air/water heat pump. NIBE F2040 provides

Similar documents
Air/water heat pump NIBE F2120

NIBE F2120 Air/water heat pump

NIBE SPLIT HBS 05 Air/water heat pump

NIBE SPLIT ACVM 270 Air/water heat pump

NIBE F2026 air/water heat pump. fresh air s free. NIBE F2026. Efficient scroll compressor that operates at temperatures down to -20 C.

NIBE F1355. A +++ The system's efficiency class for heating. Speed-controlled ground source heat pump for large buildings. Ground source heat pump

Ground source heat pump NIBE F1255

NIBE F470 A + Complete heat pump unit that provides heating, hot water, ventilation, heated supply air and heat recovery. Exhaust air heat pump

Installer manual NIBE F , 12, 16 kw UK 1x230V Air/water heat pump IHB GB LEK LEK LEK

NIBE F750 A +++ Flexible, high-performance exhaust air heat pump. Exhaust air heat pump

NIBE VVM 300. Intelligent hot water NIBE VVM 300. VVM 300 is designed for connection and communication

User manual NIBE F2026

Air/water heat pump NIBE F2120 8, 12, 16, 20

Teknik Data NIBE F2120 8, 12, 16, 20

Installer manual ELK 213 Immersion heater

User manual JÄSPI Inverter Nordic 8, 12, 16, 20

Planning guide. Atec.

INSTALLATION AND MAINTENANCE INSTRUCTIONS F F2025

Installer manual AG-AA10. Air/air heat pump IHB GB AG-AA10-30 AG-AA10-40/50

User manual. JASPI COMFORT MONO 8 & 12Kw UK 1x230V. Air/water heat pump LEK

NIBE VVM 500 FLEXIBLE INDOOR MODULE INTELLIGENT HOT WATER NIBE VVM 500. Flexible all-in-one indoor module for heating and hot water.

Installer manual AXC 30

Installer manual SMO 40

Installer manual NIBE VVM 310

Installer manual NIBE VVM 500

INSTALLATION AND MAINTENANCE INSTRUCTIONS AMB AMB 30 LEK

Installer manual AMS 10

Technical description. Atec.

Installer manual NIBE F2120

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

Installer manual SMO 40

Swedish design and manufacture since 1967

HT V2 HT Split

Advance Split

Air/water - Heat pumps

NIBE F1245 GROUND SOURCE HEAT PUMP. Heat pump with rock, ground or lake as heat source. NIBE F1245

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

12 Technicaldata. Dimensions and setting-out coordinates 25-50

Installer manual NIBE F730

Operating instructions Page 6

Outline principle. Application Buildings with water-borne heating systems. Alternative

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

Outline principle. Application Houses with water-borne heating systems. Alternative Select the desired configuration by highlighting the boxes below.

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

Original instructions AR

Outline principle. Application Buildings with water-borne heating systems. Alternative

Installer manual SMO 40

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

DHP-H Varius Pro+/DHP-L Varius Pro+

Installer manual AXC 40. Accessories IHB GB LEK

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

Outline principle. Application Houses with water-borne heating systems. Maximal recommended heating output 13.5 kw. Alternative

Technical data LA 60TUR+

High temperature air-to-water heat pumps

Technical specifications

50A KP 70A KP 90A KP 120A KP 150A KP 210A

Instruction manual Harmo PAC ZVWX1017/1022/1032/1041/1055/1056/1061

MOS GB SMO INSTALLATION AND MAINTENANCE INSTRUCTIONS NIBE SMO 10

Operating instructions Page 14. Refrigerator Read the operating instructions before switching on for the first time

Technical data LA 28TBS

Installation instructions for condenser tumble dryer DOMESTIC. Dear Customer,

Bosch Product Reference Guide. bosch-climate.co.nz

Technical data LA 9S-TU

Technical Data. Danfoss DHP-C. Provides heating, cooling and hot water TWS technology provides hot water quickly with low operating

Technical data. Danfoss DHP-A

Technical data. Danfoss DHP-L

LS Condensate Removal Pump INSTRUCTION MANUAL REVISION A

MOS GB SMO INSTALLATION AND MAINTENANCE INSTRUCTIONS NIBE SMO 10

USER MANUAL SILENT16 PORTABLE AIR CONDITIONER

HYDRONIC RESIDENTIAL

Operating instructions Page 12

AGEO CALEO. Water-to-water high temperature heat pumps USE RANGE DESCRIPTION. Designed to replace a conventional boiler and produce domestic hot water

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

WHY A MHI HEAT PUMP?

