Hydraulic Installation

Similar documents
Why Vaillant? Because the ecotec delivers day in, day out. Vaillant ecotec boiler range. The TECHNICAL Brochure

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

Introduction...from 3 to 4 Tanks for the production and storage of DHW. Domestic use....from to 8 Tanks for the production and storage of DHW. Industr

extreme HIGH EFFICIENCY HOT WATER SYSTEMS

Broag Pressurisation equipment

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

ADVANCE UNIVERSAL MULTI-FUEL THERMAL STORE

Extreme Domestic Hot Water Loading System TECHNICAL DOCUMENTATION. Issue 11/09

Unvented Hot Water Criteria

Technical and Installation manual All Models

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Advance Stainless Steel Unvented Hot Water Cylinders for Heat Pump Systems. Installation and Commissioning Manual

Multipoint Technical Data

Components for solar heating systems

Unvented Direct & Indirect Hot Water Cylinders (400L L)

INSTALLATION MANUAL. RD SERIES Digital Electric Water Heater Wall-hung Unvented

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

Introduction. There is no obligation to follow the methods or comply with the standards set out in this Technical Booklet.

Schuco SS-TC/SC Cylinders

Unvented Direct & Indirect Hot Water Cylinders (400L L)

FASTflo. Working towards a cleaner future

SEALED THERMAL STORE

UNIQ HEAT BATTERIES REFERENCE MANUAL_V2.2. Version: 2018_07_19_v2.2

KYROS INSTALLATION MANUAL KYROS. Digital Electric Water Heater Wall-hung Unvented

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Installation and User Instructions Aquaheat Unvented Water Heaters Models: AH30H

ADVANCE STAINLESS STEEL UNVENTED HOT WATER SYSTEMS

H o t Wa te r Syste m s. Ultrasteel. Unvented Hot Water Cylinders. Exceeding the Standard

Exceeding the Standard

Exceeding the Standard

HYDRONIC SPECIALTIES TACO MPT Tank(s) 05/30/2012. A. Multi-Purpose Tank buffer tank, air separator, and hydraulic decoupler

Installation, Operating and Servicing Instructions

Pivot Stove Hydronic Installation Guide

TABLE OF CONTENTS TECHNICAL DOCUMENTATION 03. Technical Data Electrical Details Connection Details Dimensions Standing Losses

This manual must be kept with the appliance

Quantum. Installation, User and Service Manual. Hot Spring

Megaflo Eco Unvented Direct & Indirect Hot Water Cylinders

PremierPlus. and PremierPlus SystemFit. Direct and Indirect Unvented Water Heating. Unvented Water Heaters

Commercial Indirect / Multi Energy / Solar Unvented Water Heaters Installation & Maintenance Manual

Installation Manual EXCELSIOR Unvented Water Heater

Furrows Business Park, Haybridge Road Wellington, Telford, Shropshire TF1 2FE

ZIP Varipoint III. Installation, Maintenance and User Instructions. Models VP303, VP503 VP803, VP953 direct unvented water heaters. Issued August 2008

Installation, Operating and Servicing Instructions

Plus. USER and INSTALLATION INSTRUCTIONS. 30,000-9kW for Heating and Hot Water

UK arotherm Schematics and installation guide

ELECTRIC COMBINATION BOILER. (European Patent No: Design Right Protected.) TH12-450U MRK 2

Link-Up. Solid Fuel Association Guide to Central Heating.

STAINLESSLITE PLUS ONE NAME. EVERY SOLUTION. UNVENTED MAINS PRESSURE AND VENTED WATER STORAGE CYLINDERS

AquaFlo II. Issue 3 December Please read these instructions carefully before commencing installation of the AquaFlo unvented water heater

Megaflo Eco Plus Unvented Indirect Hot Water Cylinders 800L L

STAINLESSLITE PLUS ONE NAME. EVERY SOLUTION. UNVENTED MAINS PRESSURE AND VENTED WATER STORAGE CYLINDERS

the electric heating company ELECTRIC BOILER HANDBOOK

INTRODUCTION STORAGE PRIOR TO INSTALLATION. Expansion Vessel Hose. Part No High Flow Rate Inlet Control Set. Part No.

Hamworthy. Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters. Exceeds Minimum Requirements

Installation, Operation and Maintenance Instructions for Electric Storage Calorifier

Installation, Operation and Maintenance Instructions for Thermax Semi-Storage Calorifier

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION. For Super SXD, SX, SCI & SC

Cylinders for Domestic Purposes Heat Pumps

PremierPlus Unvented Hot Water Cylinder Installation and User Manual

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

MW & EW 10 & 15 Litre Unvented Water Heaters HANDBOOK. IMPORTANT: This booklet should be given to the customer after installation and demonstration.

