HPIC Meeting - Austin

Similar documents
ORTEC. Detective-Remote. Multiple Instrument Remote Monitoring and Control Software. The right software, the right solution, the right answer!

DSP EC Pro. Advanced, Digital Gamma-Ray Spectrometer for HPGe Detector Systems

Portable Instruments For First Response & In-Situ Analysis of Radiation

North American Technical Services

ORTEC DSPEC LF. High-Performance Digital Signal Processor for Gamma Spectroscopy. ... in a compact package at an economical price.

Detective-200. Ruggedized, Ultra-High-Sensitivity, Transportable HPGe Radionuclide Identification System

Instrument Standards Used in Security Applications Presented by: Leticia Pibida, Ph.D.

HIGHLY SENSITIVE FOR NUCLEAR POWER PLANTS Real-Time Continuous Water Monitor

Performance of a New Type of Electrical Cooler for HPGe Detector Systems

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System

Setting the new standard for personal radiation detection.

NEXT GENERATION DRINKING WATER RADIATION SAFETY MONITOR

Radiation Monitoring Systems

RIID capability in the palm of your hand

NEW COOLING OPTION FOR DETECTORS

Pico Envirotec Inc., CA & ENVINET a.s., CZ NEW APPROACH TO GLOBAL MONITORING OF THE RADIOLOGICAL SITUATION; INDUSTRIAL, ENVIRONMENTAL & EMERGENCY

Detecting Radiation. Protection through Detection. February Animations in this training work best in Windows XP

ICS Integrated Cryocooling System

Unattended Radiation Sensor Systems for Remote Terrestrial Applications and Nuclear Nonproliferation

COUNTING ROOM EQUIPMENT RCT STUDY GUIDE

SEAWATER RADIATION DETECTION SYSTEM WATER PROTECTION

dewar or an electrically powered cooler. The sensitive detector surfaces are thus protected from moisture and condensable contaminants.

LARGE VOLUME HEMISPHERICAL NUCLEAR RADIATION DETECTOR CZT/500(S)

AERIAL RADIATION DETECTORS

Depleted Uranium Waste Assay at AWE. T.J. Miller AWE, Aldermaston, Reading, Berkshire, England, RG7 4PR UK

AERIAL RADIATION & CHEMICAL DETECTION SYSTEM. DroneSENSOR TM Series. Particulate Alpha, Beta, Gamma & Airborne Chemicals

ICS Integrated Cryocooling System

ICS Integrated Cryocooling System

Tender Specifications. Supply of radiation detection equipment for EUSECTRA training centre Lot 2: Backpack for portable radiation detection system

LAUNDRY MONITORING SYSTEM Model # LIM-64S

Advanced Radiation Detection Equipment

The European Commission s science and knowledge service. Building on core components of Technical Reachback

Practical Use of the Mobile Radiological Laboratory to Support the Nuclear Regulatory Authority of Ukraine

COMPACT RADIOACTIVE AEROSOL MONITORING DEVICE FOR EARLY WARNING NETWORKS

Presented by: Dr. Francesco Pellegrino Lockheed Martin Corporation Maritime Systems and Sensors Mitchel Field, New York

Federal Bureau of Investigation. Training. Agenda. Acronym City. SRNL Counterterrorism and Homeland Security Support Areas

MÖBIUS Recycler Condensing Liquid Nitrogen HPGe Detector Cooling System

CZT/NaI Hybrid Hand-Held Performance Evaluation

Fundamentals is subdivided into Sources of Radiation, Biological Effects, Mathematics, Chemistry, Physics, and Units and Terminology.

WM2012 Conference, February 26 March 1, 2012 Phoenix, Arizona, USA

arxiv: v1 [physics.ins-det] 14 Apr 2014

Domestic Nuclear Detection Office (DNDO)

PORTABLE or FIXED PERSONNEL & VEHICLE MONITOR

Mass Sensors, Inc. Profile. Applications. Technology Baur Blvd, St. Louis, MO (314)

NEX-BETA-ABG FACILITY Drinking Water Safety Monitor

American Nuclear Society (ANS)

Countering Nuclear Smuggling in Lithuania: Detection Mr Albinas Mastauskas Director, Radiation Protection Centre LITHUANIA

Portable Survey Instruments NISP-RP-01

The Majorana Demonstrator Update and Detector Technologies

Highlights from a recent test campaign in Finland with scalable neutron detectors