PRODUCT DATA COMFORT 1200 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 1400 m 3 /h

Installer manual SMO 20

Efficient heating that won t cost the earth

Technical data LA 60TU

COMPACT PORTABLE AIR CONDITIONER USER MANUAL

Installation, operation and care Wall-mounted electric boiler MP THL nr. - rev 02

MAKING MODERN LIVING POSSIBLE. Technical description DHP-M.

SILENT 12 PORTABLE AIR CONDITIONER USER MANUAL

Technical Guide. Installation, Operation and Care. EP E series 7 step electric boilers 26 and 42 kw

NIBE IT S IN OUR NATURE

EH0533 Indoor Climate Control

INSTALLATION AND MAINTENANCE INSTRUCTIONS MOS GB NIBE VVM 300 UK NIBE VVM 300 UK 230 V VVM 300 LEK

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY

Removing shipping locks

EH0554 Indoor Climate Control

Installer manual AG-WL10

HPWH 300 HPWH 300HE. Installation and Operating Instructions. Hot Water Heat Pump for Outdoor Installation. English FD 9501

NIBE SPLIT ACVM 270, AMS 10

PUHZ-SHW140YHA PUHZ-SHW230YKA

MOS GB NIBE VVM INSTALLATION AND MAINTENANCE INSTRUCTIONS NIBE VVM 300 VVM 300 LEK

BWL air heat pumps BWS brine heat pumps

Installation instructions Danfoss heat pump DHP-R

Transcription:

NIBE.EU Air/water heat pump NIBE F2040 NIBE F2040 is an intelligent and compact invertercontrolled air/water heat pump. NIBE F2040 provides optimum savings since the heat pump automatically adapts to your home s output requirements all year round. The heat pump works down to an outdoor temperature of -20 C and at the same time supplies up to 58 C in supply line temperature. The effective cooling function allows the heat pump to deliver a comfortable indoor climate even at high outdoor temperatures.. Thanks to smart technology, the product gives you control over your energy consumption and will be a key part of your connected home. The efficient control system automatically adjusts the indoor climate for maximum comfort, and you do nature a favour at the same time. Compact heat pump that adapts to your home s requirements. High capacity even down to -20 C and effective cooling function. Energy-saving smart technology with user-friendly control.

This is how NIBE F2040 works Installation method F2040 a part of your climate system where F2040 is intended to be combined with one of the indoor modules VVM or the control modules SMO. Together with an indoor module, F2040 creates a complete heating/cooling and hot water unit. Our flexible indoor modules provide efficient heating and high hot water performance. VVM indoor modules are complete with a smart and user-friendly control system, hot water heater, additional heat, self-regulating circulation pump, etc. The control modules, SMO, offer a flexible system solution that can be easily customised. For systems with SMO, different components such as water heaters, additional heat and other accessories can be selected to suit the installation's requirements. Up to eight F2040 can be connected to a SMO 40. There is a wide range of system solutions and accessories for NIBE's indoor modules and control modules. 2 NIBE F2040

UN VVM 225 APH APH IT'S IN OUR NATURE COMPATIBLE INDOOR MODULES (VVM) AND CONTROL MODULES (SMO) VVM 310 VVM 320 VVM 500 SMO 20 SMO 40 F2040-6 F2040-8 F2040-12 F2040-16 INDOOR MODULES CONTROL MODULES VVM 310 VVM 310 SMO 20 Part no. 069 430 With integrated EMK 310 Control module Part no. 067 224 Part no. 069 084 VVM 320 VVM 320 Stainless steel, 1x230 V Stainless steel, 3x230 V SMO 40 Part no. 069 111 Part no. 069 113 Control module Part no. 067 225 VVM 320 Enamel, 3x400 V With integrated EMK 300 Part no. 069 110 VVM 320 Stainless steel, 3x400 V Part no. 069 109 VVM 320 Copper, 3x400 V Part no. 069 108 VVM 500 Part no. 069 400 NIBE F2040 3

