C-Bus 2 Channel Bus Coupler with Remote LED Facility Installation Instructions

Similar documents
C-Bus Four Channel Analogue Output Unit Installation Instructions

C-Bus Reflection Range Installation Instructions

C-Bus Neo Range Installation Instructions. 5050NL Series

C-Bus Four Channel General Input Unit Installation Instructions

Clipsal is a registered trademark of Clipsal Australia Pty Ltd. Saturn is a trademark of Clipsal Australia Pty Ltd.

C-Bus PIR Occupancy Sensor. Installation Instructions 5751L

C-Bus Bus Coupler with Scenes 5102BCLEDL 5104BCL

Light Level Detector, Surface Mount 5754PE. Installation Instructions

Square D Clipsal Outdoor Light-Level Sensor

C-Bus Pascal Automation Controller 5500PACA. Installation Instructions

StarServe IR/RF Controller Installation Instructions. 2031RFT Series

C-Bus Black & White MK II Desktop Touchscreen. 5000CTD2 Series. User s Guide REGISTERED DESIGN REGISTERED PATENT

C - B u s C - T o u c h U s e r s G u i d e C T Series

C-Bus Black & White MK II Touch Screen. 5000CT2 Series. User s Guide

Wireless Home Appliance Timer Remote Control Kit

ADEMCO 4208SNF V-Plex Universal Class A Module INSTALLATION AND SETUP GUIDE

DeLaval activity meter system Instruction Book

Atomic Digital Wall Clock

INSTALLATION GUIDE. AXIS A1001 Network Door Controller

Wireless Weather Station. Table of Contents

Trailing Edge Dimmer. 32E450T Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

FTP-1000 Touchpad/Display Installation Manual

Model: WS-9133U-IT Quick Setup Guide DC: WIRELESS FORECAST STATION

Ambient Weather WS-0211 Wireless Wendy the Weather Wizard User Manual

DIGITAL ATOMIC WALL CLOCK

Wireless Color Weather Station

Ambient Weather WS-26 Indoor Thermo-Hygrometer with Daily Min/Max Display User Manual

WIRELESS COLOR WEATHER STATION

Pure Glass. saturn.clipsal.com

Ambient Weather WS-091-C Three Channel Display Wireless Thermometer (Console Only) User Manual

180 Degree Ceiling Mounted Occupancy Sensors

WIRELESS COLOR FORECAST STATION

Model: C87207 / C87061 Instruction Manual DC: DUAL ALARM CLOCK

WIRELESS FORECAST STATION

Mood Light and Nature Sound Alarm Clock

MLHG6-AU. Iso-Gard Line Isolation Monitor (LIM) Setup Guide ! WARNING. Components

WIRELESS COLOR WEATHER STATION

Model: Quick Setup Guide DC: Atomic Projection Alarm Clock. Projection Lens. Buttons. Snooze/Backlight

1126 Series Ceiling Mount PIR Motion Detector

Model: T83653v2 Instruction manual DC: WIRELESS COLOR FORECAST STATION Mold Risk for Forecast Station & Indoor Remote Sensor Location

Ambient Weather WS-28 Indoor/Outdoor Thermometer with Daily Min/Max Display User Manual

Table of Contents. What s in the Box... 3 Power Requirements... 4 Quick Setup... 5 Lighting Guide With Ring, you re Always home.

Operation and Maintenance Manual

Model: WS-8147U-IT Instruction Manual DC: ATOMIC DIGITAL CLOCK WITH MOON PHASE

Fume Hood Operating Display Panel

RMS/RPX Reader. User Manual

Atomic Digital Office Clock

Ambient Weather WS Channel Wireless Thermometer with Min/Max Display User Manual

Model: Av2 Quick Setup Guide DC: Atomic Projection Alarm Clock

9000P Wireless Alarm Owner s Manual

ATOMIC DIGITAL CLOCK. Time and Alarm

WIRELESS WEATHER STATION

Atomic Projection Alarm Clock

Model: Quick Setup Guide DC: Atomic Projection Alarm Clock. Projection Lens. Buttons. Snooze/Backlight

Honeywell Temperature & Humidity Sensor with LCD

Installer Guide smart connect

MAJIK ENGLISH 11/20/02 11:30 AM Page 1 M A J I K O W N E R S M A N U A L

Ambient Weather RC-9362 Atomic Digital Wall Clock with Temperature User Manual

ShockLink. Important Product Information.

