Village of Sloan Smoke Testing September 2017

Similar documents
Brigitte A. Berger, Director of Engineering

Villas I at Snowden Overlook Condominium Suggested Home Maintenance Checklist July 27, 2018

INTENSIVE SMOKE TESTING SPECIFICATIONS & PROCEDURES

Guidelines for the Sanitary Sewer Evaluation Survey (SSES) Report PLAN A

Section 8 Housing Choice Voucher Program. Housing Quality Standards (HQS) Inspection Checklist

Green Infrastructure Implementation Planning for Multiple Objectives

A GUIDE TO THE ROCK ISLAND HOUSING CODE. Prepared By: The City of Rock Island Inspection Division

This Report Was Prepared For: Property Address Inspected:

Terry Building Inspection report summary with all items addressed or explained in red

The Ultimate Home Maintenance Schedule

PERFORMANCE SPECIFICATION GUIDELINE SMOKE TESTING

Renwick Neighborhood Association Inc., Springhouse Ridge Zone 1205 N. Walnut Street Bloomington, IN

PLUMBING INSTALLATIONS

PUBLIC WORKS FREQUENTLY ASKED QUESTIONS

Joseph Florio, Commissioner of Pub. Works Tel

Plugging Home Drains to Prevent Sewage Backup

Read Only Document Not For Distribution

Homeowners Guide to Stormwater BMP Maintenance

The Pressure Sewer System Owners Guide

CMHC HOME MAINTENANCE CHECKLIST

Level I Chapter 1 Worksheet

Minor Home Repairs. November 4, County of Henrico Department of Community Revitalization

FRUCHTMAN & ASSOCIATES

Town of Sturbridge Grinder Pump Policy Homeowner s Guide to Grinder Pumps

El 0. El 0. El El. El El. El 0 TWO FAMILY HOUSING INSPECTINO CHECKLIST

Asurity 1. Property Inspection Report S Gurd Rd., Hastings, MI Inspection prepared for: Beretta Lenos Real Estate Agent: Stan Labinski -

SUMMER. Over the summer, there are a number of indoor. Inspecting your home on a regular basis and. Seasonal Maintenance Schedule. For A Healthy Home

Home Maintenance Schedule

WATER DAMAGE - FREQUENCY. July 6, 2017

20/20 Home Inspections. Photo Attachments

While most maintenance is seasonal, there are some things you should do on a frequent basis year-round:

ICP Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer.

Best Environmental Management Practices

plumbing for greywater

Montgomery County Land Bank PRE SALE INSPECTION REPORT

Welcome! Today s topic: Small Home Repairs. November 14, 2015

I. Best Management Practices (BMPs) to Prevent Blockages in the Sanitary Sewer System

Plumber Level 3 Rev. May 2011

I. STRUCTURAL SYSTEMS

LEAK GUIDE HOW TO IDENTIFY COMMON PLUMBING LEAKS

Is Sewer Gas Giving Your Customers the Wrong Impression?

Home Inspection Report

SOLUTION TO STORMWATER POLLUTION!

Don t let a flood wash away what s important to you. Tips and advice to protect you, your family and your home: before, during and after a flood.

Summary of Conversion Steps. 1. Obtain the abandonment/conversion permit from the Department of Health.

Operation & Maintenance of Stormwater Management Facilities

TOWN OF TICONDEROGA WATER DEPARTMENT WINTER WEATHER PROBLEMS

Troy's Home Inspection Services LLC

Certificate of Inspection CHECKLIST

Cistern Connections. Overview: Active rainwater collection systems can be comprised of a few simple and inexpensive components.