Principle of operation Principle of operation with hot water and a heating system. The heating medium side and the domestic hot water side must be fitted with the necessary safety equipment in accordance with the applicable regulations. EPLANATION EB15 Indoor module (VVM 320) EB101 FL10 QM1 QM40 QZ2 L1 L2 Heat pump (F2040) Safety valve, heat pump Tapping valve Shut-off valve Filterball Connection, heating medium out of F2040 Connection, heating medium in to F2040, -EB15 -EB101 -QM40 -L1 -QZ2 -L2 -QM1 -FL10 4 NIBE F2040

Good to know about NIBE F2040 Transport and storage F2040 must be transported and stored vertically. Installation and positioning Min. 300 minmm 300 mm Place F2040 outdoors on a solid level base that can take the weight, preferably a concrete foundation. If concrete slabs are used they must rest on asphalt or shingle. Do not place F2040 directly on the lawn or other non solid surface. The concrete foundation or slabs must be positioned so that the lower edge of the evaporator is at the level of the average local snow depth, although a minimum of 300 mm. The F2040 should not be positioned next to sensitive walls, for example, next to a bedroom. Also ensure that the placement does not inconvenience the neighbours. F2040 must not be placed so that recirculation of the outdoor air can occur. This causes lower output and impaired efficiency. The evaporator should be sheltered from direct wind, which negatively affects the defrosting function. Place F2040 protected from wind against the evaporator. Large amounts of condensation water, as well as melt water from defrosting, may be produced. Use the accessory KVR 10, see page 7. Care must be exercised so that the heat pump is not scratched during installation. If there is a risk of snow slip from roof, a protective roof or cover must be erected to protect the heat pump, pipes and wiring. NIBE F2040 5

IT'S IN OUR NATURE Supplied components Local differences in the enclosed kit may occur. See relevant installer manual for more information. 2 x flexible pipes (DN25, G1") with 4 x gaskets. Filterball (G1"). Installation area The distance between F2040 and the house wall must be at least 150 mm. Clearance in front of F2040 should be at least one metre. Free Fritt space 150 mm utrymme behind bakom 150 mm 400 mm 600 mm 400 mm 600mm Minimalt fritt utrymme Minimum free space Free space in front 3000 mm Fritt utrymme framför 3000 mm Minimalt fritt utrymme Minimum free space 6 NIBE F2040

Installation Inspection of the installation Current regulations require the heating installation to be inspected before it is commissioned. The inspection must be carried out by a suitably qualified person and should be documented. The above applies to closed heating systems. If the heat pump is replaced, the installation must be inspected again. Condensation water trough The condensation water trough collects and leads away most of the condensation water from the heat pump. It is important to the heat pump function that condensation water is led away and that the drain for the condensation water run off is not positioned so that it can cause damage to the house. Condensation runoff should be checked regularly, especially during the autumn. Clean if necessary. Pipe with heating cable for draining the condensation water trough is not included. To ensure this function the accessory KVR 10 should be used. The electrical installation and wiring must be carried out under the supervision of an authorised electrician. The condensation water (up to 50 litres/24 hrs) that collects in the trough should be routed away by a pipe to an appropriate drain, it is recommended that the shortest outdoor stretch possible is used. Use a water trap for installations where air circulation may occur in the condensation water pipe. The insulation must seal against the bottom of the condensation water trough. RECOMMENDED ALTERNATIVE FOR LEADING OFF CONDENSATION WATER If none of the recommended alternatives is used good lead off of condensation water must be assured. Stone caisson Frostfritt Frost proof depth If the house has a cellar the stone caisson must be positioned so that condensation water does not affect the house. Otherwise the stone caisson can be positioned directly under the heat pump. The outlet of the condensation water pipe must be at frost free depth. The section of the pipe that can be affected by frost must be heated by the heating cable to prevent freezing. Route the pipe downward from F2040. The outlet of the condensation water pipe must be at a depth that is frost free or alternatively indoors (with reservation for local ordinances and regulations). NIBE F2040 7

