SD2. Differential Controller. Operating and Installation Instructions F2 72.3

Similar documents
Lago SD3. Differential Controller with Speed Control. Operating and Installation Instructions

Safety. DANGER Indicates potentially fatal situations. WARNING Indicates possible danger to life and limb.

1 DOCUMENT REVISION CONTROL ELEMENTS... 9

Installation and operating instructions. Temperature difference controller 6 inputs, 3 outputs, integrated data logger for SD card

Installation and Operating Manual. Merlin 5064 V3. System Manager

V. DIFFERENTIAL THERMOSTAT

GMA 301. Operation Manual. Worldwide Supplier of Safety Solutions. Part Number

E V1. System Manager Installation Manual

ST 53.1 User s manual

Operating instruction. Remote control station WCM-FS /

SCHMIDT LED Measured Value Display MD Instructions for Use

ST Wiring diagram. Product description. Four-stage controller. Order number

Heating controller Lago

ProCon Boiler Controller Commissioning Quick Reference Guide

Installation and Operating Manual

BWAC Steuerung. Kochendwasser- Energiesparreinigung. Art.-Nr Version 1.0

Boiler controller S-Tronic Plus

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER. Version DC19

Boiler controller Lambdatronic S 3200

1 DOCUMENT REVISION SOFTWARE VERSION BASIC DESCRIPTION BASIC OVERVIEW OF HYDRAULIC DIAGRAMS HYDRAULIC DIAGRAMS...

G2484. Installation. - Control panel (in the panel front, on the inner wall, or on a DIN rail)

HEATING REGULATOR EPC11 End user manual.

RVL472. Heating Controller. Building Technologies HVAC Products. Series C. including d.h.w. heating

G a

Heating and D.h.w. Controller RVL482 Basic Documentation

RVA /109. Heating Circuit ZONE Controller. Instructions for the INSTALLER

Solar Controller SUNGO SL

E System Manager Operating instructions

VIESMANN. Installation instructions. Mixer extension kit. for contractors. Mixer extension kit. For one heating circuit with mixer

District heating controller for two heating circuits and d.h.w. according to Siemens specifications:

03.03.mmm REV.2 09/01

REA22 Room Temperature Controller

USER MANUAL. OPTIMA 312 ES960C circuit board

Electronic Pellet Burner Controller NPBC-V3-1

Monitoring Devices 11/1

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

M116 / M450 USER AND MAINTENANCE MANUAL FOR MODULATING-CONTROL BOILER WITH GAS BURNER EQUIPPED FOR NATURAL GAS. Type : B23 ATLANTIC 2000

Operation Manual of Solar controller SR1568 for split solar system

R. Boiler Energy Management System FW 200. Operating Instructions for the User (2010/05)

INSTRUCTION MANUAL REMOTE CONTROL DEVICE EASYREMOTE

RE-PR3-E-27 3-Phase Panel Mount 27kW

Boiler controller SPS 4000

GMA4100-DP. Control Panel. Operation Manual. Worldwide Supplier of Gas Detection Solutions

Connections, displays and operating elements C D E G H. Installing the control unit

ProCon 16, 31, 47, 75, 77 & HT. RVA 46. Zone Controller Commissioning Data.

VIESMANN. Installation instructions. Extension EA1. Safety instructions. for contractors. Part no

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63

EN Z Subject to change due to technical improvements! Operating instructions

Operating instructions

ProCon 16, 31, 47 & 75. RVA 63 Boiler and Circuit Controller Commissioning Data.

Edited by Foxit PDF Editor Copyright (c) by Foxit Software Comp. Programmable digital room thermostat. NEW software! Operating Instructions

Automation System TROVIS 5400 Boiler Controller TROVIS 5474

Dryer Controller M720

Electronic Pellet Burner Controller NPBC-V3M

RVP360 and RVP361 Heating controllers for 2 heating circuits and d.h.w. Basic Documentation

Installation and Service Instructions SM1 SOLAR CONTROL MODULE IMPORTANT. Read and save these instructions for future reference.

Mounting and Operating Instructions EB 5610 EN. TROVIS 5600 Automation System TROVIS 5610 Heating and District Heating Controller

GeyserWise MAX. Instruction manual. All in one hot water management

Installation and Operating Manual. Merlin IO 5064 V4 with BM-T. System Manager

GEYSERWISE INSTRUCTION MANUAL

TECHNICAL MANUAL BIOTEC 25 AND BIOTEC 40

02/11/2015

HYDRONIC L-II Troubleshooting and Repair Instructions

RVL481. Heating Controller. including d.h.w. heating

Heating Controller SDC. District Heating Controller DHC 43 OPERATING INSTRUCTIONS

RVP340 Heating controller for 1 heating circuit RVP350 and RVP351 Heating controllers for 1 heating circuit and d.h.w. Basic Documentation

Semi flush-mount room thermostats

TECH. Declaration of conformity no 23/2007

RVL47. Heating Controller. Installations Instructions. Installation

Installation and servicing instructions

GH10PA USER MANUAL. Program version 01 MANUAL FOR CONTROLLER FOR CONTROLLING CENTRAL HEATING BOILERS FIRED WITH PELLETS AND OATS

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

(Except 12-24VDC) Control output 12-24VDC. Power consumption Max. 8W Max. 4VA Max. 8W Max. 4VA Max. 8W Max. 4VA

Declaration of Conformity No. 27/2008

Operating instructions

A WORLD OF COMFORT. The troubleshooting and repair instructions are only valid. Heaters for petrol B 5 S 12 V

Engineers manual. Under counter machines

APC BC300 Series 40kW 208/450/480V User Guide

User Manual. Dryer Controller M720

Weekly thermostat for boilers Galan - regulator for management of heating elements and circuit SolarSentinel-DBTW Users guide.

