Spray Rinse & Steam Handling

Similar documents
Yarway Narvik Steam Desuperheater Series 4300 TempLow

280 SERIES STEAM CONVERTING VALVE SIZING AND SELECTION. 1. Introduction Design Properties Sizing and Selection Criteria...

NEOTeCHA Reactor Sampling Type PV

Steam Traps and Steam Specialties

Steam and Condensate Technology. Solutions which are brilliant in their simplicity. combined with a first-class design & consultancy service.

HOW TO SELECT AN INDIRECT THERMAL TECHNOLOGY FOR INDUSTRIAL MATERIALS PROCESSING

Guardian II Metal Bellows Seal. Valtek Guardian II Metal Bellows Seal Control Valves

De Dietrich Valves CONCENTRATED INNOVATIONS

High pressure cleaning heads cleanliness all around

KRAL Screw Pumps. L Series.

The Condensate Water Systems

Boiler Basics. Design and operation

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

YARWAY NON-REPAIRABLE DRIP AND TRACER STEAM TRAPS SERIES PB, 29, 129Y AND 29S

APPLICATION REPORT Isomerisation This diagram is intended to be a representation and should not be viewed as an actual process flow diagram.

Economical and simplified solutions that offer quality and optimum steam trap service.

STAINLESS STEEL TRAP VALVE STATION

Top performance when the going gets tough

NOVADOS. Metering Pumps

INDUSTRIAL CONDENSATE POLISHERS. LWTCP Series

CENTRIFUGAL PUMPS. STATE the purposes of the following centrifugal pump components:

tech-info Continuous centrifugals of the K3000 series Fields of application: The BMA continuous centrifugals of the

CONDAIR ESCO. Live steam humidifier with 100% steam tight rotary valve. Humidification and Evaporative Cooling

Steam-Atomising Desuperheater

Ball Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass

Oxiperm C 164 Fully automatic chlorine dioxide processing plant C, -6000C, -7500C, C. Service manual. Oxiperm 164C 4-10 kg Service en

EasiHeat Mechanical Installation and Commissioning Instructions

Komline-Sanderson Paddle Dryer. Drying technology for biosolids, sludges and by-products

Waste Heat Recovery Using the Example of Slag Fuming

IRRIGATION EQUIPMENT LTD. The Perfect Solution for Water Filtration and Irrigation Problems


Valtek Guardian II Metal Bellows Seal Valtek Guardian II

PRODUCTS. Expansion Joints Fire Fighting. Flexible Metal Hoses. Equipments. Insulation Solutions. Steam. Valves. Level Control.

9707 Key West Avenue, Suite 100 Rockville, MD Phone: Fax:

PASSION THAT DRIVES PERFORMANCES. WASHINGSOLUTIONS

LÖDIGE ALWAYS THE RIGHT MIX

Jet Compressors. Circulate Steam Boost Low-Pressure Steam Compress and Mix Gases in Desired Proportion

Operating Instructions

Borosilicate 3.3 Glass Pilot plants / Equipment

Vacuum and Compressor Systems for the Chemical Process Industry

GESTRA Valves for Pure and Sterile Steam Systems. Intelligent solutions for sensitive processes

Honeywell Control Valve. HFP Asia Pacific

PLASMAC Ltd. Units 11&12 Aylesbury Business Centre Chamberlain Road Aylesbury Bucks. HP19 8DY. UK

Our Know-How. Your Peace of Mind. Steam Solutions

Blowdown Separator & Aftercoolers Installation, Operation, & Maintenance

BAGI - MIXER. Magnetically Driven Bottom Mounted Mixers. Sealless ZERO LEAKAGE Design. CIP / SIP Capable. Non Contaminating Mixing

Technology of cleanliness. Hygiene technology by schülke.

