q&A 2009

Owner s Guide Installation & Operation

Minimum Information Required to Process your Special Occasion Application. Parking area Access to site

FEMA Recommendations for Protection of Curtained Limited Finishing Workstations using UL 1254 Listed Pre engineered Dry Chemical Systems

Plus Perimeter Aspiration Timer Remote control predisposition

GLOBAL FINISHING SOLUTIONS

Re: AHRI Comments on Proposed Addendum be to ASHRAE Standard 189.1

Variable Ventilation for the Kitchen:

ESPAIR E AIRTM ESPA ESPAIRTM. Kitchen Exhaust Air Treatment System KET Series.

AUTOMATIC MAKE-UP AIR DAMPER WITH TRANSFORMER READ AND SAVE THESE INSTRUCTIONS

Low Wall Back Shelf Exhaust Canopy

FOOD SERVICE EQUIPMENT REBATES

Dear Concessionaire,

Gil Rossmiller. In the construction industry for over 30 years. ICC IRC Plumbing & Mechanical Code Development Committee

Comparative Matrix A Comparison of the NFPA 96 and ICC Standards and Codes with regard to Commercial Kitchen Systems

Senior Thesis Centre Community Hospital East Wing Addition - Proposal Keith Beidel Mechanical Option 12/05/02 1

NFPA 96, 2017 REVIEW SUMMARY

BEST PRACTICE RECOMMENDATIONS

tççç= ÜÉ~íáåÖ çéíáçåë

SERIES: FC & IL FORNO CLASSICO BUILT BY CRAFTSMEN. TESTED BY TIME.

2012 International Mechanical Code Significant Changes. About the Significant Changes

COMMERCIAL KITCHEN FIRE SAFETY

Ventilation for New Low-Rise Residential Buildings July 20, 2015

SPECIAL EVENTS INSTRUCTIONS AND REQUIREMENTS Must apply at least 2 weeks PRIOR to Event Date

Equipment Layout Manual. For Cooling Towers, Evaporative Condensers & Closed Circuit Coolers

CORPUS CHRISTI FIRE PREVENTION MOBILE FOOD VENDOR REQUIREMENTS

ENVIRO UNIT ENGINEERING MANUAL KES SERIES

PERFECT HEATING, COOLING, AND VENTILATION

incorporating Contractors guide to car park ventilation A no-nonsense guide to the safe ventilation of underground and covered car parks

FOOD ESTABLISHMENT CONSTRUCTION GUIDE Revised December 19, 2011 Reviewed January 10, 2014

TR Series - The Ultimate ERV

WALK-AROUND INSPECTION LIST

INFRARED RADIANT HEATERS

Transcription:

NEWS FROM THE NETWORK Understanding Kitchen Ventilation Clearing the Air and Eliminating the Myths by Tom Stroozas CFE, RCGC, CFSP GFEN Consulting Editor Effective ventilation is necessary for the comfort of occupants in any enclosed space. In the foodservice industry, with its array of various types of cooking equipment, a properly performing exhaust system is essential to deal with the effects of heat, cooking effluent (grease & smoke), odors, moisture, pollutants and other airborne contaminants. Without adequate ventilation, cooking in confined spaces would be difficult if not impossible. The amount of ventilation required in a particular cooking area depends on various factors: the type product(s) being cooked, the cooking environment, the type of equipment used, and local code regulations. Depending on where you are located, the building heat source may also play a factor. The Importance of Ventilation Ventilation is the single most important factor in the design, construction and operation of today s commercial kitchens. Without adequate ventilation and an ample supply of clean make-up air, no kitchen will operate efficiently. To ensure proper ventilation, you must consider the following: National, regional and local codes are becoming increasingly strict; Environmental standards are being tightened to require even cleaner exhaust; Increasing costs are forcing the industry to find innovative means to provide lower cost installation, start-up, and improved operating efficiencies.

