READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS

Similar documents
Long Case Axial Fan. Installation and Wiring Instructions V/1/50Hz & V/3/50Hz

SUPER T WALL FANS. Installation and Wiring Instructions

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH THE ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS

EKF. EC kitchen extract fan range. Installation and Wiring Instructions. Stock Ref. N EKF355E1 EKF400E1 EKF450E1 EKF450E3 EKF500E3 EKF560E3

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref.

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Lo-Carbon Quadra Centrifugal Fan

Lo-Carbon SELV Tempra

Installation and Wiring Instructions

Centrif Duo & Centrif Duo Plus

Lo-Carbon Quadra SELV

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Silhouette Installation and Wiring Instructions

Lo-Carbon T-series Window & Roof Models

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

DUCT AIR HEATER WITH BUILT-IN CONTROLS. Installation & User Instructions. Stock Ref T T T3

VA 150 A, VA 150 P WINDOW EXTRACT FAN. Installation and Wiring Instructions V/1/50Hz

T-SERIES. Window & Roof Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

T-SERIES. Wall & Panel Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

Lo-Carbon Quadra Centrifugal Fan

HR200WK Through the wall Heat Recovery Ventilator

EXTRACTOR HOOD. Please read all the instructions carefully before starting the installation. 230 / 240V 50Hz

Lo-Carbon SOLO Plus SELV Centrifugal Bathroom/Toilet Fan

INTEGRA PLUS ABC. 230V~ 50Hz. Stock Ref. N. Installation and Wiring Instructions IPX2

VA100 SELV 12 RANGE. Installation and Wiring Instructions IPX7

Vent-Axia Svara Multifunctional app controlled fan. Important Information 2 Installation and Wiring Instructions 3-11 Accessories 12 Pin Code 12

Integra. Integra Plus EC MVHR. Installation & Commissioning. Stock Ref. N EC Integra Plus EC PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT.

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Operation & Monitoring. Stock Ref. N

100 FLUEBOOST

Sentinel Kinetic MVHR RANGE

FLUEBOOST. flueboost 350 gas fire model

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Operation & Monitoring. Stock Ref. N

Lo-Carbon PoziDry Pro

Purge Ventilation Unit. Product Manual. ventilation systems TP625

INSTALLATION, OPERATION & MAINTENANCE MANUAL

XB-EFA-8L-BK & XB-EFA-8R-BK

Model: Kair Whole House Ventilator Model Number: KHRVWH2000

Warnings, Safety Information and Guidance

"WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use

A Fläkt Woods Company 2933 Symmes Road, Fairfield, Ohio Phone: (513) Fax: (513)

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

AXUS - SC Short Cased Axial Flow Fans Installation and Maintenance

ECOSMART TWINFANS. (EST) 1 phase, Direct Drive, Run & Standby Fans for indoor use. Installation and Maintenance

HIT Centrifugal In-Line Fan


CI/SfB (57.7) 1st Edition. Vent-Axia Sentinel Kinetic Horizontal Range. Vent-Axia MVHR Units

INDOOR USE ONLY. Installation and Maintenance XTRACTOR. (ESX) 1 and 3 phase, Direct Drive, Fans for indoor use

12 VELOCITY OWNER S MANUAL OPERATING INSTRUCTIONS - MAINTENANCE - SAFETY - TROUBLESHOOTING

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY

DBF 4XL Dryer Booster Fans

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

PUREAIR SENSE. Instruction Manual. A product by. B at hroom Fan wi t h O dour Sen se Tec h n ology Vent-Axia PureAir Sense F&W Manual.

Indirect gas-fired air heater

INSTALLATION INSTRUCTIONS USER GUIDE

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL

WHHR Midi & Midi Lite

SMHA Hatch High temperature fan HT-fan Installation and Maintenance

ELTA FANS IN-LINE MIXED FLOW FAN IMF100 / 125 / 150 / 200 INCLUDING MODELS WITH BUILT-IN-RUN-ON TIMERS T

CI/SfB (57.7) 2nd edition. Lo-Carbon Quadra

MJC Cartridge Filter Unit Operation & Maintenance

Condensing Units CUS 15-60

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

Instructions for the BASIC BCRW Fan, Sizes General

IN-LINE CENTRIFUGAL FAN VENTS VKP PS 125. User`s manual.