MODEL: 47LPQ. Digital Panel Meters 47 Series. [3] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points

Solar regulator DIEMASOL C. Installation and Service Manual. User Guide G

RVL471 Heating and Domestic Hot Water Controller Basic Documentation

Datasheet PDCSY-MW-MD. Technical Overview. Features. Product warranty and total quality commitment. Heat Meter Integrator

Operating Manual RCM420

DTC 100/2 TDG. User s manual Installation and maintenance instructions

ST710-KHJV.03. Wiring diagram. Product description. Temperature controller. Order number

DEIF A/S. Technical Manual. Type EC-2 Engine Control Unit D. Technical Manual

Operating Instructions

ecomax 200 W Boiler regulator FOR SOLID FUEL BOILERS WITH A FAN OPERATION AND MAINTENANCE MANUAL ISSUE:

Content. Ⅰ General information 1. Ⅱ Product description 2. Ⅲ System description 3. Ⅳ Fault message 9. Packing list 9

Climapro 2. User manual. wireless room thermostat without receiver. To be left with the user.

DPC-1 Programmable digital thermostat with communication Versión 2.0. Technical Information. Ref: N

Control box FSTronic DES-FS

FLAME AMPLIFIER MODULE 3001

1 measurement signal input 4-20 ma for connection to an external gas sensor 5 freely programmable alarm switching points per measuring point

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

Operating instructions

User Manual 120/240/300 Outdoor Motion Detector

Transcription:

SD2 Differential Controller Operating and Installation Instructions F2 72.3 i Please follow the safety information and read these Instructions carefully before putting the system into operation.

Safety information General information General information Safety information Power connection regulations Please note the connection conditions specified by your local electrical power supply utility and the VDE regulations. Your heating control system may be installed and serviced only by appropriately authorized specialists. E If the system is not installed properly, there is a risk of fatal or severe personal injury. Warranty conditions If the system is not installed, commissioned, serviced and repaired professionally, this will render the manufacturer's warranty null and void. Important text passages! Important information is highlighted with an exclamation mark. E This attention symbol indicates dangerous situations. Installation Information on installation of the system is provided in Part 2 of this manual together with a connection diagram. Description Declaration of conformity This device corresponds to the requirements of the relevant guidelines and standards, if the corresponding regulations and the manufacturer's instructions are complied with. Function This controller enables the regulation of various types of system: 1) Solar regulation 2) Solid fuel boiler regulation 3) Solid fuel boiler regulation with solar integration 4) Solar regulation with two collectors 5) Solar regulation with two storage tanks 6) Solar regulation with reheating function 7) Solar regulation with tank for heating the boiler return flow The device is simple to operate and easy to control due to the direct temperature display in the first operating level. 2

The device is simple to operate and easy to control due to the direct temperature display in the first operating level. General information Description General information 2 Safety information 2 Power connection regulations 2 Warranty conditions 2 Important text passages 2 Installation 2 Description 2 Declaration of conformity 2 Function 2 Operation 4 Explanation of the operating elements 4 In display level (normal mode) 4 In operating level (setting parameters) 4 Program switch settings 4 Display (normal mode) 5 Starting up 6 Basic setting of the controller 6 Time / Weekday 6 Explanatory information 7 Modify set values 7 Set values protected by code no. (from No. 20) 7 Set values list 8 Explanation of the set values / functions 10 User set values 10 Resetting the production indicators 10 Pump kick function (temperature test function) 10 Reheating function 11 Fitter set values 11 Switching thresholds / Hystereses 12 Special functions 13 Hot water short time heating function 15 Pump kick function (temperature test function) 15 Production estimate / Volume flow counter 15 Other functions 17 Pump blocking protection 17 Stop pumps (temperature control) 17 For the fitter 18 Electrical connection 18 System 1 19 System 2 20 System 3 21 System 4 22 System 5 System 6 23 24 System 7 26 Sensors 27 Technical data 28 Error 28 3

Explanation of the operating elements Operation Operation Explanation of the operating elements In display level (normal mode) Ä OFF/ON/MANUAL switch (i / F / B) prog Access the operating level by pressing the Plus and Minus keys simultaneously. (Automatic reset after 2 min. without operation). In operating level (setting parameters) Ä Programming key (selection or input) Plus key (next value or increase value) Program switch settings i OFF: The pumps are not activated. F ON: Normal operation; regulation according to settings. B MANUAL: All pumps operate (all relays closed). The function is reset to Automatic mode F after 30 min. F2 72.3 i Minus key (previous value or decrease value) prog Press the Plus and Minus keys simultaneously to return to the display level. 4

