HIGH OUTPUT. Skin design RANGE

Similar documents
C1210ES Tankless Water Heater

C1050ES Tankless Water Heater

940ES Tankless Water Heater

940ES Tankless Water Heater

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

C1210ESC Tankless Water Heater

1 VICTRIX ZEUS Superior kw I features

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

Seradens Super Seradens Super Plus

wall-mounted boilers, water heaters and pool heaters floor standing boilers, water heaters and pool heaters

DOMESTIC HOT WATER Follow operational sequence

The WCGH High Efficiency Commercial Water Heater with Storage Tank

Residential Gas Condensing Boiler Greenstar combi 100 p / 151 p ZWB28-3A... ZWB42-3A...

Bosch Greentherm T9800 SE 199 Gas Tankless Water Heater

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND

96.2% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS CON X US REMOTE CONNECT. MODBUS AND BACnet MSTP PROTOCOL

NIKE Star 24 3 E. Instantaneous wall-hung with open chamber boilers. NIKE Star 24 3 E

TANKLESS WATER HEATER HEATING SOLUTIONS

wall-mounted boilers, water heaters and pool heaters from 15 kw to 140 kw

Up to 94.6% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL CONDENSING BOILERS OPERATING CONTROL FEATURING A BUILT-IN CASCADING SEQUENCER

AGUAdens TM 100% residential condensing D.H.W. wall-mounted water heaters ( litres) AISI 316 D.H.W. WORKING PRESSURE TITANIUM CONDENSING

USERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book

GB24 & GB30. User Manual

24-28 kw Conventional Combi Gas Boiler. Lawa / LawaPlus

VICTRIX 50 1 SPECIFICATIONS. Wall mounted condensing boilers

Gas-Fired Condensing Boilers A Green Start to Space & Water Heating

HIGH EFFICIENCY COMMERCIAL BOILERS

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions.

940ESO Tankless Water Heater

BG2000S PRE-MIX GAS BURNER

i 24, i 30, i 35 combination boilers USER GUIDE For Installation Guide see reverse of book UIN A05 October 2017

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

BOSCH CONDENS 5000W ZSB18-2A

The mechatronics of EVE 05

ProCon Boiler Controller Commissioning Quick Reference Guide

The iqe Boiler Range. Combination and System T Boilers.

Commercial Tankless Rack System

MAIOR EOLO 4 E. Instantaneous wall-hung boilers, sealed-room with "Aqua Celeris" system MAIOR EOLO 4 E

Gas-Fired Condensing Boilers A Green Start To Space & Water Heating

Get The Edge Over The Competition with The Summit

Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE WARRANTY

Figure 10 or Figure 6

Mikrofill Ethos Condensing combination boiler

Quinta Pro Range. The New Remeha. Condensing Boilers REMEHA QUINTA PRO RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission

Commercial Tankless Rack System

TWINTEMP JR. HYDRONIC SYSTEM 2/2013

SPECIFICATIONS - NIKE

COMMERCIAL-GRADE RESIDENTIAL GAS WATER HEATERS

COMBI BOILERS ECOCONDENS SILVER PLUS -20 ECOCONDENS SILVER PLUS -25 ECOCONDENS SILVER PLUS -35

AVIO kw Export 1 FEATURES. Wall-mounted with storage tank

Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse

Tankless Condensing High Efficiency Water Heaters

High quality... SEALED PRE-MIXED MODULATING FAN SPECIAL METAL FIBRE BURNER FLAME DETECTION ELECTRODE IGNITION ELECTRODE FLUE OUTLET

Residential Gas Tankless Water Heater

WOLF GAS CONDENSING BOILERS COMFORTLINE

Tankless Condensing High Efficiency Water Heaters with Built-In Pump

Technology marries design. The boiler finally becomes a piece of design, emerging as a protagonist in a new domestic environment.

