AND ARCHITECT SPECIFICATIONS

Similar documents
AND ARCHITECT SPECIFICATIONS

AND ARCHITECT SPECIFICATIONS

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

Conventional Releasing Control Panel

Specification/ Data Sheet

AND ARCHITECT SPECIFICATIONS

Advanced Protection System

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA

LifeAlarm Fire Alarm Control Panels

Addressable Fire Alarm Control Panel

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

good things in small packages

CONVENTIONAL FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels MEA. Features. Description

30.45 Electric Release PDRP-2001

AL800ULADA. NAC Power Extender. Installation Guide

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

AEGIS FEATURES DESCRIPTION. Conventional Fire Alarm-Suppression Control Unit. Effective: March Programmable Relays

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

MR-2602 Two Zone Fire Alarm Control Panel

SP40S-D. Kingfisher Company, inc. Features: Description:

Installation Instructions Model HZM

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K

Release Control Fire Alarm Systems

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

Fire Safety. Installation Instructions Model SMB-2 Main Control Board OPERATION INSTALLATION

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual

July 14, 1999 DF C-100.

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH SHP-PRO CONTROL PANEL

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

ECC-50/100C. Emergency Command Center

AL600ULADA. NAC Power Extender. Installation Guide

SPECIFICATION FOR A TOTAL FLOOD ECARO-25 TM CLEAN AGENT FIRE SUPPRESSION SYSTEM FOR USE WITH THE SHP PRO CONTROL PANEL SYSTEM

Cerberus TM PRO Fire Safety System A comprehensive fire-protection system

TECHNICAL DATA OBSOLETE

MS Rev. 2/DACT-UD: Intelligent Addressable FACP with Optional 2nd Loop

AL1002ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

DS7400Xi Addressable Control/ Communicator

FireSeeker Fire Alarm Control Panel Model FS-100 Installation, Operation, and Maintenance Manual

SPECIFICATION FIKE CLEAN AGENT FIRE SUPPRESSION SYSTEM WITH IMPUSLE VALVE, Fike FK AGENT & SHP PRO CONTROL PANEL

LifeAlarm Fire Alarm Controls

Desigo TM Fire Safety System A comprehensive fire-protection system

AL1042ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Installation Manual CFP-105. Fire Alarm Control Panel. Version 1.0

TrueAlert Addressable Notification Appliances

NETWORK FIRE ALARM CONTROL PANEL. Features

AL1042ULADA. NAC Power Extender. Installation Guide (See Application Guide for additional information) Rev

INTELLIGENT FIRE ALARM CONTROL PANEL

TrueAlert Addressable Notification Appliances

IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide

- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep.

Across-the-Line SERIES MP300 Combined Manual and Automatic

June 10, 2002 DF C S2424

Remote NAC Power Supply D7038

Air Duct Housings. Description

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH CHEETAH Xi 50 CONTROL PANEL

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS

EVO192 v3.0 Fire and Burglary What s New

4007ES Fire Control Panels

D7024 Fire Alarm Control Panel

SECTION TOTAL FLOODING ECARO-25 CLEAN AGENT FIRE EXTINGUISHING SYSTEM

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

ORENA BRAND CONVENTIONAL (ORENA Brand) CE

TrueAlarm Fire Alarm Controls

SPECIFICATION FOR A TOTAL FLOOD ECARO-25 TM CLEAN AGENT FIRE SUPPRESSION SYSTEM FOR USE WITH THE CHEETAH Xi 50 CONTROL PANEL SYSTEM

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM. Features

FireSeeker Fire Alarm Control Panel Model FS-250 Installation, Operation and Maintenance Manual

SECTION FIRE ALARM SYSTEMS

FMR Installation Instructions. Addressable Fire System Controller

SAFEPATH Mass Notification System (SPMNS)

