SUBMITTAL DATA: PLA-A12EA7 & PUZ-A12NKA7(-BS) 12,000 BTU/H CEILING-CASSETTE HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A12NKA7

Similar documents
SUBMITTAL DATA: PLA-A36EA7 & PUZ-A36NKA7(-BS) 36,000 BTU/H CEILING-CASSETTE HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A36NKA7

SUBMITTAL DATA: PLA-A24EA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H CEILING-CASSETTE HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUY-A24NHA7

SUBMITTAL DATA: PEAD-A12AA7 & PUZ-A12NKA7(-BS) 12,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A12NKA7

SUBMITTAL DATA: PCA-A24KA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H CEILING-SUSPENDED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A24NHA7

SUBMITTAL DATA: PEAD-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A42NKA7

SUBMITTAL DATA: PEAD-A30AA7 & PUZ-A30NHA7(-BS) 30,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A30NHA7

SUBMITTAL DATA: PVA-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A42NKA7

SUBMITTAL DATA: PEAD-A24AA7 & PUY-A24NHA7(-BS) 24,000 BTU/H HORIZONTAL-DUCTED AIR-CONDITIONING SYSTEM. Job Name: System Reference:

SUBMITTAL DATA: PVA-A36AA7 & PUY-A36NKA7(-BS) 36,000 BTU/H AIR HANDLER AIR-CONDITIONING SYSTEM. Job Name: System Reference: Outdoor Unit: PUY-A36NKA7

SUBMITTAL DATA: PVA-A36AA7 & PUZ-HA36NHA5 36,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM. Job Name: System Reference:

SUBMITTAL DATA: MSY-GL12NA & MUY-GL12NA 12,000 BTU/H WALL-MOUNTED AIR-CONDITIONING SYSTEM. System Reference:

SUBMITTAL DATA: MSY-GL24NA & MUY-GL24NA 24,000 BTU/H WALL-MOUNTED AIR-CONDITIONING SYSTEM. System Reference:

M-SERIES SUBMITTAL DATA: SEZ-KD15NA4** & SUZ-KA15NA. Job Name: Location: Date: Submitted to: For Reference Approval Construction

SUBMITTAL DATA: SLZ-KA09NA & SUZ-KA09NA 9,000 BTU/H CEILING-CASSETTE HEAT-PUMP SYSTEMS. Cooling 4. Heating

SUBMITTAL DATA: SLZ-KA09NA... 9,000 BTU/H CEILING-CASSETTE INDOOR UNIT FOR MXZ-B MULTI-ZONE HEAT-PUMP SYSTEMS

1. INDOOR UNITS... MSZ-FH-3 2. OUTDOOR UNITS... MSZ-FH-4 3. SYSTEM... MSZ-FH-5

SUBMITTAL DATA: MSZ-FH06NA & MUZ-FH06NA 6,000 BTU/H WALL-MOUNTED HEAT PUMP SYSTEM. Electrical Power Requirements. Indoor / Outdoor A 1 / 11

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8.

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C)

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

Ductless Split Systems Concealed Duct Heat Pumps

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

Ductless Split Systems Wall-mounted, Single Zone Heat Pump

P-Series Full-line Catalog. Commercial-grade Applications. Smart, Efficient INVERTER-driven Ductless and Ducted Comfort Systems.

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

Ductless Split Systems Ceiling Cassette Heat Pumps

P-Series Full-line Catalog. Commercial-grade Applications. Smart, Efficient INVERTER-driven Ductless and Ducted Comfort Systems.

Product Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56

M-SERIES PRODUCT CATALOG

Submitted to: For Reference Approval Construction

Residential and Light Commercial Ductless Systems Catalog

The Hyper-Heat Advantage

P-Series Full-line Catalog. Commercial-grade Applications. Smart, Efficient INVERTER-driven Ductless and Ducted Comfort Systems.

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

High Efficiency, Powerful Heating and Cooling HEAT PUMP PEH-7, 8, 10 AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS. Series

P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP

Ductless Split Systems Wall-mounted, Multizone Heat Pump

Samsung 360 Cassette, Single Zone, Split System

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH

INVERTER-driven. Split-ductless and ducted Comfort Systems M Series Full Line Catalog.

