California Title 24 2013 Lighting and Lighting Controls Only Scope: Title 24 2013 Residential Compliance Date: July 29, 2014
Outline Scope of Residential Compliance Key definitions When Title 24 compliance is required Spaces Structure for code Solutions for Title 24 2013 compliance 2
Scope of Residential Compliance Single Family Home Multi-Family Home High-Rise Home Dormitory Senior Living Quarters Hotel / Motel / Guest Rooms Title 24 Occupancy Types include R-1, R-2, R-3, and R-4. CEC is clarifying the full scope that touches upon the living spaces, dwellings, of these types. With additional requirements 3
Key definitions Certified to Title 20 Appliance Database (T20) Repository of products manufactures report meet the requirements of the appliance codes For residential, includes self-contained lighting controls and LED luminaires Occupancy Group Classification of that defines the compliance types of a space Residential Compliance only applies to a portion of Group R and Group U (Group U, when located on Single Family lot) Location of circuit Critical to know how the lighting products are switched Control switch/circuit in a space will determine the compliance requirements Example: When a dining room switched from the kitchen, code requires the dining room lighting meet the kitchen code requirements. Used in Resident Compliance ONLY Lighting products reported by manufacturers meeting the code requirements Requirements and reporting vary by technology type (i.e.: LED luminaires T20, CFL luminaires using T20 CFL ballasts) Used in Residential Compliance ONLY Lighting products that are NOT reported by manufactures meeting high efficacy code requirements Self-contained Lighting Controls Control module that requires no additional component to be fully functional Must be certified to Title 20 Appliance Database to be sold in California for California use 4
When Title 24 Code compliance is required Single Family All Other Residential New Construction New Construction Additions Additions Alterations LED Module Note Alterations 10% Luminaires Modificationin-Place Not discussed Modificationin-Place 40 Luminaires, 1:1 Replace Repair Not discussed Repair Not discussed 5
Spaces Structure of code Kitchens Bathrooms Garages, Laundry Rooms and Utility Rooms Other Rooms Outdoor Single Family Outdoor Multi-Family / High-Rise 6
Kitchens 50% Power must be high efficacy CFL luminaires with T20 ballasts, GU-24, T20 LED luminaires IC/AT recessed housing GU-24 & non-incandescent Linear Fluorescent with T20 certified ballast 90CRI Certified to T20 Coming Soon Must not exceed 50% power Products that are not, qualify 80CRI LED / Non-T20 Ballasts Coming Soon SLD LED EL4 LED ELG4 LED ML56 LED HU10 LED RL56 LED RL4 LED 806/07 ML56LED HU20 LED LV/H SCN WN RA56 LED P3LED Non-Incandescent IC/AT Housings IC/AT Housings H457 H457R H750 H750R H724G24 H724RGU24 P3 H7 H7R H36/38 H36R H570 H571R Controls: and MUST be separately circuited Rooms switched from kitchen are considered part of the kitchen Controls are NOT required but recommended 7
Bathrooms At least 1 luminaire must be high efficacy CFL luminaires with T20 ballasts, GU-24, T20 LED luminaires IC/AT recessed housing GU-24 & non-incandescent Linear Fluorescent with T20 certified ballast 90CRI Certified to T20 Coming Soon Separate circuit from Products that are not, qualify 80CRI LED / Non-T20 Ballasts Coming Soon SLD LED EL4 LED ELG4 LED ML56 LED HU10 LED RL56 LED RL4 LED 806/07 ML56LED HU20 LED 601 600 WN RA56 LED P3LED Non-Incandescent IC/AT Housings IC/AT Housings H457 H457R H750 H750R H724G24 H724RGU24 P3 H7 H7R H36/38 H36R H570 H571R Controls: and MUST be separately circuited controlled by T20 Vacancy Sensor ONW VNW 8
