SILOXA FAKA Gas Cleaning System

Similar documents
PROTEGO Deflagration Flame Arresters. and Vent Caps. Volume 2. end-of line. Volume 2. for safety and environment

PROTEGO Deflagration Flame Arresters. and Vent Caps. Volume 2. end-of line. Volume 2. for safety and environment

INSTALLATION AND OPERATION MANUAL

VACUUM HEATING AND DRYING OVENS Gentle and safe

Air-Drying Device. PROTEGO LA and LA/V. Function and Description LA/V. Figure 2 Figure 3

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

Technical manual 2G-TA 04 - Gas

Metropolitan. Steam Boiler. Suitable for Pressure Jet or Rotary Cup burners Oil, gas or dual fuel firing. Outputs kg/h

GAS CONDENSING TECHNOLOGY

monitoring air flow gas detection temperature sensors CASE STUDY GAS DETECTION SYSTEM AT LOWER LEA VALLEY CABLE TUNNELS For Murphy Group/National Grid

KDE. PRESSURIZED STAINLESS STEEL CONDENSING BOILER FROM 124 kw TO 2160 kw

V A C U U M A N D P R E S S U R E T E C H N O L O G Y

Dryer Systems. Breathing Air Units

THW-I NTE. Description THW-I NTE. Industrial Hot Water Boiler THW-I NTE for Oil or Gasfiring. Industrial Hot Water Boiler

FUTURE COMBUSTION ENGINE POWER PLANT WP4 Fuel Fuel Flexibility. Minimum limit for biogas upgrading

portable gas analyser

Savile Plus. Steam Boiler. Suitable for Pressure Jet burners Oil, gas or dual fuel firing. Outputs kg/h

Series 57 WATER/OIL SEPARATORS

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

R e m e h a P Technical Information. Remeha P 300. Pressurized boiler. Heat output: kw

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

Chapter 9: The basics of air preparation

BINDER Scientific Product Catalog

EXAMPLES OF HOW TO ORDER

METPOINT OCV. e. g. SAFE PROCESS THROUGH MONITORING. FOR CHALLENGING COMPRESSED-AIR APPLICATIONS Pharmaceuticals. Food Chemical Coating

Project demonstrates benefits of traceable on-line measurement of siloxanes in industrial biogas Solving the siloxane measurement problem

EXAMPLES OF HOW TO ORDER

INDUSTRIAL / DOMESTIC WATER HEATERS

GRUNDFOS ALLDOS DISINFECTION. ALLDOS DISINFECTION SYSTEMS with Chlorine Gas 1 GRUNDFOS ALLDOS DISINFECTION

SERIES 46000E Bi-Directional In-Line Deflagration Flame Arrester

Filters & Centrifugal Separators

in/out connections outer Ø 25 bar (363 psi) 200 kg/h SS '000 (2.12 HP) 300 kg/h CU (661 lb/h) (3.18 HP) 300 kg/h SS (661 lb)

Air treatment solutions. Aftercoolers & condensate treatment

gas monitoring system

MFP14 Automatic pumps. for condensate and other industrial fluids

The ultimate in air handling units: directly and indirectly fired

CAST IRON PREMIX HIGH EFFICIENCY GAS FIRED BOILER kw BRILEY DESIGN MANUAL

High Efficiency Compressed Air Dryers. Adsorption Dryers Modular System INTELLIGENT AIR TECHNOLOGY

Heated Gas Sampling Probe PSG Basic

GAS DETECTION SYSTEMS

Dryer Systems Heat Regenerating Adsorption Dryers

Adsorption Air Dryers

VD 53 - Vacuum drying oven for non-flammable solvents

Industrial Cast-in Circulation Heaters for ATEX/IECEx hazardous areas or in non-atex version

DRYPACK. Protecting installations Energy optimisation. Operating principle. Description. Biogas dehumidification system. Improved profitability.

