TP970 SERIES ASPIRATING WALL BOX ASSEMBLIES BEFORE INSTALLATION

Similar documents
TP970 Series CONVERTASTAT Kits

HP970 and TP970 Series Standard Covers and Accessories

TP970-72, TP970-74, TP9600, and TP9630 Pneumatic Sensors, Humidistats, and Thermostats INSTALLATION INSTRUCTIONS

HP970A, B and HP972B Pneumatic Humidistats

T7200D,E Series 2000 Commercial Microelectronic Thermostats

TK-1801, TK-1811 TK-1801, TKR-1811

T6984F,G Electronic Floating Control Thermostats

Powers TM Controls Accessories for Installing TH 192, TH 194 or Free Energy Band TH 193 HC Room Thermostats

T4031A,B,P; T6031A,B Refrigeration Temperature Controllers

T4398A,B High Performance Electric Heat Thermostats

T8190A/191108AJ Heating or Cooling Thermostat/Wallplate; T8190A/Q682B Heating/Cooling Thermostat/Subbase

T4098A,B Deluxe Electric Heat Thermostats

T7350 Programmable Thermostat FOR CONVENTIONAL/HEAT PUMP SYSTEMS

C7232A,B Sensor and Controller

HE120, HE160 Humidifier Installation Kit

HE360 Humidifier Installation Kit

Retrostat Kits for Johnson Controls D/N or H/C Thermostats

Solid Core and Split Core 4-20 ma Output Current Sensors CTS-20; CTP-20

CR Series Command Relays

T4398A,B Precision Electric Heating Thermostat

High-Density Industrial

T7984 A,B,C Electronic Modulating Control Thermostats

HE220, HE260 Humidifier Installation Kit

ST. KITTS CEILING FAN

T7047C,G,H Remote Space Sensors

INSTALLATION. Glass Panel Doors (select models) CAUTION

TP970 and TP9600 Series Pneumatic Thermostats

USSC LLC 4 ONE LLC FIELD MODIFICATION INSTRUCTIONS

R Series B & T2 Model

Honeywell Durafit LED Retrofit Kit

Installation. Leveling

The T6140A,B Remote Bulb Temperature Controller

ELSTON 52 CEILING FAN

TK-1001, 1101, 1201, 1301, 1601

T834C Heating-Cooling Thermostat

T874 Multistage Thermostat and Q674 Subbase

TK-5001, Pneumatic Room Thermostats General Instructions GENERAL INFORMATION INSTALLATION

Dishwasher Installation Instructions DW 24XT/DW 24XV

52 SAN LUCAS CEILING FAN

Undercounter Refrigeration

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

ASSEMBLY and INSTALLATION INSTRUCTIONS. Pipe wrench Ratchet 3/8 socket 9/16 socket 11/16 socket 3/16 Allen key 3/32 Allen key 9/64 Allen key

Bathroom Exhaust Fan/Fluorescent Light Combination

INSTALLATION INSTRUCTIONS

F150E Media Air Cleaner

TOUCHDOWN 48 CEILING FAN

DUVAL 52 CEILING FAN MODELS #50201, Español p. 19 LISTED FOR DAMP LOCATION

Installation Guide. For Models: E-PD52ABZ5C4 E-PD52BP5C4 E-PD52WW5C4 READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE

SPRINGHILL 44 CEILING FAN

TB8220U Commercial Programmable Thermostat OWNER S GUIDE

F200E Charged-Media Air Cleaner

SS1095 Ice Maker.

T6984 A,D,E Electronic Floating Control Thermostats

CEILING FAN OWNER S MANUAL

Cooktop Chimney Ventilation Hoods

Installation Instructions

QFP Carrier & Development Socket

MAYFIELD CEILING FAN LISTED E ITEM # MODEL #BTH44ABZC5C BTH44BNK5C Español p. 20 ATTACH YOUR RECEIPT HERE.

Installation Guide. For Models: E-DCF52BNK5C3 E-DCF52FBZ5C3 E-DCF52MWW5C3 READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE

CENTERLINE 2100 Motor Control Center (MCC) Doors and Units with Vertical Operating Handles

Merloni Elettrodomestici. Technical Fitting Manual DISHWASHER. Language Issue/Edition Page GB /

Bathroom Exhaust Fan/Fluorescent Light Combination

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

T874A-F Multistage Thermostats; Q674A-G Subbases by Honeywell

READ AND SAVE THESE INSTRUCTIONS

Installation Instructions

Built-In Dishwasher. Installation Instructions. BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT The dishwasher MUST be

Model 6021 Electrically Heated Rain and Snow Gauge

TILGHMAN CEILING FAN. LISTED For Damp Location E ITEM # MODEL #WCK52LMW5N WCK52NWZ5N. Español p. 20 ATTACH YOUR RECEIPT HERE

CORALAIS BODYSPA BATH AND SHOWER FAUCET

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS

Service Manual 26 Self Trimming Fireplace with 3 Stage Remote

INSTALLATION GUIDE Dual Fuel Ranges

Integrated Refrigeration

Installation Instructions

Installation/Care/Use Manual EZH20 In Wall Bottle Filling Station

F25F Media Air Cleaner

INSTALLER'S GUIDE. ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES

Mariner Microspray and Low-Flow Electrospray Fused Silica Spray Tip and Capillary Kit. Operating Instructions. 1 Product Description.