Breezex (BX) Heavy Duty Reversible Supply/Exhaust Fans with Reversing Switch. IMPORTANT! Read before proceeding! OPERATION & MAINTENANCE MANUAL

MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER

RL Series Commercial/Residential Ventilation Fan Installation Instructions Please Read And Save These Instructions.

USER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING

SWP. (Models SWP08 through SWP20) IMPORTANT! Read before proceeding! OPERATION & MAINTENANCE MANUAL

Lo-Carbon Sentinel Kinetic Horizontal

Trimbox Mixed Flow Fans. Product Manual. ventilation systems TP220T TP221T TP222T TP223T

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

JM Aerofoil Fans Bulletin JMA60-05

ECOSMART XTRACTOR. (ESX-X/R/B) 1 phase, Direct Drive For External, Roof Mounted and Internal use Installation and Maintenance.

Installation and Maintenance Novax Smoke Exhaust Fan Type ACN Smoke


READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

Sentinel. Kinetic Advance MVHR. Installation & Commissioning. Stock Ref. N Advance S Advance SX

AHU INSTALLATION & OPERATION MANUAL

01 Safety. IMPORTANT Be sure to have read and understood these instructions before beginning the installation process.

Bathroom Exhaust Fan

DUAL VOLTAGE REFRIGERATORS 220/240 VOLTS AC AND 12/24 VOLTS DC INSTALLATION AND OWNER S MANUAL

Ventilation Fan Model VFB24ACTH VFB24ADTH VFB24AXTH

Supply air unit VEKA Installation & Maintenance

Bosch 80% AFUE Gas Furnace BGS80 Model

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Installation & Commissioning

ACN SMOKE INSTALLATION AND MAINTENANCE

LUH HORIZONTAL FAN-FORCED UNIT HEATER

Assessment Schedule - TS8

more than just a fan supplier more than just a fan supplier Axair Fans UK Limited

ECOSMART TWINFANS. (EST-X/R/B) 1 phase, Direct Drive, Run & Standby For External, Roof Mounted and Internal use Installation and Maintenance

1 - Donkin Fans. Majax-2 Aerofoil Axial Flow Fans

Hodge Clemco Ltd. MJC Mini Cartridge Filters Owners Manual. TSOM 556 Date of issue 13/07/04. Hodge Clemco Ltd

90cm Chimney Extractor

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

"Microbox" DC Models MBOX 125/2DC MBOX 125/2DC204

CI/SfB (57.7) 1st Edition. Lo-Carbon Response/SELV dmev Unit. A new generation of Lo-Carbon continuous running fans

Transcription:

Bifurcated Axial Fan Installation and Wiring Instructions 220-240V/1/50Hz & 380-415V/3/50Hz RAD INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS PLAS SAV THS INSTRUCTIONS