Booster Power Supply Manual

FIREFORCE 8 NOTIFICATION APPLIANCE CIRCUIT EXPANDER INSTALLATION & OPERATION MANUAL

Soft Start Series MP700 Solid State, Reduced Voltage

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

Commercial and Light Industrial Fire Alarm Control Panel

Cerberus PRO A comprehensive fire-protection system

RE 2554 RE Automatic Fire Alarm Control Panel (Protective premises Unit) Installation, Commissioning & Operating User Manual

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5

FireNET Plus Wiring Instructions

MPC-6000 / MPC-7000 / RND-2

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

FIRE ALARM SYSTEM 1.1 GENERAL REQUIREMENTS

Intelligent Single Loop Fire Alarm Control Panel

Installation Instructions Model ABHW-4S

"SS90" SERIES CONTROLS MODEL C INSTALLATION MANUAL

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2

Project No Belleville Fire Hall/Headquarters and Emergency Operations Centre Section Belleville, Ontario Page 1 of 10

Doc. No Part No Rev. U * T*

POWERPATH PS-8 (105531) PS-8E (100263) PS-6 (105530) PS-6E (100262)

FW106 Fire Alarm Control Panel

Addressable NAC Output Module D327A

XP6-C. Six Circuit Supervised Control Module and SYNC-1 Accessory Card

Transcription:

PXL Conventional Zone Fire Alarm Control Panel ENGINEER AND ARCHITECT SPECIFICATIONS 12 Zone System Expandable to 32 10 Amp Base Power Supply Multiple Power Supplies Available - Local or Remote 4 Notification Appliance Circuits in Base System - Expandable to 16 2 Amp, Power Limited Notification Appliance Circuits Easy to Use, ATM-type Display for Operation and Programming with 80 LCD Character On-line Help Text for All System Operations Factory Programmed - Ready to Install Fully Field Programmable Options - No Programming Tools Required Compatible with Cerberus Pyrotronics Conventional Initiating Devices and Notification Appliances Sprinkler Supervisory Service with Dedicated Relay Output Alarm Verification by Zone 150 Event History One Person Test Feature Zone and Output Bypass Password Protection Listed, ULC Listed, CSFM & NYMEA Approved, FM Pending Introduction The PXL from Cerberus Pyrotronics is a conventional fire alarm control panel designed to meet the changing needs at the core of the fire alarm market. While providing basic fire protection in a flexible architecture, it also uses technology designed for other markets to speed installation and to simplify the response to fire. Combined with Cerberus Pyrotronics smoke detectors, which long ago established a standard for quality in the industry, PXL fire alarm controls are the most reliable and easy to use systems available today. Description The PXL basic system consists of a microprocessor based control with 12 alarm initiating circuits. At the heart of the system s flexible architecture is a 10 amp power supply with a 2 amp battery charger. Although this supply is included in the base PXL it can also be reproduced in the system. The power supply includes 3 relays which are automatically activated in the event of fire alarm, supervisory conditions, or trouble conditions - one relay for each type of condition. Additionally, the power supply includes four notification appliance circuits, each rated at 2 amps. These features CATALOG NUMBER 8100