GARCIA GALUSKA DESOUSA Consulting Engineers

Plumbing System. Important Information. Shut-Off Valves

CHAPTER VI BUILDING PLUMBING

Inspection Report. Prepared for: Tonia Mann. Property Address: 402 Leslie Court McDonough, GA Date: March 07, 2013

Montgomery County Land Bank 130 West 2nd Street, Suite 1425 Dayton, OH PRE SALE INSPECTION REPORT

Keeping. Fats, Oils, and. Grease. Out of the Sewer

Montgomery County Land Bank 130 West 2nd Street, Suite 1425 Dayton, OH PRE SALE INSPECTION REPORT

MATERIALS Traps TRAPS. No. IPC IRC Description

Eveready Flood Control Frequently Asked Questions

The following information will explain the plumbing components and warranty coverage for the plumbing systems and fixtures in your new house.

ce Is the Key Seasonal Home Maintenance Inspecting help keep live. help you. person to round: snow or debris. test button, which should then cause the

September 22, IDDE & Storm Drain Maintenance Requirements Steve Teravskis, WGR Southwest, Inc.

Tips for Maintaining and Enhancing Stormwater Management Areas

Pipe Sizing Table. Hydraulic Load Served (fixture units)

Sewer & Storm Drain Systems

SUMMARY 1234 Main St.Edmonton AB T5T3E9 Buyer Name 07/05/2018 9:00AM

SUMMARY 1234 Main St.Severn Buyer Name 07/18/2018 9:00AM

portable heater FAN Set up and Operating Instructions

INFLOW & INFILTRATION REPORT

Home Set-up and Maintenance. Maintenance

Extra Mile Inspection, Inc.

2009 IPC ,IMC Q &A ANDIFGC

EVAPOCYCLE OWNERS MANUAL

STORM SEWER TELEVISING REPORT FOR HARRIS COUNTY WATER CONTROL AND IMPROVEMENT DISTRICT NO. 50 HARRIS COUNTY, TEXAS TABLE OF CONTENTS

ITEMS NEEDING ACTION

SEASONAL MAINTENANCE SCHEDULE

APPENDIX J ILLUSTRATIONS

Your Pressure Sewer System. A Homeowner s Guide

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

Residential * Commercial * Mobile Homes * New Construction

Preventing Storm Water Pollution

New State Storm Water Rules: WHAT MUNICIPALITIES NEED TO KNOW &

Montgomery County Land Bank 130 West 2nd Street, Suite 1425 Dayton, OH PRE SALE INSPECTION REPORT

Beau s Emergency Response Plan

WEF Collection Systems Conference 2017

Preventing Storm Water Pollution

Read Only Document Not For Distribution

REGISTRATION EXAMINATION, JUNE 2015 LICENSED PLUMBER QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

PRESSURE SEWER SYSTEMS GUIDE FOR HOME OWNERS AND BUILDERS

City of Petersburg, Virginia Stormwater Utility Program Residential Fee Credit Manual (Revised March 2014)

Boston Water and Sewer Commission

Grinder Pump Information

Montgomery County Land Bank 130 West 2nd Street, Suite 1425 Dayton, OH PRE SALE INSPECTION REPORT

Best Management Practices (BMPs)

Doyle Home Inspections

Land Use and Environmental Service Agency (Code Enforcement) Plumbing 2010

Grease Control Device Maintenance Recordkeeping

BE WATER WISE Rainwater Conservation

2015 UPC Chapter 8 Indirect Wastes RV

Bay Wide Commercial and Home Inspection Thackeray Avenue/ Mail address Hayward, Calif TH AVENUE SAN LEANDRO, CALIFORNIA

Transcription:

Village of Sloan Smoke Testing September 2017 What is Smoke Testing? Smoke testing is used to detect any water other than wastewater entering the sanitary sewer system. This water could be coming from roof leaders, cross connections between the wastewater and stormwater systems, cleanouts, driveway and yard drains, damage to the wastewater system, loose joints in the wastewater pipes, etc. Smoke testing is an inexpensive and effective way to quickly identify inflow sources. Inflow can lead to sanitary sewer overflows (SSOs), which the Village needs to eliminate due to a NYS Department of Environmental Conservation Order on Consent and because they are bad for the environment. Where smoke can come up from the sewer How does Smoke Testing Work? Crews position a blower at a sanitary manhole and blow smoke down into it. The smoke then travels down the sewer. If there are any openings along the way, some of the smoke will escape through the opening. Smoke may appear to be coming from holes in the ground or vent stacks on houses. Smoke coming from vents in house roof