PERSONAL CUEING DEVICE MODEL NO. BDAAU100 INSTRUCTION MANUAL.

WIRELESS COLOR FORECAST STATION

Wireless Driveway and Intruder Alert

Model: v2 Quick Setup Guide DC: Atomic Projection Alarm with Indoor and Outdoor Temperature

Disclaimer. Trademarks. Copyright. Warranty

Ambient Weather WS-16 8-Channel Wireless Thermometer with Min/Max Display User Manual

Register the Gateway via PC. Package Content. Gateway Installation. 1 x Gateway 1 x Voice Siren 1 x IP Camera*

Atomic Digital Office Clock

Ambient Weather RC-8461 ClearView Jumbo Atomic Digital Wall Clock with Temperature and Humidity User Manual

Projection Alarm Clock

Ambient Weather WS-09 8-Channel Wireless Refrigerator/Freezer Thermometer User Manual

Installer Guide smart connect

Little Anne. Important Product Information

Installation and ZONES: Operation Manual. Model: ON STI-34108

WIRELESS TEMPERATURE & HUMIDITY STATION INSTRUCTION MANUAL

Ultrasonic Wall Switch Occupancy Sensor Single Circuit

Model: S88907 Instruction Manual DC: WIRELESS COLOR WEATHER STATION

Honeywell. Wireless Rain Gauge with Indoor. Temperature (TC152) USER MANUAL TABLE OF CONTENTS INTRODUCTION 3 PRODUCT OVERVIEW 4 REMOTE RAIN GAUGE 7

Voice Module Installation Guide. For use with ProSYS 16, ProSYS 40, ProSYS 128

Room Monitor SAVE THIS MANUAL FOR FUTURE REFERENCE.

TrailingE dge Dimmer. 32E450T Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

Twin Bell Digital Clock

Explorer F210 Fuel Instrument Installation and Operation Manual

Ambient Weather RC-8487 ClearView Radio Controlled Travel Alarm Clock with Indoor Temperature User Manual

Owner s Manual. PIR-1 IR Learner

2017 EcoFactor, Inc.

safety & regulatory information

AGES. instruction manual DAISY BLOOM PROJECTION ALARM CLOCK

Model:T83646v2 Quick Setup Guide DC: WIRELESS WEATHER STATION

IFT-RC150 IntelliFire Touch Remote Control Installation Instructions

Dimmer / Fan Controller Installation Instructions

Universal Dimmer. 31E2RUD Series ROTARY CONTROL. Installation Instructions. Integrally Switched Rotary Controlled INTEGRALLY SWITCHED 240V

SUNRISE ALARM CLOCK. With Multicolor LED Lights HME040187N. Before using your Sunrise Alarm Clock, please read this manual.

Wireless Rain Gauge with Indoor Temperature

HP Power Distribution Unit with Power Monitoring (Models S124 and S132) User Guide

MMF Six Zone Interface Module

SYSTEM ENHANCEMENT MODULE

PRODUCT DIAGRAM PACKAGE CONTENTS

HSD-200Z Z-Wave Motion Sensor

Wireless Thermostat (WTS10) Keypad Operation Guide

Instruction Manual SCD24. Read this document prior to installation. Contents

Transcription:

C-Bus 2 Channel Bus Coupler with Remote LED Facility Installation Instructions 5102BCLEDL REGISTERED PATENT

Table of Contents Section...Page 1.0 Product Range... 3 2.0 Description... 3 3.0 Capabilities... 3 4.0 Wiring Instructions... 4 4.1 Connection to the C-Bus Network... 5 4.2 Connection to Remote Switches and LEDs... 6 4.3 Programming Requirements... 7 5.0 Power Surges and Short Circuit Conditions... 8 6.0 Megger Testing... 8 7.0 Important Warning... 8 8.0 Standards Complied... 9 9.0 Product Specifications... 10 Copyright Notice Copyright 2004 Clipsal Integrated Systems Pty Ltd. All rights reserved. Trademarks Clipsal is a registered trademark of Clipsal Australia Pty Ltd. C-Bus and C-Bus2 are registered trademarks of Clipsal Integrated Systems Pty Ltd. Intelligent Building Series is a registered trademark of Clipsal Integrated Systems Pty Ltd. All other logos and trademarks are the property of their respective owners. Disclaimer Clipsal Integrated Systems reserves the right to change specifications or designs described in this manual without notice and without obligation. Copyright 2004 Clipsal Integrated Systems Pty Ltd. Page 2