supply the power required to answer today s needs for signaling devices and remote communication of system conditions. System status is reported on a 4 line LCD display in a format similar to an automated teller machine. The system user can quickly identify the condition of the facility by viewing this display and/or individual zone LED s. Proper response to conditions is indicated in the display by clear, easy to read messages which highlight the correct buttons to press. When the user is confronted with multiple functions which can be performed at the same time the system simply leads him or her to the most critical functions first. This same display is used for system programming. The entire system, including many of the desirable software features available in today s systems, can be programmed through this display without the need for a computer or other programming tools. Further, most installers can program all of these features without any training. Expansion The basic PXL can be expanded conveniently to 32 zones, 32 relays and 16-2 amp notification appliance circuits supported by two power supplies. A larger enclosure or multiple standard enclosures are required. Enclosures Two enclosures sizes are available for the PXL. The Model PSE-1 includes a single module mounting bracket which can support one PZE-4B, in addition to the main control, for a total of 16 initiating circuits. The PPS-10M power supply is also mounted in this bracket with room for 2 other expansion cards, either PNC-2Z s or PRM-4 s. The Model PSE-2 is a larger enclosure which can support up to 32 IDC s, two power supplies and the full complement of bell and relay modules. If two power supplies are installed, the batteries are to be moved to a Model BB-55 battery cabinet. Zone Expansion The Model PZE-4B is a 4 zone expander for the base PXL. All zones are Style B (Class B) and can be converted to Style D (Class A) with the Model PZC-4D card. These Initiating Device Circuits (IDC s - see NFPA 72) are compatible with all of Cerberus Pyrotronics currently available conventional detectors and devices. Please refer to the chart on the wiring diagram for a complete list. A maximum of 5 PZE-4B cards can be supported in any PXL system. Notification Appliance Circuits The Model PNC-2Z is a 2 circuit expander for the base PXL. All PXL Notification Appliance Circuits (NAC s - see NFPA 72) come standard as Style Z (Class A). They are compatible with the majority of Cerberus Pyrotronics currently available signaling devices. Please refer to the chart on the wiring diagram for a complete list. A maximum of 4 PNC-2Z cards can be supported in any PXL system. Relays The Model PRM-4 has 4 single pole double throw relays for expanding the base PXL output capability. Each Form C relay is rated at 5 amps for resistive loads and can be programmed to follow the status of any number of IDC s. A maximum of eight PRM-4 cards can be supported in any PXL system. Power The Model PPS-10M power supply can be duplicated in the PSE-2 enclosure. A maximum of 2 power supplies can be supported in any PXL system including the primary supply in the base unit. The module includes a 2 amp battery charger and 10 amps for NAC power. One PTX-12 transformer is required with each PPS-10M. Features The PXL answers the needs of today s fire alarm market with both hardware and software based features. Following is a description of some of the many features available in the system. Initiating Device Circuits All PXL IDC s can support 30 conventional smoke detectors. Additionally, the individual smoke detector can support either a remote lamp or a remote relay or audible base. Only one initiating device is guaranteed to alarm per zone. This should be taken into account when using the detector relay base for fan shutdown. Alarm verification is available as a software option. When an IDC is programmed for alarm verification, that IDC can support manual fire alarm stations (or other shorting devices) along with smoke detectors. The detectors will cause a fire alarm only after the verification cycle is complete. The manual stations will create a fire alarm when activated, without delay. The IDC s can also support up to 30 flame detectors, either the S121, S122 or DF-30. All IDC s can be programmed for General Alarm, Supervisory Service or Alarm Verification. Notification Appliance Circuits All NAC s are rated 2 amps and are power limited per UL 864 requirements. All NAC s can be programmed for the following options: Temporal Code, March Time, California Uniform Fire Code, or Non-Silenceable, steady. Temporal Code meets the requirements of NFPA 72 and ANSI S3.41 for emergency evacuation signals. Each IDC can be mapped to specific NAC s as required via program options. Relays Alarm, supervisory and trouble relays on the power supply are not programmable. The relays on the PRM-4 expansion card are fully programmable to follow the activation of any IDC. Activation of a relay by multiple zones utilizes OR logic so that the first of the mapped zones to alarm will activate the relay. All relays have transient protection.