Installation and Wiring Instructions for the Bifurcated Axial Fan. IMPORTANT: RAD THS INSTRUCTIONS BFOR COMMNCING TH INSTALLATION DO NOT install this product in areas where the following may be present or occur: xcessive oil or a grease laden atmosphere. Corrosive or flammable gases, liquids or vapors. Ambient temperatures less than 5 C or higher than 200 C (60 C when speed controlled). SAFTY AND GUIDANC NOTS Air moving equipment may present mechanical, electrical or noise hazards. To minimise the risks associated with these potential hazards, it is essential that installation, operation and maintenance instructions are followed and carried out by a suitably qualified person. A. All wiring to be in accordance with the current I... Regulations, or the appropriate standards of your country. B. The Fan should be provided with a local double pole isolator switch having a contact separation of at least 3mm. C. nsure that the mains supply (Voltage, Frequency, and Phase) complies with the rating label. D. The Fan should only be used in conjunction with the appropriate Vent-Axia products.. It is recommended that the connection to the terminal box is made with flexible cable/conduit. F. The fan should not be sited within 600mm horizontally of/or 2250mm vertically of a bath/shower tray, in accordance with the I... Regulations for bathrooms. G. When the Fan is used to remove air from a room containing a fuel-burning appliance, ensure that the air replacement is adequate for both the fan and the fuel-burning appliance. H. If the Fan is used to supply air into a room, the installer must ensure that the fan intake is located a minimum of 600mm from any flue outlet. I. This Fan is designed as an inline ducted fan to be positioned between lengths of ducting. Short duct runs terminating within 1.5m must incorporate suitable guards. J. Certain applications may require the installation of sound attenuation material, together with either an Auto Transformer or Inverter Speed Controller to achieve the sound levels required. DSCRIPTION. The Bifurcated Case Axial range of fans incorporates factory adjustable pitch impellers, which provide a comprehensive range of duties offering high performance and pressure characteristics. Available in Nine sizes ranging from 250mm to 1000mm ø and performances from 0.27m 3 /s to 19.1m 3 /s with a pressure development up to 700Pa. The casing is constructed from rolled steel plate and protected with a galvanised finish. A. INSTALLATION. 1. nsure the impeller rotates and is free from obstruction, prior to installation. 2. The fan is suitable for mounting at any angle. 3. nsure that there is adequate clearance for accessing and ventilating the fan. 4. Securely mount the fan using the holes in the end flanges and use the appropriate drop rods, bolts, antivibration mountings etc. 5. nsure the Airflow Arrow is aligned with the direction of the airflow required. 6. The use of flexible connections and anti-vibration mountings is recommended to minimse noise and vibration. 7. nsure that the flexible connections are taut and the fan and ductwork are aligned. 8. Flexible connections MUST be used in conjunction with anti-vibration mountings. 9. Anti-vibration mountings must be installed in compression. 2

Fig.1. TYPICAL INSTALLATION (Horizontal). BIFURCATD FAN FLXIBL CONNCTION FLXIBL CONNCTION MOUNTING FT WIRING ANTI-VIBRATION MOUNTINGS WARNING: TH FAN AND ANCILLARY CONTROL QUIPMNT MUST B ISOLATD FROM TH POWR SUPPLY DURING TH INSTALLATION / OR MAINTNANC. TH QUIPMNT MUST B ARTHD 1. Select and follow the appropriate wiring diagram (Figs. 2-10). 2. Check all connections have been made correctly and ensure that all terminal connections and cable clamps are securely fastened. 3. The cable entry must be made using a suitable grommet or cable gland. 4. Switch the mains power supply on and check the fan is operating correctly. Fig. 2. Single Phase Fan Connected to a 240V D.O.L. Starter. Fig. 3. Single Phase Fan Connected to a 240V D.O.L. Starter an Auto Transformer Speed Controller. 1 Phase Supply (220-240V 50 Hz). L ~ N 1 Phase Supply (220-240V 50 Hz). L ~ N BIF250/2/1/8-32 BIF315/2/1/8-32 240 Volt D.O.L. Starter A suitable sized overload relay must be fitted to provide motor protection. N.B. Links between terminals 1 to, 3 to 6, 5 to 95 and 24 to 96 must be fitted. BIF250/4/1/8-32 BIF315/4/1/8-32 L 1 2 3 4 N 5 6 U1 95 96 U2 23 24 240 Volt D.O.L. Starter A suitable sized overload relay must be fitted to provide motor protection. N.B. Links between terminals 1 to, 3 to 6, 5 to 95 and 24 to 96 must be fitted. 1 Phase Auto Transformer Speed Controller. 103 14 105 1 3 2 4 L2 N1 5 6 L Fuse L1 95 23 96 24 N N FAN TRMINAL BIF250/4/1/8-32 BIF315/4/1/8-32 L U1 N U2 FAN TRMINAL 3