MAX O GAZ. Condensing water heater TECHNICAL MANUAL

S T O R E R A N G E C Y L I N D E R & G R A N T FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS

Assessment Schedule - TS.6

Unvented Electric Water Heater 10/15 litre Undersink

Unvented Water Heating. Zircon

Megaflo Eco SystemReady Unvented Indirect Hot Water Cylinders

Vented and Unvented Hot Water Systems

Installation & User Instructions

Metropolitan. Steam Boiler. Suitable for Pressure Jet or Rotary Cup burners Oil, gas or dual fuel firing. Outputs kg/h

Instructions for Use Installation and Servicing

WATER HEATERS INSTALLATION MANUAL

Re n ewa b l e s. Tribune HE. Unvented Hot Water Cylinders. Making Life Simpler

Megaflo Eco Unvented Direct & Indirect Solar Hot Water Cylinders

Water Heating UK 14 th May 2016

MEGAFLO Eco Plus Solar Unvented Hot Water Cylinders 400L -570L

H o t Wa te r Syste m s. Tribune HE Unvented Hot Water Cylinders. Making Life Simpler

Megaflo Eco Solar PV Ready Unvented Direct & Indirect Hot Water Cylinders 170L - 300L

Instructions & Maintenance

T E C H C A L EBS-1 T High technology heating

H o t Wa te r Syste m s. Tribune HE. Unvented Hot Water Cylinders. Making Life Simpler

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

H o t Wa te r Syste m s. Tribune HE Unvented Hot Water Cylinders. Making Life Simpler

aurostor Installation and maintenance instructions Installation and maintenance instructions For the competent person GB, IE VIH S GB...

Powerstock Storage Tank

1845 Tech Manual.qxd 23/11/05 1:20 pm Page 2 EXCELSIOR UNVENTED WATER HEATERS INSTALLATION MANUAL. Design for living

ZIP AquaFlo II. Models: Direct, Indirect and Solar Compatible. Unvented cylinder water heaters

HYDRONIC SPECIALTIES TACO AC(F)-CA 05/08/2008

Savile Plus. Steam Boiler. Suitable for Pressure Jet burners Oil, gas or dual fuel firing. Outputs kg/h

Design, Installation, User & Servicing Instructions

HOTFLO 10 / 15. Fitting Instructions and User Guide

UN-VENTED & VENTED STAINLESS STEEL HOT WATER CYLINDERS

Efficiency Maximiser for Solid Fuel Central Heating

THERMAL STORE MAINS PRESSURE SYSTEM

Installation and User Instructions HS10U, HS15U.

VIESMANN. Installation instructions VITOCELL 300-B. for contractors. Vitocell 300-B Type EVBA-A. Dual mode DHW cylinder, 300 and 500 l

Installation, operation and care. Pellmax UB. Burner not included Replaces:

Design, Installation & Servicing Instructions

STAINLESSLITE ONE NAME. EVERY SOLUTION. UNVENTED MAINS PRESSURE AND VENTED WATER STORAGE CYLINDERS

Transcription:

General Norms - The safety system should be added directly to the domestic water installation. - A pressure-limiting device must be fitted in the installation. The rated pressure of the safety valve must be < 0. MPa ( bar, bar for inertia tanks). - If mains pressure is greater than 0. MPa ( bar, bar for inertia tanks), the installation of a pressure reducer is recommended to avoid exceeding the assigned pressure by more than 0. MPa (bar). - In tanks with primary circuit (tank in tank system or coil), this will must be equipped with a safety valve. - It is normal for water to be discharged during heating (expansion). The volume discharged may be up to % of the capacity of the storage tank. - Depending on the quality of the water, the pressure-regulating device should be regularly operated in order to remove lime deposits and to ensure that it is not blocked. - Water may drip out of the discharge pipe of the pressure-regulating device. This pipe should be exposed to the open atmosphere in frost-free environment and in a constant downward sloping direction. - Fit dielectric bushings at the inlet and outlet pipes at the tank connections. - Purge air from circuits once they have filled with water. The domestic can be purged by opening a hot outlet at the highest point. - To avoid ram blows in the installation caused normally by "all-none" hydraulic opening elements (electrically-operated-valve in steam warming systems, pressure kits, etc..) To avoid ram blows in the installation caused normally by "all-none" hydraulic opening elements (electrically-operated-valve in steam warming systems, pressure kits, etc..) - See additional information in the installation manual of each model. NOTE: Expansion Vessel or Vessels must be fitted in the primary (heating) circuit. This Vessel or Vessels must be sized correctly to accommodate the total water expansion capacity of the primary water in the tank and all relevant circuits. Kits for unvented installation TANK MODEL KIT UNVENTED KIT COMPOSITION GX00/00P I, GX00/00PAC I, GX0/00D I, GX-0/0-D I, GX-0-D I KIT.0/.0 BAR INLET GROUP MM X MM TUNDISH. LTR POTABLE VESSEL C/W BRACKET CONNECTION HOSE FOR ABOVE. MM ZONE VALVE MM ZONE VALVE GX00/00P I, GX00PAC I, GX-00-D I, GX-0/00-D I, GX-0/00-D I, GX00R I/M I/M I KIT.0/.0 BAR INLET GROUP MM X MM TUNDISH. LTR POTABLE VESSEL C/W BRACKET CONNECTION HOSE FOR ABOVE. MM ZONE VALVE MM ZONE VALVE GX000P I, GX-00-D I, GX-00-D I, GX00R I/M I/M I KIT.0/.0 BAR INLET GROUP MM X MM TUNDISH. LTR POTABLE VESSEL C/W BRACKET CONNECTION HOSE FOR ABOVE. MM ZONE VALVE MM ZONE VALVE GX00D I / GX00D I, GX00R I/M I/M I KIT.0/.0 BAR INLET GROUP MM X MM TUNDISH 0 LTR POTABLE VESSEL C/W BRACKET MM ZONE VALVE MM ZONE VALVE GX-00-R I/M I/M I KIT.X.0 BAR INLET GROUP 0L VESSEL ZONE VALVE GX-000-R I/M I/M I KIT.X.0 BAR INLET GROUP 00L VESSEL ZONE VALVE P&T relief valve Nominal set pressure: bar Nominal size P&T relief valve / -/ Discharge flow rate, l/h 0 0 Discharge power rate, KW*.. *Discharge power rate is calculated with a secondary temperature increase of 0 ºC. Please, fix the P&T relief valve to your installation conditions Installation examples The hydraulic squemes shown in this technical catalogue are only instalation examples and are not mandatory. The installation and all the elements included must be planned by the installator under his responsability. Cold Feed Secondary Pump Flow From GX-DI / GX-DI / GX-DI: Typical single calorifier open vented application Drainat Low Level DOC Return to

GX-DI / GX-DI / GX-DI: Typical single calorifier unvented application Pressure Limiting with Integral Strainer Set. bar Expansion Relief Set.0 bar Insolation Optional secondary return Secondary Pump Balanced Pressure Cold Water Take Of If required Stop Cold Supply Core Assembly with Integral Non-Return Flow from Expansion Vessel Port Spring Return Motorised P & T Relief Hot oulets Drainat Low Level GX-DI / GX-DI / GX-DI: Typical multiple calorifier open vented application DOC Return to Open Vent Secondary Pump Cold Feed Flow From Port Divertor (Temperature Control) Flow Regulator Return to GX-DI / GX-DI / GX-DI: typical multiple calorifiers unvented-direct-on-mains/boosted supply application Cold Supply Expansion Vessel Optional secondary return Stop Pressure Control with Strainer Secondary Pump Balanced Pressure Cold Water Take Off If Required Flowfrom Spring Return Motorised Motorised (Unvented Kit) Port Divertor (Temperature Control) Expansion P & T Relief P & T Relief valve Flow Regulator Return to

Typical single tank open vented application. Multifunctional GX-00/00/000-P I tanks with heating coil. Example of Solar, ASH and boiler connection - Port Spring Return Motorised - Adjustable By-pass (contact the ASH pump manufacturer) - Primary pump - Shut-off valve - Purger / drain valve - External sensor - Electric heater - Sieve filter for ASH Pump 0 - Pump - - Drainat low level - Safety valve - Emptying / Drain - Expansion Vessel - Heating coil Typical single tank open vented application. Multifunctional tanks without heating coil GX-00/00/00-PAC I. Example of Gas / Oil boiler and ASH pump connection DOC Radiant floor 0 Gas/Oil boiler Heating emptying of the tank, that cut - Port Spring Return Motorised - Adjustable By-pass (contact the ASH pump manufacturer) - Primary pump - Shut-off valve - Tank sensor (primary circuit) - External sensor - Electric heater - Sieve filter for ASH pump 0 - Pump - - Drainat low level - Expansion vessel 0 Gas / Oil boiler (boiler) (boiler) DOC emptying of the tank, that cut Typical single tank open vented application. Multifunctional tanks without heating coil GX-00/00/00-PAC I. Example of ASH pump connection emptying of the tank, that cut key is placed lower than the storage tank, helping the outlet (radiant floor) 0 - Port Spring Return Motorised - Adjustable By-pass (contact the ASH pump manufacturer) - Primary pump - Shut-off valve - Tank sensor (primary circuit) - External sensor - Electric heater - Sieve filter for ASH pump 0 - Pump - - Drainat low level - Safety valve - Emptying / Drain - Expansion Vessel - Purger / Drain valve Radiant floor Heating (radiant floor) (heating) (heating)

