Magnetostrictive sensor For bypass level indicators Model BLM

Similar documents
Indoor/outdoor resistance thermometer Model TR60


Gas cylinder scale Model GCS-1


Integrated Solutions Low Voltage Systems

Level Measurement Continuous level measurement Ultrasonic transmitters

Rosemount 3490 Series

Temperature Measurement Transmitters for field mounting

Model 144H. Product Data Sheet , Rev DB February Content

Quick Start Guide , Rev EA December Rosemount 0065/0185 Sensor Assembly

Annubar Flowmeter Series

Model 144H. Product Data Sheet , Rev DB February Content

Universal controller for panel mounting Models CS6S, CS6H, CS6L

Illumination unit For sight glass level indicator Model LGI

Incus Ultrasonic Gas Leak Detector Wide Area Coverage for Pressurized Gas Leaks

Guide to Hazardous Location Approvals:

Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Ultrasonic Level Measurement nivopuls FDU 10 S

Technical Data. Dimensions

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

PEPPERL+FUCHS GmbH

Flameproof Manual Call Points Series MCP

Technical Data. Dimensions

Rosemount 0085 Pipe Clamp Sensor Assembly. Quick Start Guide , Rev CA June 2016

OPTIWAVE X500 Supplementary Instructions

Rosemount 2090F Hygienic Pressure Transmitter

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

Technical Data. Dimensions

Technical Data. General specifications. Rated operating distance s n 5 mm

INTRINSICALLY SAFE LIGHTING RANGE

Manual Isolating Barrier D461 (Revision 05)

OPTIBAR DP 7060 Supplementary Instructions

MT3750C Series. Metal Tube Variable Area Flowmeters. Ships in 5 days. Overview. Product Description. Features. Variable Area

HOW LIMIT AND BASIC SWITCHES CAN STOP MACHINES FROM GOING BOOM. A Honeywell White Paper

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Operating instructions for HAWE devices

Rosemount 752 Fieldbus Remote Indicator

Trusted worldwide since 1989 INTRINSICALLY SAFE RANGE

Rosemount 752 FOUNDATION Fieldbus Remote Indicator

TX6831 Data Sheet. Features. Benefits

Rosemount 214C Sensor. Quick Start Guide , Rev AF August 2017

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

Technical Data. Dimensions

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

User s Manual YTA610 and YTA710 NEPSI Certification

Continuous level measurement Ultrasonic transmitters

Enraf Servo Gauge 854 XTG

Rosemount 0085 Pipe Clamp Sensor Assembly. Quick Start Guide , Rev DC August 2017

Multiple Status Indicators Series MEXE, MS25, MS35, MS45, MS55

Azbil introduction 2015

IS (Intrinsic safety) - Ex (Epsilon x) ATEX CENELEC

Rosemount 3144P Rosemount 3144P Temperature Transmitter

Dräger Polytron 8000 Stationary gas detector (EC)

SITRANS T temperature transmitters A broad product family for every application. sitrans

Quick Start Guide , Rev DA December Rosemount Volume 1 Sensor Assembly

Rosemount 2090P Pulp and Paper Pressure Transmitter

Rosemount 4600 Oil & Gas Panel Pressure Transmitter. Quick Start Guide , Rev GA September 2017

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

ULTIMA X5000. MSAX5000.com

Rosemount 2090F Hygienic Pressure Transmitter

Functional safety manual Liquiphant M/S with FEL57 and Nivotester FTL325P

CA 134. Piezoelectric accelerometer. IECEx NEPSI TIIS KGS. » From the Vibro-Meter product line» Vibration monitoring over a wide temperature

EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S

Temperature measurement with SITRANS T siemens.com/processinstrumentation

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

Cable Glands DB Series: Drain, Breather Valves and Unions

Operating Manual MS220DA

Flame Monitors BROCHURE

MT3809G Series. Data Sheet. Metal Tube Variable Area Flowmeters. Overview. Product Description. Variable Area

Bristol Babcock Oil Content Monitor "oil in water"

EXPLOSION PROTECTION

ProcessMaster, HygienicMaster FEX300, FEX500

Level Measurement Continuous level measurement - Ultrasonic transmitters

Level gauges Series LS Level indicator, switch and transmitter for liquids

Instructions. Det-Tronics SmokeWatch Explosion Proof Smoke Detector U Rev: 3/

SmartPower Solutions. Quick Start Guide , Rev CA March 2015

Understanding Hazardous Locations Concepts

MT3809G Series. Metal Tube Variable Area Flowmeters. Overview. Product Description. Variable Area