Power Supply Each power supply has a 10 amp NAC power output and a 1 amp auxiliary, power limited output. If used, the 1 amp auxiliary output reduces the available current at the NAC power output. Assembly The PXL system is assembled into the PSE-1 or PSE-2 enclosures with the use of the PMK-1 mounting bracket kits. One bracket is required for mounting modules in the PSE-1 and is shipped in this enclosure. Two PMK-1 mounting brackets are required and included in the PSE-2 (large) enclosure. A model PMK-2 bracket is available for mounting additional relay & NAC cards in the PSE-2. These mounting brackets can be ordered separately to allow for the assembly and test of systems off-site, prior to installation. Software Features The PXL system has numerous software based features as well as options only available through programming. Following is a list of the majority of those features. Please refer to the Installation, Operation and Maintenance Manual part number 315-094131, for specific details on these features. Zone Bypass (IDC) Bell Circuit Bypass (NAC) Relay Bypass Bell Inhibit and Cutoff Timers (NAC) Password Protection Custom Message by Zone (IDC), NAC, and Relay One Person Test Bell Circuit (NAC) and Relay Test History Log - 50 events On-Request Help Messages Ordering Information Model Number Part Number Description PXL 599-694189 Complete PXL system including: Main Board w/ display and 12 initiating zones; 10 amp power supply board w/ 4-2 amp bell CKT s; transformer, battery charger, and system relays; system enclosure and door. PZE-4B 500-894064 4 zone expansion module for PXL PZC-4D 500-894148 4 zone Class A conversion module PNC-2Z 500-894079 2 zone notification appliance circuit module PRM-4 500-894080 4 relay card module - form C, 5 amp relays LED-3 LED-4 500-693062 500-693317 remote serial annunciator. 8 zone white/black PPS-10M 500-494274 auxiliary 10 amp power supply w/ 4-2 amp bell circuits and battery charger PTX-12 500-694133 12 amp 120 transformer PSE-1 500-693690 PXL system small enclosure and door (also houses 1 PPS-10M) PSE-2 500-694252 PXL system large enclosure PMK-1 500-693691 Spare Module Mounting Bracket PMK-2 500-694253 Relay Mounting Bracket BP-61 175-387194 15 AH battery set BTX-I 175-083897 31 AH battery set BTX-2 175-083898 55 AH battery set PXL Operation, Installation and Maintenence Manual is P/N 315-094131 Dimensional Drawings PSE-1 Enclosure PSE-2 Enclosure