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

TK-2001, TK-2012, TK-2201, TK-3001, TK-3201, TK-4001, TK-4012, TK-4212 TK

INSTALLATION INSTRUCTIONS

DAGNY LK. Ceiling Mounted Rotational Fan READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 110V~60Hz

Installation Instructions

RESIDENTIAL GAS WATER HEATERS

52 BAYTOWNE CEILING FAN

Sanitise Syrup Lines & Valves. Taylor PH61 Cleaning every 14 days

SUTTON 52 CEILING FAN

Installation Manual PS-200 & PS-201

Top Control Dishwasher

C L E A N I N G / M A I N T E N A N C E WA R R A N T Y I N F O R M AT I O N CLEANING/MAINTENANCE FAN STORAGE 3 YEAR LIMITED WARRANTY INSTRUCTIONS

Installation Instructions EFS Hand Washing Station

WARNING: ELECTRICAL GROUNDING INSTRUCTIONS

Bliss Box Former Troubleshooting. 6.1 Troubleshooting Chart. Troubleshooting INTRODUCTION SAFETY PROCEDURES

Installation Instructions

Rotary XL (558 Series) and Classic (548 Series)

ASTRO ENVELOPE FEEDER AMC FOR HEIDELBERG PRINTMASTER INSTALLATION AND OPERATING INSTRUCTIONS

Installation Guide. For Models: E-MLV36BNK4LK1 E-MLV36ESP4LK1 E-MLV36WW4LK1 READ THESE INSTRUCTIONS AND AND SAVE THEM FOR FUTURE USE

CT500 Electronic Thermostat

Model H1011.8/H1011.8HPS Water Cooler

Transcription:

TP970 SERIES 14002424 ASPIRATING WALL ASSEMBLIES BEFORE INSTALLATION 1. The HP970 and TP970 Series Aspirating Wall Box Assembly (Fig. 1) is available in two versions: - 14002424-002 Aspirating Wall Box Assembly with stud mounting bracket and screw - 14002424-003 Aspirating Wall Box Assembly with mounting clip for hollow wall mounting 2. The Box can be mounted vertically or horizontally. Preferred mounting is with the tubing entering from the top or left so that the thermostat is in the normal position when mounted. 3. The Box can be roughed in and the thermostat and cover added later. 4. The aspirator must always be mounted on the opposite end of the Box from where the tubing enters. Position the thermostat with the setpoint knob at the aspirator end of the Box. 5. The Box is furnished with two, encased, 8 ft (2.4m) long 5/32-in. (4 mm) O.D. polyethylene tubes for main and branch connections. 6. The following are ordered separately and are required to complete the installation: - TP970 Series Pneumatic Thermostat - AK3970 Cover Plate 1 U 2-112 (64) 1-7/8 (48) (2) 4-3/8 (112) 3116 (5) Rev, 12-89 Fig. 1. Dimensions In Inches (Millimeters) of 14002424 Aspirating Wall Box with AK3970 Cover Plate, 95-7163 Copyright 1989 Honeywell Inc. Commercial Bldg Group All Rights Reserved MLF TAB: II. C. 10.

INSTALLATION ASPIRATING WALL Figures 2 and 3 illustrate mounting details for the Aspirating Box. CAUTION Leave the protective paper cover (Fig. 3) on the thermostat mounting plate until construction has been completed and the thermostats are ready to be installed (see THERMOSTAT). The paper cover seals the Box from dust during construction. CLIPS (4) INSULATION PROTECTION ASSEMBLY THERMOSTAT ASPIRATOR PROTECTIVE PAPER (LEAVE IN PLACE UNTIL THERMOSTAT IS MOUNTED) ASPIRATOR C4854 Fig. 2. Vertical Mounting (Preferred) with Tubing through the Top and Thermostat in the Upright Position. THERMOSTAT--. NOTE: PROPER AIR HEAD AND ASPIRATOR ARE AS DETAILED IN FIG. 2. ASPIRATOR IS ALWAYS MOUNTED IN OPPOSITE END OF FROM TUBING ENTRY. C4847 Fig. 3. Mounting Plate Serves as a Rough-In Plate, Leave in Position until Mounting Thermostat. 95-7163 2

