TECHNICAL CATALOGUE SELF-CONTAINED VERTICAL UNITS AIR / AIR DC INVERTER

Similar documents
ROOF TOP TYPE UNITS CENTRIFUGAL FANS ENGINEERING DATA MANUAL MODELS Rev. 100

CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

ECV SP GUE ALO CAT ICAL TECHN

EHW KH PF HIGH EFFICIENTY AIR CONDITONING UNITS TECHNICAL CATALOGUE

SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER)

CONDENSING UNITS AIR COOLED CONDENSER. COOLING ONLY

BHW INSTALLATION, OPERATION AND MAINTENANCE MANUAL MEDIUM STATIC PRESSURE DUCTABLE TYPE. Models:

EQEF TECHNICAL CATALOGUE AIR COOLED WATER CHILLERS AXIAL FANS WITH FREE-COOLING SYSTEM

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

50A KP 70A KP 90A KP 120A KP 150A KP 210A

E U R O V E N T CERTIFIED PERFORMANCE

Chiller units and air-water heat pumps RANGE OPERATING LIMITS

EQSL TECHNICAL CATALOGUE AIR COOLED WATER CHILLER UNITS AXIAL FANS. Models: 300 V2 F V2 F16. Cooling capacity: 299 to 1310 KW

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating.

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

Application guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort

EQUH PF PACKAGED HEAT PUMP AIR/ WATER LIQUID CHILLER FOR INDOOR INSTALLATION

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

HYDRONIC SYSTEMS WHY CHOOSING BETWEEN ENERGY EFFICIENCY AND ROBUSTNESS?

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

CHAPTER 6 CONDENSING UNITS

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

Highly Efficient,Powerful Heating and Cooling.

Galletti Water chillers and heat pumps catalogue

recooler HP EQKR HEAT PUMP

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

Blue Box Epsilon Echos +

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

Packaged air conditioning unit condensed by air model RTC 07L to 30L. Technical information. Ref.: Y-R

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

Packaged air conditioning unit condensed by air model RTC 07L to 30L. Technical information. Ref.: N

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

PRODUCT RANGE: ROOFTOP PACKAGE

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

CCHA / ECHA Cooling Only CCHBA / ECHBA Heat Pump

ERAH MC Ka. Range kw. AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS FOR OUTDOOR INSTALLATION (Standard line)

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

HRV-IP. Ceiling Type Heat Pump Heat Recovery Unit


Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

NEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

Compact Horizontal Air-Air Heat Pump Model RTH 07L to 30L. Technical information. Ref.: N

EQPHU PACKAGED HEAT PUMP AIR/ WATER LIQUID CHILLER FOR OUTDOOR INSTALLATION

R4H4. Product Specifications

Advance Split

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

LZT High efficiency air to water heat pumps with E.V.I. compressors

next p dw next p dw rcgroupairconditioning

Aquair BCP. Pool air handling units. Electronic Control Optimized energy consumption DESCRIPTION PRINCIPLE SCHEMES RANGE OPERATING LIMITS

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

E U R O V E N T CERTIFIED PERFORMANCE

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

LZA High efficiency air to water heat pumps with HP compressor

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

R4H4. Product Specifications

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP

PRODUCT GUIDE

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

Personalized comfort for offices and shopping malls RANGE OPERATING LIMITS

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

SECTION WATER-SOURCE UNITARY HEAT PUMPS

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

BETA ECHOS. Air/water cooled chillers and heat pumps kw. General BETA ECHOS is a range of chillers and ductable air-water heat pumps.

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES

TVR 5G GUIDE SPECS. TVR 5G GUIDE SPECS - JUL.2014 Page 1

AHU Plus. DX Air Handling Units

50VZ (40PZ/38VZ) Vertical Air-Cooled Split-System Cooling Units. Nominal cooling capacity kw

CoolTeg Plus XC40. AC-TXC Direct expansion Air-conditioning unit with integrated compressor

Air cooled industrial chillers

INVERTER SCROLL. LG Electronics Distributed by. Copyright 2017 LG Electronics. All rights reserved.