Highlights of Germanium Detector technology

Our Extended Personal Electronic Dosimeter (PED) Family

Any scenario. Maximum protection. Radiation detection solutions for safety and security

Domestic Nuclear Detection Office (DNDO)

Advanced Radiation Measurement Solutions

Communications. Sensing. Instrumentation. Delivering tomorrow s optical and photonic solutions today. BREAKTHROUGH PHOTONIC PRODUCTS

TECHNICAL LEAFLET. The proposed instrument is an extended version of the computerized Geiger-Muller indicator PT

ADVANCED RADIATION DETECTION EQUIPMENT

The Development of an Integrated Site System for the detection of illicit trafficking of radioactive and nuclear materials

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA

IAEA-SM-367/14/01 UTILIZATION OF FLUORESCENT URANIUM X-RAYS AS VERIFICATION TOOL FOR IRRADIATED CANDU FUEL BUNDLES

GERDA Phase II Detectors and Acceptance Tests

Any scenario. Maximum protection.

for Photonics Advanced phosphor and glass technologies for high performance alignment, detection, imaging and spectroscopy applications

NUCLEAR INDUSTRY STANDARD PROCESS Radiological Protection. Level 3 Information Use

A bright alpha numeric display and the simplified keypad (three buttons) allow the operation even under harsh conditions.

AIR or STACK MONITOR NOBLE GAS, GROSS BETA-GAMMA PARTICULATE, & IODINE. Optional Alpha, Tritium, Carbon-14

A FIRST RESPONDERS GUIDE TO PURCHASING RADIATION PAGERS

Protecting our Borders while Ensuring Radiation Safety

Detector Configurations for the MAJORANA Demonstrator

Domestic Nuclear Detection Office (DNDO)

Mission 份有限公司 wwwom 先锋科技股份有限公司 www Working with our customers we identify, design and deliver low light detection solutions which solve customer probl

Portable Alpha/Beta Continuous Online Air Monitor (CAM)

Detecting and Using Radiation in Security Application

Utilization of advanced clutter suppression algorithms for improved standoff detection and identification of radionuclide threats

GEOPHYSICAL ENVIRONMENTAL ANALYSIS EQUIPMENT AND SERVICES

MÖBIUS Recycler. Condensing Liquid Nitrogen HPGe Detector Cooling System

The Problems Related to Orphan Radioactive Sources in Scrap Metal (Georgian Experience)

Recent Advances in Mercuric Iodide Detector Fabrication and Instrument Development*

Development of a mobile facility for monitoring of radioactivity in food during an emergency

Summary. Assessment Methodology

TacBio: A UV-based Biological Aerosol Detector. TacBio Overview Page 1

Assessment of factors causing false alarm signals from detection equipment, and ways to mitigate this challenge

INTERNATIONAL STANDARD

XGLAB. X and Gamma Ray Electronics. Looking for new frontiers...

TRITIUM IN WATER MONITOR REAL TIME CONTINUOUS Model # LIQ-X-(H3)

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA PARTICULATES

Domestic Nuclear Detection Office (DNDO)

A Continuous Air Monitoring Sampler for 125 I - RIS-125

Products & Solutions for Military Customers

Remote Gamma Imaging of High Dose Environments

CBRNE solutions to safeguard society.

List-mode Data Acquisition a New IEC Standard

ISO 3999 INTERNATIONAL STANDARD. Radiation protection Apparatus for industrial gamma radiography Specifications for performance, design and tests

Energy and Angular Responses of the Criticality Accident Alarm System Using Current-mode-operated Scintillation Detector

The French experience on nuclear detection architectures and related reachback Laurent OLMEDO

SuperCDMS SNOLAB: Road to 100 mm Germanium Detectors

AERIAL RADIATION DETECTION

SVG 2 and Probes. Innovation with Integrity. The new Generation of Semiconductor Radiation Meters and Handheld Radiation Detection Probes

safe and your operations compliant

Transcription:

HPIC Meeting - Austin Barry Wilson Key Account Manager South West ORTEC 1

Who is ORTEC? Parent Company is AMETEK NYSE ticker AME Subsidiary Name is Advanced Measurement Technologies Inc. Brand Names are ORTEC, Princeton Applied Research and Signal Recovery ORTEC was founded in 1960 by Researchers from ORNL to build commercial charged particle detectors made of semi-conductor materials (silicon). Currently about 280 employees world-wide. Factory in Oak Ridge 2