SAFETY FEATURES: Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse

Service booklet for the Engineer for Gas Condensing Boilers

WALL-HUNG HIGH EFFICIENCY GAS BOILERS. Elegant, efficient and intelligent

SOLID. STATE. Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE

Commercial Tankless Rack System

Crossover. Hybrid Water Heater HIGH EFFICIENCY. Advanced Heating & Hot Water Systems. w w w.htproducts.com

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

ENERGY TOP. Condensing boiler solutions

SENSEI Series Features

Technology marries design. The boiler finally becomes a piece of design, emerging as a protagonist in a new domestic environment.

HCLEARFIRE. High-efficiency, modular steam boiler HP

Commercial Tankless Rack System

MULTI-LINK UP TO 20 UNITS COMMON VENT UP TO 8 UNITS COMPLIES WITH LEAD FREE STANDARDS SAFETY FEATURES:

The Ideal Logic. Combination, Heat Only and System Boilers. Heating Solutions.

Ciao Green Condensing Wall-Hung Boilers

Mynute Green k. Condensing Wall-Hung Boilers. Residential Heating

GREENSPRING CWi47 INSTALLATION AND OPERATING INSTRUCTIONS WALL HUNG RSF GAS CONDENSING INSTANTANEOUS WATER HEATER FOR MAINS FED DOMESTIC HOT WATER

Trinity Tft High Efficiency Gas Condensing Boiler & Water Heater

CONTENTS PRODUCT GAS TYPE CONVERSION ADJUSTMENTS FAULT & FAILURE. Product Notation Safety Systems Technical Data Main Components Operating Functions

ALKON 90 ALKON 90 MODEL 24,0 93,6 21,1 87, nominal heat output. conventional. max/min heat input. efficiency class (Directive 92/42)

Wood gasification process...3. Wood as a fuel...3. Boiler construction - its elements...4

The NEW Greenstar i. intuitive. innovative. improved performance. installation ease

white blue cobalt bordeaux light oak (rovere)

CAUTION. Installation Manual

24/31-28/35-32/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus

Utica Boilers MAC Submittal

CITY OPEN - CITY BOX from 25 to 35 kw

Q - Series Boiler. Troubleshooting Manual

VICTRIX Superior kw Export VICTRIX Superior kw X Export

VCLEARFIRE. High-Efficiency, Commercial Steam Boiler Horsepower

/2010 US/CA

10 : 1 Turndown Ratio

Great Britain en. Installation, user and service manual. Control panel HMI Gas 310/610 ECO PRO

Read installation manual prior to installation of this unit! Read user manual before putting this unit in operation!

Servicing manual. Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C /2002 GB(EN) For trade use

Crossover. Hybrid Water Heater. High Efficiency. Advanced Heating & Hot Water Systems.

4FLOOR-STANDING GAS CONDENSING BOILERS

Logic+ Combi

Servicing manual. 600 Series - 11S / 19S / 24S / 24C. Wall-mounted condensing gas boiler. For trade use

96% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR

24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus.

USER'S INFORMATION MANUAL

Transcription:

Light drop design HIGH OUTPUT Skin design RANGE Trim design 1

Product Introduction Product Presence Worlwide 2

Product Presentation Bosch Model Commercial Name: GWHC 27 3

Product Presentation Product Design 4

Product Presentation System Diagram Comparison

Product Presentation System Diagram Condensing model 1 Exhaust temperature sensor 2 Flue gas collector 3 Heat exchanger 4 Ionization sensor 5 Primary fan 6 Hot water temperature sensor 7 LCD display 8 On/off button 9 Reset button 10 Program key 11 Flue gas limiter 12 Heat exchanger overheat sensor (ECO) 13 Ignition electrodes 14 Observation window 15 Backflow temperature sensor 16 Secondary air fan 17 Gas valve 18 Condensate trap 19 Water valve with flow sensor and cold water temperature sensor 20 Control unit 21 Up button 22 Down button 23 LED 6