9.0 Systems For Domestic Water Installations

Product Data Sheet Adsorption Dryer DTS..V

Cooling with compressed air partial flow: the Heat Regenerating Adsorption Dryer EVERDRY FRP

Operating instructions

FlexFilter EX A state of the art filter system to meet your current and future needs

RS /E-EV C01 SERIES

Storage tank size Rated volume [l] Actual volume [l]

Product Overview. Ordering Information DM-LK-D10 DM-LK-D10-C. Dust & Opacity Meter Complete Set Controller Unit. Sender Receiver SDS-V5 SDR-V4 HPB-82S

Air/water - Heat pumps

RS /E-EV C01 SERIES

HEADLINE LOREM IPSUM COMPANY EFFICIENCY

Basic information about quick steam generators/boilers System GEKA Heat Technology Gottfried Kneifel

Planning, Manufacturing, Sales, Installation and Maintenance of Gas Measuring Systems and Gas Detection Systems for explosive and toxic gases.

ADOS Biogas 905. Multi-channel Gas Analyser. A D O S GmbH Instrumentation and Control Trierer Str FRG

ENTROPIE boiler TT300

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

BURNERS/ FLARES. VAREC BIOGAS 244W Series WASTE GAS BURNER & IGNITION SYSTEM

OPTIBAR DP 7060 Supplementary Instructions

VIESMANN. VITOMAX 200-LW Low pressure hot water boiler for permissible flow temperatures up to 120 C Rated heating output 8.0 to 20.0 MW.

Adsorption Compressed Air Dryer Heatless or heater regeneration

Compact VERTICAL FLAT. Compact. Condensers GCHC/GCVC for HFCs, NH 3

High Efficiency Compressed Air Dryers. Adsorption Dryers Modular System INTELLIGENT AIR TECHNOLOGY

VIESMANN. Datasheet VITOMAX 200-WS. Hot water boiler for permissible flow temperatures up to 110 C 1.75 to MW

2 OZONFILT And Bono Zon Ozone Plants

UVG Technical Description - Biogas upgrading (Biomethane)

VIESMANN. VITOMAX 200-WS Rated heating output 1.75 to MW. Datasheet. VITOMAX 200-WS Type M250

The ultimate in air handling units: directly and indirectly fired

Vacuum Switch, Differential Pressure Adapter, Switching Amplifier

ACO Marine Grease Traps Program. Grease Traps

Technical information Installation instructions. Modul-plus (F21-52) High performance calorifiers

DESICCANT AIR DRYERS. BD + CD + CD series

Product Data Sheet Adsorption Dryer DPS (A)

Operations Manual GMA 313 CO 2. Gas Monitor for one detection point

P R O D U C T D ATA S H E E T

GAS DETECTION SYSTEMS

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Installation & Maintenance Instructions SEPREMIUM 350. Oil /water separator 05/09

Dryer Systems Heat Regenerating Adsorption Dryers

SIHI dry Dry running vacuum pumps

RIELLO 40 GS/M SERIES

portable gas analyser

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

DESICCANT AIR DRYERS. BD + CD + CD series

VERY LOW TEMPERATURE CONDENSING UNIT Low NOx Class 5 MODELS SEASONAL EFFICIENCY A A A A A A A

MICRO III (G202 / G202s / G212) Single Gas Detector

NEXTorr Pumps. making innovation happen,together

PRODUCT GUIDE. ionscience.com Unrivalled Gas Detection.

Adsorption Dryers. AD 7 to 1300

Max-3 plus. Output range 420 to 2700 kw TopTronic E control. Steel Shell Boiler. Responsibility for energy and environment

LOW NOx MODULATING GAS BURNERS

and Installation Instructions The installation instructions for the Unit pressure jet oil burner is included in the pressure jet oil burner pack.