Drain indoors Water seal The condensation water is lead to an indoor drain (subject to local rules and regulations). Route the pipe downward from F2040. The condensation water pipe must have a water seal to prevent air circulation in the pipe. KVR 10 spliced as illustrated. Pipe routing inside house not included. Gutter drainage Water seal Frostfritt Frost proof depth djup The outlet of the condensation water pipe must be at frost free depth. Route the pipe downward from F2040. The condensation water pipe must have a water seal to prevent air circulation in the pipe. 8 NIBE F2040

Pipe installation GENERAL Pipe installation must be carried out in accordance with current norms and directives. F2040 can only operate up to a return temperature of about 55 C and an outgoing temperature of about 58 C from the heat pump. F2040 is not equipped with external shut off valves on the water side; these must be installed to facilitate any future servicing. The return temperature is limited by the return line sensor. Water volumes When docking with F2040 free flow in the climate system is recommended for correct heat transfer. This can be achieved by use of a bypass valve. If free flow cannot be ensured, it is recommended that a buffer tank (NIBE UKV) is installed. Following water volumes are recommended F2040 Minimum volume, climate system during heating/cooling Minimum volume, climate system during under floor cooling -6 20 l 50 l -8 50 l 80 l -12 80 l 100 l -16 150 l 150 l Charge pump The charge pump (not included in the product) is powered and controlled from the indoor module/control module. It has a built-in anti-freezing function and must therefore not be switched off when there is a risk of freezing. At temperatures below +2 C the charge pump runs periodically, to prevent the water from freezing in the charge circuit. The function also protects against excess temperatures in the charge circuit. PRESSURE DROP DIAGRAM Pressure drop Pressure (kpa) drop (kpa) 30 25 20 15 10 5 8,12 6,16 0 0,0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 Flow l/s PIPE COUPLING HEATING MEDIUM CIRCUIT The heat pump must be vented via the upper connection using the venting nipple on the enclosed flexible hose. Install the enclosed particle filter before the inlet, i.e. the lower connection on F2040. All outdoor pipes must be thermally insulated with at least 19 mm thick pipe insulation. Install shutoff and drain valves so that F2040 can be emptied in the event of prolonged power failures. The supplied flexible hoses act as vibration dampers. The flexible pipes are fitted so an elbow is created, thus acting as vibration damping. NIBE F2040 9

PIPE CONNECTIONS FLE HOSE CONNECTING ACCESSORIES Instructions for connecting accessories can be found in the installation instructions provided for the respective accessory. See page 23 for a list of possible extended functions. DATA Heat insulation DOCKING F2040 can be connected in several ways. The necessary safety equipment must be installed in accordance with current regulations for all docking options. See nibe.se/dockning for more detailed docking options. 10 NIBE F2040

Electrical connections The heat pump must not be connected without the permission of the electricity supplier and must be connected under the supervision of a qualified electrician. If a miniature circuit-breaker is used, this must have motor characteristic C (compressor operation). For MCB size, see Technical Specifications in the Installer Manual. F2040 does not include a circuit breaker on the incoming power supply. For this reason, the heat pump s supply cable must be connected to a circuit breaker with at least a 3 mm breaking gap. If the building is equipped with an RCD, the heat pump should be equipped with a separate one. The RCD should have a nominal tripping current of no more than 30 ma. Incoming supply must be 230 V 50Hz via electrical distribution units with fuses. If an insulation test is to be carried out in the building, disconnect the heat pump. Communication cable is inserted from the rear. Connect communication cable from terminal block to the indoor module. Electrical installation and any servicing must be carried out under the supervision of a qualified electrician. Disconnect the current with the circuit breaker before carrying out any servicing. Electrical installation and wiring must be carried out in accordance with the national stipulations in force. NIBE F2040 11