Fig. 4. Three Phase Fan Connected to a 415V D.O.L. Starter. Fig. 5. Three Phase Fan Connected to a Star / Delta Starter. 3 Phase Supply (380-415V 50Hz). L1 L2 L3 STAR / DLTA Starter with current overload protection and a 415 volt coil. 3 Phase Supply (380-415V 50Hz). L1 L2 L3 415 Volt D.O.L. Starter A suitable sized overload relay must be fitted to provide motor protection. 1 3 5 23 24 95 96 1 2 3 4 5 6 95 23 N.B. Links between terminals 5 to 95 and 24 to 96 must be fitted. 2 4 6 96 24 STAR / DLTA STARTR 2 4 6 L1 L2 L3 BIF 250/2/3/8-32º BIF 250/2/3/8-32º BIF 315/2/3/8-32º BIF 315/4/3/8-32º BIF 400/2/3/8-28º BIF 400/4/3/8-32º BIF 500/4/3/8-30º BIF 630/4/3/8-26º FAN TRMINAL W2 U2 V2 U1 V1 W1 FAN TRMINAL Fig. 6. Three Phase Fan Connected to a 415V D.O.L. Starter and an Auto Transformer Speed Controller. BIF 500/2/3/18-26º BIF 800/4/3/8-18º 3 Phase Supply (380-415V 50Hz). N L1 L2 L3 415 Volt D.O.L. Starter A suitable sized overload relay must be fitted to provide motor protection. 1 3 5 N.B. Links between terminals 1 to, 5 to 95 must be fitted and the link between terminals 24 to 96 must be FITTD. 95 23 2 4 6 96 24 3 Phase Auto Transformer Speed Controller. 103-14-301 103-14-304 103-14-307 103-14-311 TK TK W1 V1 U1 N L3 L2 L1 BIF 250/4/3/8-32º BIF 315/4/3/8-32º BIF 400/4/3/8-32º BIF 500/4/3/8-30º BIF 630/4/3/8-28º FAN TRMINAL NOT: If an Auto Transformer is being used to control the Fan speed, the reset facility MUST be disabled. 4

Contact Vent-Axia s Technical Support Line for details. Fig. 7. Three Phase Fan Single Phase in Three Phase (240V) Out Bifurcated Fan connected to an Inverter Speed Controller Kit (103 20 101). 1 Phase Supply (220-240V). L~N 10 Volt D.C. (up to a maximum distance of 50m from the Inverter to the speed controller. Inverter 455552 User Fan Speed Controller ILVC 1 (103-20-601) Ferrite Coil (Loop the fan supply cable around the ferrite coil 3 times). Metal nclosure & Wiring by others. Connector Shielded Cable (WRAP WITH INSULATION TAP DO NOT CONNCT TO TH ARTH TRMINAL). (WRAP WITH INSULATION TAP). BIF 250/2/3/8-32º BIF 315/2/3/8-30º BIF 250/4/3/8-32º BIF 315/4/3/8-32º BIF 400/4/3/8-32º 3 PHAS SUPPLY (230-240 Volts) FAN TRMINAL Fig. 8. Three Phase Fan Single Phase in Three Phase (240V) Out Bifurcated Fan connected to an Inverter Speed Controller Kit (103 20 102 or 103 20 103). 1 Phase Supply Phase Supply (220-240V). (220 240V). L~N ~N 10 Volt D.C. (up to a maximum distance of 10 Volt D.C. (up to a maximum distance of 50m 50m from from the the Inverter Inverter to the to speed the speed controller. controller. Inverter 455553 455552or 455554 Metal nclosure & Metal Wiring nclosure by others. Wiring by others. Connector Connector User Fan Speed User Controller Fan Speed ILVC Controller 1 (103-20-601) ILVC 1 (103-20-601) Ferrite Coil Ferrite Coil (Loop the fan supply cable around the (Loop ferrite coil the 3 fan times). supply cable around the ferrite coil 3 times). (WRAP WITH (WRAP WITH INSULATION TAP). TAP). Shielded Shielded Cable Cable (WRAP WITH INSULATION TAP DO NOT (WRAP CONNCT WITH INSULATION TO TH TAP ARTH DO NOT TRMINAL). CONNCT TO TH ARTH TRMINAL). BIF 250/2/3/8-32º BIF 250/4/3/8-32º BIF 400/2/3/18-22º BIF 500/4/3/8-32º BIF 315/2/3/8-30º BIF 315/4/3/8-32º BIF 500/2/3/8-20º BIF 630/4/3/8-26º BIF 400/4/3/8-32º 3 PHAS SUPPLY (230 PHAS - 240 SUPPLY Volts) (230-240 Volts) FAN TRMINAL FAN TRMINAL 5