Product Presentation System Diagram Non-Condensing model 1 Flue gas collector 2 Heat exchanger 3 Ionization sensor 4 Primary fan 5 Hot water temperature sensor 6 LCD display 7 On/off button 8 Reset button 9 Program key 10 Flue gas limiter 11 Heat exchanger overheat sensor (ECO) 12 Ignition electrodes 13 Observation window 14 Backflow temperature sensor 15 Secondary air fan 16 Gas valve 17 Water valve with flow sensor and cold water temperature sensor 18 Control unit 19 Up button 20 Down button 21 LED 7

Range & Characteristics Optional Accessories Intelligent Cascading Up to 12 units 1.9 to 324l/min Master rotation after 100h of operation Failure redundant High Set Temperature Default range from 38ºC to 38ºC 60ºC 60ºC Unlock up to 84ºC for higher and special 84ºC demanding applications Remote Control Temperature control and functional status Up to 6 remotes on the same unit 30m distance working range Outdoor & Anti Freeze Outdoor kit with IPX5D protection level Anti freeze protection effective down to -15ºC 13

Range & Characteristics Optional Accessories Intelligent cascading Max 12 units 0 hours Master Slave 01 Slave 02 Slave 03 ---- ---- Slave 11 100 hours Slave 11 200 hours Slave 10 Master Slave 11 Slave 01 Master Slave 02 Slave 01 ---- ---- ---- ---- Slave 10 Slave 09 300 hours Slave 09 Slave 10 Slave11 Master ---- ---- Slave 08 Intelligent cascading software The software has the ability of automatically rotating the Master unit at each 100 hours of functioning Advantages Redistribution of the work load of the installation equally trough all units installed Extension of the maximum number of appliances installed in the cascade from 4 to 12 Requirements and limitations Require a cascade kit, with the TTNr: 7 736 500 272; the kit is composed by two connecting cables to close the loop between the first and the last unit installed The factory supply is set for Intelligent Cascade Mode. Compatibility with the previous software, requires the setting on the PCB to be changed for Simple Cascade Mode 14

Range & Characteristics Optional Accessories Higher set point With a optional kit, it will be possible to reach higher set temperatures up to 84ºC Advantages Change is effective on both condensing and non condensing units Units become suitable for high temperature demanding applications Requirements and limitations Requires a optional kit, with the TTNr: 7 736 500 605 The kit is composed by two jumpers, to be placed on JP7 and JP8 15

Benefits 16

Benefits and USPs for End Customers High volumes of hot water to serve unique commercial applications Up to 27L / minute at a 25ºC rise Energy savings to reduce utility costs Condensing technology Space savings compared to large storage tanks common to commercial applications Cost savings due to ability to use plastic venting (condensing model only) 17

Range & Characteristics Case Studies Canteen Consumption of 2.000L at 40ºC Peaks of 50l/min during 20 minutes No central heating Bosch Solution Trad. Solution Bosch Solution Traditional Solution Installation space 1.5 m 2 3.0 m 2 Total energy consumption 1.060 MJ 1.285 MJ Equipment costs 70 100 15 room hotel Consumption of 5.000L at 40ºC Peaks of 80l/min during 45 minutes Central heating required Savings -50.0 % -17.5% -30% 2 x 27L condensing W2 s 1 x 24kW boiler 1 x 400L storage tank Bosch Solution Trad. Solution Bosch Traditional Solution Solution Savings Installation space 3.2 m2 5.2 m2-38.5 % Total energy consumption 4.456 MJ 4.517 ML -1.4% Equipment costs 88 100-12% 4 x 27L condensing W2 s 1 x 65kW condensing boiler 1 x 100kW cond. boiler 1 x 1.000L storage tank 20

Product Description 21

Characteristics Appliance designed for multiple and simultaneous points of use 22

Range & Characteristics Capacity 27 litres, condensing 24 litres, non-condensing Room sealed platform Standard 80/80 and 80/125 TT flue accessories Low NOx emissions burner Fault diagnose and service mode Thermostatic with priority to set temperature Capacity grows proportionally when in cascade

Control Panel On/Off button Error / Reset button Program button Increase button Decrease button 24

Digital Display Flame indicator Power bar indicator Solar application Lock symbol Temperature indicator Error symbol Remote Control 25

