Submittal. 5 Ton Convertible Air Handler TEM3A0C60S51SA TEM3A0C60-SUB-1C-EN. July 2014 TAG:

Similar documents
Submittal. 1 1/2 Ton Convertible Air Handler TEM3A0B18S21SA TEM3A0B18-SUB-1C-EN. July 2014 TAG:

Submittal. 2 Ton Convertible Air Handler TEM3A0B24S21SA TEM3A0B24-SUB-1C-EN. July 2014 TAG:

Variable Speed Convertible Air Handler 5 Ton

Variable Speed Convertible Air Handler 4 Ton

Variable Speed Convertible Air Handler 2 1/2 Ton

Product Data. Convertible Air Handlers 1 1/2 5Ton

Product Data. Convertible Air Handlers 1 1/2 5Ton

2 Ton Convertible Air Handler TAM7A0A24H21SD Standard Coil TAM7A0A24H21EA Black Epoxy Coil

Modular Multi-position Air Handler

Ameristar SUBMITTAL M4AH4E26B1A00AA. 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA TAG:

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers

Cooling/Heat Pump Convertible Air Handlers

Vertical Upflow Horizontal Left Air Handlers

Cooling/Heat Pump Convertible Air Handlers

Modular Multi-position Air Handlers

2TEH3F18A1000A 2TEH3F24A1000A 2TEH3F30A1000A 2TEH3F36A1000A 2TEH3F42A1000A 2TEH3F48A1000A 2TEH3F60A1000A 1½

Modular Multi-position Air Handlers

36,000-62,000 BTUH Nominal Capacity

Modular Multi-position Air Handlers

Cooling/Heat Pump Convertible Air Handlers

Modular Multi-position Air Handlers

Service Facts. Air Handler - Convertible Model: Series 2 Air Handlers ton GAT2A0B42S31SA GAT2A0C48S41SA GAT2A0C60S51SA WARNING: GAT2-SF-1B

Submittal. Split System Cooling 5.0 Ton 4A7A3060D1000P TAG:

Submittal. Split System Cooling 4A7A6024J-SUB-1B-EN. January A7A6024J1000B TAG:

Uncased Vertical Aluminum Upflow Cooling/HP Coils 2-5 Ton 4PXA. Heat Pump / Cooling Coils for R-410A PUB. NO

Service Facts. Split System Cooling 3.0 Ton 4A7A6036J-SF-1B-EN. January A7A6036J1000A

Aluminum Cased Heat Pump / Cooling Coils 2-5 Ton

Submittal. Single Packaged Heat Pump 15 SEER Convertible 4WCY5024A-SUB-1A-EN. March WCY5024A1000A TAG:

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 100,000 BTUH S9V2C100D4-SUB-1-EN. March 2016 S9V2C100D4PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U3-SUB-1-EN. February 2016 S9V2B080U3PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U4-SUB-1-EN. February 2016 S9V2B080U4PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 40,000 BTUH S9V2B040U3-SUB-1-EN. February 2016 S9V2B040U3PSAA TAG:

Service Facts WARNING: GAM5-SF-1D. Convertible Air Handlers ! WARNING

Hyperion Field Reference Data TAM8

Note: A/TZONE 950/850 communicating thermostats MUST be used for Variable Speed Outdoor units.

Product catalog. Hyperion TM split systems 60 Hz / R410A / 13 SEER SSA-PRC009-E4

Submittal. Single Packaged Convertible Gas/Electric 14 SEER 4YCC4024A-SUB-1F-EN. August YCC4024A1060A TAG:

Product Data. Single Packaged Heat Pump 14 SEER Convertible, 2 5 Ton B-EN. December 2014

Hyperion TM Split Systems

7/8 NO NO NO PROPELLER DIRECT / /230/1/ SPINE FIN /8 8 LBS., 0 OZ. YES 7/8 3/8

208/230/1/ CLIMATUFF /230/1/ YES NO NO PROPELLER 23-1 DIRECT / /230/1/ SPINE FIN

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

Product Data. Split System Cooling A. November 2013

Product Data. Split System Heat Pump D-EN. February 2016

4TTB3060D1000B 208/230/1/60 35 SCROLL /230/1/ /8

4TTB3030D1000B 208/230/1/60 4TTB3036D1000B 208/230/1/ RECIP /230/1/ RECIP YES YES

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6024-SF-1B. Split System Cooling 4TTR6024A1000B CAUTION CAUTION WARNING