Operation Explanation of the operating elements Display (normal mode) When in Normal mode, select the display required with the rotary knob at the front: A Designation of temperature displayed F - - Time F1 System 1,3,4,5,6,7: Temperature of collector System 2: Temperature of solid fuel boiler 2 F2 System 1+5+6: Return flow sensor of collector System 3: Temperature of solid fuel boiler System 4: Temperature of second collector System 7: Temperature of return flow collector F3 F4 C1 C2 System 1,2,3,4,6,7: Storage heater at top System 5: Temperature of storage heater 2 Temperature of storage heater 1 at bottom Day's production in kw Total production in kw. From 10 MW, display in MW (=> Arrow appears on " x1000") B C D E F Display the selected temperature / or time Weekday 1=Monday - 7=Sunday; here Saturday Pump operation indicator (Arrow = Pump ON) a = Pump A1 is ON (see connection diagram) b = Pump A2 is ON (see connection diagram) Operation indicator i = OFF, F = ON, (h = Hand => Pumps ON max. duration = 30 min.) When the total solar production in display C2 exceeds 10 MW, the three arrows appear above the text: " x1000". i E A B C D 6 F2 72.3 F 5

Basic setting of the controller Basic setting of the controller Starting up Starting up Starting up After the device has been properly installed, switch on the power supply: The software number for your device appears briefly in the display. Finally, the standard display indicators appear. The controller is now in operation and uses standard values. To define the correct display, the time and weekday can now be entered.! It is still necessary to enter the number of the system installed [P22] (refer to 'Modify set values'). Time / Weekday Ä 6 prog Press the Plus + Minus keys simultaneously => Operating level with set value display "01" [left] Press the Prog key => LED beside Prog lights up / Set the time with the Plus/Minus keys! Setting mode can be ended at any time by pressing the Plus + Minus keys simultaneously. Changes which have been entered but not stored by pressing the Prog key have no effect. Ä Ä Ä Press the Prog key => Save the new time Press the Plus key => Set value display "02" [left] Press the Prog key => LED beside Prog lights up / Set the weekday (1-7) with the Plus/Minus keys Press the Prog key => Save the weekday prog Press the Plus + Minus keys simultaneously => Normal mode with standard display.! The standard display can be selected/changed using the rotary knob.

Explanatory information Modify set values Explanatory information Modify set values prog Access the operating level by pressing the Plus and Minus keys simultaneously. Display: Left no. of the set value, Right set value Use the Plus/Minus keys to select the number of the set value required [Display: left].! A list of all the set values is provided on the following pages. Ä Ä Press the Prog key => Select the set value The LED beside the Prog key lights up. This means that the set value can now be modified with the Plus/Minus keys. Change the set value using the Plus/Minus keys. Press the Prog key => The modified value is saved.! Setting mode can be ended at any time by pressing the Plus and Minus keys simultaneously. Changes which have been entered but not stored by pressing the Prog key have no effect. prog Exit from the operating level by pressing the Plus and Minus keys simultaneously. Set values protected by code no. (from No. 20) It is only possible to change the set values from no. 20 after entering the code number. These set values may only be modified by an authorized fitter. E If these values are set incorrectly, they may cause malfunctions or damage to the system. Select set value 20 (code no. input). Press the Prog key and enter the 1 to 4-digit code number. Confirm each digit by pressing the Prog key. Select the set value to be modified. Press the Prog key and change the set value. Conclude the input by pressing the Prog key. If an attempt is made to enter an impermissible value, the system automatically returns to set value 20 (enter code number). 7

Set values list Set values list Explanatory information No. Designation Setting range Setting ex works Own settings User set values 01 Set time 0.00 24.00 10.00 02 Set weekday 1 7 1 (Monday) 03 Day's production Display only /Clear 0 04 Total production Display only /Clear 0 05 Pump kick function switch-on time 00.00 24.00 07.00 06 Pump kick function switch-off time 00.00 24.00 22.00 07 Reheating function ON 00.00 24.00 05.00 08 Reheating function OFF 00.00 24.00 21.00 Fitter set values 20 Enter code no. 0000-9999 21 Code no. 0000-9999 0000 22 Select system (see hydraulic diagrams) 1-7 1 Switching thresholds / Hystereses 30 Switching threshold for difference 1 1K 30K 3K 31 Hysteresis to switching threshold for 1 1K 10K 3K 32 Switching threshold for difference 2 1K 30K 3K 33 Hysteresis to switching threshold for 2 1K 10K 3K 8

Explanatory information Set values list No. Designation Setting range Setting ex works Own settings Special functions 40 Enable temperature, collector(s) (-20) C (+90) C 35 C 41 Maximum collector temperature 80 C 180 C 110 C 42 Enable temperature 2nd heat generator 0 C 90 C 60 C / 40 C [6] 43 Maximum solid fuel boiler temperature: 30 C 130 C 90 C 50 Maximum storage tank temperature, tank 1 10 C 130 C 60 C 51 Maximum storage tank temperature, tank 2 10 C 130 C 85 C 52 Tolerance for solar production (System 6 only) 0 C 90K 10K 53 Hot water short time heating function 0, 1 (OFF, ON) 0 (OFF) Pump kick function (temperature test function) 60 Kick duration 0.2s 59s 0 = OFF 61 Kick pause 10 min 60 min 30 min 62 Measuring time for 0.5K increase 1 min 5 min 1 min Production estimate/volume flow counter 70 Pulse rate [milliliter/pulse] or [liter/pulse] 0 100 1.1 71 Pulse rate unit (0=ml/pulse; 1=l/pulse) 0.1 0 (ml/pulse) 72 Volume flow distribution with 2 collector system 1:99 99:1 50:50 75 Volume flow fix for collector 1 [liter/min] 0-100 0.0 = OFF 76 Volume flow fix for collector 2 [liter/min] 0-100 0.0 = OFF 78 Mixing ratio 0 70 vol. % 40 % 79 Glycol type 0 1 0 9