14002424-002 ASPIRATING WALL ASSEMBLY (STUD ) This assembly is mounted to a stud or directly to a wall. ON STUD 1. Mount the mounting bracket on the Box as shown in Figure 4. 2. Mount the Box and bracket to the stud as shown in Figure 4 or 5. 1-1/2 (38) OFFSET FOR (2) EXPANDED METAL SCREW ASPIRATING ASPIRATING NO. 8 X 1/4-IN. SELF-TAPPING BRACKET SCREW NO. 8 X 1/4-IN. SELF-TAPPING BRACKET OR THERMOSTAT 4 1A UP TO 1 IN. (25 MM) PROJECTION FROM STUD. 1-1/2 TO 2-1/2 IN. (38 TO 64 MM) PROJECTION FROM BRACKET SURFACE. -THERMOSTAT C4849 Fig. 4. Mounting 14002424-002 Wall Box. Dimensions in Inches (Millimeters). 3 95-7163

STUD TUBING (2) NO. 8 WOOD --- INSULATION Fig. 6. Mounting Aspirating Wall Box Directly to Wall. 14002424-003 WALL ASSEMBLY (HOLLOW WALL ) THERMOSTAT--- NO. 8 WOOD SCREWS (NOT SUPPLIED) Fig. 5. Mounting 14002424-002 Wall Box to Wood Stud. DIRECTLY TO WALL This assembly is mounted through a hole cut into a hollow wall (Fig. 7 and 8). 1. Cut a hole in the wall (Fig. 7). 2. Pull tubing through the hole and terminate to tubing from Box. 3. Remove thermostat mounting plate (Fig. 2) from front of Box. 4. Insert Box into hole in wall. When mounting onto a block or brick wall (Fig. 6), cover the expanded metal screw holes with masking tape to prevent the mortar from filling the holes. 1. Remove the tubing and insulation (Fig. 2) from the Aspirating Box. NOTE: Optionally, the Box can be mounted without disassembly by driving screws through insulation. 2. Mount the Box using two No. 8 wood screws (not supplied) through the back of the Box. 3. Reinstall the insulation and tubing in the Box. 4-1/2 (115) 95-7163 A Fig. 7. Mounting Hole Dimensions in Inches (Millimeters).

5. Install two clips (Fig. S), long tab up, on sides of Box. 6. Push Box flush with wall, pull foward on clips, and bend tabs firmly into Box. Squeeze tabs against insulation in box to provide clearance for thermostat. 7. If roughing-in only, replace mounting plate on front of Box; otherwise proceed to THERMOSTAT section. THERMOSTAT Mount the thermostat only after wall construction is completed. 1. Peel off and discard the adhesive backed protective paper from the mounting plate. See Figure 9. LONG THERMOSTAT -PEEL AWAY PAPER FROM THIS END -ACCESS HOLE FOR BRANCH LINE PRESURE PLUG -ACCESS HOLE FOR SETPOINT CALIBRATION PROTECTIVE PAPER (LEAVE IN PLACE UNTIL THERMOSTAT IS MOUNTED) CLIP (2) C4853 Fig. 8. Mounting 14002424-003 Wall Box with Clips Furnished. C4848 Fig. 9. Mounting Plate of Roughed-In Aspirating Wall Box. 2. Remove the two screws that hold the mounting plate (Fig. 9) to the Box. NOTE: During construction this plate serves as a rough-in plate. 3. Remove mounting plate. NOTE: The plate contains the aspirator, air head, and mounting spring clips. 4. Remove the protective cap from the air head. 5. Plug the air head into the thermostat. NOTE: Be sure that the main and the branch arc properly oriented. The short connecting tube from the aspirator to the air head is main air feed to the thermostat. Be sure that MAIN air is connected to the aspirator. The tubing from the thermostat to the tubing entry has BRANCH printed on it. 5 95-7163

6. Mount the thermostat on the spring clips (Fig. 10). All 7. Mount thermostat in the Box by replacing the four clips must fit into the slots provided in the metal mounting plate and fastening with the two screws. plate of the thermostat. NOTE: Be sure the aspirator is mounted in the opposite end of the Box from the tubing entry. If recalibration is required, USC access holes as shown in Figure 9 for thermostat installations. 8. Mount the cover plate using a 5/64-m. Allen wrench. The cover plate is correctly mounted only when the cutout in the insulation is aligned with the air cutout in the mounting plate. Observe markings on the inside of the cover plate for proper orientation of cover, Fig. 10. Mounting Plate with Thermostat Mounted. By using this Honeywell literature, you agree that Honeywell will have no liability for any damages arising out of your use or modification to, the literature. You will defend and indemnify Honeywell, its affiliates and subsidiaries, from and against any liability, cost, or damages, including attorneys fees, arising out of, or resulting from, any modification to the literature by you. 95-7163 HONEYWELL Minneapolis, Minnesota 55408 Scarborough, Ontario M 1 P 2V9 Subsidiaries and Affiliates Around the World Printed in U.S.A.