SUBMITTAL DATA: PLA-A24EA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H CEILING-CASSETTE HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUY-A24NHA7

Similar documents
SUBMITTAL DATA: PLA-A36EA7 & PUZ-A36NKA7(-BS) 36,000 BTU/H CEILING-CASSETTE HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A36NKA7

SUBMITTAL DATA: PLA-A12EA7 & PUZ-A12NKA7(-BS) 12,000 BTU/H CEILING-CASSETTE HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A12NKA7

SUBMITTAL DATA: PCA-A24KA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H CEILING-SUSPENDED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A24NHA7

SUBMITTAL DATA: PEAD-A30AA7 & PUZ-A30NHA7(-BS) 30,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A30NHA7

SUBMITTAL DATA: PEAD-A24AA7 & PUY-A24NHA7(-BS) 24,000 BTU/H HORIZONTAL-DUCTED AIR-CONDITIONING SYSTEM. Job Name: System Reference:

SUBMITTAL DATA: PEAD-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A42NKA7

SUBMITTAL DATA: PEAD-A12AA7 & PUZ-A12NKA7(-BS) 12,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A12NKA7

SUBMITTAL DATA: PVA-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A42NKA7

SUBMITTAL DATA: PVA-A36AA7 & PUY-A36NKA7(-BS) 36,000 BTU/H AIR HANDLER AIR-CONDITIONING SYSTEM. Job Name: System Reference: Outdoor Unit: PUY-A36NKA7

SUBMITTAL DATA: PVA-A36AA7 & PUZ-HA36NHA5 36,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM. Job Name: System Reference:

SUBMITTAL DATA: MSY-GL24NA & MUY-GL24NA 24,000 BTU/H WALL-MOUNTED AIR-CONDITIONING SYSTEM. System Reference:

SUBMITTAL DATA: MSY-GL12NA & MUY-GL12NA 12,000 BTU/H WALL-MOUNTED AIR-CONDITIONING SYSTEM. System Reference:

M-SERIES SUBMITTAL DATA: SEZ-KD15NA4** & SUZ-KA15NA. Job Name: Location: Date: Submitted to: For Reference Approval Construction

SUBMITTAL DATA: SLZ-KA09NA & SUZ-KA09NA 9,000 BTU/H CEILING-CASSETTE HEAT-PUMP SYSTEMS. Cooling 4. Heating

SUBMITTAL DATA: SLZ-KA09NA... 9,000 BTU/H CEILING-CASSETTE INDOOR UNIT FOR MXZ-B MULTI-ZONE HEAT-PUMP SYSTEMS

1. INDOOR UNITS... MSZ-FH-3 2. OUTDOOR UNITS... MSZ-FH-4 3. SYSTEM... MSZ-FH-5

SUBMITTAL DATA: MSZ-FH06NA & MUZ-FH06NA 6,000 BTU/H WALL-MOUNTED HEAT PUMP SYSTEM. Electrical Power Requirements. Indoor / Outdoor A 1 / 11

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8.

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C)

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

P-Series Full-line Catalog. Commercial-grade Applications. Smart, Efficient INVERTER-driven Ductless and Ducted Comfort Systems.

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

P-Series Full-line Catalog. Commercial-grade Applications. Smart, Efficient INVERTER-driven Ductless and Ducted Comfort Systems.

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

Ductless Split Systems Concealed Duct Heat Pumps

M-SERIES PRODUCT CATALOG

Ductless Split Systems Wall-mounted, Single Zone Heat Pump

Ductless Split Systems Ceiling Cassette Heat Pumps

Submitted to: For Reference Approval Construction

Product Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56

P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP

P-Series Full-line Catalog. Commercial-grade Applications. Smart, Efficient INVERTER-driven Ductless and Ducted Comfort Systems.