Explanation of the set values / functions of the set values / functions Explanation of the set values / functions In order to modify the standard settings, refer to the chapter "Electrical connections", select the relevant system according to the hydraulic systems illustrated and define these settings first of all [P22]. The chapter "Explanation of set values / functions" describes the various set values according to their dependence on the selected/realized system (1-7). If the controller, e.g. for System 1 is used, only refer to the function descriptions related to this system. User set values 01 Set time All systems: Set the current time. (Indicators, pump kick function and reheating function.) 02 Weekday All systems: Set the current weekday (1-7, 1=Monday) (Display only) Resetting the production indicators Explanatory information 03 Day's production indicator System 1, 3, 4, 5, 6, 7 (System 2 -> no function): Reset the value to "0000" by pressing the Prog key Ä (for at least 2 seconds). The value is reset to "0000" at 24h. 04 Total production indicator System 1, 3, 4, 5, 6, 7 (System 2 -> no function): This value is updated at 24:00. => To determine the current total value accurately, the day's production value must be added to the "indicated" total production value. Reset the value to "0000" by pressing the Prog key Ä (for at least 2 seconds). Pump kick function (temperature test function) System 1, 3, 4, 5, 6, 7 (System 2 -> no function): The pump kick function can be executed during the time period of the day in which solar production is expected [P05-P06]. This function should ensure that the actual collector temperature can be measured by the collector sensor even when the collector pumps are not operating. The function is deactivated when P05=P06="----" or P60=0. 10

Explanatory information Explanation of the set values / functions Each time the kick pause [P61] has ended, the corresponding collector pump is activated for the period of the kick duration [P60] (heat transport to the sensor). If a temperature increase of 0.5K is detected on the respective collector sensor during the measuring period [P62], the collector pump is activated for one minute. Finally, the switch-on conditions for the collector pump are checked. 05 Pump kick function switch-on time (Refer to Chapter "Pump kick function") 06 Pump kick function switch-off time (Refer to Chapter "Pump kick function") Reheating function System 6 only (Systems 1, 2, 3, 4, 5, 7 -> no function): On selecting System 6, it is possible to enter a set temperature value [P42] for the storage tank. During the enable time [P07-P08], this temperature is set by activating an additional heat generator. The additional heat generator is activated when the set temperature falls P42 below the hysteresis P33. It is deactivated when the set temperature P42 is reached. 07 Reheating function ON (Refer to Chapter "Reheating function") 08 Reheating function OFF (Refer to Chapter "Reheating function") Fitter set values 20 Enter code no. After entering the code number, the set values assigned to the fitter level can be modified. Standard value: 0000 21 Valid code no. The code number currently valid can be modified with this setting. (Value only visible after entering the currently valid code no.) 22 System selection (see appended diagrams) On selecting the system, the function of the device is redefined. Set the system number according to the connection descriptions (System 1 System 7).! After changing the System Selection parameter, all the set values are reset to the default factory values (including the code no.). The fitter level is closed. 11

Explanation of the set values / functions Switching thresholds / Hystereses 30 Switching threshold for difference 1 System 1, 2, 3, 4, 5, 6, 7: The feeding function for storage tank I via pump A1 is activated when the temperature difference between sensor F1 (collector) and sensor F4 (bottom of tank) has exceeded the temperature [switching threshold + hysteresis = P30+P31]. The feeding function for storage tank I is deactivated when the difference falls below the set switching threshold. 31 Hysteresis to switching threshold for difference 1 (See P30) 32 Switching threshold for difference 2 Systems 1, 2, 6: No function Systems 4, 3: The feeding function via pump A2 is activated when the temperature difference between sensor F2 (solid fuel / collector II) and sensor F4 (bottom of tank) has exceeded the temperature [switching threshold + hysteresis = P32+P33]. The feeding function is deactivated when the difference falls below the set switching threshold. Explanatory information System 5: The feeding function for storage tank II via pump A1 is activated when the temperature difference between sensor F1 (collector) and sensor F3 (storage tank II) has exceeded the temperature [switching threshold + hysteresis = P32+P33]. The feeding function for storage tank II is deactivated when the difference falls below the set switching threshold. The valve A2 is switched in the direction of storage tank II when the feeding function for storage tank II is enabled and storage tank I cannot be fed. System 7: The discharging function via valve A2 is activated when the temperature difference between sensor F2 (heating system return flow) and sensor F4 (bottom of tank) has exceeded the temperature [switching threshold + hysteresis = P32+P33]. If a sensor F3 (top of tank) is connected, this sensor is used, instead of F4, to evaluate the difference. The charging function is deactivated when the difference falls below the set switching threshold. 33 Hysteresis to switching threshold for difference 2 (See P32) 12

