SERVICE MANUAL ABC-VW24. Air Purifier. FILE No. Specifications REFERENCE NO. SM

Similar documents
EVAPORATIVE AIR COOLER SERVICE MANUAL

INVERTER ONE-TWO/ONE-THREE/ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

Owner s Manual Super-Slim Four-Way Cassette

Owner s Manual INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC

Owner s Manual INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

DESCRIPTION OF THE APPLIANCE SAFETEY OPERATION CAUTION MAJOR COMPONENTS. Features

Part 3 Troubleshooting

BEFORE OPERATING, READ ALL INSTRUCTIONS IN THIS MANUAL CAREFULLY.

INSTRUCTIONS AND WARRANTY

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*G09LTCN AO*G12LTCN AO*G14LTCN

SPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW1 AOU12RLFW1 ASU 9RLF1 ASU12RLF1 R410A

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOU9RLS2H AOU12RLS2H AOU15RLS2H

CA3500, BA3500, CH3500 New Comfort

SERVICE MANUAL 42QHF009DS* 42QHF012DS* 42QHF018DS* 42QHF022DS* 38QUS009DS* 38QUS012DS* 38QUS018DS* 38QUS022DS* Indoor unit.

WHYNTER Eco Pure Air Purifier

HAKKO 703B REWORK SYSTEM TROUBLESHOOTING GUIDE

Models & Replacement Filter Information

CONTENTS SAFETY PRECAUTIONS. En-1 DANGER! CAUTION!

MULTI-SPLIT SYSTEM AIR CONDITIONER / HEAT PUMP. YN-M Series. Inverter++ Models. Two, Three, Four, and Five Zones (Dual, Triple, Quad, and Quint Multi)

Owners Manual Model: XXL

INSTRUCTION MANUAL EPH-121 CONTENTS

PLEASEREADANDSAVETHESEINSTRUCTIONS. NewAir AC-14000E, AC-14000H Portable Air Conditioner Owner's Manual

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

NEXXOS INVERTER USER MANUAL

FR EN NL DE ES PT IT TR RU UK

IM-H Hand Held Vacuum Cleaner. Instruction Manual Model Ref: H14 / Cat Number: DN909

5) Do not start or stop the unit by inserting or pulling out the power plug.

Coway Air Purifier AP-1008DH

Instruction Manual FEEL THE ENERGY. FEEL THE FRESHNESS.

TECHNICAL INFORMATION T1500 Series Clothes Dryers

Model No.: PS08-01 PS10-01 Ref: KY80 KY100

Installation and Homeowners Guide

Ultrasonic Digital Humidifier

E3M-V. Mark Sensor. Applications

HEPA Air Purifier with Ion Flow Technology

Using the Remote Control Unit

Air Purification System. Instruction Book CLI-AP20

AOYUE 968A+ INT. Deluxe Repairing System INSTRUCTION MANUAL

Moveable Air-conditioner User s Manual

Warning Caution. Safety Precautions (Be sure to read these precautions before using our products.)

Ultrasonic Humidifier TALL. Product Manual

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

KSD-35 DR11 KUE-35 DVN11

Bosch Split-Type Ductless Air Conditioner / Heat Pump

LOCK H M L REPLACE SLEEPING ANTI-POLLEN IONIZER UV-LAMP. User Manual

SERVICE MANUAL ROOM AIR CONDITIONER TAN/TAG-A28FWIS TAN/TAG-A32FWIS CONTENTS

Products documentation (REVISION DATE: 03/10/2011) OMFP6010 (60cm PIROLITIC OVEN)

QD-ENG-68 Controller for Thermoelectric Thermal Management

BIOZONE ICEZONE OWNER'S MANUAL Single Horizontal Evaporator Style Ice Machines BioZone Scientific International

En-2. Fig. 1 Indoor Unit 1 Operating Control Panel (Fig. 2) 2 AIR CLEANER RESET / MANUAL AUTO button

SERVICE MANUAL MSC-GA20VB - (WH) MSC-GA25VB - (WH) MSC-GA35VB - (WH) Wireless type Models

Replacement Filter Information

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*G24LFL AO*G24LFCC AO*G30LFT