The Hyper-Heat Advantage

Residential and Light Commercial Ductless Systems Catalog

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

Ductless Split Systems Wall-mounted, Multizone Heat Pump

High Efficiency, Powerful Heating and Cooling HEAT PUMP PEH-7, 8, 10 AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS. Series

PUHZ-SHW140YHA PUHZ-SHW230YKA

Ductless Split Systems. J Series. The Next Generation of Ductless Split Systems

INVERTER-driven. Split-ductless and ducted Comfort Systems M Series Full Line Catalog.

Samsung 360 Cassette, Single Zone, Split System

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

Ductless Split Systems. J Series. The Next Generation of Ductless Split Systems

Product Data INDUSTRY LEADING FEATURES / BENEFITS

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP

A single answer for multiple zones.

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC

P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP

DESIGN & TECHNICAL MANUAL

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

Kühl J Series DUCTLESS ROOM AIR CONDITIONERS THE EXPERTS IN ROOM AIR CONDITIONING. Wall-mounted Ceiling Cassette The Insider Concealed Ducted

SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

DESIGN & TECHNICAL MANUAL

Air Conditioning & Heating. Ductless Product Catalog

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS. Now Only One Unit Required for Initial Start-up

A single answer for multiple zones.

Lennox Mini-Split Systems Year-Round Comfort and Performance

Cold Remedies. SamsungHVAC.com. Product Registration Required Conditions Apply

Heating & Cooling Products

SUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

SUBMITTAL M4MHW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA TAG:

Product Data INDUSTRY LEADING FEATURES / BENEFITS

DUCTLESS FULL LINE CATALOG

Project ID: 9217 Project name: Fuller Lake Arena Address: Fuller Lake, BC V0R 1K5 Project Type: Sports Complex / Civic Center

DAIKIN FBQ DUCTED SERIES HEATING & COOLING SYSTEMS. DC DUCT-CONCEALED Up to 17.5 SEER / Up to 10.6 HSPF Up to 13.0 EER

Redefining Comfort. Mr. Slim Splitductless

Market District Commons. Black Oak Engineering. Daikin Ductless Heat Pump Split Systems N/A N/A M001. Plans. Fujitsu ductless heat pump systems

BENEFITS. Daikin North America LLC, 5151 San Felipe, Suite 500, Houston, TX, 77056

ZONED COMFORT SOLUTIONS

LV Series. SEER 15+ Concealed Built in Heat Pump

FBQ. DC Duct Heat Pump or Cooling Only

ELECTRICAL QUANTITY WEIGHT (LB)

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

Ceiling Cassettes PLH-3AKH1.UK PLH-3AKH.UK PLH-4AKHS1.UK PLH-4AKHS.UK PLH-5AKHS1.UK PLH-5AKHS.UK PLH-6AKHS1.UK PLH-6AKHS.UK

Lennox 8 Series Single Zone - R-410A

Submittal Sheet AIR-CON MULTI-SPLIT II. High-Wall Cassette Duct Floor and Ceiling AMTCM4H4R18

Carrier. Ductless Systems. Taking Comfort, And Your Business, Further. The Right Solution. Right Now.

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

PMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100

SUBMITTAL M4MLW1809A-SUB-1A. Specifications 18 SERIES. Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA TAG:

DESIGN & TECHNICAL MANUAL


Engineering Data Book

Highly Efficient,Powerful Heating and Cooling.

SERVICE MANUAL MUZ-D30NA / - MUZ-D36NA / - MUY-D30NA / - MUY-D36NA / - OUTDOOR UNIT. No. OBH502. Models HFC. Revision E: REVISED EDITION-E R410A

SERVICE MANUAL MUZ-D30NA MUZ-D30NA- U1 MUZ-D36NA MUZ-D36NA- U1 MUY-D30NA MUY-D36NA OUTDOOR UNIT. No. OBH502. Wireless type Models HFC R410A

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE

Digital Inverter 4 series 8 & 10HP

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

2016 RESIDENTIAL AND LIGHT COMMERCIAL DUCTLESS

Transcription:

P-SERIES SUBMITTAL DATA: PLA-A24EA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H -CASSETTE HEAT PUMP SYSTEM Job Name: System Reference: Date: Indoor Unit: Outdoor Unit: PLA-A24EA7 PUY-A24NHA7 PUY-A24NHA7-BS INDOOR UNIT FEATURES Space-efficient ductless installation Equipped with 3D i-see SensorTM for enhanced comfort and energy efficiency Airflow settings for high and low ceiling applications Individual vane settings for direct/indirect airflow control or variable airflow patterns Knockouts for outside-air intake and branch-duct run Filter indicator signal Easy-to-clean, washable filter (optional high-efficiency filter available - requires multi-function casement) Built-in condensate lift mechanism Ideal for retail shops, classrooms, office spaces, conference centers, building lobbies, and more OUTDOOR UNIT FEATURES Variable speed INVERTER-driven compressor Suction accumulator pre-charged with refrigerant volume for piping length up to 100 ft (70 ft. for A12/18/24/30) Low ambient cooling down to -20ºF providing 100% capacity (only for PUY models with wind baffles installed) 24-hour continuous operation (cooling mode) High pressure protection Fast restart due to bypass valve make it ideal for equipment cooling applications, such as data centers Superior energy and operational efficiency

SPECIFICATIONS: PLA-A24EA7 & PUZ-A24NHA7(-BS) Model number Indoor unit PLA-A24EA7 Outdoor unit PUZ-A24NHA7 PUZ-A24NHA7-BS Cooling*1 Maximum Capacity Btu/h 24,000 Rated Capacity Btu/h 24,000 Minimum Capacity Btu/h 10,000 Maximum Power Input W 1,670 Rated Power Input W 1,670 Moisture Removal Pints/h 3.0 Sensible Heat Factor 0.86 Power factor % 94.3 Heating at 47 F*2 Maximum Capacity Btu/h 29,000 Heating at 17 F *3 Rated Capacity Btu/h 26,000 Minimum Capacity Btu/h 9,000 Maximum Power Input W 2,070 Rated Power Input W 1,750 Power factor % 95.1 Maximum Capacity Btu/h 17,400 Rated Capacity Btu/h 14,900 Maximum Power Input W 1,670 Rated Power Input W 1,600 Efficiency SEER 24.2 EER *1 14.3 HSPF (IV) 11.2 COP at 47 F *2 4.35 COP at 17 F *3 2.72 ENERGY STAR Certified Electrical Voltage, Phase, Frequency 208 / 230V, 1-phase, 60 Hz Guaranteed Voltage Range V AC 187-253 Voltage: Indoor - Outdoor, S1-S2 V AC 208V / 230 Voltage: Indoor - Outdoor, S2-S3 V DC 24 Voltage: Indoor - Remote controller V DC 12 Recommended Fuse/Breaker Size A 25 Recommended Wire Size (Indoor - Outdoor) AWG 14 Indoor unit MCA A 1.00 Fan Motor Full Load Amperage A 0.60 Yes

