Carbon Dioxide Fire Suppression Systems

Similar documents
TRUSTED PERFORMANCE. Carbon Dioxide Fire Suppression Systems

CO2 COCO GAS FLOODING SYSTEM

FIRE SUPPRESSION SYSTEM

MAXIMUM KNOCKDOWN ABILITY Large Dry Chemical Fire Suppression Systems

Superior by Design The Kidde ADS TM FM-200 System

ANSUL. Twin-Agent Fire Fighting/Securing Systems Specifications. Models 450/50-B, 450/100-B, 900/100-B INDEX SPECIFICATIONS

CO 2 EXTINGUISHING SYSTEMS

CORE Protection Fire System Specification

Fixed Fire Extinguishing Equipment and Systems

GAS EXTINGUISHING SYSTEM INERT GAS. Argotec with carbon dioxide. Safe for certain.

Carbon Dioxide Extinguishing Systems Fighting fire with CO2

SECTION FM-200 FIRE SUPPRESSION SYSTEM

Hospitals and Major Medical Centers

Twin-Agent Fire Fighting/Securing Systems Specifications

Specification/ Data Sheet

SPECIFICATION: CARBON DIOXIDE ENGINEERED FIRE SUPPRESSION SYSTEM

Engineering Specifications

Data/ Specification Sheet

Amerex Clean Agent System with FM200. Potential Applications: System Coverage Overview: Approvals and Standards:

Types of Detection. Fusible Link Detection - Most Common

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH SHP-PRO CONTROL PANEL

A Guide for Meeting NFPA 10 Subsection

TWO TIMES THE FIGHT Twin-Agent Fire Suppression Systems

INDEPENDENT FIRE EXTINGUISHER SALES & SERVICES. Your First Line of Defense Since 1971

Deluge & Preac tion Systems

PRICELESS PROTECTION INERGEN Clean Agent Fire Suppression Systems

SPECIFICATION: DRY CHEMICAL FIRE SUPPRESSION SYSTEM FOR INDUSTRIAL APPLICATIONS MODEL IND

SUPPRESSION SALES I INSTALLATION I SERVICE

DIVISION 21 FIRE SUPPRESSION FIRE SUPRESSION

GAS EXTINGUISHING SYSTEMS INERT GAS. Argotec with argon or nitrogen

SPECIFICATION: ARGONITE Engineered Fire Suppression System

SPECIFICATION: Kidde Engineered Fire Suppression System Designed for use with 3M Novec 1230 Fire Protection

A. NFPA 2001 Standard for Clean Agent Fire Extinguishing Systems 2004 edition.

SECURITY BLANKET Foam Fire Protection Products

Industrial Dry Chemical Fire Suppression System

MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle.

GAS FLOODING SYSTEM FOR CIFF AT BASEMENT

Inert Gas Fire Extinguishing System

READY FOR CHANGE. A Guide for Meeting the NFPA Compliance Standard for Portable Fire Extinguishers

Element C3.4 Fire Fighting Equipment

Fire Safety Compliance

Reliance Fire Protection Systems

CARBON DIOXIDE CO 2 Industrial fire suppression systems

FM-200 In-Cabinet Series

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH CHEETAH Xi 50 CONTROL PANEL

GAS EXTINGUISHING SYSTEMS INERT GAS. Argon Extinguishing Systems. Fire Protection Systems

SPECIFICATION: ECS SERIES CLEAN AGENT FIRE SUPPRESSION SYSTEM

PHIREX AUSTRALIA. FOGEX & MISTEX WATER MIST FIRE PROTECTION

MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle. TM TM

BERMAD Fire Protection

RESOLUTION MSC.339(91) (adopted on 30 November 2012) AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE)

FireFlex 1230 Self-contained system

SECTION TOTAL FLOODING ECARO-25 CLEAN AGENT FIRE EXTINGUISHING SYSTEM

ENGINEERING SPECIFICATIONS FOR FM-200 CLEAN AGENT INDIRECT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS

Safe, Effective, Environment-friendly

TOTALPAC2 Integrated Fire Protection System

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE GENERAL INDUSTRY SAFETY STANDARDS PART 8. PORTABLE FIRE EXTINGUISHERS

Badger Universal Control Head

The Next Generation of Foam Fire Suppression. Automatic CAF Fire hose reel system FEATURES

ANSUL ANSUL AUTOMAN II-C RELEASING DEVICE

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

PORTABLE PERFORMANCE ANSUL Stored Pressure Fire Extinguishers


PRODUCT LISTING DATA SHEET (Active Fire Protection Equipment)

Certificate of Conformity Certificate num. Registration date Version Valid until

AEGIS FEATURES DESCRIPTION. Conventional Fire Alarm-Suppression Control Unit. Effective: March Programmable Relays

Fume Extraction Solutions. We care for your working environment.