1.0 Product Range 5102BCLEDL C-Bus Two Channel Bus Coupler with Remote LED s 2.0 Description The Two Channel Bus Coupler unit is a Key Input device allowing connection of voltage free mechanical switches into the C-Bus system. It offers the facility to connect external LED indicators via flying leads. The Learn Mode feature is also incorporated in this device, allowing a quick and easy way to program mechanical switches, to achieve various control functions such as: on/off, dimmer or timer. 3.0 Capabilities The Two Channel Bus Coupler facilitates remote access to C-Bus via any voltage free switch mechanism, such as the Clipsal 30M range. In this way the user can mix and match 2000 Series, Standard Range, Heritage Range, Metal Plate or Prestige Series style switch plates and products with C-Bus. Alternatively, reed, pressure, micro or other switches may be used to enhance the system flexibility. The Two Channel Bus Coupler is designed to use external LED s to indicate the condition of the being operated. These are connected to the unit via flying leads. Being an input device, the unit transmits messages to output devices to control load states. All C-Bus switching commands are available, including: on, off, toggle, timer and dimming functions etc. Dimming operations are best achieved using a spring return type switch such as the Clipsal 30MBPR Bell Press mechanism. The Two Channel Bus Coupler consumes 18mA of current and is counted as one C-Bus unit when considering the number of units connected to a Power Supply on the Network. Copyright 2004 Clipsal Integrated Systems Pty Ltd. Page 3

4.0 Wiring Instructions WARNING: The two channel inputs of the Bus Coupler are NOT isolated from the C-Bus Network. Take extra care when installing these devices ensuring all cables connected to C-Bus are well separated from mains. External switches must not be referenced to any other voltage source. To C-Bus Network CH.1 CH.2 1A 1K 2A 2K A K LED1 A LED2 K A K LED1 LINK A K LINK LED2 INDICATORS BOTH LEDS FITTED CH.1 LED FITTED CH.2 LED FITTED LINK LINK NO LEDS FITTED SW1 SW2 ANODE (A) CH.1 CH.2 REFER TO TABLE CATHODE (K) IMPORTANT The LED output connections must be made and maintained correctly for the unit to operate. The factory fitted wire link should only be removed if an LED connection is to be made. Flashing LED s are not compatible with this product. To minimise the amount of wire required (see section 4.2) a single common wire may be used as shown in the diagram below. To C-Bus Network SW1 SW2 CH.1 CH.2 Copyright 2004 Clipsal Integrated Systems Pty Ltd. Page 4

4.1 Connection to the C-Bus Network Installation of the Two Channel Bus Coupler requires connection to the unshielded twisted pair C-Bus Network Cable. Connection should be made using Category 5 data cable, catalogue number 5005C305B. The C-Bus Network Connection is polarity sensitive, and is clearly marked on the unit. One loop-in removable terminal block is provided for easy installation and maintenance. Ensure that correct colour coding (as shown below) is adhered to for trouble free operation. Blue + Orange, C-Bus Pos (+) Blue/White + Orange/White, C-Bus Neg (-) Brown + Brown/White, Remote OFF Green + Green/White, Remote ON C-Bus Connection Colour Bus Coupler Remote ON* Green/White Not Connected Remote ON Green Not Connected C-Bus Neg (-) Orange/White C-Bus Neg (-) C-Bus Pos (+) Blue C-Bus Pos (+) C-Bus Neg (-) Blue/White C-Bus Neg (-) C-Bus Pos (+) Orange C-Bus Pos (+) Remote OFF Brown/White Not Connected Remote OFF Brown Not Connected * The Two Channel Bus Coupler does not have Remote Override (On/Off) functions, however correct connections must be maintained for these services across the C-Bus Network. Copyright 2004 Clipsal Integrated Systems Pty Ltd. Page 5