Strobes S15-FS S15-F S15-FT S15-ST S15-S S17-FS S17-F S17-S S17-FT S17-ST S75-FS S75-F S75-S S75-FT S75-ST S110-FS S110-F S110-S S110-FT S110-ST EC-F EC-S Chimes TABLE 2 COMPATIBLE NOTIFICATION APPLIANCES Electronic Horns 1-Tone with strobe EH-S15-F EH-S15-S EH-S15-C EH-S17-F EH-S17-S EH-S17-C EH-S75-F EH-S75-S EH-S110-F EH-S110-S Vibrating Bells BT-F BE-F BS-F BF-F BT-LC BE-LC BS-LC BF-LC EC-C CH-F HN-S15-F HN-S15-S HN-S15-C HNH-S15-F HNH-S15-S HNH-S15-C HN-S17-F HN-S17-S HN-S17-C HNH-S17-F Electro-Mech. Horn/Strobes HNH-S17-S HNH-S17-C HN-S75-F HN-S75-S HNH-S75-F HNH-S75-S HN-S110-F HN-S110-S HNH-S110- HNH-S110- Horns/Horn Strobes 3-Tone 8-Tone MC-F MC-S MC-C MC-S15-F MC-S15-S MC-S15-C MC-S17-F MC-S17-S MC-S17-C MC-S75-F MC-S75-S MC-S110-F MC-S110-S MT-F MT-S MT-C MT-S15-F MT-S15-S MT-S15-C MT-S17-F MT-S17-S MT-S17-C MT-S75-F MT-S75-S MT-S110-F MT-S110-S Electronic S.W./Chim EW-S15-F EW-S15-S EW-S15-C EW-S17-F EW-S17-S EW-S17-C EW-S75-F EW-S75-S EW-S110-F EW-S110- EC-S15-F EC-S15-S EC-S15-C EC-S17-F EC-S17-S EC-S17-C EC-S75-F EC-S75-S EC-S110- EC-S110- Electro- Mech. Horns HN-F HN-S HN-C HNH-F HNH-S HNH-C HNH-EP HN-EP Chimes/ Strobes Electronic Horns 1-Tone EH-F EH-S EH-C Tri-Horn TTH Electronic Slow Whoop EW-F EW-S EW-C Detector COMPATIBLE Quantity per Loop Base DETECTORS* Installation Instructions Part No. DI-3/3H 30 DB-3S 315-081943-15 DI-A3/A3H 30 DB-3S 315-081943-15 DI-B3/B3H 30 AD-3RI 315-093234-3 DI-4A 30 DB-4 315-095257-11 DI-6 30 DB-4 315-085257-11 DT-3P-135 ** DB-3S 315-084401-4 PE-3 30 DB-3S AD-3RIL 315-081943-14 315-093234-2 PE-11 30 DB-11 315-094198-1 S121/122 30 315-085258 DF-30 30 DB-3S 315-092604 PCM-1 (IDC) PZE-4B (IDC) Class B PNC-2Z (NAC) PPS-10M (NAC) ELECTRICAL RATINGS Supervisory 8.5mA max 8.5mA max 2.4mA max 2.4mA max PPS-10M (Relays) 30 VDC / 120 Alarm 180mA max 180mA max 2A max 2A max 30 VDC / 120 PPS-10M (Serial Bus) 400mA, 24V 400mA, 24V PRM-4 30 VDC / 120 30 VDC / 120 * When a zone is in alarm, each IDC can operate the following: - One ionization or photoelectric type smoke detector - one relay base, or audible base, or remote alarm lamp * When determining quantity of shorting devices, use sound engineering judgement F1 F2 F3 F4 PXL FUSE REPLACEMENT Fuse Description Value XFORM SEC BATTERY AUX POWER +24 VDC 20.0A, 250V, Normal Blow 20.0A, 250V, Normal Blow 1.50A, 250V, Normal Blow 1.00A, 250V, Normal Blow Notes: 1. All wiring must comply with local and national codes. 2. Make no wiring connections while the System is powered. 3. Relay Contacts are shown de-energized. Suitable for resistive load only. 4. Refer to the PXL Operation, Installation, and Maintenance Manual, P/N 315-094131, for further details. 5. No T-tapping allowed. 6. Connect standby batteries only to terminals BAT+ and BAT-. The batteries may be installed in either the bottom of the cabinet or in a UL listed battery enclosure. 7. In all cases the Cerberus Pyrotronics model number is the compatibility identifier, including the control panel, module(s), and all compatible initiating devices. 8. All power limited wiring requires separation from non-power limiting wiring. Refer to the PSE-1 Installation and Power Limited Wiring Instructions, P/N 315-094154. 9. Combination of NAC power and AUX power can be no greater than 10A. 10. Use up to 31AH lead-acid battery only. Battery charging current is 2A max. 11. Canadian systems require automatic battery disconnect. Refer to Appendix B of the PXL Operation, Installation, and Maintenance Manual, P/N 315-094131, for wiring information. 12. Up to 8 LED-3/-4 modules may be connected to the serial bus (TB-5). For further information, refer to the LED-3/-4 Installation Instructions, P/N 315-093066.

Mechanical Drawings Mounting of PPS-10M, PRM-4 s and PNC-2Z s Mounting of PCM-1 and PZE-4B Cerberus Pyrotronics 8 Ridgedale Avenue Cedar Knolls, NJ 07927 Tel: (201) 267-1300 FAX: (201) 397-7008 2/97 10M CPY-IG Printed in U.S.A. Cerberus Pyrotronics 50 East Pearce Street Richmond Hill, Ontario L4B, 1B7 CN Tel: (905) 764-8384 FAX: (905) 731-9182 February 1997 Supersedes sheet dated 8/