Explanatory information Explanation of the set values / functions Special functions 40 Enable temperature, collector System 1, 3, 4, 5, 6, 7 (System 2 -> no function): The collector pump is activated when the associated collector temperature exceeds the limit value set here by 5 K. It is stopped when the collector temperature falls below the threshold temperature. This function prevents the pumps continuing to run when no relevant heat production is required. 41 Maximum collector temperature System 1, 3, 4, 5, 6, 7 (System 2 -> no function): The collector pumps are deactivated when the related collector temperatures exceed the safety limits set here. -> System protection The pumps are reactivated when the temperature falls below the temperature [maximum collector temperature 10K]. 42 Enable temperature of 2nd heat generator (solid fuel) System 1, 4, 5, 7: No function Systems 2, 3: The relevant pumps are activated when the temperature of the 2nd heat generator (System 2 = F1, System 3 = F2) exceeds the limit value set here by 5K. It is stopped when the temperature of the heat generator drops below the enable temperature. This function ensures that the heat generator can reach its operating temperature. System 6: The 2nd heat generator (A2) is enabled when the storage tank temperature at F3 falls 5K below the limit temperature set here. It is stopped when the temperature of the storage tank exceeds the enable temperature. 43 Maximum solid fuel boiler temperature Systems 1, 4, 5, 6, 7: No function Systems 2, 3: The charge pump of the solid fuel boiler is deactivated when the temperature of the boiler exceeds the limit temperature set here. -> System protection. The pump is reactivated when the, temperature falls 10 K below the limit value. 13

Explanation of the set values / functions 50 Maximum storage tank temperature, tank I E If a top of tank sensor (F3) is mounted, it is used to monitor the maximum temperature. If this sensor is not installed, the maximum storage tank temperature is monitored by F4. In this case, the tank covering must be taken into account. System 1, 2, 3, 4, 6, 7: The charge pumps are deactivated when the temperature of storage heater I exceed the safety limit temperature set here.-> System protection The pumps are reactivated when the temperature falls below the temperature [maximum storage tank temperature 5K]. System 5: The valve A2 is set towards the second storage heater (relay A2 closes) when the temperature of the first storage heater exceeds the safety limit set here. The mixer closes again (relay opens) when the temperature falls below the temperature [maximum storage tank temperature 5K]. 51 Maximum storage tank temperature, tank II System 5 only (Systems 1, 2, 3, 4, 6, 7 -> no function): Charge pump A1 is stopped when the temperature of storage heater II exceeds the safety limits set here and Explanatory information storage tank I cannot be fed (A2 set towards storage tank II). -> System protection The pump is reactivated when the temperature falls below the temperature [maximum storage tank temperature 5K]. 52 Tolerance with solar production System 6 only (Systems 1, 2, 3, 4, 5, 7 -> no function): If the storage tank is fed from the collector (A1 = ON), the additional heat generator is only activated when the storage tank temperature falls below the set temperature P42 by the value [tolerance amount + P33]. It is deactivated again when the storage tank temperature has reached the value [set temperature P42 tolerance value]. 14

Explanatory information Explanation of the set values / functions Hot water short time heating function System 6 only (Systems 1, 2, 3, 4, 5, 7 -> no function): Each Saturday at 1:00 a.m., the storage tank is heated to 65 C in a one-off action. This function is only performed when the storage tank temperature of 65 C was not reached during the previous week. The temperature is monitored by sensor F4 "bottom of storage heater". The hot water short time heating function is stopped when the set temperature cannot be reached within 3 hours or when the programmed maximum storage temperature (at least 65 C) is detected at sensor F3 (only when installed). E The hot water short time heating function can only be successfully performed when the external heat generator (reheating function) is capable of generating the corresponding temperatures. Hot water short time heating function 53 0 = Function not active (standard) 1 = Function active Pump kick function (temperature test function) System 1, 3, 4, 5, 6, 7 (System 2 -> no function): 60 Kick duration [sec] Collector pump runtime following pump kick. 61 Kick pause [min] If the collector pump has not run for the duration set here, the pump is activated for the kick duration period [P 60]. 62 Measuring time for 0.5 K increase [min] The course of the collector temperature is controlled during this period following a pump kick. If an increase of 0.5K is detected, the pump is started for a further minute. Production estimate / Volume flow counter System 1, 3, 4, 5, 6, 7 (System 2 -> no function): While collector pump is running, the pulses of an optionally connectable flow rate counter can be evaluated (see Connection Plan: Pulse). The controller can calculate the solar heat production from the volume flow established (entry of the counter pulse rate in P70) and the temperature difference F1 to F4. 15