Product Data. Split System Heat Pump A-EN. March 2016

Aluminum Cased and Uncased Heat Pump / Cooling Coils 1 1/2-5 Ton 2/4TXA, 2/4TXC PUB. NO Heat Pump /Cooling Coils for R-22 and R-410A

4TTR6036B1000A 208/230/1/ CLIMATUFF - SCROLL 3/4 3/4 3/4 3/4 3/4 208/230/1/ NO YES NO PROPELLER DIRECT

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080D3PSBA TAG:

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 60,000 BTUH S9V2B060D3PSBA TAG:

Product Data. Split System Heat Pump B-EN. February A6H6024H1000A

Split System Cooling Product & Performance Data

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 100,000 BTUH S9V2C100U4PSBA TAG:

3-11/ /8 4-5/16 6-5/8 5-7/8 1-9/16. Condensate drain connection 3/4 NPTI (Trap required) Electrical service access compartment panel

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6048-SF-1A. Split System Cooling 4TTR6048A1000A CAUTION CAUTION WARNING

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTB6-SF-3. Split System Cooling 4TTB6048A1000A, 4TTB6049A1000A CAUTION

SPECIFICATIONS 4YCC3060A-SPEC-1A SINGLE PACKAGED GAS HEATING ELECTRIC COOLING 4YCC3060A1096/120B TAG:

4YCC3048A3096A /3/ /

SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

4YCC3036A1075B /1/ / YCC3036A1064B /1/ /

TECHNICAL SPECIFICATIONS B6VMMX

SUBMITTAL M4MHW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA TAG:

Bosch BVA Series Air Handler


SUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

208/230/1/60 5/8 5/8 5/8 5/8 5/8 20 CLIMATUFF /230/1/

Product Data /4WCC3018A through 2/4WCC3060A Single Package Convertible Heat Pump 13 SEER 1½ - 5 Ton R-22/R-410A

Multi-position Air Handler

2YCC3060A1120A /1/ / YCC3060A1096A /1/ /

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

Service Facts. Split System Heat Pump 4A6H5019H-SF-1C-EN. August A6H5019H1000A

Unit Features & Benefits RQPM/RQRM Series

PRODUCT SPECIFICATIONS 2YCC3036A1096A /1/ /

PRODUCT SPECIFICATIONS 2YCC3048A1120A /1/ /

4A6H5049E1000B 208/230/1/ /8 7/8 7/8 7/8 DURATION 208/230/1/ /230/1/ SPINE FIN 13 LBS., 10 OZ. YES

4A6H5042G1000A 208/230/1/ DURATION - SCROLL 3/4 208/230/1/ NO (Use BAYKSKT263) YES YES PROPELLER DIRECT

Upflow/Downflow Horizontal Right or Left Gas-Fired Furnace

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE

SUBMITTAL M4MLW1809A-SUB-1A. Specifications 18 SERIES. Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA TAG:

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

ASUF Series. Multi-Position. Air Handler 1½ to 5 Tons

ARPT Series. Multi-Position. 1½ to 5 Tons. Internal TXV, Multi-Speed PSC Motor

AIR HANDLERS AIR HANDLERS

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

Upflow/Horizontal Left, Downflow/Horizontal Right Two Stage Condensing Gas-Fired Furnace

HIGH EFFICIENCY AIR HANDLER

Product Data. Split System Heat Pump 4TWR4018G1000A 4TWR4024G1000A 4TWR4030G1000A 4TWR4036G1000A 4TWR4042G1000A 4TWR4048G1000A 4TWR4060G1000A

Product Data. Side Discharge AC Models 4TTL6018A1000A 4TTL6024A1000A 4TTL6030A1000A 4TTL6036A1000A 4TTL6042A1000A 4TTL6048A1000A 4TTL6060A1000A

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

TECHNICAL GUIDE HIGH EFFICIENCY, STANDARD ECM VERTICAL WALL MOUNT AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: EWX*18-36