VIESMANN VITOLADENS 300-T Oil Unit condensing boiler 35.4 to 53.7 kw

Floorstanding Gas Condensing Boilers VITOCROSSAL 100

The ultimate in air handling units: directly and indirectly fired

Transcription:

1/6 Activated carbon adsorber for removing siloxanes and, if required, hydrogen sulphide (H 2 S) from sewage gas SILOXA s FAKA gas cleaning systems are highly efficient systems that are available in different versions, with one or two chambers or as a TWIN activated carbon adsorber. With the FAKA activated carbon adsorber, the essential precondition for compliance with the engine manufacturers limit values for combustion gas can be established. The adsorber containers are made of stainless steel (1.4301). The previously heated gas is cleaned by adsorption, using activated carbon that retains the siloxanes. When the uptake capacity of the activated carbon is reached, the saturated carbon can be emptied into Big Bags, easily and conveniently, through the cone shaped base of the container. Fresh ACO sorb[si] activated carbon (Big Bags) can then be used to fill the container from the top. A platform with fixed ladder or a work platform with fixed ladder (DIN EN ISO 14122) allows the work to be carried out safely and easily in accordance with the health and safety regulations. Using a gas analyser at the measurement points on the bottom of the FAKA container, it is possible to determine exactly when the used activated carbon needs to be replaced. Gas samples can be taken from these sampling points and then analysed in order to determine the level of saturation of the activated carbon. This gives advance warning of the need to renew the activated carbon. Due to the separation of the chambers in the two-chamber (K2) FAKA, it is possible to remove only the saturated carbon from the lower chamber and then replace it with the fresh activated carbon from the upper chamber. This ensures maximum utilisation of the activated carbon in the lower filter chamber and extends the service life of the activated carbon by around 15%. The FAKA two-chamber adsorbers are available in three different sizes, to suit different requirements and applications. In the FAKA activated carbon adsorbers, only high-performance ACO sorb[si] activated carbon is used. This activated carbon is a premium product with a consistently high quality standard, a key component that plays an important role in efficient system operation.

2/6 Make optimal use of the activated carbon with the convenient FAKA system. Sizes/net capacity Type description Net capacity Diameter Height FAKA 3000 K2E 2 x 1,500 l 1,270 mm 9,980 mm * FAKA 6000 K2E 2 x 3,000 l 1,900 mm 9,980 mm * FAKA 7000 K1E 7,000 l 1,900 mm 9,980 mm * FAKA 3000 K2E TWIN 2 x 1,500 l plus 2 x 1,500 l 1,270 mm 9,980 mm * FAKA 6000 K2E TWIN 2 x 3,000 l plus 2 x 3,000 l 1,900 mm 9,980 mm * FAKA 7000 K1E TWIN 7,000 l plus 7,000 l 1,900 mm 9,980 mm * * Height with crane Technical description Features Consumption costs The filter system ensures that downstream plant components have a long service life Significant lengthening of CHP maintenance intervals Prevention of deposits in the combustion chamber High availability of gas utilisation system, operational reliability, low maintenance Opportunity for upgrading with further options Easy replacement of activated carbon with Big Bags The activated carbon consumption is determined by the siloxane or H 2 S load and the gas quantity The adsorber is optimised for quick and easy activated carbon replacement, to keep wage costs and downtimes as low as possible Large adsorber volumes reduce specific replacement costs because the greater the quantity of activated carbon replaced, the lower the specific costs for transport, wages and downtimes Packing of activated carbon in Big Bags reduces transport costs Service SILOXA offers a full range of services throughout Europe for the operation of gas cleaning systems with activated carbon adsorbers, from delivering the activated carbon to full service.