Part 5. Troubleshooting. 1. Normal Air Conditioner Phenomenon Air Conditioner Protection in Common

ELECTRONIC AIR PURIFIER

Protect your lung health

USER S MANUAL AQV09V A Series AQV12V A Series AQV18V A Series AQV24V A Series

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

CASSETTE TYPE. AUT Series FUJITSU GENERAL LIMITED AIR CONDITIONER OPERATING MANUAL P/N KEEP THIS MANUAL FOR FUTURE REFERENCE AM PM

SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE

Model & Replacement Pre-Filter Information Model Pre-Filter F Hunter Fan Company

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

OPERATING MANUAL AIR CONDITIONER DUCT TYPE. ART Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

CA-707. Manual. Read these instructions carefully before you start using the dehumidifier and keep the manual for later usage.

Pre-Installation Instructions. Installation Instruction. Installation Instructions. kah. wall. Warning. User s Manual and warranty

PORTABLE AIR CONDITIONER WITH HEATER ... WA-9061 H" 9,000 BTU WA H" 10,000BTU

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513

Air Purifier H201 Air Purifier H301 INSTRUCTION MANUAL

VAL6 EPX. Maintenance Manual

DLFEHA. OWNER S MANUAL High Wall Ductless System Sizes 09 to 24 TABLE OF CONTENTS

HOBOT. HOBOT-168 Glass Cleaning Robot User s Manual

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A

USE & CARE INSTRUCTIONS

AIR PURIFIER CLASSIC INSTRUCTION MANUAL. CAUTION: Read manual carefully for correct procedures and proper operation.

SERVICE MANUAL OUTDOOR UNIT. No. OBH530. Models MU-GE50VB- E1 MUH-GE50VB- E1 HFC SPLIT-TYPE AIR CONDITIONERS R410A

SERVICE MANUAL MSC-GE20VB - E1 MSC-GE25VB - E1 MSC-GE35VB - E1 MS-GE50VB - E1 MSH-GE50VB - E1 INDOOR UNIT. No. OBH529. Models

Surgically Clean Air Inc.

Tornado Operations & Maintenance Manual

1. Safety Precautions Operation Care and cleaning Troubleshooting Specifications... 8

BIOZONE ICEZONE OWNER'S MANUAL Closely Spaced Evaporator Style Ice Machines BioZone Scientific International

Rainsoft Division of Aquion, Inc East Lunt Avenue Elk Grove Village, Illinois or

Coway Air Purifier AP-1008BH/CH

OPERATING MANUAL AIR CONDITIONER CASSETTE TYPE. AUT Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

OPERATING MANUAL COOLING MODEL FUJITSU GENERAL LIMITED ROOM AIR CONDITIONER WALL MOUNTED TYPE. Indoor Unit AST9ASJCW AST12ASJCW

PHOTOCATALYTIC AIR CLEANER

MULTIFUNCTION ROBTIC AUTO VACUUM CLEANER. MODEL NO.: M-788 Auto Charging With Remote Controller, Mop And UV Lamp

SERVICE MANUAL MSZ-GL06NA - U1 MSZ-GL09NA - U1 MSZ-GL12NA - U1 MSZ-GL15NA - U1 MSZ-GL18NA - U1 MSZ-GL24NA - U1

Ultrasonic Cool Mist Humidifier

AC-12200E Portable Air Conditioner

Ultrasonic Humidifier DROP. Product Manual

TECHNICAL SERVICE GUIDE

Lead-Free Repairing System INSTRUCTION MANUAL AIR NOZZLES

Handling or using the product improperly and in disregard of the instructions with this mark might result in serious bodily injury or death.

Table of Contents SAFETY FIRST. Owner s Manual. Safety Precautions Unit Specifications and Features Manual Operation (Without Remote)...