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP

A single answer for multiple zones.

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC

DESIGN & TECHNICAL MANUAL

Heating & Cooling Products

Ductless Split Systems. J Series. The Next Generation of Ductless Split Systems

PUHZ-SHW140YHA PUHZ-SHW230YKA

DESIGN & TECHNICAL MANUAL

Air Conditioning & Heating. Ductless Product Catalog

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

Product Data INDUSTRY LEADING FEATURES / BENEFITS

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS. Now Only One Unit Required for Initial Start-up

A single answer for multiple zones.

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

Ductless Split Systems. J Series. The Next Generation of Ductless Split Systems

SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Kühl J Series DUCTLESS ROOM AIR CONDITIONERS THE EXPERTS IN ROOM AIR CONDITIONING. Wall-mounted Ceiling Cassette The Insider Concealed Ducted

Cold Remedies. SamsungHVAC.com. Product Registration Required Conditions Apply

Project ID: 9217 Project name: Fuller Lake Arena Address: Fuller Lake, BC V0R 1K5 Project Type: Sports Complex / Civic Center

DAIKIN FBQ DUCTED SERIES HEATING & COOLING SYSTEMS. DC DUCT-CONCEALED Up to 17.5 SEER / Up to 10.6 HSPF Up to 13.0 EER

Market District Commons. Black Oak Engineering. Daikin Ductless Heat Pump Split Systems N/A N/A M001. Plans. Fujitsu ductless heat pump systems

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

Ceiling Cassettes PLH-3AKH1.UK PLH-3AKH.UK PLH-4AKHS1.UK PLH-4AKHS.UK PLH-5AKHS1.UK PLH-5AKHS.UK PLH-6AKHS1.UK PLH-6AKHS.UK

Digital Inverter 4 series 8 & 10HP

SUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

SUBMITTAL M4MHW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA TAG:

LV Series. SEER 15+ Concealed Built in Heat Pump

DUCTLESS FULL LINE CATALOG

FBQ. DC Duct Heat Pump or Cooling Only

Lennox Mini-Split Systems Year-Round Comfort and Performance

PMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100

P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP


SERVICE MANUAL MUZ-D30NA / - MUZ-D36NA / - MUY-D30NA / - MUY-D36NA / - OUTDOOR UNIT. No. OBH502. Models HFC. Revision E: REVISED EDITION-E R410A

Engineering Data Book

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

SERVICE MANUAL MUZ-D30NA MUZ-D30NA- U1 MUZ-D36NA MUZ-D36NA- U1 MUY-D30NA MUY-D36NA OUTDOOR UNIT. No. OBH502. Wireless type Models HFC R410A

ZONED COMFORT SOLUTIONS

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE

DUCTLESS SPLIT SYSTEMS

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

Carrier. Ductless Systems. Taking Comfort, And Your Business, Further. The Right Solution. Right Now.

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

1 TECHNICAL CHANGES. MUZ-A09NA MUZ-A09NA - 1 MUZ-A09NA - U1 MUZ-A09NA - U2 1. Refrigerant system diagram has been changed.

TECHNICAL DATA & SERVICE MANUAL

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL

Well rounded. 360 CASSETTE. A truly circular cassette. Enjoy even airflow from a beautifully sleek design that fits into any setting.

SUBMITTAL M4MLW1809A-SUB-1A. Specifications 18 SERIES. Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA TAG:

Redefining Comfort. Mr. Slim Splitductless

DESIGN & TECHNICAL MANUAL

Transcription:

P-SERIES SUBMITTAL DATA: PLA-A12EA7 & PUZ-A12NKA7(-BS) 12,000 BTU/H -CASSETTE HEAT PUMP SYSTEM Job Name: System Reference: Date: Indoor Unit: Outdoor Unit: PLA-A12EA7 PUZ-A12NKA7 PUZ-A12NKA7-BS INDOOR UNIT FEATURES Space-efficient ductless installation Equipped with 3D i-see SensorTM for enhanced comfort and energy efficiency Airflow settings for high and low ceiling applications Individual vane settings for direct/indirect airflow control or variable airflow patterns Knockouts for outside-air intake and branch-duct run Filter indicator signal Easy-to-clean, washable filter (optional high-efficiency filter available - requires multi-function casement) Built-in condensate lift mechanism Ideal for retail shops, classrooms, office spaces, conference centers, building lobbies, and more OUTDOOR UNIT FEATURES Variable speed INVERTER-driven compressor Suction accumulator pre-charged with refrigerant volume for piping length up to 100 ft (70 ft. for A12/18/24/30) 24-hour continuous operation (cooling mode) High pressure protection Fast restart due to bypass valve make it ideal for equipment cooling applications, such as data centers Superior energy and operational efficiency

SPECIFICATIONS: PLA-A12EA7 & PUZ-A12NKA7(-BS) Model number Indoor unit PLA-A12EA7 Outdoor unit PUZ-A12NKA7 PUZ-A12NKA7-BS Cooling*1 Maximum Capacity Btu/h 12,000 Rated Capacity Btu/h 12,000 Minimum Capacity Btu/h 5,800 Maximum Power Input W 730 Rated Power Input W 730 Moisture Removal Pints/h 1.2 Sensible Heat Factor 0.89 Power factor % 93.4 Heating at 47 F*2 Maximum Capacity Btu/h 20,000 Heating at 17 F *3 Rated Capacity Btu/h 14,000 Minimum Capacity Btu/h 5,500 Maximum Power Input W 1,500 Rated Power Input W 830 Power factor % 95.0 Maximum Capacity Btu/h 12,200 Rated Capacity Btu/h 10,100 Maximum Power Input W 1,200 Rated Power Input W 1,170 Efficiency SEER 27.0 EER *1 16.4 HSPF (IV) 12.8 COP at 47 F *2 4.94 COP at 17 F *3 2.53 ENERGY STAR Certified Electrical Voltage, Phase, Frequency 208 / 230V, 1-phase, 60 Hz Guaranteed Voltage Range V AC 187-253 Voltage: Indoor - Outdoor, S1-S2 V AC 208V / 230 Voltage: Indoor - Outdoor, S2-S3 V DC 24 Voltage: Indoor - Remote controller V DC 12 Recommended Fuse/Breaker Size A 15 Recommended Wire Size (Indoor - Outdoor) AWG 14 Indoor unit MCA A 1.00 Fan Motor Full Load Amperage A 0.36 Yes

SPECIFICATIONS: PLA-A12EA7 & PUZ-A12NKA7(-BS) Model number Indoor unit PLA-A12EA7 Indoor unit operating temperature range Outdoor unit PUZ-A12NKA7 PUZ-A12NKA7-BS Fan Motor Output W 50 Airflow Rate, Dry CFM 420-460-490-530 Airflow Rate, Wet CFM 380-420-450-490 External Static Pressure in.wg n/a Sound Pressure Level db(a) 27-28-29-30 Drain Pipe Size In. (mm) 1-1/4 (32) Condensate Lift Mechanism, Max. Distance In. (mm) 33-7/16 (860) Heat Exchanger Type Plate fin coil External Finish Color White Munsell 6.4Y 8.9/0.4 Unit Dimensions // Grille Dimensions W: In. (mm) 33-1/16 (840) // 37-13/32 (950) D: In. (mm) 33-1/16 (840) // 37-13/32 (950) H: In. (mm) 10-5/32 (258) // 1-9/16 (40) Package Dimensions // Grille Dimensions W: In. (mm) 35-9/16 // 39-6/16 D: In. (mm) 34-5/16 // 38-3/16 H: In. (mm) 15 // 4-12/16 Unit Weight // Grille Weight Lbs. (kg) 46 (21) // 11 (5) Package Weight Lbs. (kg) 68 (31) Cooling Intake Air Temp (Maximum / Minimum) Heating Intake Air Temp (Maximum / Minimum) F 90 DB, 73 WB / 66 DB, 59 WB F 82 DB / 50 DB Outdoor unit MCA A 11 MOCP A 28 Fan Motor Full Load Amperage A 0.50 Fan Motor Output W 46 Airflow Rate CFM 1,590 Refrigerant Control Defrost Method Heat Exchanger Type Electronic Expansion Valve Reverse Cycle Cross fin Sound Pressure Level, Cooling*1 db(a) 44 Sound Pressure Level, Heating*2 db(a) 46 Compressor Type Compressor Model Inverter-driven twin rotary SNB092FNCM Compressor Rated Load Amps A 7