4.2 Connection to Remote Switches and LEDs The C-Bus Bus Coupler with remote LED feedback enables the use of a wide range of conventional dry contact switch mechanisms, chosen on the basis of appearance, to indirectly switch C-Bus loads. The C-Bus Bus Coupler is designed to fit within the wall box behind switches. A small length of wire is used to connect these switches and remote LED s to the inputs and outputs of the C-Bus Bus Coupler. Insulated wire 1 with a diameter no greater than 2mm may be used to connect the voltage free switches and remote LED s to the Bus Coupler terminals. The maximum cable length is 1 metre per channel/led output, however the total length of cable connecting the remote switches and LED s to C-Bus Bus Couplers in a single network should be kept to 10 metres for good communications in a C-Bus system. (i.e. 5 channels, 5 LED s at 1m or 10 channels, 10 LED s at 500mm etc) If longer connections are required the 5104AUX or L5504AUX, which have input isolation, should be used as these units are specifically designed for such an application but do not offer remote LED indication. In all cases, switch input and LED connection wires should be segregated from mains wiring, any electrical noise sources and earthed metal structures in accordance with C-Bus wiring rules. If one or both LEDs are not being fitted, the unused LED output(s) must be shorted by link wire to maintain a connection. In order to facilitate off-site operation and programming without the need to fit LEDs, the unit is supplied with wire links fitted. IMPORTANT The LED output connections must be made and maintained as shown in the previous wiring diagram for the unit to operate. 1 Spring Loaded Terminal Description 1 Channel 1 Input C Switched Input Common ² 2 Channel 2 Input C Switched Input Common ² 1A LED 1 Anode 1K LED 1 Cathode ³ 2A LED 2 Anode ³ 2K LED 2 Cathode Insulated cables must be of a type conforming to requirements of the ACA Telecommunications labelling notice. ² The switched input Common is internally connected to C-Bus negative. ³ The 1K and 2A outputs are linked internally. Copyright 2004 Clipsal Integrated Systems Pty Ltd. Page 6

4.3 Programming Requirements The installer can program the unit in two ways, with the computer or using Learn mode. Whichever method is used, the Two Channel Bus Coupler must be assigned a unique unit address and a group address for each of the two channels. 4.3.1 Programming with a Personal Computer The latest C-Bus Service Pack is available for download from the Clipsal Integrated System's Web Site (www.clipsal.com/cis). This is available on the Downloads page along with other C-Bus products. For further information about programming this and other C-Bus units, please refer to the C-Bus Technical Manual (5000S/2, 5000M/2). 4.3.2 Programming without a Personal Computer using Learn Mode The Two Channel Bus Coupler is a C-Bus2 Input device, which allows users to set the relationships between Output Units and the Input Unit without a computer. Note: Each output unit which is to be associated with the Two Channel Bus Coupler in this way must be a C-Bus2 unit as well. Learn Mode provides a quick and simple way to program the C-Bus2 Input devices to provide basic functions. If more advanced functions are required see section 5.1 above. To program the Two Channel Bus Coupler to turn on loads by means of Learn Mode connect each channel of the Two Channel Bus Coupler to a conventional switch. Then do the following for each channel: Enter Learn Mode on a C-Bus2 output unit by holding down a toggle key on that unit for 10 seconds until the Unit and C-Bus indicators flash alternately. Select the toggle keys on the output unit associated with the loads you want to control. The selected indicators will illuminate. Flick the (non C-Bus) toggle switch you want to associate with the selected load on. The light on the Bus Coupler associated with this switch will light. Exit Learn Mode by pressing any toggle switch on an output unit for 2 seconds. Copyright 2004 Clipsal Integrated Systems Pty Ltd. Page 7

5.0 Power Surges and Short Circuit Conditions The mains voltage must be limited to the range specified for any unit that is mains powered. Each unit incorporates transient protection circuitry and additional external power surge protection devices should be used to enhance system immunity to power surges. It is strongly recommended that over-voltage equipment such as the Clipsal 970 series is installed at the switchboard. 6.0 Megger Testing Megger testing of mains cabling of an electrical installation that has C-Bus units connected will not cause any damage to C-Bus units. Since C-Bus units contain electronic components, the installer should interpret megger readings with due regard to the nature of the circuit connection. Megger testing must never be performed on the C-Bus data cabling or Bus Coupler input terminals as it may degrade the performance of the network. 7.0 Important Warning The use of any non C-Bus Software in conjunction with the hardware installation without the written consent of Clipsal Integrated Systems may void any warranties applicable to the hardware. Copyright 2004 Clipsal Integrated Systems Pty Ltd. Page 8