SAFETY THE BEST FOR YOUR EQUIPMENT

SPECIFICATION FOR A TOTAL FLOOD ECARO-25 TM CLEAN AGENT FIRE SUPPRESSION SYSTEM FOR USE WITH THE SHP PRO CONTROL PANEL SYSTEM

TECHNICAL MANUAL OPERATOR'S, ORGANIZATIONAL AND DIRECT SUPPORT MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST)

PAFSS Fire Suppression Systems from Jactone. Automatic Fixed Fire Suppression Systems. JACTONE.COM/PAFSS +44 (0)

WATERFRONT FACILITY COMPLIANCE BOOKLET

WATER MIST CONVENTION AND EXHIBITION

TECHNICAL MANUAL OPERATOR'S, ORGANIZATIONAL AND DIRECT SUPPORT MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST)

TotalPac X Firecycle III Preaction Double interlock system

FireFlex DUAL Double Interlock, Self-contained system

CO 2. fire extinguishing systems

ANSUL I-101 INDUSTRIAL FIRE SUPPRESSION SYSTEM TECHNICAL MANUAL VEHICLE PAINT SPRAY BOOTH PROTECTION MANUAL

SPECIFICATION FIKE CLEAN AGENT FIRE SUPPRESSION SYSTEM WITH IMPUSLE VALVE, Fike FK AGENT & SHP PRO CONTROL PANEL

UFGS (August 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS

The leader in gas dehydration & filtration

CLEAN AGENTS Updates to the NFPA 2001 Standard on Clean Agent Fire Extinguishing Systems 2015 Edition

TotalPac 3 Firecyle III Deluge Remote controlled system

FIREDETEC PRODUCT TECHNOLOGY: DIRECT & INDIRECT

Amerex Fire Suppression Systems. Because Operators and the Environment are NOT Disposable Quality is Behind the Diamond.

TRIMAX ASIA ENGINEERING & CONSTRUCTION (PG U )

Release Control Fire Alarm Systems

Kidde Nitrogen Inert Gas Clean Agent Fire Suppression System

FUNCTIONAL SAFETY IN FIRE PROTECTION SYSTEM E-BOOK

Notice on the implementation of the amendments to the FSS Code in resolution MSC.339(91)

SPECIFICATION FIKE CLEAN AGENT FIRE SUPPRESSION SYSTEM WITH IMPULSE VALVE, FK AGENT & CHEETAH Xi 50 CONTROL PANEL

PURGER INSTALLATION AND OPERATION BULLETIN PUR-SB17-02 SERVICE BULLETIN

EXTINGUISHING SYSTEM DETECTION AND CONTROL

TotalPac X Single interlock SUREFIRE system

CleanSpray System Operation

Detection, and Suppression Systems

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

SPECIFICATION FOR A TOTAL FLOOD ECARO-25 TM CLEAN AGENT FIRE SUPPRESSION SYSTEM FOR USE WITH THE CHEETAH Xi 50 CONTROL PANEL SYSTEM

Advanced Integrated Fire Protection Systems TOTALPAC 2. Owner's Operation and Maintenance Manual FIRECYCLE III. September 2009 FM-086G-0-5E

Fire Control Panels. Automatic Extinguishing, Deluge and Preaction Sprinkler System Releasing Control

Transcription:

Carbon Dioxide Fire Suppression Systems

The original "clean agent," carbon dioxide suppresses fire without leaving behind water, foam or dry chemical to damage sensitive equipment. And because there is no agent to clean up, you re back in business faster. Carbon dioxide systems are still the best fire protection solution for many applications. They provide automatic or manual protection for Class A, B or C fires. Although carbon dioxide fire protection is not a new concept, its versatility and unique benefits have kept it in high demand. Carbon dioxide can be applied by totally flooding an enclosed area or locally discharging the agent directly on the surface of the burning material. Today s systems are equipped with sophisticated detectors, intelligent control panels and computer designed distribution networks. Ansul High Pressure Carbon Dioxide Systems are recommended for hazards like semiconductor wet benches, control rooms and paint lines. Whatever the application, from cylinder to nozzle, each system is custom-designed for your specific fire hazard. High pressure systems use individual storage cylinders up to 100 lb. (45 kg) capacity each - that can be manifolded together for rapid simultaneous discharge. Cylinder valves can be opened automatically or manually, locally or remotely using electric, pneumatic or mechanical valve actuators. Ansul High Pressure Carbon Dioxide Systems are listed by Underwriters Laboratories (UL) and have been approved by Factory Mutual Research Corporation (FMRC) and the U.S. Coast Guard. Odorizer Emits Wintergreen Scent to Precede Discharge Cylinder Valves Operate Automatically via Manifold Backpressure Modular Mounting Bracket Design

Supervisory Pressure Switch Manifolding Allows Single or Multiple Hazard Protection from One Storage Location (Selector Valves Available for Multiple Hazards) Resettable / Stackable Electric Valve Actuator Various Total Flood and Local Application Nozzles Available to Meet Design Requirements CO2 Cylinders: 35, 50, 75 and 100 lb. (16,23,34 and 45 kg) Capacities Detection and Control System Available (Not Shown). Automates system and provides more flexibility to meet design requirements necessary for the hazard.