The Cooking Equipment Factor The type of cooking that a restaurant does and the equipment used has a direct influence on the design and horsepower of the ventilation system requirements for any given facility. Some kitchens will use more ventilation energy than others simply because of the type of cooking appliance receiving the most use. For example, fryers, charbroilers and griddles release high amounts of pollutants. Steamers and combi ovens release super-heated steam when the doors are opened which adds to the complexity of proper ventilation designs. A Look at Hoods Over the years, terminology has developed that defines the hood types and designs. Some common terms include backshelf, canopy (island or wall), recirculating (self-contained ductless for electric equipment only), SP (supply plenum), CFM (cubic feet per minute) and MUA (make-up air). Hood size is determined by the capacity and size of the cooking equipment. The capacity of the hood itself is expressed in CFMs, and is determined by two primary factors: 1. The type of cooking equipment in use: fryers, charbroilers, etc. 2. Air flow restrictions: walls, fabricated enclosures, etc. These factors define the velocity and rate of expansion of the air in the generated updraft. Appliances with large, heat-radiating surfaces like charbroilers and grills produce a stronger updraft than say, an oven, which releases less of the heat it produces. The kitchen walls, fabricated enclosures and the type of hood system used determines how much exhaust air is needed. The more enclosed the cooking equipment, the less exhaust is needed for proper ventilation. An appliance that is open on all sides requires more exhaust volume than one where only one side is open. Backshelf or Canopy There are a number of variations for both backshelf and canopy hoods. Your menu and cooking appliances will dictate which system design is best. Backshelf hoods are best suited for low cooking surface appliances, i.e griddles, grills, fryers, etc. Placing this type of hood in close proximity to the cooking surface requires less exhaust than a canopy hood used in the same application. This makes the backshelf hood a good choice for cooking environments such as quick-serve and short-order foodservice establishments. The backshelf hood is not suitable for tall appliances or equipment that produce large volumes of effluent or steam such as steamers and ovens. For such applications a canopy hood is essential. Canopy hoods require larger volumes of exhaust air than the backshelf design. As a result, they are more suitable for ventilating any type of cooking operation and are more flexible as to where they are placed; for example, next to a wall or placed in the center of the kitchen with a 360 island style cooking radius. For that reason, canopy hoods are the predominant system used in foodservice facilities today. Canopy Hood Sizing There are three important issues to be mindful of when determining hood size: 1. Cooking equipment layout: Most applications require a six inch overhang on each side of the cooking equipment surface, except for charbroilers, which require a 12 inch overhang. For island canopy configurations, the increased hood overhang is proven to be one of the most effective performance enhancements. 2. Wall locations: Determine the wall locations around the hood perimeter. If the cooking 6 COOKING FOR PROFIT comes to you compliments of your gas energy provider / January 2015

equipment is against a back wall and in the corner, the hood would require a six inch overhang on the front of the equipment and a six inch overhang on one end only. If the hood is to be open on both ends, then a six inch overhang must be allowed for each end. 3. Height limitations: The ceiling will determine the height of the hood with the front lip generally placed 78 inches above the floor. Although there are no minimum height requirements, it is recommended that at least 75 inches above the floor be used to provide adequate working clearance and headroom. 4. Island canopy hood differences: Many larger restaurants with display cooking configurations and institutional establishments will incorporate the island canopy configuration as a means to maximize production space and logistics. Recent tests conducted by the Food Service Technology Center (FSTC) ASHRAE Research Project 1480 confirmed that single-island canopy hoods require much higher exhaust rates than their wall-mounted counterparts to effectively ventilate cooking equipment for a given duty class. For example, while an exhaust rate of 300 to 400 CFM per linear foot can be adequate for capture and containment with a wall-mounted canopy hood over a heavy-duty cooking line, a single-island canopy hood may require an exhaust rate in excess of 500 CFM per linear foot in many situations (measured along one side of the canopy hood). In fact, there were several test scenarios for single-island hoods where an exhaust rate in excess of 700 CFM was required to achieve proper capture and containment. This contradicts common design practice wherein the specified ventilation rates are often much closer to those for wall-canopy hoods. Air Flow & Make-Up Air Every commercial kitchen requires make-up air to compensate for the air exhausted from the cooking environment. It is also essential in order to maintain a comfortable working environment. Make-up air is often supplied by the building HVAC system, but in the long run this is somewhat expensive and inefficient. Make-up air may also be extracted from the HVAC system in the kitchen area or it can be integrated into the hood itself, which is commonly known as a short circuit system. There are many misconceptions that taking air from a conditioned space within the kitchen area is inferior to incorporating a short circuit type system integrated into the hood. This assumption is incorrect. Given the fact that a hood that incorporates its own make-up air system can cost up to twice as much as a capture only hood, we have seen a significant decline in the sales of this once popular integrated design. Smoke tests have proven the effectiveness of capture only systems that pull make-up air from the room where it is employed. Remember the objective here is to provide a clean and comfortable cooking environment. A less expensive, capture only hood with make-up air drawn from the kitchen area, can prove to be the preferred way of clearing the air and reducing the expense of the hood design. With a double-island canopy configuration, however, when local make-up air was introduced aggressively through 4-way diffusers, perforated diffusers, or a high-flow perforated perimeter supply system, hood performance was drastically reduced. For double-island canopy configurations, tests showed that it is best to operate the perforated perimeter supply system with low-flow at a low velocity. Tests also showed that higher replacement air temperatures from ceiling diffusers degraded the performance of island hoods. Unbalanced replacement air distribution COOKING FOR PROFIT comes to you compliments of your gas energy provider / January 2015 7