8.0 Standards Complied DECLARATIONS OF CONFORMITY European Directives and Standards Model 5102BCLEDL complies with the following: European Council Directive Standards Title 89/336/EEC EMC Directive EN 55014-1; IEC/CISPR 14-1 RFI Emissions Standard EN61000-3-2; IEC61000-3-2 RFI Emissions Standard EN60669-2-1; IEC 60669-2-1 RFI Emissions Standard BS/EN 61000-4-2 Immunity to ESD BS/EN 61000-4-3 Immunity to RFI BS/EN 61000-4-4 Immunity to EFT BS/EN 61000-4-5 Immunity to Surge Voltages BS/EN 61000-4-11 Immunity to Voltage Dips & Interruptions Australian/New Zealand EMC Framework and Standards Model 5102BCLEDL complies with the following: C-Tick Framework Standards Title EMC AS1044; IEC/CISPR14-1 RFI Emissions Standard AS/NZS61000.3.2; EN61000-3-2;IEC61000-3-2 RFI Emissions Standard U.S. FCC Regulations Model 5102BCLEDL complies with the following: Standards/Regulations FCC Title Part 15, Class B Digital Device for Home or Office Use Supplemental Information This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesirable operation Class B Product NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encourage to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio/tv technician for help Warning: Any changes or modifications not expressively approved by Clipsal Integrated Systems could void the user's authority to operate this equipment. Copyright 2004 Clipsal Integrated Systems Pty Ltd. Page 9

9.0 Product Specifications Parameter Description Catalogue Number 5102BCLEDL Two Channel Bus Coupler with Remote LED s C-Bus Supply Voltage 15-36V DC @ 18mA required for normal operation depending on LED output configuration (See table below for minimum operating voltages). Does not source current to the C-Bus Network. Current Drain 18 ma Voltage across Input when external 5V DC switch opens Voltage across Input when external 0V DC switch closes Switch closed current Less than 50µA Max cabling distance 1m Isolation between inputs Not isolated Isolation between inputs and C-Bus Not isolated Operating Temperature 0 45 o C Operating Humidity Range 10-95% RH C-Bus Terminals Removable terminals for wire size 0.2 1.5 mm 2 Two Channel Input/Output Side Spring loaded terminals for wire size 0.2 2.5mm 2 Weight 32g Dimensions 55 x 49 x 18mm (L x W x D) Minimum C-Bus operating voltage specifications LED output configuration Using two LEDs Using one LED and one link Using no LEDs and two links Minimum C-Bus operating voltage 15V + Sum of both LED forward voltages 15V + LED forward voltage 15V 55mm (2.17") 18mm (0.71") 49mm (1.93") No user serviceable parts inside. Copyright 2004 Clipsal Integrated Systems Pty Ltd. Page 10

Copyright 2004 Clipsal Integrated Systems Pty Ltd. Page 11

Further Information For further information about configuring this product and other C-Bus devices, please consult the documentation supplied. Further assistance can be obtained as follows: C-Bus Manuals The 5000M/2 C-Bus Technical Manual provides a comprehensive and definitive guide to Clipsal C-Bus. Includes hardware and software specifications, product datasheets, system design and installation guides, and software overview with fully worked programming examples. C-Bus Installation Software The 5000S/2 C-Bus Installation Software (includes 5000M/2 C-Bus Technical Manual) may be used to unlock the power and flexibility of Clipsal C-Bus. Unit operation may be completely customised to suit user requirements. Advanced control functions may be programmed. C-Bus Installer Training Courses Contact your nearest Clipsal Integrated Systems Sales or Technical Support Officer and enquire about Clipsal C-Bus Installer Training and Certification Programs today. Technical Support and Troubleshooting For further assistance, please consult your nearest Clipsal Integrated Systems Sales Representative or Technical Support Officer. Technical Support Hotline 1 300 722 247 (Cost 25 per call, Australia Only) Technical Support Email techsupport.cis@clipsal.com.au Sales Support Email sales.cis@clipsal.com.au Clipsal Integrated Systems Website clipsal.com/cis Products of Clipsal Integrated Systems Pty Ltd ABN 15 089 444 931 Head Office 12 Park Terrace, Bowden South Australia 5007 International Phone +61 8 8440 0500 International Fax +61 8 8346 0845 Internet clipsal.com/cis E-Mail cis@clipsal.com.au 1036494