Typical single tank unvented-direct-on-mains/boosted suppy application. Multifunctional tanks GX-00/00/000-P I with heating coil. Example of Solar, Gas boiler and Oil boiler connection 0 DOC emptying of the tank, that cut - Port Spring Return Motorised - Adjustable By-pass (contact the ASH pump manufacturer) - Primary pump - Shut-off valve - Purger / drain valve - External sensor - Electric heater - Sieve filter for ASH Pump 0 - Pump - - Drainat low level - Safety valve - Emptying / Drain - Expansion Vessel - Heating coil - Core Amsembly with integral Non-return valve - P&T relief valve - Pressure limiting with Integral Strainer Set. bar Typical single tank unvented-direct-on-mains/boosted suppy application. Multifunctional tanks without heating coil GX-00/00/00-PAC I. Example of Gas / Oil boiler and ASH pump connection emptying of the tank, that cut 0 (boiler) DOC Gas / Oil boiler (boiler) - Port Spring Return Motorised - Adjustable By-pass (contact the ASH pump manufacturer) - Primary pump - Shut-off valve - Tank sensor (primary) - External sensor - Electric heater - Sieve filter for ASH Pump 0 - Pump - - Drainat low level - Expansion Vessel - Core Amsembly with integral Non-return valve - P&T relief valve - Pressure limiting with Integral Strainer Set. bar

Typical single tank unvented-direct-on-mains/boosted suppy application. Multifunctional tanks without heating coil GX-00/00/00-PAC I. Example of ASH pump connection emptying of the tank, that cut 0 (radiant floor) Radiant floor Heating (radiant floor) (heating) (heating) - Port Spring Return Motorised - Adjustable By-pass (contac the ASH pump manufacturer) - Primary pump - Shut-off valve - Tank sensor (primary) - External sensor - Electric heater - Sieve filter for ASH Pump 0 - Pump - -Drainat low level -Safety valve -Emptying / Drain -Expansion Vessel -Pressure limiting with Integral Strainer Set. bar -Core Amsembly with integral Non-return valve -P&T relief valve -Purger / Drain valve Example of typical single tank open vented application. Multifunctional tanks GX-00/00-P I litres with heating coil. Example of Solar and ASH pump connection emptying of the tank, that cut Open vent 0 to Radiators from Radiators RADIATORS - Port Spring ReturnMotorised - Adjustable By-pass (contact the ASH pump manufacturer) - Primary pump - Shut-off valve - Purger / drain valve - External sensor - Electric heater - Sieve filter for ASH Pump 0 - Pump - - Drainat low level - Safety valve - Emptying / Drain - Expansion Vessel - Heating coil 0

Example of typical single tank unvented-direct-on-mains/boosted suppy application. Multifunctional tanks GX-00/00-P I litres with heating coil. Example of Solar and ASH Pump connection emptying of the tank, that cut 0 RADIATORS to Radiators from Radiators - Port Spring Return Motorised - Adjustable By-pass (contact the ASH pump manufacturer) - Primary pump - Shut-off valve - Purger / drain valve - External sensor - Electric heater - Sieve filter for ASH Pump 0 - Pump - - Drainat low level - Safety valve - Emptying / Drain - Expansion Vessel - Heating coil - Core Amsembly with integral Non-return valve - P&T relief valve - Pressure limiting with Integral Strainer Set. bar GX-R/RB: Vertical buffer tank without coils Plate heat exchanger Mains water intake feed return - Safety Group - One-way valve - Circulator - pump - Shutoff cock - Drain - P&T relief valve

GX-M/MB: Vertical tank with one coil 0 feed return Mains water intake - Safety Group - One-way valve - Circulator - pump - Shutoff cock - Drain - Safety - Coil - Expansion Vessel 0 - P&T relief valve GX-M/MB: Vertical tank with two coils 0 flow Solar flow Solar return Mains water intake return 0 - Safety Group - One-way valve - Circulator - pump - Shutoff cock - Drain - Drain - Coil - Safety 0 - Expansion Vessel - P&T relief valve