ANSUL PREFERRED Bulk Low Pressure Carbon Dioxide Systems are for fire hazards requiring large amounts of extinguishing agent in a limited amount of space. A single bulk tank can store from 3/4 to 60 tons (680 to 54,430 kg) of carbon dioxide, which is maintained in a stand-by fire ready state allowing the system to provide effective distribution of agent on demand. AUTOPULSE Control Systems provide detection, alarm, auxiliary control and automatic release of a carbon dioxide system. Input from sensitive heat or smoke detectors is designed to catch a fire while it s still small. Depending on the nature of your fire hazard, Ansul provides various options to fit your situation. From the agent container to the discharge nozzle, every Ansul carbon dioxide system is computer-designed specifically for your hazard. This provides the most economical system arrangement without sacrificing performance. The liquid CO2 is stored in an ASME coded pressure vessel equipped with its own refrigeration system. The pressure within the vessel is maintained near 300 psi (20.7 bar) by maintaining the internal temperature at approximately 0 F (-17 C). Valve control is electro-pneumatic or manual. Each master and selector valve assembly consists of either a ball or butterfly valve, a spring return pneumatic valve operator and a three-way electrically operated solenoid valve. A listed and approved releasing control panel is used to provide automatic detection and control. ANSUL PREFERRED Bulk Low Pressure Carbon Dioxide Systems have been approved by Factory Mutual Research Corporation (FMRC). (ANSUL Bulk Low Pressure Carbon Dioxide Systems are listed by Underwriters Laboratories (UL) and have been aproved by the U.S. Coast Guard). Hose Reel Station Available with 50, 100 or 15 (15, 30 or 46 m) of Hose

Available Nozzles Include SR, Orifice, D and Radial (Shown) Supervisory Pressure Switch Manual / Automatic Selector Valve for Multiple Hazard Protection 0 ft. Bulk Storage Tank: 3/4 to 60 Ton (680 to 54,430 kg) Capacity Manifold - Coil Refrigeration Unit is Energy Efficient Detection and Control System Available (Not Shown). Automates system and provides more flexibility to meet design requirements necessary for the hazard.

Typical CO2 Applications Commercial Fryers Dip Tanks Drying Towers Electrical Generators Electric Generating Equipment Electrical Panels Marine Applications (cargo holds, paint lockers, etc.) Spray Booths Waste Disposal Equipment Gas Turbines Coal Silos Hazardous Material Storage Quench Tanks Semiconductor Wet Benches Computer Room Sub-Floors Control Rooms Coating Operations Paint lines Battery Storage Rooms Wave Solder Machines Machine Operations Hose Reel Stations Transformer Vaults Dust Collectors Printing Presses Inerting Systems With capacities of 800, 1000 and 1,500 lb. (363, 454 and 680 kg), mini-bulk tanks bridge the gap between high pressure cylinders and low pressure bulk tanks. The ANSUL PREFERRED Mini-Bulk Low Pressure Carbon Dioxide System was developed to provide an alternative to manifolding high pressure cylinders. The tanks are configured vertically to save valuable floor space and their design is accommodating: mini-bulk tanks can provide protection for total flood, local application hazards, hose reels, or custom designs like inerting or spurt systems. Each mini-bulk tank is equipped with a low cost, high efficiency, air cooled vapor compression unit. The refrigerant media R134a is environmentally safe and is very efficient in this application. All system components are interchangeable between the mini-bulk system and the larger bulk storage tank system. The system control valves operate on 24 VDC, which is compatible with most approved releasing panels. Mini-bulk tanks can be filled in place or can be removed for remote filling. When filling in place from a standard delivery truck, fill connections can be extended to an area outside the building. The storage tanks are provided with skid mounted bases for easy handling. ANSUL PREFERRED Mini-Bulk Low Pressure Carbon Dioxide Systems have been approved by Factory Mutual Research Corporation (FMRC).

Available Nozzles Include SR, Orifice, D and Radial (Shown) Detection and Control System Available (Not Shown). Automates system and provides more flexibility to meet design requirements necessary for the hazard. Manual / Automatic Selector Valve for Multiple Hazard Protection Low Cost, High Efficiency Cooling System Operates at 120 VAC When system is actuated, Automatic Timer Cabinet delays discharge, alerts personnel of pending emission and manages valve operation Exclusive Mini-Bulk Tank Design: 800, 1000, and 1500 lb. (363, 454, and 680 kg) Capacities