Functional Safety Manual Oil Leak Detector NAR300 System

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

CE110I. Piezoelectric accelerometer with integrated electronics. IECEx

OPTIBAR P 1010/2010 C Supplementary instructions

UL HAZARDOUS LOCATIONS SERVICES

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

Level instruments. Continuous level measurement - Ultrasonic transmitters. SITRANS Probe LU. Overview. Configuration

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

Basic Ex products / Zone 1, 21

Ar-Mite TM Low Flow Armored Flowmeter

Quick Start Guide , Rev CB May Rosemount 3144P Temperature Transmitters with FOUNDATION fieldbus Protocol

How Limit Switches Can Stop Machines from Going Boom

Additional Information. Introduction. Temperature transmitter for all communications protocols. Redundancy thanks to two inputs. Measurement made easy

SECTION INDUCTIVE CONDUCTIVITY ANALYZERS

Rosemount 2088, 2090P, and 2090F Pressure Transmitters

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here.

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Transcription:

Level Magnetostrictive sensor For bypass level indicators Model BLM KSR data sheet LM 10.05 for further approvals see page 2 and 3 Applications Sensor for the continuous level measurement of liquids in bypass level indicators Chemical and petrochemical industries, offshore Shipbuilding, machine building Power generating equipment, power plants Pharmaceutical, food, water treatment, environmental engineering industries Special features Continuous level measurement on the outside of the bypass 2-wire technology 4... 20 ma Measured value output via digital interface and a selectable measured value as analogue signal Case from stainless steel (display from glass) Magnetostrictive level measuring instrument with high resolution Magnetostrictive sensor, model BLM Description Level sensors with a magnetostrictive, high-resolution measuring principle are used for continuous level measurement of liquids and are based on determining the position of a magnetic float following the magnetostrictive principle. The level sensors are mounted on the outside of a bypass level indicator. The measuring process is triggered by a current impulse. This current produces a circular magnetic field along a wire made of magnetostrictive material, which is held under tension inside the sensor tube. At the point being measured (liquid level) there is a cylindrical float with permanent magnets acting as a position transducer, whose field lines run at right angles to the impulse magnetic field. This magnetic field of the float tensions the wire. The superposition of these two magnetic fields triggers a mechanical wave in the wire. This is converted into an electrical signal at the end of the wire in the sensor housing by a piezoceramic pick-up. The measured propagation delay enables the origination point of the mechanical torsional wave, and thus the float position, to be determined with high accuracy. Page 1 of 9 A division of the WIKA group

Illustration of the principle Permanent magnet Wire Torsional wave Permanent magnetic field Impulse magnetic field Torsional wave Model overview Model BLM-S: Standard version Model BLM-SI (FFG-BP): Intrinsically safe (Ex i) Model BLM-SD (FFG-BP): Flameproof enclosure (Ex d) Model BLM-T: Compact version Model BLM-TI (FFG-BT): Compact version, intrinsically safe (Ex i) Model BLM-SF-FM: FM version Approvals Model BLM Logo Description Country EU declaration of conformity EMC directive RoHS directive European Union EAC (option) EMC directive No. RU Д-DE.A301.B.00820 GOST (option) No. 19359 KazInMetr (option) No. 13947 BelGIM (option) No. 9710 UkrSEPRO (option) No. UA-MI/2-4988-2015 Uzstandard (option) No. 02.6649 Eurasian Economic Community Russia Kazakhstan Belarus Ukraine Uzbekistan Page 2 of 9

Models BLM-SI, BLM-SD, BLM-TI, BLM-SF-FM Logo Description Country ATEX directive (option), models BLM-SI, BLM-SD, BLM-TI Hazardous areas European Union Models BLM-SI, BLM-SD - Ex i Zone 1 II 2G Ex ia IIB T3... T6 No. ZELM 10 ATEX 0439 - Ex d Zone 1 II 2G Ex d IIB T3... T6 Gb No. ZELM 13 ATEX 0508 X Model BLM-TI - Ex i Zone 1 II 2G Ex ib IIC T3... T6 No. IBEXU 02 ATEX 1124 X FM (option), model BLM-SF-FM Hazardous areas XP, class I, division I, groups A, B, C, D DIP, class II, division I, groups E, F, G EAC (option) Hazardous areas No. RU C-DE.ГБ08.B.01489 No. FM16US0415X No. FM16US0415X USA Eurasian Economic Community NEPSI (option), models BLM-SI, BLM-SD Hazardous areas - Ex i [Ex ia IIC T1... T6 Ga] No. GYB16.1498 - Ex d [Ex d IIC T1... T6 Gb] No. GYB16.1433X China Manufacturer s information and certificates Logo Description SIL 2 Functional safety - China RoHS directive Approvals and certificates, see website Page 3 of 9