Garages, Laundry, Utility Rooms ALL luminaires must be CFL luminaires with T20 ballasts, GU-24, T20 LED luminaires IC/AT recessed housing GU-24 & non-incandescent Linear Fluorescent with T20 certified ballast Not allowed 90CRI Certified to T20 Controls: Coming Soon T20 Vacancy Sensor ONW VAC SLD LED EL4 LED ELG4 LED ML56 LED HU10 LED RL56 LED RL4 LED RA56 LED Non-Incandescent IC/AT Housings H457 H457R H750 H750R H724G24 H724RGU24 P3 H995 9
Other Rooms (Not previously covered) Can be ALL and controls not required CFL luminaires with T20 ballasts, GU-24, T20 LED luminaires IC/AT recessed housing GU-24 and non-incandescent Linear Fluorescent with T20 certified ballast 90CRI Certified to T20 Coming Soon If, must be controlled Products that are not, qualify 80CRI LED / Non-T20 Ballasts Coming Soon SLD LED EL4 LED ELG4 LED ML56 LED HU10 LED RL56 LED RL4 LED 806/07 ML56LED HU20 LED H2522/23 SCN 240 RA56 LED P3LED Non-Incandescent IC/AT Housings WN H2524 IC/AT Housings H457 H457R H750 H750R H724G24 H724RGU24 P3 H7 H7R H36/38 H36R H570 H571R Controls: MUST be separately circuited MUST be controls by a vacancy sensor OR dimmer ONW VNW CLS 10
Single Family Outdoor (Attached to any building) Can be ALL and controls not required CFL luminaires with T20 ballasts, GU-24, T20 LED luminaires, High Pressure Sodium, Pulse Start Metal Halide <150W, T20 Pulse Start Metal Halide 150W IC/AT recessed housing GU-24 and non-incandescent Linear Fluorescent with T20 certified ballast Certified to T20 / Non-Incandescent IC/AT If not, must be controlled LED, INC, CFL, and HID FE VT GP FSL MS MST XTOR SLD LED ML56 LED RL56 LED H457 H457R H750 H750R 714 903 303 HID / CFL W PFL23 MD FFL23 Controls: manual ON/OFF does not override ON automatic actions When, T20 Motion Sensor AND T20 Photocontrol, T20 Astronomical Time Clock, or EMS 11
Low-Rise Multi-Family Outdoor (Can comply with non-residential compliance instead) Can be ALL and controls not required CFL luminaires with T20 ballasts, GU-24, T20 LED luminaires, High Pressure Sodium, Pulse Start Metal Halide <150W, T20 Pulse Start Metal Halide 150W IC/AT recessed construction when used: GU-24 and non-incandescent Linear Fluorescent with T20 certified ballast Certified to T20 / Non-Incandescent IC/AT If not, must be controlled LED, INC, CFL, and HID FE VT GP FSL MS MST XTOR SLD LED ML56 LED RL56 LED H457 H457R H750 H750R 714 903 303 HID / CFL W PFL23 MD FFL23 Controls: manual ON/OFF does not override ON automatic actions When, T20 Motion Sensor AND T20 Photocontrol, T20 Astronomical Time Clock, or EMS 12
High-Rise Family Outdoor (Attached to the building) Can be ALL and controls not required CFL luminaires with T20 ballasts, GU-24, T20 LED luminaires, High Pressure Sodium, Pulse Start Metal Halide <150W, T20 Pulse Start Metal Halide 150W IC/AT recessed housing GU-24 and non-incandescent Linear Fluorescent with T20 certified ballast Certified to T20 / Non-Incandescent IC/AT If not, must be controlled LED, INC, CFL, and HID FE VT GP FSL MS MST XTOR SLD LED ML56 LED RL56 LED H457 H457R H750 H750R 714 903 303 HID / CFL W PFL23 MD FFL23 Controls: High-Rise, considered residential when switched from inside dwelling manual ON/OFF does not override ON automatic actions When, T20 Motion Sensor AND T20 Photocontrol, T20 Astronomical Time Clock, or EMS 13
References California Title 20 Appliance Database search tool (http://www.appliances.energy.ca.gov/default.aspx) California Title 24 2013 Building Energy Efficiency Standards main website (http://www.energy.ca.gov/title24/2013standards/) California Title 24 2013 Residential Compliance Manual website (http://www.energy.ca.gov/title24/2013standards/residential_manual.html) California Title 24 2013 Residential Compliance Manual Residential Lighting document (http://www.energy.ca.gov/2013publications/cec-400-2013- 001/chapters/06_Residential_Lighting.pdf) 14
15