After blowing smoke into the line, the crew will look to see where smoke is escaping. Locations where smoke is coming from are identified with a white board and photographed. Smoke coming from ground from damaged lateral Smoke coming from storm drain cross connection

Is the Smoke Dangerous? The smoke used has a slight odor and is not hazardous, toxic, or flammable. It is manufactured specifically for this purpose. The smoke may make you cough, but it is not harmful to your health. The smoke will not harm clothing, drapes, or furniture. The smoke is also not harmful to your pets or plants. Smoke that gets in buildings dissipates quickly and leaves no residue or stains. In the cases listed above, there is also a potential for sewer gas to enter the residence. Immediate action should be taken on the part of the homeowner to repair the problem. Residential Notification Before we smoke test the sanitary sewer system, we will notify residents of the dates we will be testing. Please read below to see what you should do prior to the start of the smoke testing. Important Instructions for Residents Prior to Smoke Testing: When you are notified that smoke testing is going to occur in your neighborhood you should make sure that all traps under basins (including garage sinks), washing facilities, and floor drains have water in them. This can be done by pouring at least one gallon of water in them or running the faucet for at least 60 seconds. This will help prevent smoke from entering your home. If you have pets and are not going to be home when smoke testing is being conducted, it would be a good idea to leave several windows partially open for ventilation, should any smoke enter the building. If smoke gets into the house, contact the smoke testing crew or call the Village at (716) 897-1560. Open your windows and doors for ventilation and the smoke will soon dissipate. Smoke should not enter your house. If it does, it will be an indication of a defect in your plumbing. This defect could allow sewer gases to enter your house. Sewer gases can be a health hazard. The correction of these defects in your plumbing is the responsibility of the homeowner. A licensed plumber should be consulted to make the corrections properly.

Smoke Testing Results After Smoke Testing, the Engineer will review the results of the smoke testing and determine what work needs to be done to the Village system to eliminate these smoke sources. Work could include adding cleanout caps, repairing or replacing laterals, or repairing or replacing sewer mains. Smoke sources on private property will be turned over to the Village Code Enforcement Officer who will visit the homeowner and make them aware of these sources, and their responsibility to correct them. The Village will follow up with a letter explaining the problem. The Inspector will give a date when the smoke defect needs to be corrected by. Some corrections are easy to complete and could possibly be accomplished by the homeowner, such as disconnecting roof leaders or down spouts from the sanitary lateral or replacing cleanout cap that is broken or missing. Smoke coming from Roof Leader The Village may give the homeowner more time to correct more difficult corrections that require a licensed plumber. These corrections could include laterals that are cracked or have been invaded by tree roots, or rerouting of drainage. Fixing defects benefits everyone. It prevents SSOs, saving the Village and ultimately the sewer user from paying fines, and it is better for the environment.

Correcting I/I Sources from your Property Cleanout Caps Cleanout caps that are not sealed tight, cracked or broken, or missing can allow stormwater into the sewer system. Cleanout caps are easy to change. Cleanout caps can be purchased at your local hardware store. Smoke coming out of Cleanout missing a cap

Roof Leaders Roof leaders connected to the sewer system can add as much as 800 gallons of stormwater to the sewer system in a one inch rain event. This connection to the sewer system must be disconnected to prevent SSOs from occurring. Disconnection is easy. Cut the downspout. Insert horizontal spout out five feet away from the house. Plug the ground pipe. Roof Leader disconnect from sewer system; Former connection to sewer system plugged

Ground There is a possibility of a broken private sewer lateral where smoke comes up from the ground. These breaks can range from root intrusion, to a cracked portion of pipe or misaligned joints or an offset section of pipe. These can cause the lateral to plug or collapse. This would cause a sewer backup in your house. A licensed sewer contractor can televise your sewer lateral to see exactly where the problems exist. Smoke coming up through ground from private lateral