3/6 The siloxane uptake is easily tested via the gas sampling point. FAKA Stainless Steel Stainless steel construction (1.4301) basic features 2 gas connections (gas inlet and outlet) DN 200 PN10 Inspection opening DN 500 Connecting piece with ball valves for inertisation and taking gas samples Shut-off valve for emptying activated carbon DN 150 Ladder with cage and platform or work platform with handrail Thermal insulating mineral wool 50 mm and aluminium sheet jacket Crane unit with winch mechanism and electric chain hoist (650 kg lifting capacity) Galvanised steel supporting structure TWIN FAKA Stainless steel construction (1.4301) basic features Uninterruptible operation possible Gas connections (gas inlet and outlet) DN 200 PN 10 depending on flow rate Inspection opening DN 500 Connecting piece with ball valves for inertisation and taking gas samples Shut-off valve for emptying activated carbon DN 150 Thermal insulating mineral wool 50 mm and aluminium sheet jacket Ladder with cage and platform or work platform with handrail Crane unit with winch mechanism and electric chain hoist (650 kg lifting capacity) Galvanised steel supporting structure Available options Additional equipment for removing hydrogen sulphide (H 2 S) The adsorber is filled with ACO dotiert[s] Deflagration 2 flame arresters flame arrester EC type examination certification as per Directive 94/9/EC in accordance with ATEX 95 and EN 12874 Equipped with PT100 resistance thermometer Gas heating Flanged tube bundle heat exchanger for heating biogas, material in contact with gas media 1.4571 Pressure resistance, gas-side 0.5 bar (gauge)

4/6 Easy refilling of the activated carbon adsorber thanks to the working platform and the crane. Pressure resistance, jacket-side 6 bar (gauge) Gas connection depending on flow rate Heating connection 1 Hot water supply temperature 700 kg/h, 70 to 90 C, provided by customer Integration in gas supply is the responsibility of the customer H 2 S-Online-Analyse Gas sensor 0 to 100 ppm Condensate trap Evaluation unit with 4 floating contacts and analogue output, illuminated 4-line display, 2 alarm thresholds, 2 alarm, buzzer and fault relays Power supply and communication must be connected, and if necessary evaluated, by the customer Indoor and outdoor installation possible Air metering unit Diaphragm pump (required if the gas Flow rate indicator with regulating valve contains less than Activation is the customer s responsibility 0.5 % O 2 by volume) TÜV (Technical Inspection Agency) Safety Test Report Installation/ commissioning Machinery access ladder Safety temperature monitors Safety overpressure valve Installation of activated carbon adsorber on foundation provided by customer Carrying out commissioning and training available on enquiry on request on request, (design dependent on the customer s pressure generator) Operating information When using activated carbon adsorbers for removing hydrogen sulphide, please observe the following: For the removal of hydrogen sulphide, the fermentation gas must have an oxygen content of at least 0.5 and no more than 3.0 vol. %. The required minimum per centage of oxygen depends on the hydrogen sulphide load and can be specified in agree ment with Siloxa Engineering AG. The adsorber must be monitored by the operator to ensure that it functions properly. Siloxa Engineering AG accepts no liability for damage arising from insufficient monitoring of the adsorber function.

5/6 Technical Data Design parameters Material Medium Activatedcarbonreplacem.system Optional Number of chambers Diameter of the filter Activated carbon (working filter) Activated carbon (control filter) Nominal flow rate Max. flow rate Operating temperature Permissible operating pressure Max. operating pressure *1 Max. operating temperature Max. operating temperature *1 Pressure loss at max. vol. Pressure loss at max. vol. *1 Type of activated carbon FAKA 3000K2 E FAKA 6000K2 E FAKA 7000K1 E Stainless steel Sewage gas / landfill gas Big Bag Crane 2 2 1 1,270 mm 1,900 mm 1,900 mm 1,500 L 3,000 L 7,000 L 1,500 L 3,000 L 750 Nm³/h 1,400 Nm³/h 1,700 Nm³/h 900 Nm 3 /h 1,700 Nm³/h 2,000 Nm 3 /h 4 C to > -100 / < 300 mbar max. 160 mbar < 23 mbar < 18 mbar < 23 mbar < 36 mbar < 30 mbar < 37 mbar ACO sorb[si] Gas composition Methane CH 4 Carbon dioxide CO 2 Oxygen O 2 *2 Relative gas humidity *2 Relative gas humidity *3 Hydrocarbons C 5 Max. siloxanes Max. hydrogen sulphide H 2 S approx. 60 vol.-% approx. 40 vol.-% > 0,5 & < 3 vol.-% approx. 50-60 % < 50-60 % < 100 mg/m³ 1,000 mg/m³ 1,000 ppm Physical properties Gas density Specific heat capacity C P ca. 1,2 kg/nm³ ca. 1,6 kj/nm³ K Installation conditions Installation site Permissible temperature Inlet/outlet Inlet height Dimensions in mm (L x W x H) Dimensions in mm with crane Empty weight Operating weight Type of insulation Type of crane Max. lifting weight Electrical connection Construction: platform/ladder *1: with deflagration flame arrester option *2: with optional H 2 S removal only *3: for siloxane removal Outdoors - 15 to + 35 C DN 200 / 200 PN10 2,200 mm 3,742 x 3,090 x 6,822 2,470 x 3,341 x 6,660 2,470 x 3,341 x 6,660 3,742 x 3,090 x 9,980 3,742 x 3,341 x 9,980 3,742 x 3,341 x 9,980 2,700 kg 2,950 kg 2,850 kg 5,100 kg 7,750 kg 8,450 kg 50 mm mineral wool / sheet aluminium YALE CPVF 10-4 1,000 kg 400 V - 3ph+N+PE - 50 Hz Acc. to DIN EN ISO 14122