Key Technology: HPGe Detectors ORTEC is a world leader in nuclear instrumentation, including both growing HPGe crystals and fabricating detectors. ORTEC has significant experience in large scale production of HPGe detectors for a variety of projects. 3

Key Technology: DSP Hardware ORTEC was first to commercialize Digital Signal Processing (DSP) technology in an integrated gamma ray spectrometer. ORTEC holds nine separate patents in the area of DSP based MCA technology alone. 4

Key Technology: Coolers Electromechanical cooling system for Fixed/Installed Applications Portable Cooling System for the Field Since 1984, ORTEC has delivered more LN2 free HPGe cooling systems than any company in the world. Patented Low Frequency Rejection digital filtering makes it work. Hundreds of reliable systems delivered per year. 5

Key Technology: Software Found Industrial(1) Suspect NORM(1) Found Nuclear Uranium High degree of collaboration with national laboratories for state of the art analysis methods. Broad-based software group continually working on an equally broad range of new products (both nuclear and otherwise) ensures we keep up with technology. 6

Radiological/Nuclear Terrorism Preventing the Spread of Illicit Nuclear Materials 7

Potential Points of Entry 8

The Cost of False Alarms False Positives (nuisance alarms) 90% of innocent alarms at airports are due to medical isotopes in the bodies of travellers In cargo/freight, the major problem is caused by natural emitters. Suspending operations in just one terminal for just one hour could cost close to $500,000, said Bethann Rooney, Port Authority s Manager of Port Security, New York Harbor. False Negatives Report cargo is clean when in fact a source is hidden inside 9

Review: Why use HPGe? Plastic HPGe NaI CZT LaBr 10

Shielded Plutonium with Barium Barium Plutonium 11

Plutonium with 133 Ba Mask Peaks from 133 Ba intermingle with plutonium peaks Shielded with 5 mm steel Collection time for identification is 5 seconds The 133 Ba lines are separated from the 239 Pu lines allowing the identification software to identify plutonium 12

Enter the DETECTIVE Portable Nuclide Identifiers! Detective DX/EX & MicroDetective One button sophisticated search/identify tool for non-scientist users Unique Combination of exclusive technologies ORTEC Germanium detector with miniature Sterling engine cooler ORTEC Digital signal processing electronics, embodying several patents Special ID software licensed from the LLNL Radscout 13

DETECTIVE DX/EX Common Hardware Features 50x30mm or 65x50mm HPGe detector Run for ever Cooler Gamma ID and Gamma Dose rate Digital MCA 8K channels ~11 Kg weight (EX~12Kg) Battery operation >3Hr Battery Extender = 8hr Docking station optional Hardened cryostat 14

DETECTIVE DX/EX differences EX adds Highly sensitive neutron detection -- 4 x 3 He tubes - 4" active length, 0.5" diameter, 20atm. HDPE moderator Color Touch Screen Display on DX and EX DX and EX unlimited data storage on removable media 15

The Nuclides Industrial Including, but not limited to 57 Co, 60 Co, 133 Ba, 137 Cs, 192 Ir, 241 Am, 75 Se Medical Including, but not limited to 18 F, 67 Ga, 99m Tc, 111 In, 123 I, 131 I, 133 Xe, 201 Tl Natural (NORM) Including, but not limited to: 40 K, 226 Ra, 232 Th, 238 U Nuclear Including, but not limited to 233 U, 235 U, 237 Np, 239 Pu, 252 Cf 16

All versions are simple in use... DX/EX & Micro Clear touch screen (use stylus or finger) 17

PRIMARY ID SCREENS, Classification of suspect or found nuclides by type Found Industrial(1) Suspect NORM(1) Found Medical(1) A single keystroke leads to... 18

..Found Nuclides Screens Cs137 TC99m 19

SNM Search Mode 20

The Micro Detective Smaller (-50%) Lighter (-40%)~15lb More Rugged More capabilities Same sensitivity Easier to use STIRLING COOLER Compared to the Detective-EX 21

The Micro Detective 50 mm diameter by 30 mm deep HPGe COAX Wireless control Integral GPS Digital electronics inc LFR noise reduction filter Single 3 He Neutron Detector 22