Digital Display Temperature indicator: ºC or F Possible selection 26

Digital Display Power bar indicator: Indication of the current operation power 27

Digital Display Flame indication: Lights when the burner is on 28

Digital Display Warning symbol: Indication that an error has occurred or, that during normal working, something is out of the safety range 29

Digital Display Solar application: Indication that the automatic solar function is activated and, as the appliance is receiving pre-heated hot water, the burner will not start 30

Digital Display Lock symbol: Indication of locked control, as another user got the remote control priority it 31

Digital Display Radio Frequency signal: Indication that remote control signal is activated. In case of cascading applications indicates the appliance currently as master 32

Product Features Remote Control A wireless remote control allows the end user to adjust the temperature or see error codes from up to 30m away. A total of 6 remotes can be used with any single appliance. 33 Termotecnologia

Characteristics Recirculation through the heater is possible and a good solution, in case of an installation with very long pipes to the consumption points of use, allowing water savings 34

Characteristics The end user can have immediately hot water on the tap. Important: In order to get an optimal efficiency of the system, the pump shall be controlled by a timer and a thermostat. 35

Characteristics Solar Application The water heater allow the use of pre-heated water and suitable as backup and compatible with solar applications with both thermo siphon and / or forced systems 36

Characteristics Solar Application Functionality: T set :45ºC T in = T set - 5ºC (burner stop) In case the inlet water temperature is within a range of ± 5ºC of the set point temperature, the appliance will not turn on and the solar symbol appears on the LCD. The maximum inlet temperature to the water heater is 60ºC. 37

Characteristics A. F. l A. F. l / m / m 86.12 Max ;2. T 5 set 5 T º C in º C 86.12 Max ;1. 9 Tset 5 º C Tin º C Decrease activation flow Activation flow was reduced from 2.5 l/min to 1.9 l/min, respecting the activation conditions of the solar mode Tout [ºC] [Tin=10ºC] 60.00 55.3 44.4 38.0 1.9 2.5 3.1 Flow [l/min] Advantages Wider response flow range of the unit Limitations Increase of the minimum outlet temperature for minimum water flow 38

Components overview Non Condensing appliance Inlet air Combustion gases exhaust Flue gas collector Heat Exchanger Primary Fan (Mixer) Secondary Air Fan 39

Components overview Non Condensing appliance Wall fixation Structure Control Panel Gas Valve LCD Digital Display 40

Components overview Condensing appliance Condensing heat exchanger Drain pipe Inlet air/mixer pipe 41

Components Characteristics Separate chambers Outer case Combustion chamber cover

Components Characteristics Heat Exchanger Fins soldering Turbulators

Components Characteristics Heat Exchanger Increased number of fins and fixed fixation of electrodes Ionization Electrode Spark plug Electrodes kept in position when dismounting HE 44

Components Characteristics Condensing Heat Exchanger Easy connections clips and plug in & out cables SERVICE FRIENDLY NTC sensor Drain Pipe 45

Components Characteristics Condensing Heat Exchanger Condensing The use of a condensing appliance contributes to achieve higher efficiency by incorporating a secondary (cast aluminum) heat exchanger. Functionality: The heat in the exhaust gases is used to preheat the inlet water, and uses the energy that would, otherwise, be lost. The water vapor produced by the consumption of gas condenses back into liquid water, which needs to be safely drained due to its impurity. 46

Components Characteristics Condensing Heat Exchanger 47

Components Characteristics Burner and Fans Low NOx Pre-mix Burner This gas water heater has Class 4 NOx emissions (less than 100mg/kWh) Functionality: The pre-mixed burner technology combines the air and gas into the optimal ratio before entering the burner, ensuring a clean and efficient combustion. 48

Components Characteristics Burner and Fans Pre-mix burner Secondary air area Primary fan: air and gas mixture Secondary fan: air injection 49

Components Characteristics Burner and Fans Flame without secondary air (concentrated heat points) Flame with secondary air - homogeneous temperature distribution through the fins. 50