SPECIFICATIONS: PLA-A24EA7 & PUZ-A24NHA7(-BS) Model number Indoor unit PLA-A24EA7 Indoor unit operating temperature range Outdoor unit PUZ-A24NHA7 PUZ-A24NHA7-BS Fan Motor Output W 120 Airflow Rate, Dry CFM 530-640-710-810 Airflow Rate, Wet CFM 490-600-670-770 External Static Pressure in.wg n/a Sound Pressure Level db(a) 28-30-33-36 Drain Pipe Size In. (mm) 1-1/4 (32) Condensate Lift Mechanism, Max. Distance In. (mm) 33-7/16 (860) Heat Exchanger Type Plate fin coil External Finish Color White Munsell 6.4Y 8.9/0.4 Unit Dimensions // Grille Dimensions W: In. (mm) 33-1/16 (840) // 37-13/32 (950) D: In. (mm) 33-1/16 (840) // 37-13/32 (950) H: In. (mm) 11-3/4 (298) // 1-9/16 (40) Package Dimensions // Grille Dimensions W: In. (mm) 35-9/16 // 39-6/16 D: In. (mm) 34-5/16 // 38-3/16 H: In. (mm) 16-9/16 // 4-12/16 Unit Weight // Grille Weight Lbs. (kg) 56 (25) // 11 (5) Package Weight Lbs. (kg) 68 (31) Cooling Intake Air Temp (Maximum / Minimum) Heating Intake Air Temp (Maximum / Minimum) F 90 DB, 73 WB / 66 DB, 59 WB F 82 DB / 50 DB Outdoor unit MCA A 19 MOCP A 26 Fan Motor Full Load Amperage A 0.40 Fan Motor Output W 86 Airflow Rate CFM 1,940 Refrigerant Control Defrost Method Heat Exchanger Type Electronic Expansion Valve Reverse Cycle Cross fin Sound Pressure Level, Cooling*1 db(a) 47 Sound Pressure Level, Heating*2 db(a) 48 Compressor Type Compressor Model Inverter-driven twin rotary SNB172FWHM1 Compressor Rated Load Amps A 7

SPECIFICATIONS: PLA-A24EA7 & PUZ-A24NHA7(-BS) Model number Indoor unit PLA-A24EA7 Outdoor unit operating temperature range Outdoor unit PUZ-A24NHA7 PUZ-A24NHA7-BS Compressor Locked Rotor Amps A 11 Compressor Oil Type // Charge oz. FV50S // 23 External Finish Color Ivory Munsell 3Y 7.8/1.1 Base pan heater Unit Dimensions W: In. (mm) 37-13/32 (950) n/a D: In. (mm) 13 + 1-3/16 (330 + 30) H: In. (mm) 37-1/8 (943) Package Dimensions W: In. (mm) 40-15/16 D: In. (mm) 17-11/16 H: In. (mm) 40-11/16 Unit Weight Lbs. (kg) 153 (69) Package Weight Lbs. (kg) 112 (51) Cooling Intake Air Temp (Maximum / Minimum) Heating Intake Air Temp (Maximum / Minimum) F 115 DB / 0* DB F 70 DB, 59 WB / -4 DB, -4 WB Thermal Lock-out / Re-start Temperatures** F -8 / -4 DB Refrigerant Type R410A Charge Lbs, oz 7 lbs, 11 oz Piping Gas Pipe Size O.D. (Flared) In.(mm) 5/8 (15.88) Liquid Pipe Size O.D. (Flared) In.(mm) 3/8 (9.52) Maximum Piping Length Ft. (m) 165 (50) Maximum Height Difference Ft. (m) 100 (30) Maximum Number of Bends 15 AHRI Rated Conditions (Rated data is determined at a fixed compressor speed) *1 Cooling (Indoor // Outdoor) F 80 F DB, 67 F WB // 95 F DB, 75 F WB *2 Heating at 47 F (Indoor // Outdoor) F 70 F DB, 60 F WB // 47 F DB, 43 F WB *3 Heating at 17 F (Indoor // Outdoor) F 70 F DB, 60 F WB // 17 F DB, 15 F WB Conditions *4 Heating at 5 F (Indoor // Outdoor) F 70 F DB, 60 F WB // -4 F DB, -5 F WB Notes *Wind baffles required to operate below 23 F DB in cooling mode. PUZ with wind baffle: 0 F - 115 F. **System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures

SPECIFICATIONS: PLA-A24EA7 & PUZ-A24NHA7(-BS) SEACOAST PROTECTION External Outer Panel: Phosphate coating + Acrylic-Enamel coating Fan Motor Support: Epoxy resin coating (at edge face) Separator Assembly; Valve Bed: Epoxy resin coating (at edge face) Blue Fin treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants. Notes:

ACCESSORIES: PLA-A24EA7 & PUY-A24NHA7(-BS) PLA-A24EA7 High Efficiency (MERV 10) Filter Element (Requires PAC-SJ41TM-E Multi-Function Casement) PAC-SH59KF-E Grille with 3D i-see Sensor TM Air outlet shutter Plate Multi-functional Casement Flange for fresh-air Intake 3-Pole Disconnect Switch (30A/600V/UL) [fits 2" X 4" utility box] Drain Pan Level Sensor (Control for indoor unit shut off to prevent drain pan overflow) PLP-40EAEU PAC-SJ37SP-E PAC-SJ41TM-E PAC-SH65OF-E TAZ-MS303 DPLS2 Advanced Blue Diamond Mini-Condensation pump w/ Resevoir & Sensor (110V) X87-711 - 110 Advanced Blue Diamond Mini-Condensation pump w/ Resevoir & Sensor (208/230V) X87-721 - 208/230 Extension Cord for Blue Diamond Pump C13-103 MegaBlue Blue Diamond Condensate Pump (110-230V) X87-835 Remote Sensor (extensible) Connector for CN32 (remote on/off) Remote Operation Adapter (with wire terminals for remote on/off and operation status/ error) External fan / Heater control relay adapter Backlit, wall-mounted, wireless Wireless Remote Controller Wireless Receiver Portable Central Controller Outside Air Sensor Wireless adapter BACnet and Modbus Interface Wall-mounted, Wired Wired remote controller T-STAT Interface Wired remote controller Signal Receiver Simple remote controller Wireless Remote Controller Wire for Remote ON/OFF with CN32 connector Lockdown Bracket for wireless, hand-held, remote controllers *1 Unable to use with wireless remote controller PAC-SE41TS-E PAC-SE55RA-E PAC-SF40RM-E *1 CN24RELAY-KIT-CM3 MHK1 MRCH1 MFH1 MCCH1 MOS1 PAC-USWHS002-WF-1 PAC-UKPRC001-CN-1 PAC-YT53CRAU-J PAR-32MAA-J PAC-US444CN-1 PAR-32MAA PAR-SR3LA-E PAC-YT53CRAU PAR-FL32MA-E PAC-715AD RCMKP1CB

ACCESSORIES: PLA-A24EA7 & PUY-A24NHA7(-BS) PUY-A24NHA7(-BS) Twinning Distribution Pipe (50:50) MSDD-50TR-E Front Wind Baffle WB-PA5 Drain socket PAC-SG61DS-E Centralized Drain Pan PAC-SG64DP-E M-NET Converter PAC-SF83MA-E Control/Service Tool PAC-SK52ST Wall mounting bracket (powder-coated steel) QCWB2000M-1 Wall mounting bracket (316 Series Stainless Steel) QCWBSS M-NET control adapter for Building Management System PAC-SF83MA-E Outdoor Unit Mounting Pad 24" x 42" x 3" ULTRILITE2 Outdoor Unit 3-1/4 inch Mounting Base - Pair (Plastic) DSD-400N MiniSplit Mounting Stand-Single Fan models - 12" QSMS1201M MiniSplit Mounting Stand-Single Fan models - 18" QSMS1801M MiniSplit Mounting Stand-Single Fan models - 24" QSMS2401M 3/8 x 5/8 x 10' / 1/2" Lineset (Twin-Tube Insulation) MPLS385812T-10 3/8 x 5/8 x 15' / 1/2" Lineset (Twin-Tube Insulation) MPLS385812T-15 3/8 x 5/8 x 30' / 1/2" Lineset (Twin-Tube Insulation) MPLS385812T-30 3/8 x 5/8 x 50' / 1/2" Lineset (Twin-Tube Insulation) MPLS385812T-50 3/8 x 5/8 x 65' / 1/2" Lineset (Twin-Tube Insulation) MPLS385812T-65 3/8 x 5/8 x 100' / 1/2" Lineset (Twin-Tube Insulation) MPLS385812T-100