Wall Mounted Canopy Double Island Canopy was extremely detrimental to the performance of the double-island hoods. For areas with colder climates, many manufacturers offer direct-fired, heated make-up air (MUA) systems. These gas MUA packages are designed to deliver tempered make-up air for installations requiring frequent air changes. Units are designed for natural gas and propane gas applications, and for indoor or outdoor installation. Proper Ventilation Is Essential Cooking produces heat, odors, smoke, vapors, grease and other pollutants. When a ventilation system breaks down, the cooking environment can soon become a very uncomfortable place to work. A constant supply of fresh and clean air is essential. The ventilation system must exhaust the heat produced, as well as the moisture and cooking effluents. A kitchen that produces light snacks, sandwiches and salads produces less heat and odors than those cooking heavier items such as steaks, burgers and fries. All cooking equipment must be allowed to breathe. Proper air flow is required not only for combustion, but also to exhaust fumes and odors and prevent heat and moisture build-up in equipment controls. Too much exhaust can suck the heat out of an oven, preventing it from cooking properly. Too little can cause controls and electronic components to overheat and fail. Knowing what your cooking equipment requires is critical to its performance and operating life. Another reason for proper and efficient ventilation is the need to maintain a somewhat negative pressure in the kitchen area 20% is a general rule of thumb. Negative pressure means drawing air into the kitchen space atmosphere to contain the odors and effluents that a foodservice operation produces. Kitchens that operate under a positive pressure have a tendency to push the cooking odors and effluents out of the kitchen and into the dining area. If you have ever walked into a restaurant that felt humid and smelled of food odors you know how unacceptable that is. It is especially unacceptable in places of shared common space, i.e. mall food courts, hotels, and office buildings where the operator desires a facility with fresh air and no cooking odors. As mentioned earlier, while the system design depends on the type of cooking equipment being used, this is just one factor. The use of kitchen space is another. Regardless of the source of make-up air, it is necessary that whoever designs your system calculate the make-up air required for your facility. This is directly related to the type of cooking you do (your menu items) and related building restrictions. Some considerations when calculating make-up air are: Minimize make-up air velocities; Maintain a slight negative pressure in the kitchen 20% rule of thumb; Comply with local code jurisdictions. Single Island Canopy Back Shelf All Cooking Equipment Needs Venting Have you ever walked into a kitchen and noticed yellowed ceiling tiles and found that there was an 8 COOKING FOR PROFIT comes to you compliments of your gas energy provider / January 2015

unvented electric oven being used? Often operators are told by an uninformed equipment salesperson that electric ovens may be used as an unvented appliance since they do not emit by-products of combustion and will only be used for baking breads and pastries. But operators beware codes state that cooking appliances that emit heat, moisture and grease laden vapors must be vented using a Type I hood (liquidtight construction with built-in fire suppression). Appliances that emit only heat and moisture such as warewashers still must be vented using a Type II hood (without built-in fire suppression). Employing electric ovens without hoods is a code violation. Knowing this eliminates any perceived advantage to using an electric oven especially when a gas oven will cook better and more economically. Remember, if your equipment produces heat and moisture, it must be vented with a Type II hood; and if it emits grease laden vapors because of the product being cooked, you must employ a Type I hood. Understanding the facts puts gas and electric equipment on a level playing field when it comes to ventilation. Help for Poor Performing Hoods Over the years, I have been asked for ways to improve some of the problems common to many of the asbuilt hood systems in use today. Here are a few workable tips: If you have a short circuit hood (integrated makeup air) you can improve the capture without increasing the make-up fan speed by moving it to the back of the kitchen. Simply have your mechanical contractor redirect your make-up air so that it travels across the kitchen and you will see a dramatic improvement with your hood s performance. Incorporate the use of side panels that can be installed on the open sides of your present exhaust hood system. This will in effect, create a larger chamber for the hood to draw from and improve your overall system efficiency. These panels can be made very economically from stainless steel or Plexiglas. Push your equipment back. In the case of a wall or canopy type configuration, this will allow for more overhang and increase the overall size of the reservoir to capture, contain and exhaust cooking effluent, heat and vapors. The FSTC report cited earlier, ASHRAE Research Project 1480, proved that increasing hood overhang provides the best performance enhancement for island canopy hoods. And increased overhang can decrease the required amount of exhaust for a given hood cooking line. Pre-Engineered Systems There are many manufacturers of commercial kitchen ventilation systems that produce a variety of hood designs. You may purchase a fully integrated package that is pre-engineered for optimum performance. In the 33rd Edition of the Foodservice Gas Equipment Catalog, published by Cooking For Profit, you will see many examples of modern kitchen ventilation systems. Visit www.gfen.com for a look at these systems via the new user-friendly digital editon. A properly designed and operating kitchen ventilation system will make your foodservice facility more comfortable for your employees and your customers and contribute to your overall bottom line. Remember, good ventilation is good for your business! To learn more about other ways natural gas can benefit your foodservice operation, log onto the Gas Foodservice Equipment Network at www.gfen.com. COOKING FOR PROFIT comes to you compliments of your gas energy provider / January 2015 9