Fig. 9. Three Phase Fan. Three Phase In Three Phase Out. Bifurcated Fan connected to an Inverter Speed Controller Kit (103 20 301, 103 20 302, 103 20 303 or 103 20 305). Metal nclosure & Wiring by others. 10 Volt D.C. (up to a maximum distance of 50m from the Inverter to the speed controller. Inverter 455556, 455557, 455558 or 103 20 303 User Fan Speed Controller ILVC 2 (103-20-602) Filter 103-20-505 103-20-512 BIF 250/2/3/8-32º BIF 315/2/3/8-30º BIF 400/2/3/8-22º BIF 500/2/3/8-20º BIF 250/4/3/8-32º BIF 315/4/3/8-32º BIF 400/4/3/8-32º BIF 500/4/3/8-32º BIF 630/4/3/8-26º 6

Fig. 10. Three Phase Fan. Three Phase In Three Phase Out. Bifurcated Fan connected to an Inverter Speed Controller Kit (103 20 350). Metal nclosure & Wiring by others. 10 Volt D.C. (up to a maximum distance of 50m from the Inverter to the speed controller. Inverter 455559 User Fan Speed Controller ILVC 2 (103-20-602) Filter 103-20-512 BIF 800/4/3/8-18º ROUTIN INSPCTION AND MAINTNANC ISOLAT FROM TH POWR SUPPLY AND NSUR THAT TH FAN CAN NOT B ACCIDNTALLY SWITCHD BACK ON. 1. At intervals appropriate to the installation, the fan should be inspected and cleaned to ensure there is no build up of dirt or other deposits on the impeller or motor. If the fan is handling dust laden air, it is recommend that a filter is installed. 2. All Case Axial fans have sealed for life bearings and do not require lubrication. 3. Check the condition and security of all fixing bolts, rods, anti-vibration mountings, and flexible connections 7

The abc Guarantee Applicable only to products installed and used in the United Kingdom. For details of guarantee outside the United Kingdom contact your local supplier. Vent-Axia guarantees its products for two years from date of purchase against faulty material or workmanship. In the event of any part being found to be defective, the product will be repaired, or at the Company s option replaced, without charge, provided that the product:- Has been installed and used in accordance with the instructions given with each unit. Has not been connected to an unsuitable electricity supply. (The correct electricity supply voltage is shown on the product rating label attached to the unit). Has not been subjected to misuse, neglect or damage. Has not been modified or repaired by any person not authorised by the company. IF CLAIMING UNDR TRMS OF GUARANT Please return the complete product, carriage paid to your original supplier or nearest Vent-Axia Centre, by post or personal visit. Please ensure that it is adequately packed and accompanied by a letter clearly marked Guarantee Claim stating the nature of the fault and providing evidence of date and source of purchase. The guarantee is offered to you as an extra benefit, and does not effect your legal rights abc Head Office: Fleming Way, Crawley, West Sussex, RH10 9YX. Tel: 01293 526062 Fax: 01293 551188 UK NATIONAL CALL CNTR, Newton Road, Crawley, West Sussex, RH10 9JA SALS NQUIRIS: Tel: 0844 8560590 Fax: 01293 565169 TCHNICAL SUPPORT: Tel: 0844 8560594 Fax: 01293 539209 Web:-www.vent-axia.com mail:- info@vent-axia.com As part of the policy of continuous product improvement Vent-Axia reserves the right to alter specifications without notice. 443396A 0910 8