Owner s Manual. Fairwind Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER CS

GMSG OWNER S MANUAL SPLIT-SYSTEM ROOM AIR CONDITIONER CONTENTS

Portable Air Conditioner, Dehumidifier,Heater and Fan utilizing Heat Pump Technology

IM-H12A Hand Held Vacuum Cleaner. Instruction Manual Model Ref: H12 / Cat Number: DN907

Transcription:

SERVICE MANUAL Air Purifier FILE. Specifications HIGH MIDDLE LOW Power source : AC Local voltage 50/60Hz Power consumption : 50 W 16 W 8 W Fan speed : 1,280 r.p.m. 800 r.p.m. 400 r.p.m. Air displacement : 5.1 m 3 /min 2.8 m 3 /min 1.2 m 3 /min ise : 52 db 37 db 18 db Recommend able space : 40 m 2 Filter : Hepa filter & Deodorization filter Dimensions (WxDxH) : 340 x 180 x 600 mm Net weight : 7.1 kg - 1 - REFERENCE NO. SM6510554-00

Wiring Diagram Control circuit C (Switch) CN601 Sensor (Dust) Sensor (Inclination) CN105 Control circuit B (Sensor) CN101 Sensor (Odor/Gas) CN104 CN106 CN501 CN502 Switch (Tank) Electrolyzed terminal CN302 Control circuit A (Power) CN403 Control circuit E (24V-Power) CN405 Control circuit (Ultrasonic unit drive) Ultrasonic unit CN406 CN407 CN404 Electrolyzed water unit CN402 Transformer CN303 Fan motor CN301 AC - 2-

Operation of the Fan Motor Clean Indicator Odor Sensor Dust Sensor The fan motor operates at 5 levels of airflow (revolution speed) as shown in the chart below. In manual operation, use the fan speed button to run the fan at the desired speed low, medium, or high. The airflow display lamps will light up in accordance with the fan speed selected. In automatic operation, the fan operates at low, low medium, medium or high medium in accordance with the situation in the room (cleanliness of the air) depending on the operation of the odor sensor and dust sensor. (When the fan is running automatically, it will not run at high speed.) <te> When the fan is running automatically, the airflow display lamps will not light up. * In older models, when the fan is running automatically, the airflow display lamps light up, but with this model, only the automatic green light lights up and the airflow display lamps do not. (It is not possible to tell at what airflow speed the fan is operating.) Airflow Speed (Operating Status) (Automatic) High High Manual Operation High Automatic Operation Air Cleanliness Clean Sign Airflow Speed Sterilized and Electrolyzed Mist Clean Contamination severe Green Yellow Yellow Red Red High Strong Strong <Motor Protection Function> If the fan is operated at high speed in manual operation with the front cover, pre-filter and filter removed, the revolution speed is dropped slightly for about 1minute and 10 seconds to protect the motor. (If the motor is operated while the filter, etc., is removed, a large burden is placed on the motor (only at times of high speed operation) so the motor protection function starts to work.) - 3-

Automatic Operation Clean Indicator Odor Sensor Automatic(Green) Dust Sensor Even in automatic operation, the odor sensor will not operate soon after the power plug is inserted, but will be inactive for a period of 3 minutes. During this time, the automatic lamp will flash on and off and the fan will operate at low speed. If the automatic lamp changes to being lit up continuously after 3 minutes, the odor sensor will start operation and the fan will run automatically. The dust sensor will begin operation 5 seconds after the power plug is inserted. Even while the automatic lamp is flashing, if the dust sensor detects something, the fan will operate at medium speed. When the fan has been switched over to automatic operation, or when the operation button is pressed on more than 3 minutes after inserting the power plug, the fan motor will operate at low speed for 5 minutes in order to stir the air, even if the air in the room is clean. If the sensors detect something during this period, the fan will operate accordingly. Water electrolyzing and the clean sign will operate at low and green respectively for 5 minutes and then stop (automatic). Airflow During Automatic Operation The equipment includes 2 sensors, a dust sensor and an odor sensor. Each of these sensors operates individually, and outputs commands concerning the force of operational airflow individually. (Refer to the sections on the operation of the individual sensors for details.) The fan will operate at whichever airflow speed is highest in the commands given by the 2 sensors. Even when the clean sign and the sterilized and electrolyzed mist are on (the electrolyzing light is lit), the fan will change speed according to the operational situation. (Refer to the fan motor operation list.) Automatic Operation in Clean Conditions Regular air stirring If the air in the room is clean and the fan is in stop (automatic) status continuously, the fan will operate at low speed for a single period of about 5 minutes every hour in order to stir the air in the room regularly and generate a sterilized and electrolyzed mist. During this time, when the sensors detect that the air in the room is contaminated or that there is dust, or when the operation switch is pressed, the fan will start to run in accordance with the situation. - 4-