SPECIFICATIONS: PLA-A12EA7 & PUZ-A12NKA7(-BS) Model number Indoor unit PLA-A12EA7 Outdoor unit operating temperature range Outdoor unit PUZ-A12NKA7 PUZ-A12NKA7-BS Compressor Locked Rotor Amps A 12 Compressor Oil Type // Charge oz. FV50S // 12 External Finish Color Ivory Munsell 3Y 7.8/1.1 Base pan heater Unit Dimensions W: In. (mm) 31-13/16 + 7/16 (809+62) n/a D: In. (mm) 11-3/16 (300) H: In. (mm) 24-13/16 (630) Package Dimensions W: In. (mm) 37-1/16 D: In. (mm) 16-3/16 H: In. (mm) 27-7/16 Unit Weight Lbs. (kg) 93 (42) Package Weight Lbs. (kg) 104 (47) Cooling Intake Air Temp (Maximum / Minimum) Heating Intake Air Temp (Maximum / Minimum) F 115 DB / 0* DB F 70 DB, 59 WB / 12 DB, 10 WB Thermal Lock-out / Re-start Temperatures** F 8 / 12 DB Refrigerant Type R410A Charge Lbs, oz 4 lbs, 7 oz Piping Gas Pipe Size O.D. (Flared) In.(mm) 1/2 (12.7) Liquid Pipe Size O.D. (Flared) In.(mm) 1/4 (6.35) Maximum Piping Length Ft. (m) 100 (30) Maximum Height Difference Ft. (m) 100 (30) Maximum Number of Bends 15 AHRI Rated Conditions (Rated data is determined at a fixed compressor speed) *1 Cooling (Indoor // Outdoor) F 80 F DB, 67 F WB // 95 F DB, 75 F WB *2 Heating at 47 F (Indoor // Outdoor) F 70 F DB, 60 F WB // 47 F DB, 43 F WB *3 Heating at 17 F (Indoor // Outdoor) F 70 F DB, 60 F WB // 17 F DB, 15 F WB Conditions *4 Heating at 5 F (Indoor // Outdoor) F 70 F DB, 60 F WB // -4 F DB, -5 F WB Notes *Wind baffles required to operate below 23 F DB in cooling mode. PUZ with wind baffle: 0 F - 115 F. **System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures

SPECIFICATIONS: PLA-A12EA7 & PUZ-A12NKA7(-BS) SEACOAST PROTECTION External Outer Panel: Phosphate coating + Acrylic-Enamel coating Fan Motor Support: Epoxy resin coating (at edge face) Separator Assembly; Valve Bed: Epoxy resin coating (at edge face) Blue Fin treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants. Notes:

ACCESSORIES: PLA-A12EA7 & PUZ-A12NKA7(-BS) PLA-A12EA7 High Efficiency (MERV 10) Filter Element (Requires PAC-SJ41TM-E Multi-Function Casement) PAC-SH59KF-E Grille with 3D i-see Sensor TM Air outlet shutter Plate Multi-functional Casement Flange for fresh-air Intake 3-Pole Disconnect Switch (30A/600V/UL) [fits 2" X 4" utility box] Drain Pan Level Sensor (Control for indoor unit shut off to prevent drain pan overflow) PLP-40EAEU PAC-SJ37SP-E PAC-SJ41TM-E PAC-SH65OF-E TAZ-MS303 DPLS2 Advanced Blue Diamond Mini-Condensation pump w/ Resevoir & Sensor (110V) X87-711 - 110 Advanced Blue Diamond Mini-Condensation pump w/ Resevoir & Sensor (208/230V) X87-721 - 208/230 Extension Cord for Blue Diamond Pump C13-103 MegaBlue Blue Diamond Condensate Pump (110-230V) X87-835 Remote Sensor (extensible) Connector for CN32 (remote on/off) Remote Operation Adapter (with wire terminals for remote on/off and operation status/ error) External fan / Heater control relay adapter Backlit, wall-mounted, wireless Wireless Remote Controller Wireless Receiver Portable Central Controller Outside Air Sensor Wireless adapter BACnet and Modbus Interface Wall-mounted, Wired Wired remote controller T-STAT Interface Wired remote controller Signal Receiver Simple remote controller Wireless Remote Controller Wire for Remote ON/OFF with CN32 connector Lockdown Bracket for wireless, hand-held, remote controllers *1 Unable to use with wireless remote controller PAC-SE41TS-E PAC-SE55RA-E PAC-SF40RM-E *1 CN24RELAY-KIT-CM3 MHK1 MRCH1 MFH1 MCCH1 MOS1 PAC-USWHS002-WF-1 PAC-UKPRC001-CN-1 PAC-YT53CRAU-J PAR-32MAA-J PAC-US444CN-1 PAR-32MAA PAR-SR3LA-E PAC-YT53CRAU PAR-FL32MA-E PAC-715AD RCMKP1CB

ACCESSORIES: PLA-A12EA7 & PUZ-A12NKA7(-BS) PUZ-A12NKA7(-BS) Air Outlet Guide PAC-SJ07SG-E Front Wind Baffle WB-PA4 Drain socket PAC-SJ08DS-E Centralized Drain Pan PAC-SG63DP-E M-NET Converter PAC-SJ19MA-E Control/Service Tool PAC-SK52ST Wall mounting bracket (powder-coated steel) QCWB2000M-1 Wall mounting bracket (316 Series Stainless Steel) QCWBSS M-NET control adapter for Building Management System PAC-SF83MA-E Outdoor Unit Mounting Pad 16" x 36" x 3" ULTRILITE1 Outdoor Unit 3-1/4 inch Mounting Base - Pair (Plastic) DSD-400N MiniSplit Mounting Stand-Single Fan models - 12" QSMS1201M MiniSplit Mounting Stand-Single Fan models - 18" QSMS1801M MiniSplit Mounting Stand-Single Fan models - 24" QSMS2401M 1/4 x 1/2 x 15' / 1/2" Lineset (Twin-Tube Insulation) MLS141212T-15 1/4 x 1/2 x 30' / 1/2" Lineset (Twin-Tube Insulation) MLS141212T-30 1/4 x 1/2 x 50' / 1/2" Lineset (Twin-Tube Insulation) MLS141212T-50 1/4 x 1/2 x 65' / 1/2" Lineset (Twin-Tube Insulation) MLS141212T-65 1/4 x 1/2 x 100' / 1/2" Lineset (Twin-Tube Insulation) MLS141212T-100

+5 0 0 0 F E DIMENSIONS: PLA-A12EA7 & PUZ-A12NKA7 (-BS) PLA-A12EA7 NOTE1.CHOOSE THE GRILLE AMONG THE DEDICATED GRILLES. 2.REINFORCE THE SUSPENSION BOLT FOR EARTHQUAKE-RESISTANCE AS NEEDED. 3.FOR THE SUSPENSION BOLT, USE M10 OR W3/8. (PROCURED AT THE LOCAL SITE.) 4.FOR DRAIN PIPE, USE VP-25(O.D. n1-1/4''( { 32) PVC TUBE). DRAIN PUMP INCLUSION. RAISE IS MAX 33-7/16''(850mm) FROM THE. 5.ELECTRICAL BOX MAY BE REMOVED FOR THE SERVICE PURPOSE. MAKE SURE TO SLACK THE ELECTRICAL WIRE LITTLE BIT FOR CONTROL/POWER WIRES CONNECTION. 6.THE HEIGHT OF THE INDOOR UNIT IS ABLE TO BE ADJUSTED WITH THE GRILLE ATTACHED. 7.REQUIRES "E" OR MORE SPACE BETWEEN TRANSOM AND FOR THE INSTALLATION. 8.WHEN INSTALLING THE BRANCH DUCTS, BE SURE TO INSULATE ADEQUATELY. OTHERWISE CONDENSATION AND DRIPPING MAY OCCUR. (IT BECOMES THE CAUSE OF DROPLET OR DROPLET DRIPPING.) 9.AS FOR NECESSARY INSTALLATION/SERVICE SPACE, PLEASE REFER TO THE RIGHT AT FIGURE. 10.FOR THE INSTALLATION OF THE OPTIONAL HIGH EFFICIENCY FILTER OR MULTI-FUNCTIONAL CASEMENT,REFER TO SPECIAL DRAWING. 37-3/8(950) DRAIN HOLE 1-7/16(37) 20-7/8(530) (AIR OUTLET HOLE) (89) 3-1/2 (37) 1-7/16 (89) 3-1/2 COMPANY NAME OPTIONAL PART:SIGNAL RECEIVER 20(508) (AIR INTAKE HOLE) (AIR OUTLET HOLE) 20-7/8(530) 37-3/8(950) AUTO VANE CORNER POCKET VANE MOTOR 20(508) (AIR INTAKE HOLE) AIR INTAKE GRILLE GRILLE GRILLE WALL I-SEE SENSOR CORNER PANEL SOME GRILLES DO NOT HAVE THIS PART. *CAN INSTALL TO THE CORNER EXCEPT DRAIN PIPE CORNER (NEED TO FUNCTION SETTING BY REMOTE CONTROLLER) INDOOR UNIT OBSTACLE (1000mm) 39-3/8 OR MORE 59-1/16(1500mm) OR MORE REMOTE CONTROLLER WIRE ENTRY 70 17-11/16(450) FLOOR BRANCH DUCT HOLE 33-1/16(840) {5-7/8({150) CUTOUT HOLE {6-7/8({175) BURRING HOLE PITCH SELF-TAP 4 SCREWS:4 PLACES INDOOR UNIT 118-1/8(3000mm) OR MORE BETWEEN INDOOR UNIT (20-45) 13/16 TO 1-3/4 REMOTE CONTROLLER WIRE ENTRY 1/4 OR MORE (7mm) 70-7/8(1800mm) OR MORE FROM FLOOR (145) 5-11/16 REMOTE CONTROLLER TERMINAL BLOCK INDOOR UNIT/ OUTDOOR UNIT CONNECTING TERMINAL BLOCK (133) 5-1/4 3-1/8(79.5) BETWEEN THE TOP OF UNIT AND SLAB (145) 5-11/16 (193) 7-5/8 (222) 8-3/4 D C SPACE IN THE HEIGHT BRANCH DUCT HOLE ( HOLE) 33-7/8 TO 35-13/16(860-910) 31-5/16 (795) (SUSPENSION BOLT PITCH) BRANCH DUCT HOLE 33-1/16(840) (145) 5-11/16 (20-45) 13/16 TO 1-3/4 1/4(6) FRESH AIR INTAKE HOLE 5-11/16(145) (SUSPENSION BOLT PITCH) (660 +40 ) (20) 13/16 +1-9/16 0 26 (20) 13/16 (20-45) 13/16 TO 1-3/4 33-7/8 TO 35-13/16(860-910) (20-45) 13/16 TO 1-3/4 ( HOLE) BRANCH DUCT HOLE Unit: inch (mm) 15-3/8(390) (100) 3-15/16 (100) 3-15/16 (90) 3-9/16 (90) 3-9/16 (100) 3-15/16 DETAILS OF FRESH AIR INTAKE HOLE {3-15/16({100) CUTOUT HOLE 70 (130) 5-1/8 120 (167) 6-9/16 (155) 6-1/8 120 (350) 13-3/4 {4-15/16({125) BURRING HOLE PITCH SELF-TAP 4 SCREWS:3 PLACES GRILLE 6-1/4 (158) {6-7/8({175) BURRING HOLE PITCH SELF-TAP 4 SCREWS:4 PLACES {5-7/8({150) CUTOUT HOLE SELF-TAP 4 SCREWS:14 PLACES 13-3/4 3-15/16(350 100) CUTOUT HOLE 6 OUTLINES AND DIMENSIONS PLA-A.EA7*:12/18/24/30/36/42 SUSPENSION BOLT M10 OR W3/8 2 1 (60) 2-3/8 MAIN UNIT 24-3/4(628) DRAIN PIPE VP-25 CONNECTION (CONNECTED THE ATTACED DRAIN SOCKET) MODELS REFRIGERANT PIPEΦ6.35 FLARED CONNECTION 1/4F REFRIGERANT PIPEΦ9.52 FLARED CONNECTION 3/8F REFRIGERANT PIPE{12.7 FLARED CONNECTION 1/2F REFRIGERANT PIPE{15.88 FLARED CONNECTION 5/8F A B C D 9-1/2 10-3/16 (241) (258) 3(76) 3(76.5) 11-1/16 11-3/4 3-1/8 (281) (298) (79.5) E 10-7/16(265) OR MORE 12(305) OR MORE F 137-13/16(3500) OR LESS 177-3/16(4500) OR LESS DETAILS OF SIGNAL RECEVER RECEIVER OPERATION LAMP EMERGENCY OPERATION SWITCH <COOLING>AND EMERGENCY UP/DOWN SWITCH<UP> EMERGENCY OPERATION SWITCH <HEATING>AND EMERGENCY UP/DOWN SWITCH<DOWN> DEFROST/STAND BY LAMP (170) 6-11/16 (140) (50-70) 5-1/2 1-15/16 TO 2-3/4 2-5/16 (58) THE BOTTOM OF I-SEE SENSOR SUSPENSION BOLT LOWER EDGE INDOOR UNIT/OUTDOOR UNIT CONNECTING WIRE, POWER SUPPLY WIRE ENTRY GRILLE 4-1/8 (105) (190) 7-1/2 (17 ) 11/16 +3/16 A 1-9/16 (40) B