Magnetostrictive sensor, standard version Model BLM-S 52 90 ML 60 174 110 Connection housing (sensor housing) Stainless steel 1.4404 Version with or without display, with window Sensor tube Medium temperature -60... +185 C Ambient temperature Version without display Version with display Stainless steel 1.4571, tube Ø 12 mm, tube length L max. 5,800 mm -40... +85 C -20... +70 C Output signal 4... 20 ma, HART Load DC 15... 30 V < ±0.5 mm < 0.1 mm max. 900 Ω at 30 V Mounting position Vertical ±30 IP67 Page 4 of 9

Magnetostrictive sensor, intrinsically safe (Ex i) Models BLM-SI, BLM-SD 52 90 ML 60 174 110 Connection housing (sensor housing) Stainless steel 1.4404 Version with or without display, with window Sensor tube Medium temperature -60... +185 C Ambient temperature Ex i version Ex d version without display Ex d version with display Output signal 4... 20 ma, HART Load Stainless steel 1.4571, tube Ø 12 mm, tube length L max. 5,800 mm T3/T4/T5/T6: -20... +70/+70/+70/+60 C T3/T4/T5/T6: -40... +70/+70/+70/+60 C T3/T4/T5/T6: -20... +70/+70/+70/+60 C DC 15... 30 V < ±0.5 mm < 0.1 mm max. 900 Ω at 30 V Mounting position Vertical ±30 IP67 Page 5 of 9

Magnetostrictive sensor, compact version Model BLM-T Ø 50 50 ML 100 116 Connection housing (sensor housing) Stainless steel 1.4305, optionally stainless steel 1.4404 Sensor tube Stainless steel 1.4571, optionally stainless steel 1.4404 Tube Ø 12 mm, tube length L max. 6,000 mm Medium temperature -60... +185 C Ambient temperature -40... +85 C Output signal 4... 20 ma, HART DC 8... 30 V < ±0.5 mm < 0.1 mm IPx6, IP68 Page 6 of 9

Magnetostrictive sensor, compact version, intrinsically safe (Ex i) Model BLM-TI Ø 50 50 ML 100 116 Connection housing (sensor housing) Stainless steel 1.4305, optionally stainless steel 1.4404 Sensor tube Stainless steel 1.4571, optionally stainless steel 1.4404 Tube Ø 12 mm, tube length L max. 6,000 mm Medium temperature -60... +185 C Ambient temperature T4/T5/T6: -20... +85/+55/+40 C Output signal 4... 20 ma, HART DC 10... 30 V < ±0.5 mm < 0.1 mm IPx6, IP68 Page 7 of 9

Magnetostrictive sensor, FM version Model BLM-SF-FM 52 108 ML 61 138 Connection housing (sensor housing) Stainless steel 316L/316FC Version with or without display, with window Sensor tube Stainless steel 1.4571 Tube Ø 14 mm, tube length L max. 4,000 mm Medium temperature -200... +180 C Ambient temperature -25... +70 C Class I, division 1, groups A, B, C, D; T6... T2 T a = -25... +70 C Class II, division 1, groups E, F, G and class III, division 1; T6... T3 T a = -25... +70 C Output signal 4... 20 ma, HART 7 DC 16... 30 V ±0.5 mm 0.1 mm IP67 Page 8 of 9

Ordering information To order the described product the order number (if available) is sufficient. Alternatively: Sensor model / Electrical connection / Sensor tube (material and overall length) / Measuring range / Approval 08/2014 KSR KUEBLER Niveau-Messtechnik AG, all rights reserved. The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials. 04/2018 EN Page 9 of 9 A division of the WIKA group KSR KUEBLER Niveau-Messtechnik AG Heinrich-Kuebler-Platz 1 69439 Zwingenberg/Germany Tel. +49 6263/87-0 Fax +49 6263/87-99 info@ksr-kuebler.com www.ksr-kuebler.com