6/6 Technical Data Design parameter Material Medium Activatedcarbonreplacem.system Optional Number of chambers Diameter of the filter Activated carbon(working filter) Activated carbon (control filter) Nominal flow rate Max. flow rate Operating temperature Permissible operating pressure Max. operating pressure *1 Max. operating temperature Max. operating temperature *1 Pressurelossat max.vol. (in series) Pressurelossat max.vol. (in series) *1 Type of activated carbon TWIN-FAKA 3000K2 E TWIN-FAKA 6000K2 E TWIN-FAKA 7000K1 E Stainless steel Sewage gas / landfill gas Big Bag Crane 2 2 2 2 1 1 1,270 mm 1,270 mm 1,900 mm 1,900 mm 1,900 mm 1,900 mm 1,500 L 1,500 L 3,000 L 3,000 L 7,000 L 7,000 L 1,500 L 1,500 L 3,000 L 3,000 L 750 Nm³/h 1,400 Nm³/h 1,700 Nm³/h 900 Nm 3 /h 1,700 Nm 3 /h 2,000 Nm 3 /h 4 C to > -100 / < 300 mbar max. 160 mbar < 23 mbar < 18 mbar < 46 mbar < 36 mbar < 30 mbar < 60 mbar ACO sorb[si] Gas composition Methane CH 4 Carbon dioxide CO 2 Oxygen O 2 *2 Relative gas humidity *2 Relative gas humidity *3 Hydrocarbons C 5 Max. siloxanes Max. hydrogen sulphide H 2 S approx. 60 Vol.-% approx. 40 Vol.-% >0,5 & < 3 Vol.-% approx. 50-60% < 50-60 % < 100 mg/m 3 1,000 mg/m³ 1,000 ppm Physical properties Gas density Specific heat capacity C P approx. 1,2 kg/nm 3 approx. 1,6 kj/nm 3 K Installation conditions Installation site Permissible temperature Inlet/outlet Inlet height Dimensions in mm (L x W x H) Dimensions in mm with crane Empty weight Operating weight Type of insulation Type of crane Max. lifting weight Electrical connection Construction: platform/ladder *1: with deflagration flame arrester option *2: with optional H 2 S removal only *3: for siloxane removal Outdoors - 15 to + 35 C DN 200/200 PN10 2,200 mm 4,016 x 2,450 x 6,873 5,207 x 2,748 x 6,902 5,207 x 2,748 x 6,902 5,485 x 2,450 x 9,980 6,716 x 2,738 x 9,980 6,716 x 2,738 x 9,980 5,600 kg 6,900 kg 6,900 kg 10,600 kg 16,500 kg 18,100 kg 50 mm mineral wool / sheet aluminium YALE CPVF 10-4 1,000 kg 400 V - 3ph+N+PE - 50 Hz Acc. to DIN EN ISO 14122