Operation of the Dust Sensor Clean Indicator Automatic(Green) Dust Sensor The Operation of the Dust Sensor When the dust sensor detects dust or tobacco smoke in the room, the fan will operate automatically at low or medium speed. When there is a lot of dust, etc., the fan will operate at medium speed, and when there is only a little dust, etc., the fan will operate at low speed. When the air is clean, operation will stop (automatic). (The airflow lamp will not be lit.) When the dust sensor detects something, the operation of the clean sign and sterilized and electrolyzed mist (when the electrolyzed water lamp is lit) will also change in accordance with operational airflow in accordance with the volume of particles of dust, etc., in the air. If the sensor s detection level does not change, the fan will step down following the completion of the operating period for each airflow speed and finally stop (automatic). During this process, if the detection level rises, the fan will operate at the airflow speed for that level. (If the sensor s d etection level does not change, the fan will step down in about 4 minutes.) Even in automatic operation, the dust sensor will not operate soon after the power plug is inserted, but will be inactive for a period of 5 seconds. After that, even while the automatic lamp is flashing, the odor sensor will not operate, but if the dust sensor detects something, the fan will operate at an airflow speed in accordance with the level of dust in the room. When the fan is switched over to automatic operation, it will operate for 5 minutes at low speed even if the air in the room is clean. At this time, the clean sign (green) will be lit. Airflow Speed (Operating Status) (Automatic) High High Air Cleanliness Clean Contamination severe Clean Sign Green Yellow Red Airflow Speed Sterilized and Electrolyzed Mist - 5-

Operation of the Odor Sensor Clean Indicator Automatic(Green) Odor Sensor The Operation of the Odor Sensor When the odor sensor detects contamination of the air, the fan will operate automatically at low, low medium, medium, or high medium speed. When contamination is severe, the fan will operate at high medium speed, and when contamination is slight, the fan will operate at low speed. When the air is clean, operation will stop (automatic). (The airflow lamp will not be lit.) When the odor sensor detects something, the operation of the clean sign and sterilized and electrolyzed mist (when the electrolyzed water lamp is lit) will also change in accordance with operational airflow in accordance with the level of contamination of the air. If the sensor s detection level does not change, the fan will step down following the completion of the operating period for each airflow speed and finally stop (automatic). During this process, if the detection level rises, the fan will operate at the airflow speed for that level. (If the sensor s detection level does not change, the fan will step down in about 2 minutes.) Even in automatic operation, the odor sensor will not operate soon after the power plug is inserted, but will be inactive for a period of 3 minutes. During this time, the automatic lamp will flash on and off and the fan will operate at low speed. When the automatic lamp changes to being lit up continuously after 3 minutes, the odor sensor will start operation and the fan will operate at an airflow level in accordance with the level of contamination of the air. When the fan is switched over to automatic operation, it will operate for 5 minutes at low speed even if the air in the room is clean. At this time, the clean sign (green) will be lit. Airflow Speed (Operating Status) Air Cleanliness (Automatic) Clean High Contamination severe High Clean Sign Green Yellow Yellow Red Red Airflow Speed Sterilized and Electrolyzed Mist High Storng - 6-

Operation of the Sterilized and Electrolyzed Mist The Generation of the Sterilized and Electrolyzed Mist The electrode on the electrolyzing unit is energized to generate electrolyzed water through electrolysis of the tap water in the tank. The electrolyzed water is turned into a nano-sized ultra fine mist using an ultrasonic transducer. This sterilized and electrolyzed mist is then released from the mist outlet into the air, which is stirred around the room by a clean discharge of air. The Operation of the Sterilized and Electrolyzed Mist The operation of the sterilized and electrolyzed mist is controlled by removing the front cover and switching the electrolyzed water button on or off, which enables the choice of whether or not to run the water electrolyzing operation (generation of a sterilized and electrolyzed mist.) While the power mist is operating, the electrolyzed water button is usually on and cannot be turned off. Under either automatic or manual operation, the sterilized and electrolyzed mist operates in accordance with the airflow speed of the fan motor, as shown in the chart below. The ultrasonic transducer is run at high medium or low medium speed and when it is operating, the electrolyzed water lamp (green) and the electrolyzed water lamp (blue) will be lit. When the power mist is operating, the ultrasonic transducer is operated in power mode. (Refer to the chart below.) When the electrolyzing unit and the tank are detached (the tank-attached detection switch will be off), the sterilized and electrolyzed mist will not operate. (The electrolyzed water lamp (green) and the electrolyzed water lamp (blue) will be turned off.) Airflow Speed (Operating Status) (Automatic) High High Manual Operation High Automatic Operation High Sterilized and Electrolyzed Mist Storng Storng Power Mist Operation High High Sterilized and Electrolyzed Mist Power Power Power 0.5 seconds on, 5 seconds off Intermittent operation of ultrasonic transducer Storng 1 second on, 2 seconds off Intermittent operation of ultrasonic transducer Power 1 second on, 1 second off Intermittent operation of ultrasonic transducer - 7-

Operation of the Sterilized and Electrolyzed Mist The Operation of Electrode Power Generation The operation to energize the electrode to create electrolyzed water repeats operation and stopping as shown in the chart below. Operation of Electrolysis Operation (1) Operation (2) Electrolyzing On 4 minute 56 minute 4 minute 56 minute Electrolyzing Off 4 minute 7 hours 56 minutes 4 minute 7 hours 56 minutes In operation (1) and operation (2), the polar character of the electrode is reversed. When the power plug is inserted and the switch first turned on, or when the tank is reset, operation (1) will last 10 minutes the first time it is conducted. Subsequently, the operation/ stop process shown in the chart above will be repeated. The first occasion of power mist operation will last 30 minutes. Subsequently, the operation/ stop process shown in the chart above will be repeated. (During the 30-minute operation on this first occasion, the polar character during the energizing process is positive for 15 minutes and then switched to negative for 15 minutes. Sterilized and Electrolyzed Mist Outlet Add Water Lamp (Red) Upeer Electrolyzed Water Lamp (Green) Front Electrolyzed Water Lamp (Blue) Electrolyzed Water Button <General Indication of the Volume of Sterilized and Electrolyzed Mist Released Manual (High) About 7cc/hr Continuously for about 31 hours Automatic () About 0.5cc/hr Continuously for about 440 hours (about 18 days) *At times of automatic operation, there will be differences in the volume of mist released because each of the sensors will operate according to the situation in the room and the sterilized and electrolyzed mist will be operated in accordance with what the sensors detect. - 8-

Operation of the Sterilized and Electrolyzed Mist <Lamp Display and Status Chart> Electrolyzing Add Water Off On Flashing Off On Flashing Electrolyzing off Tank setting malfunction (tank-attached detection switch off) Electrolyzing on <rmal> When electrolyzing is switched off, the electrode is energized for a 4-minute period once every 8 hours or so for the purpose of purifying the water in the tank. (This is not a malfunction.) *When the equipment is used as normal with electrolyzing on, the processing of the water in the tank makes it sterile, but when electrolyzing is switched off, the water purification process (energizing of the electrode) is run about once every 8 hours in order to avoid neglecting the water in the tank for long periods of time. <rmal> There is no water left in the tank so please fill the tank with water. Operational error in the electrolyzing unit (open) The tank setting status has continued unchanged for 21 days. Please change the water. Operational error in the electrolyzing unit (short circuit) *When the same water is used for a long period of time, concentration becomes very high so please change the water in the tank 21 days after the tank has been filled and attached to the main unit. (When the unit is used normally, the water will run out before 21 days and the light will be lit.) * When the lamp has been lit or is flashing, please wait 15 seconds before resetting the tank. - 9-

Operation of the Power Mist Upeer Power Mist Lamp Front Electrolyzed Water Lamp Front Power Mist Lamp Upeer Electrolyzed Water Lamp Operation when Using the Power Mist In power mist operation, the airflow volume switches automatically as shown in the chart below and after 30 minutes, turns to automatic operation. For operation following this, refer to the section on automatic operation. When the power mist is in operation, the power mist (green) lamp in the operating section on top of the unit and the power mist (blue) lamp on the front of the unit will be lit. (The airflow volume lamp will not be lit.) At this time, the electrolyzed water lamp (green) in the operating section on top of the unit and the electrolyzed water lamp (blue) on the front of the unit should both be lit, and when they are off, there is an attachment error with the electrolyzing unit or the water tank. The sterilized and electrolyzed mist is operated in power mode. (It cannot be selected when electrolyzing is off.) *The sterilized and electrolyzed mist is generated in a repeated 1 second on, 1 second off intermittent operation. Any timer period setting will be deleted when power mist operation is turned on, and it is also not possible to set a timer period during power mist operation. Even during power mist operation, the odor sensor and dust sensor operate individually, and the clean sign is displayed depending on the operation of each sensor. High (5 minutes) High (10 minutes) (15 minutes) Auto matic Operation Time 5 minutes 10 minutes 15 minutes Airflow Speed High High Sterilized and Electrolyzed Mist Power Power Power Power... 1 second on, 1second off - Intermittent operation of ultrasonic transducer - 10-

Manual Operation & Filter Changes Manual Operation The unit can be operated at the airflow speed desired low, medium or high by using the operation mode button. Sterilized and electrolyzed mist operation (when the electrolyzing is on) will operate in accordance with the airflow speed setting. When the speed is set to low or medium, the sterilized and electrolyzed mist will operate at low. When the speed is set to high, the sterilized and electrolyzed mist will operate at power. During manual operation, the set airflow display LED will be lit and the unit will operate at that airflow speed, but the odor sensor and dust sensor will operate clean sign will be displayed in accordance with the operation individually and the of each sensor. *During low speed operation, the clean sign (red) may be lit up. The Operation of the Change Filter Lamp The Change Filter lamp is lit or flashes depending upon the cumulative total of the filter usage period, which is calculated by multiplying the time the motor is operated by coefficients depending on the amount of airflow run through. *When the unit is operated at high, the period of use of the filter will be about 1/10 that when the unit is operated at low, and when the unit is operated at medium, the period of use of the filter will be about 1/5 that when the unit is operated at low. The filter usage period is written onto the IC inside the substrate, and is reset by removing the cover and pressing the filter reset button. When a new filter has replaced an old one, please press the filter reset button to turn off the change filter lamp and clear the filter usage period. The timing of the filter change will differ depending on the operational situation and the installation location, but as a rough guide the filter should last 4 years. For example, if it is supposed that the filter absorbs 5 cigarettes worth of smoke each day, it should last about 4 years. Filter NO. ABC-FAH94A Change Filter (Red) Filter Rest Button - 11-

Problem Diagnosis Chart Will not operate manually *An inclination sensor (S101) is embedded in Control circuit B (sensor) so please conduct operational checks and voltage measurements while the equipment is positioned vertically. Check Is the electricity cable plugged into the mains? Is mains electricity from AC Local voltage 10%? When the unit is switched on, the automatic (green) and clean sign (green) are lit momentarily, but the unit does not operate. Control circnit B (sensor) inclination sensor inspection After about 9 seconds of manual operation, does the unit switch off? Motor cord connection inspection Motor replacement Is there AC100V between the CN301 on Control circuit A (power) Power cord inspection/ replacement Is there voltage of about DC 5V between 8 (+) 9 (-) of CN302 on Control circuit A (power)? Control circuit A (power) inspection/ replacement Is there a display? (Is the airflow speed display lamp lit?) Control circuit C (switch) CN601 connection check Is there voltage of about DC 5V between 8 (+) 9 (-) of CN302 on Control circuit A (power)? Control circnit B (sensor) inspection/ replacement Is there voltage of about DC 15V between white (+) black (-) of motor connector (CN303)? Motor replacement Motor cord connection inspection Control circuit C (switch) CN601 connection check - 12-

Problem Diagnosis Chart Sensors do not detect during automatic operation Will operate manually? Which sensor is not detecting? Dust sensor Will not operate manually Clean Indicator Odor sensor Check Is there anything in the room generating gas? If there is, make it not generate gas. E.g.: Paraffin stove, paint, or cosmetics Reconnect power and switch on automatic operation Shield the dust sensor so that no sunlight or fluorescent light shines directly upon it Odor Sensor Dust Sensor Ventilate the room Reconnect power * Wait until the automatic lamp switches from flashing to lit (about 3 minutes) Insert a needle into the triangular part of the dust sensor and move it lightly Is the sensor working? * Because the dust sensor detects reflected light, insert a pin or office clip that reflects light in the triangular part of the sensor. OK Set sensitivity to high and switch on automatic operation * For automatic operation, refer to The Operation of the Odor Sensor. Release gas Is there about DC 5V between 1 4 of the dust sensor connector (CN1)? Control circuit B (sensor) inspection/ replacement * Use a gas lighter Is the sensor working? Was there any change in the voltage between 1 4 of CN1 when the pin was inserted in the triangular part of the dust sensor and lightly moved? Surveillance sensor inspection/ replacement OK * For automatic operation, refer to The Operation of the Odor Sensor. Control circuit B (sensor) inspection/ replacement - 13-

Problem Diagnosis Chart electrolyzed mist (electrolyzed water) is generated Is the electrolyzed water lamp (blue) on the front panel lit? Is a mist generated intermittently from the sterilized and electrolyzed mist outlet? OK Is the electrolyzing lamp (green) on the top (operation) panel lit? Is at least AC 25V output intermittently to CN405 on Control circuit A (power)? * For the operation of the electrolyzed mist, refer to The Operation of the Sterilized and Electrolyzed Mist Control circuit (ultrasonic unit drive) inspection/ replacement Control circuit C (switch) inspection/replacement Control circuit C (switch) CN60 connection check Control circuit A (power) inspection/ replacement Is the add water lamp (red) flashing? Replace water Electrolyzing unit inspection/ replacement * When the tank has been set in place continuously for 21 days, the concentration of electrolyzed water becomes very high (thick) so please change the water. Is the add water lamp (red) lit? Fill the tank with water Electrolyzing unit inspection/replacement Are the electrolyzing unit and tank definitely attached? Attach the electrolyzing unit and water tank properly Is the micro switch OK? Are the CN106 connections on Control circuit B (sensor) definite? Micro switch replacement Connector connections Power source transformer output Is there at least AC 25V between CN404 red red on Control circuit A (power)? Transformer inspection/replacement Connector connections Control circuit A (power) inspection/ replacement - 14-

Problem Diagnosis Chart Abnormal noise/ large vibration Smoke, rubbish, etc., cannot be removed Is the shape of the fan distorted? Are the prefilter and filter attached properly? Turn the fan by hand Does the fan hit anything? Fan replacement Are the prefilter and filter not dirty? Operate manually Attach the prefilter and filter Prefilter cleaning and filter replacement Remove the fan and turn the shaft Does the shaft turn smoothly? Motor replacement Does the motor turn? Will not operate manually problem Control circuit A (power) replacement or Control circuit B (sensor) replacement * Replacement filter ABC -FAH94A Sensitivity adjustment does not work Reconnect power Sensor sensitivity adjustment Are the knob and odor sensor lever assembled correctly? Assemble the sensor lever and knob correctly Control circuit B(sensor) inspection/replacement - 15-

Replacement Procedure (1) How to Remove the Electrolyzing Unit and Filter 1, Remove the lid and remove the electrolyzing unit. Fig - 1 *If any water is spilt, wipe it up. 2, While pushing in the connection buttons on the left and right of the main unit, remove the front cover by pulling it towards you. Fig - 1 3, Remove the prefilter and filter. Fig - 1 Lid (electrolyzing unit) Tank (assembled) Electrolyzing unit Filter 3, Remove the 2 setscrews on the cord cover in the bottom section and remove the cord cover. Photo - 3 Cord cover 4, Remove the 6 case (back) setscrews and turn the main unit around. Photo - 4 Case (back) setscrews Cord cover setscrews Photo - 3 Connection buttons Front cover Prefilter Fig - 1 (2) How to Remove the Case (Back) 1, Remove the louver L setscrew in the tank section and the 2 setscrews in the front section and remove louver L. Photo - 2 2, Remove the 2 louver R setscrews and remove louver R. Photo - 2 Louver setscrews Photo - 4 5, Remove the case (back) setscrew at the handle and the 3 setscrews at air guide A. Photo 5 6, Lift the bottom section of the case (back) and remove the inset in the top section. Remove the Control circuit C (switch) connection through the gap and then remove the case (back). Photo - 5 Case (back) Case (back) setscrew Air guide A setscrews Louver L (air inlet left) Louver R (air inlet right) Case (back) Photo - 2 Control circuit C (switch) connector Photo - 5-16-

Replacement Procedure (3) Replacing Control Circuit C (Switch) 1, Remove the upper case and switch cover. 2, Remove the 3 Control circuit C (switch) setscrews and remove Control circuit C (switch). Photo - 6 Control circuit C (switch) setscrews Switch cover (5) Replacing the Transformer and Power Cord 1, Remove the holder (power cord) setscrew and remove the Power cord. Photo 7 2, Remove the 2 transformer setscrews and remove the transformer. Photo 7 (6) Replacing the Micro Switch 1, Remove the switch holder setscrew. Photo 9 2, Remove the soldering of the lead wire of the micro switch terminal and remove the micro switch. Photo - 9 Back cover Photo - 6 (4) Replacing Control Circuit A (Power) 1, Remove the 2 unit case setscrews and remove the unit case. Photo - 7 Transformer Unit case Switch holder setscrew Micro switch Transformer setscrews Power cord Unit case setscrews Photo - 7 2, Remove all of the connectors connected to Control circuit A (power). Photo 8 3, Remove the 3 Control circuit A (power) setscrews and remove Control circuit A (power). Photo - 8 Control circuit A (power) setscrews Holder setscrew Holder Photo - 9 (7) Replacing the Control Circuit (Ultrasonic Unit Drive) 1, Remove the inset of the air guide A nail and remove the shield case from air guide A. Photo 10 2, Remove the 2 Control circuit (ultrasonic unit drive) setscrews. Photo 10 3, Remove the soldering of the lead wire of the Control circuit (ultrasonic unit drive) terminal and remove the Control circuit (ultrasonic unit drive). Photo - 10 Control circuit (ultrasonic unit drive) setscrews Shield case Air guide A Control circuit A (power ) Photo - 8 Control circuit (ultrasonic unit drive) Photo - 10-17-

Replacement Procedure (8) Replacing Control Circuit B (Sensor) 1, Remove the 2 air guide A setscrews and remove air guide A. Photo -11 Substrate B (sensor) Air guide A (10) Replacing the Fan Motor 1, Remove the fan retaining nut and remove washers A and B, and the fan lock piece. Photo 13 2, Pull the fan off the motor shaft. Photo - 13 Fan retaining nut Photo - 11 2, Remove the 2 insulator P setscrews and remove insulator P. Photo 12 3, Remove the 2 Control circuit B setscrews and remove Control circuit B (sensor). Photo 12 4, Remove all of the Control circuit B (sensor) connectors. Photo 12 Dust sensor setscrew Air guide A setscrews Control circuit B setscrews Washers A and B Fan lock piece Photo - 13 3, Remove the cord cover and take out the motor cord. Photo 14 4, Pull washer C off the motor shaft. 5, Remove the 3 motor retainer setscrews and remove the fan motor. Photo - 14 Motor retainer setscrews Cord cover Fan Dust sensor Control circuit B (display) Insulator P Insulator P setscrews Motor retainer Photo - 12 (9) Replacing the Dust Sensor 1, Remove the dust sensor setscrew and remove the dust sensor. Photo - 12 Fan motor Photo - 14 Jul./2007 Printed in Japan - 18- SANYO Electric Co.,Ltd Osaka, Japan