Explanation of the set values / functions! Systems 1, 5, 6: If the sensor F2 is installed as a return flow sensor for the collector in these systems, the temperature difference between F1 F2 is calculated.! System 4: In the case of System 4, the calculation is made for both collectors according to the heat production. If both collector pumps are in operation, the heat flows are calculated according to the ratio of the volume flows [P72]. For the calculation, the heat transport medium used in the system (glucol type = P79) and the mixture ratio with water [P78] must be set. The day's production and total production are displayed in [kwh]; in the case of values in excess of 10 MW, the display of the total production changes to [MWh]. The change is indicated in the display by means of three arrows. The day's production is reset to zero at midnight. Both values can be reset to zero at user level by means of the Prog key.! If no pulse counter is connected, a production estimate can be executed. To do this, enter the average volume flow through the respective collector when the charging pump is in operation [P75+P76]. The volume flow can be established by installing a counter for a short time or by calculation (installation technician). Explanatory information Guideline for volume flow quantity: Approx. 0.8 [l / min] sq. meter of collector surface. E Caution! This value does not apply to low flow systems. 70 pulse rate [milliliter/pulse] [liter/pulse] (Only with volume flow counter) Refer to the flow rate counter documents for the pulse rate of the counter connected (option). 71 Set pulse rate unit (Only with volume flow counter) Switching between [ml/pulse] and [l/pulse]. 72 Volume flow distribution with 2 collector system (System 4 only): Enter the ratio of the volume flows through the two collectors in case both charging pumps are in operation. 75 Volume flow fix for collector 1 [liter/min] (Only without volume flow counter - see "Production estimate") 76 Volume flow fix for collector 2 [liter/min] (Only without volume flow counter - see "Production estimate") 16

Explanatory information Other functions 78 Mixture ratio System 1, 3, 4, 5, 6, 7 (System 2 -> no function): Refer to the documents supplied for information on the mixture ratio of the heat transport medium (filling of the solar energy system) or ask the installation technician. 79 Glycol type Systems 1, 3, 4, 5, 6 (System 2 -> no function): (Solar-electricity system documents / installation technician) 0 = Propylene glycol 1 = Ethylene glycol Other functions Pump blocking protection The controller effectively prevents the pumps blocking following longer periods out of operation. The integrated protection function activates all the pumps which have not operated within the last 24 hours each day for approx. 5 seconds between 12:00 and 12:01. Stop pumps (temperature control) (System 5 only) Filling of the secondary storage tank (sensor F3) is interrupted for 60 sec. every 30 minutes. After the interruption period, the start conditions for filling the primary storage tank (sensor F4) are checked. This function is only executed when the highest priority storage tank has not reached its maximum storage tank temperature [F4 < (P50-5K)]. 17

For the fitter Electrical connection Electrical connection For the fitter! Sensor: The KLF 1000 must be used (silicone cable) as the collector sensor. The SPF 1000 can be used as well for all other applications. 11 12 13 14 15 16 17 18 19 20 T1 T2 H A1 N1 N2 N L1 Z L1 A2 Z v F1 Impuls Pulse 2 F2 F3 F4 10 9 8 7 6 5 4 3 2 1 ~50 Hz 230 V 2(2)A, 250V~ Sensors E Attention: For the connection (230 V) fixed or flexible lines with the factory-standard lead end sleeves are to be installed. E Attention: Bus lines and sensor lines are to be installed separately from supply lines! 18

For the fitter Electrical connection System 1 230V ; Switching capacity of relays 2(2)A, 250V Mains power: 20 Supply to device and pump A1 19 N-conductor for device 17 N-conductor for collector pump (A1) 16 Supply connected to collector pump L1 (A1) Sensors: 1+7 Collector sensor (F1) 4+5 Sensor, bottom of storage tank (F4) Optional: 2+6 Return flow sensor for production indicator (F2) 3+6 Sensor, top of storage tank (F3) 7+8 Pulse input for volume flow counter Switching conditions for A1 (P = set value): Heat production difference to storage tank and min. temp.: ON: F1 - F4 > P30 + P31 and F1 > P40 + 5K OFF again: F1 - F4 < P30 or F1 < P40 Maximum storage tank temperature: OFF: F4 > P50 ON again: F4 < P50-5K Maximum collector temperature: OFF: F1 > P41 ON again: F1 < P41-10K Sensor => F1+F2: KLF1000; F4+F3: SPF F1 (F3) A1 F4 (F2) Impuls Pulse 19

Electrical connection For the fitter System 2 230V ; Switching capacity of relays 2(2)A, 250V Mains power: 20 Supply to device and pump A1 19 N-conductor for device 17 N-conductor for solid fuel boiler charging pump (A1) 17 Supply connected to solid fuel boiler charging pump L1 (A1) Sensors: 1+7 Sensor, solid fuel boiler (F1) 4+5 Sensor, bottom of storage tank (F4) Optional: 3+6 Sensor, top of storage tank (F3) Switching conditions for A1 (P = set value): Heat production difference to storage tank and min. temp.: ON: F1 - F4 > P30 + P31 and F1 > P42 + 5K OFF again: F1 - F4 < P30 or F1 < P42 Maximum storage tank temperature: OFF: F4 > P50 ON again: F4 < P50-5K Maximum solid fuel boiler temperature: OFF: F1 > P43 ON again: F1 < P43-10K 20 Sensor => F1: KLF1000; F3+F4: SPF F1 A1 (F3) F4