Split System Cooling Product Data

Advance Release September 2009

Product Data. Split System Heat Pump

DVPVC. Multi-Position, Variable-Speed Air Handler. Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV

Split System Cooling Product & Performance Data

SEER 1½

Transcription:

Submittal 5 Ton Convertible Air Handler TEM3A0C60S51SA SAFETY WARNING TAG: Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. July 2014 TEM3A0C60-SUB-1C-EN

Outline Drawing PRODUCT DIMENSIONS Air Handler Model A B C D E F H Flow Control TEM3A0C60S41SA 51.27 23.50 21.50 21.75 7.01 6 24.59 TXV 7/8 All dimensions are in inches Gas Line Braze 2 TEM3A0C60-SUB-1C-EN

Product Specifications MODEL TEM3A0C60S51SA RATED VOLTS/PH/HZ 208-230/1/60 RATINGS (a) INDOOR COIL Type See O.D. Specifications Plate Fin Rows F.P.I. 4-14 Face Area (sq. ft.) 5.91 Tube Size (in.) 3/8 Refrigerant Control Drain Conn. Size (in.) (b) DUCT CONNECTIONS INDOOR FAN Type TXV 3/4 NPT See Outline Drawing Centrifugal Diameter-Width (In.) 11 X 10 No. Used 1 Drive - No. Speeds CFM vs. in. w.g. Direct - 3 (c) See Fan Performance Table No. Motors H.P. 1-3/4 Motor Speed R.P.M. 1050 Volts/Ph/Hz 208-230/1/60 F.L. Amps 6.3 FILTER Filter Furnished? (d) REFRIGERANT Ref. Line Connections Coupling or Conn. Size in. Gas No R-410A Brazed 7/8 Coupling or Conn. Size in. Liq. DIMENSIONS 3/8 H x W x D Crated (In.) 52 1/2 x 26 x 24 Uncrated 51-3/8 x 23-1/2 x 21-1/8 WEIGHT Shipping (Lbs.) / Net (Lbs.) 145/138 (a) These Air Handlers are A.H.R.I certified with various Split System Air Conditioners and Heat Pumps (AHRI STANDARD 210/240). Refer to the Split System Outdoor Unit Product Data Guides for performance data. (b) 3/4 Male Plastic Pipe (Ref: ASTM 1785 76) (c) ECM motor (d) Remote filter required. Minimum Airflow CFM Heater BAYHTR1504BRK, BAYHTR1504PDC, BAYHTR1504LUG, BAYHTR1505BRK, BAYHTR1505PDC, BAYHTR1505LUG BAYHTR1508BRK, BAYHTR1508PDC, BAYHTR1508LUG, BAYHTR1510BRK, BAYHTR1510PDC, BAYHTR1510LUG, BAYHTR3510LUG BAYHTR1515BRK, BAYHTR3515LUG, BAYHTR1520BRK = Taps 1 3 TEM3A0C60S51SA Minimum Heat Speed Tap With Heat Pump Without Heat Pump TEM3A0C60-SUB-1C-EN 3

Heater Pressure Drop Table TEM Air Handler Models Airflow CFM Number of Racks Heater Racks 1 2 3 4 Heater Model No. of Racks Air Pressure Drop Inches W.G. BAYHTR1504 1 18 0.02 0.04 0.06 0.14 BAYHTR1505 1 17 0.02 0.04 0.06 0.14 BAYHTR1508 2 16 0.02 0.04 0.06 0.13 BAYHTR1510 2 15 0.02 0.04 0.06 0.12 BAYHTR3510 3 14 0.02 0.04 0.06 0.12 BAYHTR1515 3 13 0.02 0.04 0.05 0.11 BAYHTR3515 3 12 0.01 0.04 0.05 0.10 BAYHTR1519 4 11 0.01 0.03 0.05 0.09 BAYHTR1520 4 10 0.01 0.03 0.04 0.09 BAYHTR1521 4 9 0.01 0.03 0.04 0.08 8 0.01 0.03 7 0.01 0.02 6 0.01 0.02 4 TEM3A0C60-SUB-1C-EN