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

HCompact2 HA. Compact air-air stand-alone units. Compact horizontal Reduced dimensions Centrifugal fans RANGE DESCRIPTION OPERATING LIMITS SERIES

Compact design & easy maintenance

CENTRAL SPLIT UNIT UNIC

OCTOPLUS VWF SYSTEM General Catalogue

SPLIT System. SPLIT System Simple and flexible direct expansion solutions for the commercial sector and industry

APPLICATION GUIDE FLATAIR FMC - H FIC - H FSC - H. Horizontal packaged air conditioners kw FLATAIR AGU-MSL E. lennoxemeia.

ROOFTOP PACKAGED AIR CONDITIONERS

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

ReCooler Heat-Pump Energy efficient cooling unit for eq Air Handling Unit

Transcription:

TECHNICAL CATALOGUE SELF-CONTAINED VERTICAL UNITS AIR / AIR DC INVERTER Models : 601, 741, 901 ACVIA - Cooling only (Compact) CCVIA / ECVIA - Cooling only (Split) ACVIBA - Heat Pump (Compact) CCVIBA / ECVIBA - Heat Pump (Split) 12.16 Ref.207378 Rev.102

Thank you for trust in HITECSA Product. From our company we are offering to the market, for more than 30 years, an extended range of specialized units for air conditioning and cooling installations. Our approach is based in efficiency, flexibility, manageability and practical solutions. It has built a hallmark of our product catalogue. The versatility of our factories allows us to contribute solutions almost customitzables in each project, searching a solution for every problem that arises in design and implementation of air conditioning installations. From Hiplus Aire Acondicionado s team, once more thank you very much. 2 de 24 12.16 Ref.207378 Rev.102

SUMMARY PAGE KEY POINTS AND PRESENTATION 4 GENERAL SPECIFICATIONS 5 REFRIGERATOR DIAGRAMS 7 TECHNICAL DATA 9 DIMENSIONS 13 AIRFLOW AND STATIC PRESSURE (EVAPORATOR side) 19 AIRFLOW AND STATIC PRESSURE (CONDENSER side) 21 REMOTE CONTROL AND OPTIONALS 23 Visit our web page and sign in to obtain technical documentation of this units and the rest of Hitecsa product range www.hitecsa.com 3 de 24 12.16 Ref.207378 Rev.102

KEY POINTS - Optimized design for an easy access to the components - Exchangeable covers for configure in action supply and return air - DC inverter technology: maximum safe and comfort máximo ahorro y confort - Cooling capacities from 4 until 28 kw - Maximum adaptability to request - Low sound level - High performance in heat pump mode for low outdoor temperatures PRESENTATION - Air-air self-contained range has been checked and optimised to adapt itself the current demand of energy efficiency and environment protection. The introduction of ecological gas R410A, DC inverter technology, available extension of cooling capacities and the optionals long list are some examples of the units improvements. - DC inverter technology adapt the compressor speed to needs at every moment, allowing only the necessary energy consuming and drastically reduce consumption. 4 de 24 12.16 Ref.207378 Rev.102