For the fitter Electrical connection System 3 230V ; Switching capacity of relays 2(2)A, 250V Mains power: 20 Supply to device and pump A1 19 N-conductor for device 18 N-conductor for solid fuel boiler charging pump (A2) 17 N-conductor for collector pump (A1) 16 Supply connected to collector pump L1 (A1) 12 Supply connected to solid fuel boiler charging pump L1 (A2) 11 Supply for pump (A2) (e.g. bridge to 20) Sensors: 1+7 Collector sensor (F1) 2+6 Sensor, solid fuel boiler (F2) 4+5 Sensor, bottom of storage tank (F4) Optional: 3+6 Sensor, top of storage tank (F3) 7+8 Pulse input for volume flow counter Switching conditions for A1 (P = set value): Heat production difference to storage tank and min. temp.: ON: F1 - F4 > P30 + P31 and F1 > P40 + 5K OFF again: F1 - F4 < P30 or F1 < P40 Maximum storage tank temperature: OFF: F4 > P50 ON again: F4 < P50-5K Maximum collector temperature: OFF: F1 > P41 ON again: F1 < P41-10K Switching conditions for A2: Heat production - difference to tank and min. temp.: ON: F2 - F4 > P32 + P33 and F2 > P42 + 5K OFF again: F2 - F4 < P32 or F2 < P42 Maximum storage tank temperature: OFF: F4 > P50 ON again: F4 < P50-5K Maximum solid fuel boiler temperature: OFF: F2 > P43 F1 ON again: F2 < P43-10K Sensor => F1+F2: KLF1000; F4+F3: SPF F2 A2 (F3) F4 Impuls Pulse A1 21

Electrical connection For the fitter System 4 230V ; Switching capacity of relays 2(2)A, 250V Mains power: 20 Supply to device and pump A1 19 N-conductor for device 18 N-conductor for collector pump (A2) 17 N-conductor for collector pump (A1) 16 Supply connected to collector pump L1 (A1) 12 Supply connected to collector pump L1 (A2) 11 Supply for pump (A2) (e.g. bridge to 20) Sensors: 1+7 Collector sensor (F1) 2+6 Collector sensor (F2) 4+5 Sensor, bottom of storage tank (F4) Optional: 3+6 Sensor, top of storage tank (F3) 7+8 Pulse input for volume flow counter Switching conditions for A1 (P = set value): Heat production difference to storage tank and min. temp.: ON: F1 - F4 > P30 + P31 and F1 > P40 + 5K OFF again: F1 - F4 < P30 or F1 < P40 Maximum storage tank temperature: OFF: F4 > P50 ON again: F4 < P50-5K Maximum collector temperature: OFF: F1 > P41 ON again: F1 < P41-10K Switching conditions for A2: Heat production difference to storage tank and min. temp.: ON: F1 - F4 > P32 + P33 and F1 > P40 + 5K OFF again: F1 - F4 < P32 or F1 < P40 Maximum storage tank temperature: OFF: F4 > P50 ON again: F4 < P50-5K Maximum collector temperature: OFF: F1 > P41 ON again: F1 < P41-10K Sensor => F1+F2: KLF1000; F4+F3: SPF (F3) F4 F1 Pulse Impuls A1 F2 A2 22

For the fitter Electrical connection System 5 230V ; Switching capacity of relays 2(2)A, 250V Mains power: 20 Supply to device and pump A1 19 N-conductor for device 18 N-conductor for reversing valve (A2) 17 N-conductor for collector pump (A1) 16 Supply connected to collector pump L1 (A1) 12 Supply connected to reversing valve L1 (A2) 11 Supply for reversing valve (A2) (e.g. bridge to 20) Sensors: 1+7 Collector sensor (F1) 4+5 Sensor, bottom of storage tank I (F4) 3+6 Sensor, bottom of storage tank II (F3) Optional: 2+6 Return flow sensor for production indicator (F2) 7+8 Pulse input for volume flow counter Switching conditions for A1 (P = set value): Heat production difference to storage tank and min. temp.: ON: F1 - F4 > P30 + P31 and F1 > P40 + 5K or F1 F3 > P32 + P33 and F1 > P40 + 5K OFF again: F1 - F4 < P30 and F1 F3 < P32 or F1 < P40 Maximum storage tank temperature: OFF: F4 > P50 and F3 > P51 ON again: F4 < P50-5K or F3 < P51-5K Maximum collector temperature: OFF: F1 > P41 ON again: F1 < P41-10K Switching conditions for A2: Maximum storage tank temperature: ON: A1 = ON and F4 > P50 or A1 = ON and F1 - F4 < P30 OFF again: A1 = OFF or F4 < P50-5K or F1 - F4 > P30 + P31 Sensor => F1+F2: KLF1000; F4+F3: SPF F1 F3 2 D F4 1 F A2 ON OFF (F2) Pulse Impuls A1 23