Maintenance When your heat pump is located outdoors some external maintenance is required. Insufficient maintenance can cause serious damage to F2040, which is not covered by the guarantee. Checking grilles and bottom panel Check that the inlet grille is not clogged by leaves, snow or anything else regularly throughout the year. You should be vigilant during windy conditions and/or in the event of snow as the grilles can become blocked. Also check that the drain holes in the bottom panel (three) are free from dirt and leaves. Regularly check that condensation is routed away correctly through the condensation pipe. Ask your installer for assistance if required. Cleaning the outer casing If necessary the outer casing can be cleaned using a damp cloth. Care must be exercised so that the heat pump is not scratched when cleaning. Avoid spraying water into the grilles or the sides so that water penetrates into F2040. Prevent F2040 coming into contact with alkaline cleaning agents. Prevent snow building up and covering the grille on F2040. Keep free of snow and/or ice. 12 NIBE F2040

Functions When connection to NIBE indoor module / control module (VVM / SMO) is ready, you can control your unit via the indoor module / control module. Control, general The indoor temperature depends on several different factors. Sunlight and heat emissions from people and household machines are normally sufficient to keep the house warm during the warmer parts of the year. When it gets colder outside, the climate system must be started. The colder it is outside, the warmer radiators and under floor heating system must be. Control of the heat production is performed based on the "floating condensing" principle, which means that the temperature level needed for heating at a specific outdoor temperature is produced based on collected values from the outdoor and supply temperature sensors. The room sensor can also be used to compensate the deviation in room temperature. Heat production The supply of heat to the house is regulated in accordance with the heating curve setting selected. After adjustment, the correct amount of heat for the current outdoor temperature is supplied. The supply temperature of the heat pump will oscillate around the theoretically required value. OWN CURVE F2040 has pre-programmed non-linear heating curves. It is also possible to create your own defined curve. This is an individual linear curve with a number of break points. You select break points and the associated temperatures. Hot water production Hot water charging starts when the temperature has fallen to the set start temperature. Hot water charging stops when the hot water temperature at the hot water sensor has been reached. For occasional higher hot water demand, there is a function called "temporary lux" that allows the temperature to be raised via one time increase or up to 12 hours (selected in the menu system). It is also possible to set F2040 in holiday mode, which means that the lowest possible temperature is achieved without the risk of freezing. Additional heat only ADDITIONAL HEAT ONLY The indoor module (VVM), which is connected to F2040, can be used with the additional heat alone (electric boiler) to produce heating and hot water, for example before the outdoor module is installed. Alarm indications The status lamp lights red in the event of an alarm and the display shows detailed information depending on the fault. An alarm log is created with each alarm containing a number of temperatures, times and operating status. NIBE F2040 13

The display The indoor module (VVM) / control module (SMO) is controlled using a clear and easy to use display. Instructions, settings and operational information are shown on the display. You can easily navigate between the different menus and options to set the comfort or obtain the information you require. The display unit is equipped with a USB socket that can be used to update the software and save logged information in F2040. Visit nibeuplink.com and click the "Software" tab to download the latest software for your installation. NIBE Uplink Using the Internet and NIBE Uplink, you can obtain a quick overview and the present status of the installation and the heating in your home. You can obtain a good overall view, allowing you to monitor and control the heating and hot water comfort effectively. If the system is affected by a malfunction, you receive an alert via e-mail that allows you to react quickly. NIBE Uplink also gives you the opportunity to control the comfort in your home easily, no matter where you are. NIBE SMART PRICE ADAPTION Smart Price Adaption is not available in all countries. Contact your NIBE dealer for more information. Smart Price Adaption adjusts the heat pump's consumption according to the time of day that electricity prices are lowest. This allows for savings, provided that the hourly rate subscription has been signed with the electricity supplier. The function is based on hourly rates for the coming day being downloaded via NIBE Uplink. To use the function, an Internet connection and account on NIBE Uplink are necessary. SMART HOME When you have a smart home system that can communicate with NIBE Uplink, you can control the installation via an app by activating the smart home function. By allowing connected units to communicate with NIBE Uplink, your heating system becomes a natural part of your homesmart home and gives you the opportunity to optimise the operation. Remember that the smart home function requires NIBE Uplink in order to work. RANGE OF SERVICES You have access to different levels of service via NIBE Uplink. A basic level that is free and a premium level where you can select different extended service functions for a fixed annual subscription fee (the subscription fee varies depending on the selected functions). NIBE Uplink also available as an app from App Store and Google Play. INSTALLATION AND ASSOCIATED EQUIPMENT REQUIREMENTS The following is required in order for NIBE Uplink to function with the installation: Network cable (straight, at least Cat 5E UTP). Internet connection. Web browser that supports JavaScript. For further presentation, visit nibeuplink.com. 14 NIBE F2040