CARACTERÍSTICAS GENERALES DESCRIPCIÓN The equiment constitute fot series CCVIA/ECVIA - CCVIBA/ECVIBA are vertical air conditioner in split contruction being the first cooling only and the second one made with heat pump. In parallel and compact contruction ACVIA-ACVIBA are available, they are also for cooling only and heat pump versions. All these equipments are suitable to work connected in a net of air distribution pipe as much in indoor section as in outdoor section. CABINET Made in galvanized steel plate, completed with polyester resins, polymerized in the oven, excellent resistance to corrosion and in outdoors. The assembly is wrapped with thermoacustic insulation. COMPRESSORS scroll. motor: BLDC. Number of poles: 6 Supply: Triphase Brushlessmotor is formed for a stator and a rotor with permanent magneto. It shows a higher efficiency respect to induction motors because no exist magnetizing current losses in the rotor. EXCHANGERS Built in aluminum fins (fin step 2,1 mm) and copper pipe mechanically expanded of 3/8", high exchange efficiency. EXPANSION DEVICE As much in compact models as divide models are equipped with Electronic Expnsion Valves. In compact models is mounted only one Expansion Valve while divide models incorporate one for each section. For divide models, altought their assembly is formed for two Electronic Expansion Valves only regulates only for section whose exchanger is evaporating, remaining fully open the other valve. AIR FILTER Polyurethane foam, washable, 10 mm thick crosslinked S-20 with high efficiency filtration FANS Centrifuge type. Supply by frecuency converter Changeable airflow in condenser. Three kind of airflows in evaporator (low, medium and maximum speed. Possivility in Evaporator of increase or reduce Diponible Pressure. COOLING CIRCUIT - Built in special copper tube for refrigeration, dehydrated, incorporating drying filter and check valve with an easy acces for verification and charge. - Equip suction accumulator on the compressor suction line, protect it from liquid bumps - In split models, oil separator is included - Reversing Valve to cycle invertion by solenoid (230V) in Heat Pump models. - Unidirectional Valves - The welds between the different elements are executed with copper-silver alloy. 5 de 24 12.16 Ref.207378 Rev.102

GENERAL SPECIFICATIONS MANEUVER AND CONTROL EQUIPMENT Each unit is available of control and safety devices of shown below: - Environment thermostat to 230 Volts AC. monophase - Protection magnetothermals for compressor, fans and general maneuver - Thermal protection of all triphase motors. - Speed regulator for fan motor of outdoor side (as much Cooling as Heat Pump) - High Pressure Presostat - System defrost pressure control performance according to predetermined time periods. - Reversible valve activated by solenoid to 230V - Remote connection ON-OFF and COOL-HEAT. - ALARM indication. OPTIONALS - Heating coil for electrical heating as single support in defrost maneuver. - Hot water heating coil. - Anti-corrosion pre-treated coils. Treatment blue fin. - Compressor sound jacket - Free-cooling. Damper system activated by servomotor to use outdoor conditions as climatization mode for indoor section. - Outdoor installation kit. - Anti-freeze resistance operation collection in tray - High efficiency filters G4 and F6-F8 - Upgraded motor. Available pressure increase in condenser and evaporator section - Air filter in condenser - Schrader Valves for pressure test - Scheduling function and Modbus connection POWER SUPPLY Thermostat: 230.I.50 Hz~ 601, 741 and 901 models: 401.III+N.50Hz ~. For other supplies consult availability OPERATION LIMITS COOLING CICLE Outdoor air temperature Indoor air temperature Dry Wet Dry Wet Standard conditions 35ºC - 27ºC 19ºC Minimum conditions 20ºC - 20ºC 15ºC Maximum conditions 48ºC - 32ºC 23ºC HEATING CICLE Outdoor air temperature Indoor air temperature Dry Wet Dry Wet Standard conditions 7ºC 6ºC 20ºC - Minimum conditions - 12ºC - 13ºC 20ºC - Maximum conditions 24ºC 18ºC 26ºC - 6 de 24 12.16 Ref.207378 Rev.102

REFRIGERATOR DIAGRAMS REFRIGERATOR DIAGRAM (COMPACT) 1. Four-way reverse cycle valve 2. Outdoor fan 3. Check valve 4. Filter 5. Expansion valve 6. Suction acumulator 7. Ball valve 8. Compressor TE Outdoor air temperature TI Indoor air temperature B1 Discharge temperature B6 Suction pressure B7 Discharge pressure B4 Reheating temperature 7 de 24 12.16 Ref.207378 Rev.102