Electrical connection For the fitter System 6 230V ; Switching capacity of relays 2(2)A, 250V Mains power: Heat generator contact potential-free 20 Supply to device and pump A1 19 N-conductor for device 17 N-conductor for collector pump (A1) 16 Supply connected to collector pump L1 (A1) 12 T1 for boiler request (A2) 11 T2 for boiler request (A2) Mains power: Heat generator contact, potential linked 230V 20 Supply to device and pump A1 19 N-conductor for device 18 N-conductor for additional heating (A2) 17 N-conductor for collector pump (A1) 16 Supply connected to collector pump L1 (A1) 12 Supply connected to additional heating L1 (A2) 11 Supply for additional heating (A2) (e.g. bridge to 20) Sensors: 1+7 Collector sensor (F1) 4+5 Sensor, bottom of storage tank (F4) 3+6 Sensor, top of storage tank (F3) Optional: 2+6 Return flow sensor for production indicator (F2) 7+8 Pulse input for volume flow counter Switching conditions for A1 (P = set value): Heat production difference to storage tank and min. temp.: ON: F1 - F4 > P30 + P31 and F1 > P40 + 5K OFF again: F1 - F4 < P30 or F1 < P40 Maximum storage tank temperature: OFF: F4 > P50 ON again: F4 < P50-5K Maximum collector temperature: OFF: F1 > P41 ON again: F1 < P41-10K Switching conditions for A2 (P=Parameter): Heat production fallen below set temperature: No solar production: A1 = OFF: ON: F3 < P42 P33 OFF again: F3 >= P42 With solar production: A1 = ON: ON: F3 < P42 P52 P33 OFF again: F3 >= P42 P52 Sensor => F1+F2: KLF1000; F4+F3: SPF 24

For the fitter Electrical connection System 6: F1 A2: ON/OFF F3 F4 (F2) Impuls Pulse A1 25

B Electrical connection For the fitter System 7 230V ; Switching capacity of relays 2(2)A, 250V Mains power: 20 Supply to device and pump A1 19 N-conductor for device 18 N-conductor for reversing valve RLA (A2) 17 N-conductor for collector pump (A1) 16 Supply connected to collector pump L1 (A1) 12 Supply connected to reversing valve L1 (A2) 11 Supply for reversing valve RLA (A2) (e.g. bridge to 20) Sensors: 1+7 Collector sensor (F1) 2+6 Return flow sensor, heating system (F2) 4+5 Sensor, bottom of storage tank (F4) Optional: 3+6 Sensor, top/middle of storage tank (F3) 7+8 Pulse input for volume flow counter Switching conditions for A1 (P = set value): Heat production difference to storage tank and min. temp.: ON: F1 - F4 > P30 + P31 and F1 > P40 + 5K OFF again: F1 - F4 < P30 or F1 < P40 Maximum storage tank temperature: OFF: F4 > P50 26 ON again: F4 < P50-5K Maximum collector temperature: OFF: F1 > P41 ON again: F1 < P41-10K Switching conditions for A2: Return flow temperature increase (without F3): ON: F4 > F2 + P32 + P33 OFF again: F4 < F2 + P32 Return flow temperature increase (with F3): ON: F3 > F2 + P32 + P33 OFF again: F3 < F2 + P32 Sensor => F1+F2: KLF1000; F4+F3: SPF AFS r T1 T2 2 2 2 KFS 3 D 1 4 2 3 VFAS D 2 v 2 D 2 K (F3) A2 F2 F4 OFF ON F1 Impuls Pulse A1

Sensors For the fitter Sensors F1 + F2: KLF 1000: collector sensor without spring; silicone cable 2.5 m; PT1000 sensor with 1 kω +/- 0.2% at 0 C: F3 + F4: SPF: Storage tank sensor with spring; PVC cable, 3.0 m; NTC sensor with 5 kω +/- 1% at 25 C: Temperature in C Resistance in Ω -20 922-10 961 0 1,000 10 1,039 20 1,078 30 1,118 40 1,155 50 1,194 60 1,232 70 1,270 80 1,309 90 1,347 100 1,385 110 1,422 120 1,460 Temperatures in C Resistance in Ω -20 48.535-10 27.665 0 16.325 10 9.950 20 6.245 30 4.029 40 2.663 50 1.802 60 1.244 70 876 80 628 90 458 100 339 110 255 120 194 27

Technical data Technical data Supply voltage complying with DIN IEC 60 038 Power consumption Switching capacity of the relays Maximum current on terminal L1' Type of protection complying with DIN EN 60529 Protection class complying with DIN EN 60730 Power reserve of the timer Permitted ambient temperature during operation Permitted ambient temperature for storage Sensor resistances F1 and F2: F3 and F4: 230 V AC ± 10% Max 5 VA 250 V 2(2) A 6.3 A IP 40 Totally insulated > 10 hours 0 to 50 C -20 to 60 C Multiplier PT1000, 1KΩ +/- 0.2% at 0 C 5KΩ NTC +/- 1% at 25 C Error Error In case of an error the symbol E is displayed and the corresponding error number flashes. In order to reset the parameters to the default values press the three operating keys simultaneously. No. Designation Significance Sensor fault E 71 Collector sensor F1 defect The collector sensor has short circuited or there is an interruption. E 72 Storage tank sensor top F3 defect E 73 Storage tank sensor bottom F4 defect E 79 Additional sensor F2 defect E 81 EEprom Functional defects resulting from incorrect operation or settings are excluded from the terms of warranty. The storage tank sensor has short circuited or there is an interruption. The storage tank sensor has short circuited or there is an interruption. The additional sensor F2 has short circuited or there is an interruption. A fault has occurred in the EEprom. Please check values. EN 1104 6.6701.547-01 Printed in Germany All Rights Reserved 28