DIMENSIONS: PLA-A12EA7 & PUZ-A12NKA7 (-BS) 6 OUTLINES AND DIMENSIONS PUZ-A12NKA7(-BS) PUZ-A12NKA7 PUZ-A18NKA7 PUY-A12NKA7 PUY-A18NKA7 PUZ-A12NKA7-BS PUZ-A18NKA7-BS PUY-A12NKA7-BS PUY-A18NKA7-BS Unit: mm<in> 48<1-29/32> 404.5<15-15/16> Air intake Installation bolt pitch 500<19-11/16> drain hole ø 42 2-U Shaped notched holes (Foundation Bolt M10<W 3/8>) Air intake 300<11-13/16> 330<13> 360<14-3/16> 630 <24-13/16> Handle for moving 320<12-5/8> 22.3 <29/32> 8.5<11/32> 154.5 <6-3/32> Air discharge 310 <12-7/32> 40 <1-19/32> 32.5<1-9/32> 2-10 21 oval hole (Foundation Bolt M10 <W 3/8>) 22 <7/8> 23.2<15/16> Terminal connection Left... Power supply wiring Right... Indoor/Outdoor wiring 2- ø 22.2<7/8> 1/2 conduit hole 809 <31-7/8> 62 <2-15/32> 492<19-3/8> Earth terminal Service panel 164.5<6-1/2> 99.5<3-15/16> Service port 43 Service panel for charge plug Connection for liquid pipe FLARE ø 6.35 (1/4F) 35 Connection for gas pipe FLARE ø 12.7 (1/2F) 185.5 <7-5/16> Free space around the outdoor unit (basic example) Basically open 100mm<3-15/16> or more as long as no obstacle is placed on the rear and right-and-left sides of the unit FOUNDATION BOLTS Please secure the unit firmly with 4 foundation (M10<W3/8>) bolts. (Bolts, washers and nut must be purchased locally). <Foundation bolt height> Min.100mm <3-15/16> Min.350mm <13-25/32> Max. 18 mm<23/32> FOUNDATION Min.500mm <19-11/16> Min.100mm <3-15/16> PIPING-WIRING DIRECTION Piping and wiring connection can be made from the rear direction only. 2 sides should be open in the right, left and rear side. OCH636 14 1340 Satellite Boulevard. Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com FORM# PLA-A12EA7 / PUZ-A12NKA7(-BS) - 201702