F2040 IT'S IN OUR NATURE Technical data Dimensions and setting-out coordinates F2040-6 307 924 364 383 40-50 741 80 334 990 993 * Accessory KVR 10 is required. F2040-8 Ställbar 40-50 855 Adjustable 40-50 100 400 670 50 365 422 15 965 1035 225 95 90 Ø40* * Accessory KVR 10 is required. NIBE F2040 15

F2040-12 Ställbar 40-50 955 Adjustable 40-50 110 243 512 255 50 50 395 452 14 1075 1145 265 108 85 Ø40* * Accessory KVR 10 is required. F2040-16 Ställbar 40-50 1410 Adjustable 40-50 110 243 512 180 50 80 395 452 14 1075 1145 265 108 85 Ø40* * Accessory KVR 10 is required. 16 NIBE F2040

IT'S IN OUR NATURE Sound pressure levels F2040 is usually placed next to a house wall, which gives a directed sound distribution that should be considered. Accordingly, you should always attempt when positioning to choose the side that faces the least sound sensitive neighbouring area. The sound pressure levels are further affected by walls, bricks, differences in ground level, etc and should therefore only be seen as guide values. F2040 adjusts the fan speed depending on the ambient temperature and evaporation temperature. 2 m 6 m 10 m Air/water heat pump Sound power level* According to EN12102 at 7/45 (nominal) L W (A) F2040-6 50 F2040-8 54 F2040-12 57 F2040-16 61 Sound pressure level at 2 m free standing.* Sound pressure level at 6 m free standing.* Sound pressure level at 10 m free standing.* db(a) db(a) db(a) 36 26.5 22 40 30.5 26 43 33.5 29 47 37.5 33 * Free space. NIBE F2040 17