Performance and Electrical Data 1. See Product Data or Air Handler nameplate for approved combinations of Air Handlers and Heaters. 2. Heater model numbers may have additional suffix digits. Table 1. Air Flow Performance TEM3AOC60S51SA EXTERNAL STATIC (in w.g) AIRFLOW Speed Taps 208 230 VOLTS High Med 0.1 1954 1864 1780 0.2 1919 1827 1741 0.3 1885 1791 1704 0.4 1852 1756 1668 0.5 1821 1723 1633 0.6 1790 1691 1599 0.7 1761 1660 1567 1. Values are with wet coil, no filter, and no heaters 2. CFM Correction for dry coil = Add 3% 3. = Factory setting 4. = Taps 1 3, Med = Tap 4, High = Tap 5 5. BAYTEMDFKT1A must be used for downflow applications and airflow must not exceed 18 cfm due to condensate blow off. TEM3A0C60-SUB-1C-EN 5

Performance and Electrical Data Table 2. Electrical Data TEM3AOC60S51SA 240 Volt 208 Volt Heater Model No. No. of s/ Phases Capacity kw Minimum Ampacity BTU- H Heater Amps per Minimum Ampacity Maximum Overload Protection kw Capacity BTUH Heater Amps per Maximum Overload Protection No Heater 6.3 * 8 15 6.3 * 8 15 BAYHTR1504BRK BAYHTR1504PDC BAYHTR1504LUG 1/1 3.84 131-16.0 28 30 2.88 98 13.8 25 25 BAYHTR1505BRK BAYHTR1505PDC BAYHTR1505LUG 1/1 4.8 164-20.0 33 35 3.6 123-17.3 30 30 BAYHTR1508BRK BAYHTR1508PDC BAYHTR1508LUG 1/1 7.68 262-32.0 48 50 5.76 197-27.7 42 45 BAYHTR1510BRK BAYHTR1510PDC BAYHTR1510LUG 1/1 40.0 58 60 7.2 34.6 51 60 BAYHTR1515BRK- 1 (a) 2/1 40.0 58 60 7.2 34.6 51 60 BAYHTR1515BRK- 2 4.8 164-20.0 25 25 3.6 123-17.3 22 25 BAYHTR1520BRK- 1 (a) 2/1 40.0 58 60 7.2 34.6 51 60 BAYHTR1520BRK- 2 40.0 50 50 7.2 34.6 43 45 BAYHTR3510LUG 1/3 23.1 36 40 7.2 20.0 32 35 BAYHTR3515LUG 1/3 14.4 492-34.6 50 50 10.8 369-30.0 44 45 BAYHTR1515BRK with single circuit power source kit BAYSPEKT201A 1/1 14.4 492-60.0 83 90 10.8 369-51.9 73 80 BAYHTR1520BRK with single circuit power source kit BAYSPEKT201A 1/1 19.2 655-80.0 108 110 14.4 492-69.2 94 1 * = Motor Amps (a) MCA and MOP for circuit 1 contains the motor amps. 6 TEM3A0C60-SUB-1C-EN

Features and Benefits Painted metal cabinet with captured foil face insulation 2% or less air leakage R-4.2 Insulating Value Multi-Position UP/Down Flow, Horizontal Left /Right ALL Aluminum Coil with Enhanced Patented Coil Fin Electric Heaters with polarized plug connections (sold as accessory) R-410A Thermal Expansion Valve ECM Motor (5 Ton Models Only) Voltage Pigtail Connections Draw Through Design Horizontal Drain pan Single Color Fused 24V Power 1 year warranty 10-year warranty registered Optional extended warranty available Important: Condensate management kit is required for all 5 ton air handler models installed in downflow applications. Trane optimizes the performance of homes and buildings around the world. A business of Ingersoll Rand, the leader in creating and sustaining safe, comfortable and energy efficient environments, Trane offers a broad portfolio of advanced controls and HVAC systems, comprehensive building services, and parts. For more information, visit www.trane.com. Trane has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. 2014 Trane TEM3A0C60-SUB-1C-EN 04 Jul 2014 Supersedes TEM3A0C60-SUB-1B-EN (May 2014)