Fig.: macroscopic kinetic energy is an organized form of energy and is much more useful

BORSIG WASTE HEAT BOILERS FOR NITRIC ACID, CAPROLACTAM AND FORMALDEHYDE PLANTS PROCESS HEAT EXCHANGER. A Member of KNM Group Berhad

Vacuum filters. Established for industrial dewatering

Chemistry diaphragm pumps

Wallace & Tiernan Gas Feed Systems V2000 Chlorinator

Technical Data CONDENSATE COMMANDER PUMP SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 9902D

DUOMIX. WIWA High-Performance Dual Component Airless Paint Spraying Equipment

SCHNEIDER-KESSEL BERLIN

TECHNICAL. Series 18. Pump Packages

Steam Generator (Boiler) & Steam Turbine. Steam Generator (Boiler) ME 268. Model Lab

Temperature controller for steam (PN 25) AVT / VGS - external thread

Hot water super class HDS 12/18 4S *AU

INDUSTRIAL GRADE WATER SOFTENERS LWT INDUSTRIAL SERIES

DUOMIX 140 /DUOMIX 230

Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25)

OPTIMISE VACUUM TO IMPROVE PLANT PERFORMNCE

HydroPower Washing. Setting the Standard in thorough Cleaning of Plastics: The Friction and Tornado Washers

High-Pressure Atomizing System

Industrial Processing Solutions

Reactor-Boiler and Auxiliaries - Course 433 BOILER STEAM AND WATER SYSTEMS

DIAPHRAGM VACUUM PUMPS

HMA GROUP AUSTRALIA - NEW ZEALAND - INDONESIA - SOUTH AFRICA SINCE 1966

Vacuum Booster for Distillation Process

SPECIALIZED EQUIPMENT

Operating manual for Steam Injectors / Mixing Nozzles

Products Solutions Services. Energy Solutions. Food & Beverage industry. Slide 2

PRODUCT MANUAL FIRE EXTINGUISHER. Carbon Dioxide 6.5, 9 & 22.5 Kg Capacity Trolley Mounted (45 kg also as a non standard)

Vacuum System Troubleshooting Author: Keith Webb, P.E. Application Engineering Manager

Machine needle shut-off nozzle Type SHP (high performance) spring operated

BALANCED FLOW METER PLATE APPLICATIONS

Tough as They Come. Ceramat. Retractable fittings for extreme conditions. With ceramic sealing to the process.

DIAPHRAGM VACUUM PUMPS FOR AUTOCLAVES

Industrial Processing Solutions

Thin Film. Optimizing Temperature Control 2. Preventing Excessive Vacuum 3. Minimizing Air Drawback 4

TMCI Padovan Evaporators

Instruction Manual, Toftejorg Rotary Spray Heads Toftejorg MultiMidget, Toftejorg MultiMagnum

Pneumatic Vacuum Conveyors for the Highest Standards Transportation of bulk materials in the pharmaceutical and chemical industries

THE HYTORC WASHER SYSTEM

Open System Condensate receiver tank of cylindrical. design type SDR A with highpressure

ECONOMICAL AND ENVIRONMENTALLY FRIENDLY - SENSIBLE PAINTING AND COATING TECHNOLOGY. Reduction in Costs for Coating Materials

more powerful than hand-held alternatives so they do a better job of cleaning and removing deposits.

Off Design Operation of Hybrid Noncondensable Gas Removal Systems for Flash Steam Cycle Geothermal Power Plants

Submerged Pumps and Expanders with Magnetic Coupling for Hazardous Applications

Leica EM CPD030 Order List Version 10/2008

Understanding Process Vacuum for Process Improvement

Northvale Korting Global Contacts

Pulse Jet Baghouse ASTEC PULSE JET BAGHOUSE. for Asphalt Facilities

VPC Vertical Turbine, Double Case Pump

The smart handling of liquid chemicals: quickly connected safely dispensed.

High-efficiency oil-free Compressor

MANAGING ENERGY EFFICIENTLY FOOD, DAIRY AND BEVERAGE INDUSTRIES

CBU144. Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717. Product specification sheet

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

Transcription:

Spray Rinse & Steam Handling

Spray Rinse Valve 27 SR The Fetterolf Spray rinse valve Type 27 SR was developed to wash residue from large tank or reactor walls without having to open or enter a vessel. This feature has two key benefits: safety of personnel for applications with toxic fluids and to reduce cleaning time in batch processes. Spray rinse valves are frequently found in the Plastics & Polymer (especially PVC), Fine Chemicals and Pharmaceutical industries. It ensures a unique two stage efficient spray pattern, while maintaining a simple, rugged design, utilizing the famous SchuF metal-to-metal shut-off, first developed in the 1920's. Application Spray rinse valves can be used to clean vessels after each batch operation. Water, steam, solvents and anti-sticking agents can be injected and are sprayed in a distinct and efficient pattern into the vessel. This leads to longer uninterrupted reactor production cycles and the most cost efficient use of cleaning agents. They are also used in vessel rinsing applications with toxic media in order to ensure personnel safety. Operation: In operation, the spray tube assembly is moved out of the valve body to initiate the spray and retracts back into the valve body after the washing cycle. In the closed position the valve disc is flush with the end of the valve body and the spray head is tightly sealed off from the process and remains clog free. Spray Rinse Valve 27SR with slots and electric actuator As the valve opens, water is initially concentrated at the vessel bottom, gushing between the spray head and the seat. Only after the residue at the bottom of the reactor has been dislodged are the spray slots allowed to emerge. These ensure a 360 spray pattern as it fans out to spray sideways and, increasingly, backwards. To ensure full pressure and concentrated flow the straight down direction is now closed off. At the end of the stroke the distribution of spray apertures ensures a 360 spray pattern, directed principally at the top of the vessel as required by, for example, the PVC industry. As the valve closes a continuing flow of water prevents clogging until the positive metal-to-metal shut-off guarantees leak-free, bubble-tight shutoff.

Spray Rinse Valve 27 SR The device efficiently performs the dual functions of: Shut-off and control of the spray water Direction of the spray in a varying pattern to attain complete wash-down of the residue. The valve can also be used to distribute anti-sticking agent. Key Features: Standard sizes 3/4 up to 2 (DN 50) and ASME 900# positive metal-to-metal shut-off Customised spray pattern, pressure & volume Zero leakage to atmosphere and process dual Ram seal design Exchangeable seat and spray head No clogging guaranteed, due to pre-designed leakage path Rotating or linear spray head Electric or pneumatic actuation Optional position switches Easily retrofitted to existing reactors Spray Rinse Valve 27SR with nozzles and pneumatic actuator Benefits Increased batch process productivity and Reduced maintenance, e.g. eliminates the need for vessel opening and closing between batches Protection against toxic emissions Optimised water & solvent consumption Directing the use of water, steam, solvents and anti-sticking agents

Steam Injection Valves 27SE Steam injection valves are primarily used in the chemical, pharmaceutical and petrochemical industries. They are used to inject steam or any gas into a reactor or vessel. Application There are two common applications: 1. Direct and quick pre-heating of media and/or vessels 2. Steam stripping and sanitisation to remove monomers or impurities in polymerisation processes. The choice of a piston or disc injection valve design is process and media driven: A solid piston design is suitable for full bore, high flow rate applications with vibrations. Disc style injection valves are more suitable where space is limited, the required flow rate is low or where low or zero emissions to atmosphere are important. Key Features: Piston or disc valve design Metal to metal sealing Replaceable seat and injection head Customised arrangement of holes for any required gas or vapor injection Non clogging Operation The valve is typically installed at the bottom of a vessel. Steam is injected into the inlet, flows through the hollow injection stem and exits through up to 2000 dispersion holes. Constant steam pressure ensures that there is no back-flow and keeps the dispersion holes free of sediment build up. The valve operates according to a linear step control curve characteristic. This allows a predetermined number of hole rings to be expose das required by the process. Most batch polymer processes begin as endothermic reactions and require heat to get started. This can be accomplished by heating the vessel either through a jacket or by inner colis. An alternative method gaining more and more acceptance is that of direct steam injection. Here steam is injected at the bottom of the reactor using SchuF s patented steam injection valve, the type 27SE.

Steam Injection Valves 27SE A piston rising valve, it features a variable number of holes arranged in a stepped linear manner along the piston. A positioner allows you to control the flow of steam into the reactor. The different distribution angles of the injection holes ensure an even steam distribution throughout reactor, thus ensuring maximum thermal efficiency with minimal dilution effect. This valve is also used for the stripping or desoderizing of the batch at the end of reaction. Here steam is injected and allowed to bubble up through the batch removing or stripping away the free monomers, as well as residues and impurities. Benefits Time saving vessel pre-heating Evenly distributed steam pattern Step-linear flow rate control Optimised steam usage Avoids steam hammer effects