Technical data Air/water heat pump F2040-6 F2040-8 F2040-12 F2040-16 Output data Heating Outdoor temp./ Supply temp. Nominal Nominal Nominal Nominal Output data according to EN 14511 ΔT5K 7/35 C (floor) 2.67/0.5/5.32 3.86/0.83/4.65 5.21/1.09/4.78 7.03/1.45/4.85 Capacity / supplied capacity / COP (kw/kw/-) 2/35 C (floor) 7/45 C 2.32/0.55/4.2 2.28/0.63/3.62 5.11/1.36/3.76 3.70/1.00/3.70 6.91/1.79/3.86 5.00/1.31/3.82 9.33/2.38/3.92 6.75/1.74/3.88 2/45 C 1.93/0.67/2.88 5.03/1.70/2.96 6.80/2.24/3.04 9.18/2.98/3.08 Cooling Outd. temp: / Supply temp. Max Output data according to EN 14511 ΔT5K 27/7 C 5.87/1.65/3.56 7.52/2.37/3.17 9.87/3.16/3.13 13.30/3.99/3.33 Capacity / supplied capacity / EER 27/18 C 35/7 C 7.98/1.77/4.52 4.86/1.86/2.61 11.20/3.20/3.50 7.10/2.65/2.68 11.70/3.32/3.52 9.45/3.41/2.77 17.70/4.52/3.91 13.04/4.53/2.88 35/18 C 7.03/2.03/3.45 9.19/2.98/3.08 11.20/3.58/3.12 15.70/5.04/3.12 Electrical data Rated voltage 230V ~ 50Hz, 230V 2 ~ 50Hz Max operating current, heat pump A rms 15 16 23 Max operating current, compressor A rms 14 15 22 Starting current A rms 5 Nominal output, fan W 50 86 86 Fuse 1) A rms 16 16 25 Enclosure class IP 24 25 24 2 x 86 25 Refrigerant circuit Type of refrigerant R410A GWP refrigerant 2,088 Type of compressor Twin Rotary Compressor oil M-MA68 Volume kg 1.5 2.55 2.9 4.0 CO 2 equivalent t 3.13 5.32 6.06 8.35 Cut-out value pressostat HP MPa - 4.15 (41.5 bar) Cut-out value HP 4.15 (41.5 bar) - Cut-out value pressostat LP MPa - 0.079 (0.79 bar) Brine Airflow m 3 /h 2,530 3,000 4,380 6,000 Min. / Max. air temp. C -20 / 43 Defrosting system Reverse cycle Heating medium Min/Max system pressure heating medium MPa 0.05/0.25 (0.5/4.5bar) Min volume, climate system, heating/cooling l 20 50 80 150 Min volume, climate system, under floor cooling l 50 80 100 150 Max flow, climate system l/s 0.29 0.38 0.57 0.79 Min flow, climate system, at 100% circulation pump speed (defrosting flow) l/s 0.19 0.19 0.29 0.39 Min flow, heating l/s 0.09 0.12 0.15 0.25 Min flow, cooling l/s 0.11 0.15 0.20 0.32 Min. / Max. HM temp continuous operation C 25 / 58 Connection heating medium ext thread G1" Miscellaneous Weight (excl. packaging) kg 66 90 105 135 Part No. 064 206 064 109 064 092 064 108 1)Specified output is limited with lower fusing. 18 NIBE F2040

SCOP & PDESIGNH SCOP & P designh F2040 according to EN 14825 F2040 6 8 12 16 P designh SCOP P designh SCOP P designh SCOP P designh SCOP SCOP 35 Average climate 4.8 4.8 8.2 4.38 11.5 4.43 14,5 4.48 SCOP 55 Average climate 5,3 3.46 7.0 3.25 10 3,38 14 3.43 SCOP 35 Cold climate 4,0 3,65 9 3.55 11.5 3.63 15 3.68 SCOP 55 Cold climate 5,6 2.97 10 2.78 13 2.85 16 2,9 SCOP 35 Warm climate 4,2 6.45 8 5,7 12 5.8 15 5.95 SCOP 55 Warm climate 4.76 4.58 8 4.58 12 4.7 15 4.8 ENERGY RATING, AVERAGE CLIMATE Model Control module model Temperature application The product s room heating efficiency class 1) Space heating efficiency class of the system 2) C F2040-6 SMO 35 / 55 A++ / A++ A+++ / A++ F2040-8 SMO 35 / 55 A++ / A++ A+++ / A++ F2040-12 SMO 35 / 55 A++ / A++ A+++ / A++ F2040-16 SMO 35 / 55 A++ / A++ A+++ / A++ 1Scale for the product s room heating efficiency class A++ to G. 2Scale for the system s room heating efficiency class A+++ to G. The reported efficiency of the package also takes the controller into account. If an external supplementary boiler or solar heating is added to the package, the overall efficiency of the package should be recalculated. NIBE F2040 19

Working area Compressor operation heating Water temperature 65 60 55 50 45 40 35 30 25 20 15-30 -20-10 0 10 20 30 40 50 Framledning Flow pipe Returledning Return pipe Outdoor Utomhustemperatur temperature During shorter time it is allowed to have lower working temperatures on the water side, e.g. during start up. Compressor operation cooling Water temperature 35 30 25 20 15 10 5 0 10 15 20 25 30 35 40 45 Flow Framledning pipe Return Returledning pipe Outdoor Utomhustemperatur temperature Capacity and COP Capacity and COP at different supply temperatures. Maximum capacity including defrosting. Max. capacity F2040-6 Heating output (kw) 9,00 8,00 7,00 6,00 4,00 3,00 1,00 35 55 0,00-25 -20-15 -10-5 0 5 10 35 C Outdoor Utomhustemperatur temperature 45 C 55 C COP F2040-6 COP 4,00 3,50 3,00 2,50 2,00 1,50 1,00 0,50 0,00-25 -20-15 -10-5 0 5 10 35 C Utomhustemperatur Outdoor temperature 45 C 55 C 45 35 45 55 20 NIBE F2040

Max specified output F2040-8 Max specified output F2040-12 Heating output (kw) Heating output (kw) 12,00 10,00 8,00 35 45 55 16,00 14,00 12,00 10,00 35 45 55 6,00 8,00 4,00 2,00 6,00 4,00 2,00 0,00-25 -20-15 -10-5 0 5 10 15 35 C Utomhustemperatur Outdoor temperature 45 C 55 C COP F2040-8 COP 0,00-25 -20-15 -10-5 0 5 10 15 35 C Utomhustemperatur Outdoor temperature 45 C 55 C COP F2040-12 COP 5,00 4,00 3,00 2,00 35 45 55 6,00 5,00 4,00 3,00 2,00 35 45 55 1,00 1,00 0,00-25 -20-15 -10-5 0 5 10 15 35 C Utomhustemperatur Outdoor temperature 45 C 55 C 0,00-25 -20-15 -10-5 0 5 10 15 35 C Outdoor Utomhustemperatur temperature 45 C 55 C NIBE F2040 21

Max specified output F2040-16 Heating output (kw) (kw) 25,00 20,00 35 45 55 15,00 10,00 5,00 0,00-25 -20-15 -10-5 0 5 10 15 35 C Utomhustemperatur Outdoor temperature 45 C 55 C COP F2040-16 COP 6,00 5,00 4,00 35 45 3,00 55 2,00 1,00 0,00-25 -20-15 -10-5 0 5 10 15 35 C Outdoor Utomhustemperatur temperature 45 C 55 C Output with lower fuse rating than recommended Supplied power F2040-12, fuse rating 16A Heating Uppvärmningskapacitet output vid 16A avsäkring (kw) 16,00 14,00 12,00 10,00 8,00 6,00 4,00 2,00 0,00-25 -20-15 -10-5 0 5 10 15 35 C Utomhustemperatur Outdoor temperature 45 C 55 C Supplied power F2040-12, fuse rating 20A Uppvärmningskapacitet Heating output vid 20A avsäkring (kw) 16,00 14,00 12,00 10,00 8,00 6,00 4,00 2,00 35 45 55 35 45 55 0,00-25 -20-15 -10-5 0 5 10 15 35 C Utomhustemperatur Outdoor temperature 45 C 55 C Supplied power F2040-16, fuse rating 20A Heating Uppvärmningskapacitet output vid 20A avsäkring (kw) 25,00 20,00 15,00 35 45 55 10,00 5,00 0,00-25 -20-15 -10-5 0 5 10 15 35 C Outdoor Utomhustemperatur temperature 45 C 55 C 22 NIBE F2040

Accessories Detailed information about the accessories and complete accessories list available at nibe.eu. Not all accessories are available on all markets. Condensation water pipe Condensation water pipe, different lengths. Earth circuit breaker 1-phase. KVR 10-10 F2040 / HBS05 1 metres Part no. 067 614 KVR 10-30 F2040 / HBS05 3 metres Part no. 067 616 KVR 10-60 F2040 / HBS05 6 metres Part no. 067 618 Stand and brackets Ground stand F2040-6, -8, -12, -16 Part no. 067 599 Wall bracket F2040-6, -8, -12 Part no. 067 598 NIBE F2040 23

NIBE Energy Systems Box 14, SE-285 21 Markaryd nibe.eu PBD EN 1812-2 M12015 WS name: -Gemensamt WS version: a493 (working edition) Publish date: 2018-03-14 09:10 This product sheet is a publication from NIBE Energy Systems. All product illustrations, facts and data are based on current information at the time of the publication s approval. NIBE Energy Systems makes reservations for any factual or printing errors in this product sheet. 2017 NIBE ENERGY SYSTEMS