REFRIGERATOR DIAGRAMS REFRIGERATOR DIAGRAM (SPLIT) 1. Four-way reverse cycle valve 2. Outdoor fan 3. Expansion valve 4. Check valve 5. Filter 6. Service key 7. Suction acumulator 8. Compressor 9. Service valve 10. Silencer 11. Oil separator TE Outdoor air temperature TI Indoor air temperature B1 Discharge temperature B6 Suction pressure B7 Discharge pressure B4 Reheating temperature 8 de 24 12.16 Ref.207378 Rev.102

TECHNICAL DATA ACVIA - ACVIBA 601 741 901 CAPACITIES Cooling capacity (20-80 - 120 Hz) kw 4,0-13,8-18,5 5,2-17,7-23,9 6,5-22,0-28,3 Heating capacity (20-80 - 120 Hz) kw 4,2-13,9-19,8 4,5-17,8-25,8 7,0-22,2-30,2 EER (40-80 - 90 Hz) 2.90-2.60-2.50 2.86-2.56-2.45 2.96-2.54-2.44 COP (40-80 - 90 Hz) 2.95-2.62-2.52 2.94-2.69-2.55 2.99-2.64-2.54 Number of refrigerant circuits 1 1 1 REFRIGERANT R-410A Global warming potential 1725 Baseload Kg 6,5 7,5 9,5 COMPRESSOR SCROLL DC INVERTER Number 1 1 1 Oil type FV50S (PVE) FV50S (PVE) FV50S (PVE) Oil volume l 1,4 1,7 2,3 OUTDOOR EXCHANGER Aluminium fins and copper tubing Frontal surface m 2 0,711 0,711 1,112 Space fin mm 2,1 2,1 2,1 Piping diameter " 3/8 3/8 3/8 OUTDOOR FAN DOUBLE SUCTION CENTRIFUGAL Model 15/15 SS 15/15 SS 15/11 G2L Voltage V 400/3/50 400/3/50 400/3/50 Motor capacity kw 1,1 1,5 2,2 Transmission speed Pulleys Pulleys Pulleys Nominal air flow m 3 /h 6.800 7.300 10.000 Available static pressure Pa 50 50 50 Maximum fan speed r.p.m. 740 830 688 INDOOR EXCHANGER Aluminium fins and copper tubing Frontal surface m 2 0,540 0,540 0,738 Space fin mm 2,1 2,1 2,1 Piping diameter " 3/8 3/8 3/8 INDOOR FAN DOUBLE SUCTION CENTRIFUGAL Model 12/12 SS 12/12 SS 12/12 G2L Voltage V 400/3/50 400/3/50 400/3/50 Motor capacity kw 0,75 1,1 1,1 Transmission speed Pulleys Pulleys Pulleys Air flows (Low / Medium / High) m 3 /h 2.700/3.200/4.000 3.200/3.800/4.800 3.900/4.650/5.900 Available static pressure Higher flow Pa 70 75 90 Maximum fan speed r.p.m. 760 906 806 9 de 24 12.16 Ref.207378 Rev.102

TECHNICAL DATA ACVIA - ACVIBA 601 741 901 NOMINAL ELECTRICAL SPECIFICATIONS FOR STANDARD CONDITIONS Power supply V 400/3/50 + N Power input (Cooling only) kw 5,4 6,9 8,6 Current input (Cooling only) A 8,6 11,0 14,5 Power input (Heating) kw 4,9 6,3 8,4 Current input (Heating) A 8,3 11,0 13,5 Maximum Power Input (Cooling only) kw 9,2 12,0 14,9 Maximum Current Input (Cooling only) A 15,0 19,0 25,4 Maximum Power Input (Heating) kw 8,7 11,3 14,3 Maximum Current Input (Heating) A 14,3 18,5 23,5 NOMINAL ELECTRICAL SPECIFICATIONS FOR COOLING STANDARD CONDITIONS (1) Power Supply V 400/3/50 + N Power input (Cooling only) kw 5,4 6,9 8,6 Current input (Cooling only) A 8,6 11,0 14,5 Indoor airflow m 3 /h 2.700 3.200 3.900 NOMINAL ELECTRICAL SPECIFICATIONS FOR HEATING STANDARD CONDITIONS (2) Power Supply V 400/3/50 + N Power input (Heating) kw 4,9 6,3 8,4 Current input (Heating) A 8,3 11,0 13,5 Indoor airflow m 3 /h 3.200 3.800 4.650 MAXIMUM ELECTRICAL SPECIFICATIONS FOR COOLING STANDARD CONDITIONS (3) Power Supply V 400/3/50 + N Power input (Cooling only) kw 9,2 12,0 14,9 Current input (Cooling only) A 15,0 19,0 25,4 Indoor airflow m 3 /h 3.200 3.800 4.650 MAXIMUM ELECTRICAL SPECIFICATIONS FOR HEATING STANDARD CONDITIONS (4) Power Supply V 400/3/50 + N Power input (Heating) kw 8,7 11,3 14,3 Current input (Heating) A 14,3 18,5 23,5 Indoor airflow m 3 /h 4.000 4.800 5.900 (1) Cooling: Compressor frecuency: 80Hz. Outdoor dry temperature: 35 C. Indoor Dry / Wet air temperature: 27ºC / 19 C. Indoor airflow: Low. (2) Heating: Compressor frecuency: 80Hz. Outdoor dry /wet airtemperature: 7ºC / 6 C. Indoor dry temperature: 20 C. Indoor airflow: Medium. (3) Cooling maximum: Compressor frecuency: 120Hz. Outdoor dry temperature: 35 C. Indoor Dry / Wet air temperature: 27ºC / 19 C. Indoor airflow: Medium (4) Heating maximum: Compressor frecuency: 120Hz. Outdoor dry /wet airtemperature: 7ºC / 6 C. Indoor dry temperature: 20 C. Indoor airflow: High 10 de 24 12.16 Ref.207378 Rev.102

TECHNICAL DATA CCVIA - CCVIBA 601 741 901 CAPACITIES Cooling capacity (20-80 - 120 Hz) kw 4,0-13,8-18,5 5,2-17,7-23,9 6,5-22,0-28,3 Heating capacity (20-80 - 120 Hz) kw 4,2-13,9-19,8 4,5-17,8-25,8 7,0-22,2-30,2 EER (40-80 - 90 Hz) 2.90-2.60-2.50 2.86-2.56-2.45 2.96-2.54-2.44 COP (40-80 - 90 Hz) 2.95-2.62-2.52 2.94-2.69-2.55 2.99-2.64-2.54 Number of refrigerant circuits 1 1 1 REFRIGERANT R-410A Global warming potential 1725 Cooling liquid connection " 1/2 5/8 5/8 Cooling gas connection " 7/8 1 1/8 1 1/8 Base load Kg 6,5 7,5 9,5 COMPRESSOR SCROLL DC INVERTER Number 1,000 1 1 Oil type FV50S (PVE) FV50S (PVE) FV50S (PVE) Oil volume l 1,4 1,7 2,3 OUTDOOR EXCHANGER Aluminium fins and copper tubing Frontal surface 2 m 0,711 0,711 1,112 Space fin mm 2,1 2,1 2,1 Piping diameter " 3/8 3/8 3/8 OUTDOOR FAN DOUBLE SUCTION CENTRIFUGAL Model 15/15 SS 15/15 SS 15/11 G2L Voltage V 400/3/50 400/3/50 400/3/50 Motor capacity kw 1,1 1,5 2,2 Transmission speed Poleas Poleas Poleas Nominal air flow m 3 /h 6.800 7.300 10.000 Available static pressure Pa 50 50 50 Maximum fan speed r.p.m. 740 830 688 NOMINAL ELECTRICAL SPECIFICATIONS FOR COOLING STANDARD CONDITIONS (1) Power Supply V 400/3/50 + N Power input (Cooling only) kw 4,9 6,3 7,9 Current input (Cooling only) A 7,9 10,1 13,4 Indoor airflow m 3 /h 2.700 3.200 3.900 NOMINAL ELECTRICAL SPECIFICATIONS FOR HEATING STANDARD CONDITIONS (2) Power Supply V 400/3/50 + N Power input (Heating) kw 4,3 5,6 7,4 Current input (Heating) A 7,3 9,8 11,9 Indoor airflow m 3 /h 3.200 3.800 4.650 MAXIMUM ELECTRICAL SPECIFICATIONS FOR COOLING STANDARD CONDITIONS (3) Power Supply V 400/3/50 + N Power input (Cooling only) kw 8,6 11,3 13,9 Current input (Cooling only) A 14,1 17,9 23,7 Indoor airflow m 3 /h 3.200 3.800 4.650 MAXIMUM ELECTRICAL SPECIFICATIONS FOR HEATING STANDARD CONDITIONS (4) Power Supply 400/3/50 + N Power input (Heating) kw 7,4 9,8 12,6 Current input (Heating) A 12,2 16,1 20,8 Indoor airflow m 3 /h 4.000 4.800 5.900 DIMENSIONS AND WEIGHT Lenght mm 1130 1130 1700 Width mm 800 800 870 Height mm 1250 1250 1250 Weight Kg 260 320 390 (1) Cooling: Compressor frecuency: 80Hz. Outdoor dry temperature: 35 C. Indoor Dry / Wet air temperature: 27ºC / 19 C. Indoor airflow: Low. (2) Heating: Compressor frecuency: 80Hz. Outdoor dry /wet airtemperature: 7ºC / 6 C. Indoor dry temperature: 20 C. Indoor airflow: Medium. (3) Cooling maximum: Compressor frecuency: 120Hz. Outdoor dry temperature: 35 C. Indoor Dry / Wet air temperature: 27ºC / 19 C. Indoor airflow: Medium (4) Heating maximum: Compressor frecuency: 120Hz. Outdoor dry /wet airtemperature: 7ºC / 6 C. Indoor dry temperature: 20 C. Indoor airflow: High 11 de 24 12.16 Ref.207378 Rev.102

TECHNICAL DATA ECVIA - ECVIBA ECVIA STD ECVIBA STD 601 741 901 CAPACITIES Cooling capacity (20-80 - 120 Hz) kw 4,0-13,8-18,5 5,2-17,7-23,9 6,5-22,0-28,3 Heating capacity (20-80 - 120 Hz) kw 4,2-13,9-19,8 4,5-17,8-25,8 7,0-22,2-30,2 EER (40-80 - 90 Hz) 2.90-2.60-2.50 2.86-2.56-2.45 2.96-2.54-2.44 COP (40-80 - 90 Hz) 2.95-2.62-2.52 2.94-2.69-2.55 2.99-2.64-2.54 Number of refrigerant circuits 1 1 1 REFRIGERANT R-410A Global warming potential 1725 Cooling liquid connection " 1/2 5/8 5/8 Cooling gas connection " 7/8 1 1/8 1 1/8 INDOOR EXCHANGER Aluminium fins and copper tubing Frontal Surface m 2 0,540 0,540 0,738 Space fin mm 2,1 2,1 2,1 Piping Diameter " 3/8 3/8 3/8 INDOOR FAN DOUBLE SUCTION CENTRIFUGAL Model 12/12 SS 12/12 SS 12/12 G2L Voltage V 400/3/50 400/3/50 400/3/50 Motor capacity kw 0,75 1,1 1,1 Transmission speed Pulleys Pulleys Pulleys Air flows (Low / Medium / High) m 3 /h 2.700/3.200/4.000 3.200/3.800/4.800 3.900/4.650/5.900 Available static pressure Higher flow Pa 70 75 90 Maximum fan speed r.p.m. 760 906 806 NOMINAL ELECTRICAL SPECIFICATIONS FOR COOLING STANDARD CONDITIONS (1) Power Supply V 400/3/50 + N Power input (Cooling only) kw 0,5 0,6 0,7 Current input (Cooling only) A 1,0 1,2 1,6 Indoor airflow m 3 /h 2.700 3.200 3.900 NOMINAL ELECTRICAL SPECIFICATIONS FOR HEATING STANDARD CONDITIONS (2) Power Supply V 400/3/50 + N Power input (Heating) kw 0,6 0,7 1,0 Current input (Heating) A 1,2 1,6 2,3 Indoor airflow m 3 /h 3.200 3.800 4.650 MAXIMUM ELECTRICAL SPECIFICATIONS FOR COOLING STANDARD CONDITIONS (3) Power Supply V 400/3/50 + N Power input (Cooling only) kw 0,6 0,7 1,0 Current input (Cooling only) A 1,2 1,5 2,3 Indoor airflow m 3 /h 3.200 3.800 4.650 MAXIMUM ELECTRICAL SPECIFICATIONS FOR HEATING STANDARD CONDITIONS (4) Power Supply 400/3/50 + N Power input (Heating) kw 1,3 1,5 1,7 Current input (Heating) A 2,0 2,4 2,8 Indoor airflow m 3 /h 4.000 4.800 5.900 DIMENSIONS AND WEIGHT Lenght mm 1130 1130 1700 Width mm 800 800 870 Height mm 650 650 650 Weight Kg 140 150 210 (1) Cooling: Compressor frecuency: 80Hz. Outdoor dry temperature: 35 C. Indoor Dry / Wet air temperature: 27ºC / 19 C. Indoor airflow: Low. (2) Heating: Compressor frecuency: 80Hz. Outdoor dry /wet airtemperature: 7ºC / 6 C. Indoor dry temperature: 20 C. Indoor airflow: Medium. (3) Cooling maximum: Compressor frecuency: 120Hz. Outdoor dry temperature: 35 C. Indoor Dry / Wet air temperature: 27ºC / 19 C. Indoor airflow: Medium (4) Heating maximum: Compressor frecuency: 120Hz. Outdoor dry /wet airtemperature: 7ºC / 6 C. Indoor dry temperature: 20 C. Indoor airflow: High 12 de 24 12.16 Ref.207378 Rev.102

DIMENSIONS ACVIA-ACVIBA 601-741 13 de 24 12.16 Ref.207378 Rev.102 CONSTRUCTION DETAILS 1. AIR FILTER 2. CONDENSER COIL 3. CONDENTSER TURBINE 4. CONDENSER TURBINE MOTOR 5. COMPRESSOR 6. POWER SUPPLY INPUT 7. EVAPORATOR COIL 8. ELECTRICAL PANEL 9. EVAPORATOR TURBINE MOTOR 10. EVAPORATOR TURBINE 11. DRAINAGE 3/4"

DIMENSIONS ACVIA-ACVIBA 901 14 de 24 12.16 Ref.207378 Rev.102 CONSTRUCTION DETAILS 1. AIR FILTER 2. CONDENSER COIL 3. CONDENSER TURBINE 4. CONDENSER TURBINE MOTOR 5. COMPRESSOR 6. POWER SUPPLY INPUT 7. EVAPORATOR COIL 8. ELECTRICAL PANEL 9. EVPORATOR TURBINE MOTOR 10. EVAPORATOR TURBINE 11. DRAINAGE 3/4"

DIMENSIONS ECVIA-ECVIBA 601-741 15 de 24 12.16 Ref.207378 Rev.102

DIMENSIONS ECVIA-ECVIBA 901 16 de 24 12.16 Ref.207378 Rev.102

DIMENSIONS CCVIA-CCVIBA 601-741 17 de 24 12.16 Ref.207378 Rev.102

DIMENSIONS CCVIA - CCVIBA 901 18 de 24 12.16 Ref.207378 Rev.102 CONSTRUCTION DETAILS 1. CONDENSER TURBINE 2. CONDENSER TURBINE MOTOR 3. CONDENSER COIL 4. COMPRESSOR 5. POWER SUPPLY INPUT 6. DRAINAGE 3/4" 7. ELECTRICAL PANEL 8. MAIN ON-OFF SWITCH

AIRFLOW AND STATIC PRESSURE (EVAPORATOR SIDE) ECVIBA 601 Nominal Flow High Medium Low 100 90 80 Available pressure (Pa) Available Pressure (Pa) 70 60 50 40 30 20 10 120 110 100 90 80 70 60 50 40 0 2000 2200 2400 2600 2800 3000 3200 3400 3600 3800 4000 4200 4400 Air flow (m3/h) ECVIBA 741 Nominal Flow High Medium Low 30 20 10 0 2600 2800 3000 3200 3400 3600 3800 4000 4200 4400 4600 4800 5000 Air flow (m3/h) 19 de 24 12.16 Ref.207378 Rev.102

AIRFLOW AND STATIC PRESSURE (EVAPORATOR SIDE) 120 110 100 90 ECVIBA 901 Nominal flow High Medium Low Available pressure (Pa) 80 70 60 50 40 30 20 10 0 3400 3600 3800 4000 4200 4400 4600 4800 5000 5200 5400 5600 5800 6000 6200 Airflow (m3/h) 29 de 24 12.16 Ref.207378 Rev.102

AIRFLOWS AND STATIC PRESSURE (CONDENSER SIDE) 160 CCVIBA 601 Nominal Airflow 100% 70% 140 Available Pressure (Pa) 120 100 80 60 40 20 0 3500 4000 4500 5000 5500 6000 6500 7000 7500 8000 Air flow (m3/h) CCVIBA 741 Nominal flow 100% 70% 180 160 140 Available Pressure (Pa) 120 100 80 60 40 20 0 3600 4100 4600 5100 5600 6100 6600 7100 7600 8100 8600 9100 9600 Air flow (m3/h) 21 de 24 12.16 Ref.207378 Rev.102

AIRFLOWS AND STATIC PRESSURE (CONDENSER SIDE) 140 CCVIBA 901 Nominal Flow 100% 70% 120 Available Pressure (Pa) 100 80 60 40 20 0 3600 4600 5600 6600 7600 8600 9600 10600 11600 Air flow (m3/h) 22 de 24 12.16 Ref.207378 Rev.102

REMOTE CONTROL DC inverter self-contained range (compact and split) uses TH Tune remoted control. In this control is displayed: - Cooling / Heating mode - Temperature control (environmental / return) - Outdoor temperature By icons, we can see the compressor and outdoor fan operation. Indoor fan speed (high, medium or low) can be fixed for the user although is recommended set in automatic mode. In case of alarm or maintenance, this control informs us through codes of action to follow. OPTIONALS WALL PROBE If you prefer control temperature with environmental probe, is recommended use DPWT01100 wall probe. This optional allows control indoor stable tem perature, so records a tempe rature value in zone control. Generally it is advisable to install a close apposition to where the Tune TH control is mounted. ELECTRIC RESISTANCE COIL FOR AUXILIARY ELECTRICAL HEATING DURING DEFROST These coils are formed for finned elements mounted in steel plate frame. They incorporate protector thermostat, actuating contactors and terminal strip for wiring. Mounted in suction. Model 601 741 901 Capacity kw 6 9 6 9 12 9 12 15 Voltage V 400/3/50 Current Input A 9 13 9 13 17 13 17 22 Consult for other capacities. FREE COOLING Consult. 23 de 24 12.16 Ref.207378 Rev.102

Masia Torrents, 2 08800 Vilanova i la Geltrú (Barcelona) España Tel. 93 893 49 12 Fax. 93 893 96 15 info@hitecsa.com www.hitecsa.com 12.16 Ref.207378 Reserved the right to make changes without previous notice.