The Micro Detective-HX One-handed control of instrument through two handle-mounted buttons, or through touch screen. Visual Alarms: LEDs provide clear and simple indication of nuclide type: threat, innocent or suspect, plus error indication. Vibrating alarm built into handle. 3-level auditory alarms can be routed through headphones. 23

The Micro-trans-Spec A Portable HPGe Spectroscopy System Micro-trans-SPEC Applications Nuclear Materials Hold-Up Nuclear Safeguards Inspection In-situ Waste Assay Measurements Emergency Response Reactor Maintenance Medical Physics 24

Detective/TransSpec series Nuclide Identifiers Detective DX Detective EX Detective DX 100 Detective EX 100 Portable Ge Systems TransSpec DX TransSpec DX 100 Micro-TransSpec MicroDetective MicroDetective-HX 25

Detective Customer List United States DOE Laboratories Los Alamos National Laboratory Lawrence Livermore Laboratory Sandia National Laboratory Pacific Northwest Laboratory Idaho National Engineering Laboratory Savannah River National Laboratory United States Customs and Boarder Patrol (CBP) United States Department of Justice -- FBI United States Department of Defense DTRA DISA DIA USAF United States National Guard Civil Support Team Environmental Measurement Laboratory (DHS) Federal Emergency Management Agency (DHS) Radiological Assistance Program (DOE) State of Illinois Emergency Management Agency District of Columbia Bomb Squad District of Columbia Park Police Canada Homeland Security Organization Canada Border Services United Kingdom Ministry of Defense United Kingdom Home Office British Nuclear Fuels, UK IRSN Fontenay aux Roses, France IAEA Austria Fraunhofer Institute Germany DARD Northern Ireland London Fire Brigade 26

Interchangeable Detector Module Large 85 mm x 30 mm HPGe crystal Stirling cycle cooler Hardened cryostat: long life Temperature cycle any time Digitally stable signal processing Hot swap in operational state reduced downtime USB 2.0 data communications Continuous data collection, no dead spots, list mode Low power consumption Low Frequency Rejection filter (LFR) 27

HPGe Detector Assemblies the IDM 28

IDM Applications 29

EASY-MCA-2K/8K Non NIM 2k or 8k MCA USB 2 Interface Fast Conversion (<2-microseconds) Gate Input BUSY and PUR inputs for Dead Time Corrections Includes Maestro-32 (model A65-B32) Software 30

Introducing the DSPEC-LF A powerful Entry Level DSP Ultra-stable digital spectrometer Automatic optimization of detector parameters make setup simple (ORTEC Patented PZ Adjust) ORTEC SMART-1 intelligent HPGe support: display detector status and state-of-health Ballistic deficit correcting digital filter for optimum resolution for large detectors Fast data transfer; live spectrum display via the familiar MAESTRO-32 or other ORTEC software products Easy installation: true plug-and-play on USB 2.0 Full computer control of every function 31

A New Carbon Fiber Endcap for HPGe detectors 32

Detector Construction Major contributor to spectrum counts Mounting cup 33

Transmission (fraction) Low Background Carbon Fiber is: virtually background free As strong as an all Al endcap Can see lower than 10-keV Transmission through Beryllium and Carbon (0.76 mm) 1.2 1.0 Carbon (all) Beryllium (Ultra) 0.8 0.6 Carbon Transmission is 73% of Beryllium 0.4 0.2 0.0 0 5 10 15 20 25 Energy (kev) 34

Industrial Detector -HE option Environmentally Hardened Detector: Impervious to Dust and Grit Sealed Electronics Chamber for Use in High Humidity Environments Splash Proof Corrosion Proof Carbon Fiber Endcap allows use in harsh environment without loss of low energy efficiency 35

Software Developments ISOPLUS 4 for analysis of waste samples ANGLE for analysis of bottles and marinelli beakers Both based on primary point source calibrations -use with any HPGe detector 36

ISO-Plus Version 4.1 Analysis Software for Waste Containers and In-Situ Measurements 37

Six correction factors are calculated Container Matrix Collimator Geometry Self-Attenuation Air 38

ANGLE calibration for bottles and marinelli beakers etc An add-in to GammaVision Takes the GammaVision (traceable) point source calibration and extrapolates to calibration for close object such as Marinelli or Bottle. Same point kernel approach as IsoPlus 39

Questions? 40