+5 0 0 0 F E DIMENSIONS: PLA-A24EA7 & PUZ-A24NHA7 (-BS) PLA-A24EA7 NOTE1.CHOOSE THE GRILLE AMONG THE DEDICATED GRILLES. 2.REINFORCE THE SUSPENSION BOLT FOR EARTHQUAKE-RESISTANCE AS NEEDED. 3.FOR THE SUSPENSION BOLT, USE M10 OR W3/8. (PROCURED AT THE LOCAL SITE.) 4.FOR DRAIN PIPE, USE VP-25(O.D. n1-1/4''( { 32) PVC TUBE). DRAIN PUMP INCLUSION. RAISE IS MAX 33-7/16''(850mm) FROM THE. 5.ELECTRICAL BOX MAY BE REMOVED FOR THE SERVICE PURPOSE. MAKE SURE TO SLACK THE ELECTRICAL WIRE LITTLE BIT FOR CONTROL/POWER WIRES CONNECTION. 6.THE HEIGHT OF THE INDOOR UNIT IS ABLE TO BE ADJUSTED WITH THE GRILLE ATTACHED. 7.REQUIRES "E" OR MORE SPACE BETWEEN TRANSOM AND FOR THE INSTALLATION. 8.WHEN INSTALLING THE BRANCH DUCTS, BE SURE TO INSULATE ADEQUATELY. OTHERWISE CONDENSATION AND DRIPPING MAY OCCUR. (IT BECOMES THE CAUSE OF DROPLET OR DROPLET DRIPPING.) 9.AS FOR NECESSARY INSTALLATION/SERVICE SPACE, PLEASE REFER TO THE RIGHT AT FIGURE. 10.FOR THE INSTALLATION OF THE OPTIONAL HIGH EFFICIENCY FILTER OR MULTI-FUNCTIONAL CASEMENT,REFER TO SPECIAL DRAWING. 37-3/8(950) DRAIN HOLE 1-7/16(37) 20-7/8(530) (AIR OUTLET HOLE) (89) 3-1/2 (37) 1-7/16 (89) 3-1/2 COMPANY NAME OPTIONAL PART:SIGNAL RECEIVER 20(508) (AIR INTAKE HOLE) (AIR OUTLET HOLE) 20-7/8(530) 37-3/8(950) AUTO VANE CORNER POCKET VANE MOTOR 20(508) (AIR INTAKE HOLE) AIR INTAKE GRILLE GRILLE GRILLE WALL I-SEE SENSOR CORNER PANEL SOME GRILLES DO NOT HAVE THIS PART. *CAN INSTALL TO THE CORNER EXCEPT DRAIN PIPE CORNER (NEED TO FUNCTION SETTING BY REMOTE CONTROLLER) INDOOR UNIT OBSTACLE (1000mm) 39-3/8 OR MORE 59-1/16(1500mm) OR MORE REMOTE CONTROLLER WIRE ENTRY 70 17-11/16(450) FLOOR BRANCH DUCT HOLE 33-1/16(840) {5-7/8({150) CUTOUT HOLE {6-7/8({175) BURRING HOLE PITCH SELF-TAP 4 SCREWS:4 PLACES INDOOR UNIT 118-1/8(3000mm) OR MORE BETWEEN INDOOR UNIT (20-45) 13/16 TO 1-3/4 REMOTE CONTROLLER WIRE ENTRY 1/4 OR MORE (7mm) 70-7/8(1800mm) OR MORE FROM FLOOR (145) 5-11/16 REMOTE CONTROLLER TERMINAL BLOCK INDOOR UNIT/ OUTDOOR UNIT CONNECTING TERMINAL BLOCK (133) 5-1/4 3-1/8(79.5) BETWEEN THE TOP OF UNIT AND SLAB (145) 5-11/16 (193) 7-5/8 (222) 8-3/4 D C SPACE IN THE HEIGHT BRANCH DUCT HOLE ( HOLE) 33-7/8 TO 35-13/16(860-910) 31-5/16 (795) (SUSPENSION BOLT PITCH) BRANCH DUCT HOLE 33-1/16(840) (145) 5-11/16 (20-45) 13/16 TO 1-3/4 1/4(6) FRESH AIR INTAKE HOLE 5-11/16(145) (SUSPENSION BOLT PITCH) (660 +40 ) (20) 13/16 +1-9/16 0 26 (20) 13/16 (20-45) 13/16 TO 1-3/4 33-7/8 TO 35-13/16(860-910) (20-45) 13/16 TO 1-3/4 ( HOLE) BRANCH DUCT HOLE Unit: inch (mm) 15-3/8(390) (100) 3-15/16 (100) 3-15/16 (90) 3-9/16 (90) 3-9/16 (100) 3-15/16 DETAILS OF FRESH AIR INTAKE HOLE {3-15/16({100) CUTOUT HOLE 70 (130) 5-1/8 120 (167) 6-9/16 (155) 6-1/8 120 (350) 13-3/4 {4-15/16({125) BURRING HOLE PITCH SELF-TAP 4 SCREWS:3 PLACES GRILLE 6-1/4 (158) {6-7/8({175) BURRING HOLE PITCH SELF-TAP 4 SCREWS:4 PLACES {5-7/8({150) CUTOUT HOLE SELF-TAP 4 SCREWS:14 PLACES 13-3/4 3-15/16(350 100) CUTOUT HOLE 6 OUTLINES AND DIMENSIONS PLA-A.EA7*:12/18/24/30/36/42 SUSPENSION BOLT M10 OR W3/8 2 1 (60) 2-3/8 MAIN UNIT 24-3/4(628) DRAIN PIPE VP-25 CONNECTION (CONNECTED THE ATTACED DRAIN SOCKET) MODELS REFRIGERANT PIPEΦ6.35 FLARED CONNECTION 1/4F REFRIGERANT PIPEΦ9.52 FLARED CONNECTION 3/8F REFRIGERANT PIPE{12.7 FLARED CONNECTION 1/2F REFRIGERANT PIPE{15.88 FLARED CONNECTION 5/8F A B C D 9-1/2 10-3/16 (241) (258) 3(76) 3(76.5) 11-1/16 11-3/4 3-1/8 (281) (298) (79.5) E 10-7/16(265) OR MORE 12(305) OR MORE F 137-13/16(3500) OR LESS 177-3/16(4500) OR LESS DETAILS OF SIGNAL RECEVER RECEIVER OPERATION LAMP EMERGENCY OPERATION SWITCH <COOLING>AND EMERGENCY UP/DOWN SWITCH<UP> EMERGENCY OPERATION SWITCH <HEATING>AND EMERGENCY UP/DOWN SWITCH<DOWN> DEFROST/STAND BY LAMP (170) 6-11/16 (140) (50-70) 5-1/2 1-15/16 TO 2-3/4 2-5/16 (58) THE BOTTOM OF I-SEE SENSOR SUSPENSION BOLT LOWER EDGE INDOOR UNIT/OUTDOOR UNIT CONNECTING WIRE, POWER SUPPLY WIRE ENTRY GRILLE 4-1/8 (105) (190) 7-1/2 (17 ) 11/16 +3/16 A 1-9/16 (40) B