Desuperheater Valves 27DS Desuperheater (Temperature Control) Valve While superheated steam is often available as an energy source, the use of saturated steam is actually more desirable and efficient. This steam conditioning valve's function is to lower and maintain the steam's temperature down to saturation by adding varying amounts of water. Also useable for any other application that involves adding a cold liquid to a hot gas, the valve was developed from the SchuF steam injection valve. Spray nozzles are designed to atomise the liquid to optimise the heat transfer. The quantity of injected water is varied by varying the amount of injection nozzles through which the water passes by positioning the spindle. This eliminates the need for an additional in line control and maintains a maximum pressure drop through each individual nozzle, optimising the atomisation and minimizing droplet size. Features: Counterflow nozzles designed to ensure atomisation with a delta P as low as one bar. Valve C v from 0,05 to 15 with 3,4,6,8,9 or 12 nozzles in the spray head. Nozzles are staggered, so that almost perfectly linear control is achieved. Piston sealing rings titanium nitrided for better sealing and smoother running. Graphite packing and nitrided spindle ensures perfect, leakfree sealing to the outside while maintaining the low packing friction important for good control. Special materials available for non water/steam applications. Available with pneumatic diaphragm or piston actuator, air motor, hydraulic or electric actuators. Intelligent or standard positioners as per customer preference. Also available as a steam assisted desuperheater for applications with lower cooling water pressures and higher steam speeds (5 bar > Pw >= 3bar, vs >= 15m/s). Sizing Mw (ho - hw) = Ms (hi - ho) where Ms is the mass flowrate of the steam (kg/h) Mw is the mass flowrate of the injected water (kg/h) hi is the enthalpy of the inlet steam ho is the enthalpy of the outlet steam hw is the enthalpy of the injected water The maximum water to steam ratio (100*Mw/Ms %) should not exceed 10% at low pressures, 20% at medium pressures. The temperature sensor should be at least 12m from the desuperheater, the minimum straight pipe length at least 4m.

Steam Control & Conditioning Valves 27DU/R These valves reduce and control the pressure and temperature of steam. Steam is generally generated at high temperatures and pressures to ensure high turbine efficiencies. Other steam users in steam heating, heat exchangers use low pressure and temperature steam. A steam conditioning valve produces this steam. A steam control valve is often used as a boiler feed control valve, to control the flow of steam into the boiler. Features: 27DU Steam conditioning valve In contrast to the control valve, for steam conditioning cooling water is injected through the spindle in proportion to the stroke and therefore the steam flow through the valve. A two stage pressure drop is standard but up to two more stages can be added in the seat area and up to three fixed silencer plates can be fixed in the widened outlet. This multi stage reduction splits the pressure drip across each stage and reduces noise. Wear, erosion and corrosion are minimised by the choice of special cage and seat materials, as well stelliting or Colmonoy treating. The valve disc is pressure relieved so the actuators can be relatively small. Graphite packing and metallic, specially hardened sealing surfaces. Special materials available for non water/steam applications. Available with standard PM actuator but also with piston actuator, air motor or electric actuators. Intelligent or standard positioners as per customer preference. 27DR Steam Control Valve controls the flow through the valve und thus the pressure into,say, the boiler. No cooling function. With 2-4 stage cage and up to 3 fixed noise reducers. 27DU Steam Conditioning Valve Combines a control and cooling function. The further the valve opens the greater the product through put and the more cooling water is added.

Worldwide www.schuf.com www.schuf.de Your Sales Channel: USA Fetterolf Corporation phone: +1 610 584-1500 info@fetterolfvalves.com SchuF (USA) Inc. phone: +1 843 8813345 sales@schuf.us IRELAND SchuF Valve Technology GmbH phone: +353 21 4837000 sales@schuf.ie GERMANY SchuF-Armaturen und Apparatebau GmbH phone: +49 6198 571 100 sales@schuf.com SchuF Benelux B.V. phone +31 25 12 34 448 lmulder@schuf.com SchuF Middle East F.Z.C. phone: 971 56 424 2190 mmulder@schuf.com SchuF South East Asia Pte. Ltd. phone +353 877774860 ecalnan@schuf.ie SchuF Valves China Ltd. phone +85 22 86 50 861 pchoi@schuf.com ITALY La Tecnovalvo S.r.l. phone: +39 023503508 info@latecnovalvo.com UNITED KINGDOM SchuF (UK) Ltd. phone: +44 203 355 2012 sales@schuf.ie INDIA SchuF Speciality Valves India Pvt. Ltd. phone: +91 421 2264600 sales@schuf-india.com Your Local Agent: