Air-Quality Detection Module. User s Manual

Similar documents
Air-Quality Detection Module. User s Manual

Intelligent Infrared Carbon Dioxide Module (Model: MH-Z14A)

MEMS Carbon Monoxide Gas Sensor. (Model No.:GM-702B) Manual. Version: 1.1. Valid from: Zhengzhou Winsen Electronics Technology Co.

Air-Quality Gas Sensor (Model: MP905) Manual. Version:1.1. Valid From: Zhengzhou Winsen Electronics Technology Co., Ltd

Smoke Sensor. (Model:MQ-2) Manual. Version: 1.4. Valid from: Zhengzhou Winsen Electronics Technology Co., Ltd

Catalytic Flammable Gas Sensor. (Model: MC105B) User s Manual. Version: 1.3. Valid from: Zhengzhou Winsen Electronics Technology Co.

Ammonia Gas Sensor. (Model:MQ137) Manual. Version: 1.4. Valid from: Zhengzhou Winsen Electronics Technology Co., Ltd

Ozone Gas Sensor. (Model:MQ131 High Concentration) Manual. Version: 1.4. Valid from: Zhengzhou Winsen Electronics Technology Co.

ZP04 Flammable Gas Detection Module (Model:ZP04) Manual V1.1. Zhengzhou Winsen Electronics Technology Co., Ltd

Catalytic Gas Sensor. (Model: MC113/ MC113C) Manual. Version: 1.3. Valid from: Zhengzhou Winsen Electronics Technology Co.

Manual Zhengzhou Winsen Electronics Technology Co., Ltd

Air-Quality Gas Sensor (Model:MP503) Manual. Version:1.3. Valid From: Zhengzhou Winsen Electronics Technology Co., Ltd

Intelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features.

Multifunction IAQ Monitor

The product can be worked together with our wireless controller to control a ventilator, air cleaning device, or

Web Site: Forums: forums.parallax.com Sales: Technical:

TECHNICAL DATA MQ-2 GAS SENSOR

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

M004 combustible gas module

KAE Gas Alarm Operation Manual

E1000 Portable gas detector

MS4525DO SPECIFICATIONS FEATURES APPLICATIONS

QAS SERIES PLUG-IN CONTROLLERS c/w SOLID STATE SENSOR

Installation and Wiring 1.

Blueair Pro User Manual

IMR EX610. Portable Gas Detector. Operation Manual

KAB Gas Alarm Operation Manual

TM-802 Formaldehyde Meter User s Manual

Web Site: Forums: forums.parallax.com Sales: Technical:

C-Bus Four Channel General Input Unit Installation Instructions

Web Site: Forums: forums.parallax.com Sales: Technical:

DESIGN MANUAL MODEL GIR900 INFRARED COMBUSTIBLE GAS SENSOR

BEP Marine Gas Detector FD-2

TOXIC GAS AND OXYGEN DETECTOR DTX 420 INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS DTX420_MAN01_EN_V1R2

CONTENTS CONTROLS 3-STAGE AIR PURIFICATION. X This product is suitable for 120V only. User Manual. Odor sensor. ➌ PlasmaWave

OX100/OX102. Limiting-current type Oxygen Analyzer. Bulletin 11M10A01-03E

Process Control PIP PCEA001 Fixed Gas Detection Guidelines

Model GD Instruction Manual. Combustible Gas Leak Detector. reedinstruments. www. com

MSP100 Pressure Transducer

Triple Action Humidifier Model: AW600

99 Washington Street Melrose, MA Phone Toll Free Visit us at

Installation & Operation

AT-G-SENSE Gas Sensing System

Datasheet: K-22 LO Sensor

2015 Amphenol Advanced Sensors. Jinton Industrial Park, Wujin, Changzhou, Jiangsu, China. Web:

Two-Channel Gas Controller

GAS MONITOR Model Model

Infrared Carbon Dioxide Sensor Module CM1107-Dual Beam

Owners Manual Model: XXL

Model VFM200. User Manual. Formaldehyde (HCHO or CH 2 0) and Total Volatile Organic Compounds (TVOC) Tester

NIDS Dust sensor ED-N-DS-1408

MODEL QTS-1800 SERIES WALL MOUNT DIGITAL AND ANALOG TRANSMITTER/SENSOR

Operation and Maintenance Manual

Setup instructions. Honeywell GAS DETECTOR. Overview. Accessories The instruction x1 Plug dowel x2 Screw x2 Double-sided adhesive tape x2

EST User Manual. (Please read this manual carefully before using)

Popcorn Warmer Cabinet

The MiCS-4514 is a compact MOS sensor with two fully independent sensing elements on one package.

Failure to comply with the following instructions may result in death or serious injury to

Sensor unit MC2 with analog output for Freon gases and refrigerants

AT8060 BREATH ALCOHOL TESTER USING MANUAL. Ver: HW Catalogue

86BSD Digital Output

BD Viper Lysing Heater Manual (for BD Viper System)

SP-220. Features. Combustible handheld gas leakage detector

PCD110X - Premium Choice with DC Motor (Ceiling Mounted Ventilation Fans)

QAS-101 SERIES SINGLE CHANNEL CONTROLLERS

6-1 Installing Batteries 6-2 Automatic Circuit/Reset Feature 6-3 Feature Sensitivity Adjustment

Model: AW600. Triple Action Humidifier. Winix Inc. 120 Prairie Lake Road U nit E East Dundee, IL USA

MS200/300/400 Hotplate Magnetic Stirrer Instruction Manual

SMART Dust Sensor. Amphenol Advanced Sensors SM-PWM-01C. Application Note. Features

WIRELESS GAS DETECTION & SHUT OFF SYSTEM INSTRUCTION MANUAL. Wireless Gas Detection & Shut Off System - User Manual & Instructions

SENSIT HXG-2. Instruction Manual For use with combustible gases Gas Leak Detector

Ionizer (Static Remover) STABLO-EX Instruction Manual

ELIMINOSTAT DC-ESR-CL-S2

HDCVI PIR Camera User s Manual

MS4525 SPECIFICATIONS

IGD.CO.UK

Infrared Carbon Dioxide Sensor Module CM1106SL

1040 Gas Monitor INSTALLATION AND OPERATING INSTRUCTIONS AMC-1040 WITH INTEGRAL ELECTROCHEMICAL SENSOR

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.

user manual Version 12/2015 Excellent Business Conditions.

SMART dust sensor for air purifier Description SM-ND-02A SM-ND-02A is a dust sensor that detects the dust particle concentration in air by using optic

The MiCS-5524 is a compact MOS sensor.

PROFESSIONAL DRIVER FATIGUE MONITOR

GD Series Gas Alarm Operation Manual

DOG2 MEMS SERIES CAN J1939 INCLINOMETER

portable gas analyser

PERFORMANCE SLIMMING BELT

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

CARBON MONOXIDE CO SS SOLID STATE ELECTROCHEMICAL SENSORS

Room air quality sensors

NGD8800 USER S MANUAL

i-cube Microplate Incubator E10030

INSTRUCTION MANUAL P Heating and 1 Cooling

Register your product and get support at AC4091. User manual

OLCT 10N. Digital Gas Detector. User Manual. The Fixed Gas Detection Experts. Part Number: NPO10NEN Version: G.1

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD

Issue C. Installation Instructions for the Basic Amplified Board Mount Pressure Sensors, ABP Series

86BSD Digital Output

Toxic Gas Detection. Model F12. Toxic Gas Detection

Addressable Fire Alarm Control System 2100 series

Transcription:

Air-Quality Detection Module (Model:ZP01-MP503) User s Manual Version: 1.4 Valid from 2014-11-01 Zhengzhou Winsen Electronics Technology Co., Ltd ISO9001 Certificated Company

Statement This manual s copyright belongs to Zhengzhou Winsen Electronics Technology Co., LTD. Without the written permission, any part of this manual shall not be copied, translated, stored in database or retrieval system, also can t spread through electronic, copying, record ways. Thanks for purchasing our product. In order to let customers use it better and reduce the faults caused by misuse, please read the manual carefully and operate it correctly in accordance with the instructions. If users disobey the terms or remove, disassemble, change the components inside of the sensor, we shall not be responsible for the loss. The specific such as color, appearance, sizes &etc., please in kind prevail. We are devoting ourselves to products development and technical innovation, so we reserve the right to improve the products without notice. Please confirm it is the valid version before using this manual. At the same time, users comments on optimized using way are welcome. Please keep the manual properly, in order to get help if you have questions during the usage in the future. Zhengzhou Winsen Electronics Technology CO., LTD. May 1 st, 2014

Zhengzhou Winsen Electronics Technology Co., Ltd www.winsentech.com ZP01-MP503 Air-Quality Detection Module Product Description ZP01-MP503 air-quality module adopts flat surface semiconductor gas sensor. The module has very high sensitivity to volatile organic gases such as formaldehyde, benzene, carbon monoxide, ammonia, hydrogen, alcohol and smoke of cigarette, essence &etc. The module has been aging, debugged, adjusted and calibrated. So it has good consistency and high sensitivity. Features High sensitivity and good long-term stability Low power consumption, long life Calibrated before shipment 10 seconds to 3 minutes with auto-preheating function Faulty auto-check High cost-effective Application Air cleaner, fresh-air system, intelligent integrated ceiling, air quality monitor, ventilator, air-condition. Leading gas sensing solutions supplier in China

Zhengzhou Winsen Electronics Technology Co., Ltd www.winsentech.com Parameters Model ZP01-MP503 Sensor Air quality sensor formaldehyde, benzene, carbon Target Gas monoxide, hydrogen,alcohol, ammonia, smoke of cigarette, essence &etc. Physical Interface XH2.54-4P terminal sockets Output Data 0-3 grade pollution signal Working Voltage 5.0±0.2V DC (No voltage reverse connect protection) Output Data TTL level (200ohm protected resistance inside) Working Current 60mA Warm Up Time 3 min Response Time 20s Recovery Time 60s Operating Temperature 0~50 Operating Humidity 95%RH Storage Temperature -20~60 Storage Humidity 60%RH Size 24 20 15mm(L W H) Weight 20g Sensitivity Attenuator 1%/year Life Span 5 years Sensitivity Characteristics Contrast of the sensitivity in different gases Leading gas sensing solutions supplier in China

Zhengzhou Winsen Electronics Technology Co., Ltd www.winsensor.com Application of schematic diagram Pin definition Output Signal Pin Name Function 1 GND Input power - 2 5V Input power + 3 A Output A 4 B Output B Cautions Grade Output A Output B Pollution Grade 0 0V 0V Clean 1 0V +5V Light pollution 2 +5V 0V Moderate pollution 3 +5V +5V Severe pollution Please do not put the module in organic solvent (include silica gel and other cementing compound), painting, medicament, oils and fuels, high concentration gas etc. Please do not impact or vibrate the module seriously. Please warm up for 5 min before first use. Please do not use the module related with personal safety. Please do not install the module in the severe convection environment. Please do not put in the module in high concentration organic gas for long time. Note: To keep continual product development, we reserve the right to change design features without prior notice.