DIMENSIONS: PLA-A24EA7 & PUZ-A24NHA7 (-BS) 2-U Shaped notched holes (Foundfation Bolt M10<W3/8>) 175 <6-7/8> 19<3/4> 330 <13> Air Discharge 61<2-13/32> 40<19/32> 0 53<2-3/32> 70 <2-3/4> 57<2-1/4> 41 <1-5/8> 2-12 36 oval holes (Foundation Bolt M10<W3/8>) Min. Min.100mm <3-15/16> FOUNDATION 25 <31/32> 500 <19-11/16> Side Air Intake Max. 500 <19-11/16> Min. 175<6-7/8> Rear Air Intake Side Air Intake Handle for moving Terminal Connections Left... Power supply wiring Reight... Indoor/Outdoor wiring 950 <37-13/32> 322<12-11/16> Earth terminal Service panel 19<3/4> 5/8> 92 <3-5/8> 55 <2-3/16> Power supply wiring hole (2- ø27<1-1/16>knockout) Rear trunking hole -5/8> ø92 <3 Rear piping hole 1/2 Conduit attachment 2-ø22.2<7/8> 40<1-9/16> 74<2-19/32> 219 <8-5/8> 40<1-9/16> 71<2-13/16> Set the attachment to the When installing the conduit, inner side of each panel. 81<3-3/16> ø 92 <3-45<1-25/32> 73 <2-7/18> 63 <2-1/2> 55 <2-3/16> 40<1-9/16> 27<1-1/16> 63<2-1/2> 55<2-3/16> 75 <2-31/32> 23 <29/32> 65<2-9/16> 27 23 <29/32> <1-1/16> 92 <3-5/8> 73 <2-7/18> 63 <2-1/2> 92<3-5/8> Right piping hole 30 <1-3/16> 669<26-11/32> *1 447<17-5/8> 2 Front piping cover Rear piping cover Bottom piping hole 220 <8-21/32> 145 145 145 <5-23/32> <5-23/32> <5-23/32> Drain hole (5- ø33<1-5/16>) 92<3-5/18> 65 <2-9/16> PUY-A30NHA7 PUY-A30NHA7-BS Front piping hole ø 92 <3-5/8> 45<1-25/32> 27<1-1/16> 73 <2-7/8> Power supply wiring hole (2-ø27knockout) Front trunking hole 40<1-9/16> Power supply wiring hole (2- ø27knockout) Right trunking hole 31<1-7/32> Piping knockout Hole Details 1 71 <2-13/16> Air Intake PUY-A24NHA7 PUY-A24NHA7-BS 1... Refrigerant GAS pipe connection (FLARE) ø15.88(5/8f) 2... Refrigerant LIQUID pipe connection (FLARE) ø 9.52(3/8F) *1... Indication of STOP VALVE connection location. *1 431<16-31/32> Handle for moving 943 <37-1/8> 473 <18-5/8> 23 <29/32> Handle for moving Example of Notes 23 <29/32> 15 Handle for moving PUZ-A30NHA7 PUZ-A30NHA7-BS Service space 30 <1-3/16> Min. 100 <3-15/16> Min. 10 <13> Min. 10mm <3/8> 600<23-5/8> Installation Feet <Foundation bolt height> Min. 10mm <3/8> Min. 500mm <19-11/16> Piping and wiring connections can be made from 4 directions: FRONT,Right,Rear and Below. 370<14-9/16> 417 <1-1/32> Please secure the unit firmly with 4 foundation (M10<W3/8>) bolts. (Bolts and washers must be purchased locally.) Rear Air Intake 28<1-3/32> Dimensions of space needed for service access are shown in the below diagram. The diagram below shows a basic example. Explantion of particular details are given in the installation manuals etc. Unit: mm<in> 4 PIPING-WIRING DIRECTIONS 3 FOUNDATION BOLTS FREE OCH636 2 SERVICE SPACE 1 FREE SPACE (Around the unit) PUZ-A24NHA7 PUZ-A24NHA7-BS PUZ-A24NHA7(-BS) 1340 Satellite Boulevard. Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com FORM# PLA-A24EA7 / PUZ-A24NHA7(-BS) - 201702