Comparison of Energy Efficiencies of Commercial Refrigeration Direct and Indirect Systems

Similar documents
Heat Exchanger Shelves For Better Temperature Control Of Food In Open-Type Display Cases

HSPF Calculation of a System Allowing Switching Between a Single-Stage to a Two-Stage Compression System

Low Global Warming Refrigerants For Commercial Refrigeration Systems

High Efficiency Heat Pump for Domestic Hot Water Generation

Modelling of an Integrated Supermarket Refrigeration and Heating System Using Natural Refrigerants

Low GWP Refrigerants for Air Conditioning Applications

System Using Exhaust Heat from Residential GHPs

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

Analysis of the Sub-Cooling on Refrigerating Systems Using R-410A or R-404A

Effects of Frost Formation on the External Heat Transfer Coefficient of a Counter-Crossflow Display Case Air Coil

Optimization Study of Absorption/Compression Cooling Cycles

Performance Comparison of R32, R410A and R290 Refrigerant in Inverter Heat Pumps Application

Lower GWP Refrigerants Compared to R404A for Economizer Style Compressors

Introduction of Transcritical Refrigeration Cycle Utilizing CO2 as Working Fluid

Higher Efficiency, Lower Sound, and Lower Cost Air Conditioning Compressors: Part 1 Efficiency

Conceptual Design of a Better Heat Pump Compressor for Northern Climates

The Innovative Green Technology for Refrigerators Development of Innovative Linear Compressor

Refrigeration Cycle And Compressor Performance For Various Low GWP Refrigerants

Effects of Flash and Vapor Injection on the Air-to- Air Heat Pump System

Comparison Of Hermetic Scroll And Reciprocating Compressors Operating Under Varying Refrigerant Charge And Load

R32 Compressor for Air conditioning and Refrigeration applications in China

Efficiency of Non-Azeotropic Refrigerant Cycle

High Efficiency R-134a Compressor for Domestic Refrigerator

Experimental Investigation of a New High Temperature Heat Pump Using Water as Refrigerant for Industrial Heat Recovery

Performance Investigation of Refrigerant Vapor- Injection Technique for Residential Heat Pump Systems

Performance Characteristics of Air-Conditioner Under Tropical Ambient Condition

Improving Heating Performance of a MPS Heat Pump System With Consideration of Compressor Heating Effects in Heat Exchanger Design

Drop-in Testing of Next-Generation R134a Alternates in a Commercial Bottle Cooler/Freezer

Control Method Of Circulating Refrigerant Amount For Heat Pump System

Performance of R-22, R-407C and R-410A at Constant Cooling Capacity in a 10

Development Of 2-Cylinder Rotary Compressor Series For Light Commercial Use With R410A

The Design Of A New Generation Of Twin Screw Refrigeration Compressors

Development and Performance Measurements of a Small Compressor for Transcritical CO2 Applications

Purdue e-pubs. Purdue University

Development of Large Refrigerant Compressors

Study of R161 Refrigerant for Residential Airconditioning

Development of an Open Drive Scroll Compressor for Transportation Refrigeration

AHRI Low Global Warming Potential Alternative Refrigerants Evaluation Program (Low-GWP AREP) â Summary of Phase II Testing Results

Experimental Investigation on the Performance of Ground-source Heat Pump with the Refrigerant R410A

Sub-Critical Operation of the CO2 Expander/ Compressor

Energy Savings Potential of Passive Chilled Beam System as a Retrofit Option for Commercial Buildings in Different Climates

Design and Research of the Commercial Digital VRV Multi-Connected Units With Sub-Cooled Ice Storage System

Air-Cooled Heat Exchanger Performance for R410A

Geothermal ORC Systems Using Large Screw Expanders

Experimental Study About An Amount Of Oil Charge On Electric Driven Scroll Compressor For Electric Vehicle

Effect of Modification in Refrigerant Passage of an Automotive Air Conditioning Compressor

Compressor Capacity Control

Performance Evaluation and Design Optimization of Refrigerated Display Cabinets Through Fluid Dynamic Analysis

Experimental Study of Fouling Performance of Air Conditioning System with Microchannel Heat Exchanger

Dynamic Simulation Model of a Vapor Compression Domestic Refrigerator Running With R134a

Development of a Transient Simulation Model of a Freezer Part II: Comparison of Experimental Data with Model

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

Development of a Novel Structure Rotary Compressor for Separate Sensible and Latent Cooling Air-Conditioning System

Some Modeling Improvements for Unitary Air Conditioners and Heat Pumps at Off-Design Conditions

Load Sharing Strategies in Multiple Compressor Refrigeration Systems

An Investigation Into The Influence Of Improved Refrigeration Cycle And Refrigerants On An Energy Efficient Domestic Refrigerator

Design of Divided Condensers for Desiccant Wheel-Assisted Separate Sensible and Latent Cooling AC Systems

Application Considerations of Line-Break, Internal Protectors

Energy Efficiency of Air-to-Air Mini Heat Pump

Heat Transfer of R-22 and Alternatives in a Plate- Type Evaporator

Experimental Study on the Thermal Behavior of a Domestic Refrigeration Compressor during Transient Operation in a Small Capacity Cooling System

Performance Comparisons Of A Unitary Split System Using Microchannel and Fin-Tube Outdoor Coils, Part I: Cooling Tests

A study of high efficiency CO2 refrigerant VRF air conditioning system adopting multi-stage compression cycle

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation

Performance of CO2 Cycles with a Two-Stage Compressor

Performance Evaluation of the Energy Efficiency of Crank-Driven Compressor and Linear Compressor for a Household Refrigerator

Design and Research of the Digital VRV Multi- Connected Units With Three Pipes Type Heat Recovery System

Experimental Investigation on Condensation Performance of Fin-and-Flat-Tube Heat Exchanger

Development of Performance Test Facility of Positive Displacement CO2 Refrigerant Compressor

Analysis of Oil Pumping in the Hermetic Reciprocating Compressor for Household Refrigerators

Experimental Investigation of Closed Loop Oscillating Heat Pipe as the Condenser for Vapor Compression Refrigeration

Experimental Study on Fractionation of R-407C and Recharge Operations

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

The Development of the Energy-Saving Technology by the Composition Control of R407C

A Performance-Enhancing Additive for Vapor- Compression Heat Pumps: Additional Test Results

Visualization of Evaporatively Cooled Heat Exchanger Wetted Fin Area

Selection of a refrigeration oil for the R32 refrigerant and evaluation of the compressor reliability

DEMONSTRATION OF A MICROCHANNEL HEAT EXCHANGER FOR OPERATION IN A REVERSIBLE HEAT PUMP SYSTEM

The Development Of High Efficiency Air Conditioner With Two Compressors Of Different Capacities

Compressor Capacity Control: A New Direction

The Effect of the Ventilation and the Control Mode on the Performance of a VRV System in Cooling and Heating Modes

Performance Evaluation of a Plug-In Refrigeration System Running Under the Simultaneous Control of Compressor Speed and Expansion Valve Opening

Performance Evaluation of an Economised Indirect Multi-Temperature Transport Refrigeration System

Purdue e-pubs. Purdue University. T. Hamada Mitsubishi Heavy Industries Ltd. N. Nishiura Mitsubishi Heavy Industries Ltd.

DEMONSTRATION OF ADVANCED INTEGRATED HVAC&R SYSTEMS IN A LOBLAWS SUPERMARKET IN CANADA

Application of two hybrid control methods of expansion valves and vapor injected compression to heat pumps

Performance Characteristics and Optimization of a Dual-Loop Cycle for a Domestic Refrigerator- Freezer

Why Secondary-Coolant Systems for Supermarket Refrigeration?

Dynamic Simulation of Liquid Chillers

Comparison Ammonia / Secondary Refrigerant System against Direct Evaporation of HCFCs /HFCs

Development of HFC-134a Compressor for Domestic Refrigerator

Comparison of Thermophysical Properties of HFC 125, 32 and 143a

Investigation, Analysis and Solution of Higher Noise of Heat Pump Water Heater

ENERGY SAVINGS THROUGH LIQUID PRESSURE AMPLIFICATION IN A DAIRY PLANT REFRIGERATION SYSTEM. A. Hadawey, Y. T. Ge, S. A. Tassou

Two-Step Capacity Modulation of a Single Cylinder Compressor

Noise Reduction Technology With Porous Metal for Refrigerant Two-Phase Flow Through the Expansion Valve

The Use Of Attic Space For Cooling and Dehumidification

Exploring the Performance Characteristics of CO2 Cycles in a Breadboard-Type Test Facility

AN EXPERIMENTAL STUDY OF A REFRIGERATING PLANT WHEN REPLACING R22 WITH HFCs REFRIGERANTS

Comparison of the High Side vs

Transcription:

Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 1998 Comparison of Energy Efficiencies of Commercial Refrigeration Direct and Indirect Systems D. Clodic Ecole des Mines de Paris C. Le Pellec Ecole des Mines de Paris I. Darbord Ecole des Mines de Paris Follow this and additional works at: http://docs.lib.purdue.edu/iracc Clodic, D.; Pellec, C. Le; and Darbord, I., "Comparison of Energy Efficiencies of Commercial Refrigeration Direct and Indirect Systems" (1998). International Refrigeration and Air Conditioning Conference. Paper 421. http://docs.lib.purdue.edu/iracc/421 This document has been made available through Purdue e-pubs, a service of the Purdue University Libraries. Please contact epubs@purdue.edu for additional information. Complete proceedings may be acquired in print and on CD-ROM directly from the Ray W. Herrick Laboratories at https://engineering.purdue.edu/ Herrick/Events/orderlit.html

Comparison of Energy Efficiencies of Comm~rcial Refrigeration Direct and Indirect Systems D. Clodic, C. Le Pellec, I. Darbord Ecole des Mines de Paris, Centre d'energetique 60, boulevard Saint-Michel- F 75272 Paris Cedex 06 ABSTRACT Centralized commercial refrigeration is becoming a sector where several technical options are competitive. These options are evaluated based on three major criterions: energy consumption, refrigerant emissions and initial cost. In supermarkets with machinery rooms, the competition is strong between previous centralized direct systems and new systems using heat transfer fluids. To achieve balanced comparisons between energy efficiency of these competitive techniques, measurements of direct expansion systems and of systems using monophase heat transfer fluids have been performed on site. 1. INTRODUCTION Concern over the environmental impact of refrigeration, both from the point of view of refrigerant emissions and of energy consumption, has renewed interest in alternative refrigeration systems [1]. Two options are evaluated for centralized commercial refrigeration: previous direct systems and new indirect systems using heat transfer fluids [2, 3]. One of the main reason to promote this option is due to the dramatic limitation of the initial charge of refrigerant, consequently the quantities of fluid released to the atmosphere are lower. These two alternatives lead to different energy efficiencies compared by two methods. First, energy consumptions of both systems are calculated based on real efficiencies of pumps and compressors which are installed in different supermarkets. Second, measurements are performed in two cold rooms inside supermarket one with a usual direct expansion system, the other with a secondary loop system. 2. CONSUMPTION CALCULATIONS FOR THE TWO OPTIONS A large French supermarket (sales area> 10,000 m 2 ) has been chosen as a reference for this study. Table 1 indicates power of compressor racks for the temperature range. Medium temperature cooling capacity represents around 90% of the whole cooling capacity. Usually, on the French market, it is closer to 75%. Centralized direct expansion system The cooling capacity is spread out over 12 compressor racks to limit consequences of major failure of the refrigerating system and to adapt the evaporating temperature to the required temperatures in display cases and cold rooms. The energy consumption is then improved. All the racks of compressors share one single large air condenser. Each rack is composed of 3 or 4 semi-hermetic reciprocating compressors. The refrigerant is R404A. The calculations of the pressure drops and temperature variations take into account the real tube lengths and diameters. For the direct expansion system the pressure drops on the suction line vary from 1.5 to 2.5 C. 265

Table 1 ~ Compressor and Cooling Capacity Distribution. Designation Number of Cooling capacity Compressor power compressor racks (k W)c Medium Temperature -l5 C < T <- 8 C Display cases 3 504,5 182,3 Cold rooms 5 307,7 86 Total medium temperature 8 812,2 268,3 (kw).............. Low Temperature < -38 C.. "!?.~.~P..!~x.. ~~.~.~~...?....?... ~...?..?..:.1.... Ooo 0000000000o'll00i1000000000M00000000 0000000000000 0000000 00 000000 000000on oi0000000000000000i000000000000000 0000U00000 00000000000000 0o000000000 000U0000000000UI00000000000000000.0U000000000'II000000 Cold rooms 2 26,7 15,7 Total low temperature 4 97,8 73,2 Global cooling capacity 12 n M # n n tt n IUt onoiilt ott ltll 910 341,5 Secondary loop system Data have been gathered from the contractors who installed indirect systems for medium and low temperature loop. Heat transfer fluids are respectively MPG (monopropylene-glycol) for the medium temperature loop and Tyfoxit 1.2 for the low temperature loop. Both fluids represent a good compromise between cost and energy performances. The low temperature loop is a classical two-tubes circuit. A new concept called "Single tube" is taken as a reference for the medium temperature secondary loop. The heat transfer fluid circulates in a single big tube made of monopropylene; each of the display cases or cold rooms is fed by a small pump which provides the coil with a given flow of cold fluid that is released at an increased temperature in the "single tube". The circulation of the heat exchange fluid is realized by a primary pump on the main loop and small pumps for each coil. Energy consumptions of pump and compressor are evaluated from real characteristics of available components. Secondary pumps available at acceptable costs show a very poor efficiency as it can be noticed in figure 1.1. Pressure losses have been calculated for MPG and Tyfoxit in order to calculate the pumping power. Refrigerant for the primary refrigerating circuit is also R404A. 1.0 0.9 0.8 0.7 0.6 0.5 --0.4 0.3 0.25 0.20 0.15 0.10 0.05 0.00 +--------...--...o...t---... ---._ 0 2 4 Flow rote mj/b... "-+----1 Figure 1.1: Efficiency of Secondary Pumps. 0.2 0.1 0.0 0 20 40 60 so 100 120 140 160 Flow rate mj/h Figure 1.2: Efficiency of Primary Pump 266

Results of the comparison The temperature of the air coil inside display cases are set in order to maintain the same temperature of the goods. It is claimed that the average temperature (calculated with the in/out temperatures of the coil) of the heat transfer fluid is 1 oc above the usual evaporating temperature of the refrigerant. Operating parameters and the results of comparison between the direct expansion system and the system using heat transfer fluid are presented table 2. ompanson o t e wo 1 erent systems. T a bl e 2 - C f h T D"ffi s Designation Direct e~ansion system Indirect system Medium Low Medium Low temperature temperature temperature temperature Cooling capacity 812.1 kw 97.8 kw 1013.9 kw 114.1 kw Tevaporating -10 C -35 C -l6 C -42 C (from 0 to -l2 C) Tcondensing +40 C +40 C +40 C +S C Compressor capacity 268.3 kw 73.2 kw 376.6 kw 39.8 kw Pump capacity 33.73 kw 7.29 kw Operation 18 hi 24 h 18 hi 24 h 18 hi 24 h 18 hi 24 h time/day Annual 1766.7 MWh consumption 480.9 MWh 2697 MWh 309.8 MWh Charge of fluid 173S kg 765 kg The efficiency of low temperature racks is much higher for the secondary loop system due to the fact that the refrigerant is condensed at -S C using heat exchange with the medium temperature heat transfer fluid. But this heat which is removed by the medium temperature loop implies a higher power for the medium temperature racks. The global consumption of this system compared to the previous direct system increases by more than 33%. Two main characteristics can explain this over consumption: the evaporating temperature for the heat transfer fluid alternative is lower by at least 4 C than the one of the direct expansion system; the capacity needed for the circulation of the heat transfer fluid is significant and represents around 12% of the added electric power absorbed. The efficiency of the small pumps used to feed each display case is particularly low, less than 20 % as shown in figure 1.1. However, even if the efficiency of these pumps was increased, the over consumption of the system working with heat transfer fluid would still represent 10 % of the compression power. The real gain of the indirect option is a reduction of the refrigerant charge by more than 55%. 3. MEASURES PERFORMED IN SUPERMARKETS Temperature, pressure and energy consumption were registered over three weeks in two large supermarkets (S = 10,000 m 2 ) in December 1997. Both of the stores are located in North of France, so conditions of use of cold rooms and weather are identical. Measures have been registered at various points of the cooling circuits: coils and refrigerating systems. One refrigerating system (IS) is indirect system working with heat transfer fluid, the other system (DE) is a direct expansion system. 267

It has been checked that comparison is based on appropriate conditions, in particular that ratio of heat exchange surfaces compared to the room volume do not exceed 5% (see Table 3). Heat exchange coefficients are higher for coils with heat transfer fluid but air speeds are 2/3 lower. oe 1c1en an ea xc ange u ace 0 oom Tabl e 3 H eat E xc h an_g_e C ffi" t dh te h S rfi I C ld R Vl Cold room Heat exchange surface per Heat exchange Cold room volume volume unit coefficient A (m3) (m2/m3) (W/m 2.K) oume R" Indirect system 1354 0.42 18.8 Direct system 888 0.446 11.2 Registered parameters are: outside temperature, blowing and intake temperatures of air coils, in/out temperatures of the heat transfer fluid or refrigerant, in/out temperatures of heat transfer fluid of the primary heat exchanger in the machinery room, intake pressure and temperature of compressors. Fluids are R22 and MPG as heat transfer fluid. Figures 2.1 and 2.2 are synthetic presentations of temperatures permitting to compare operation between the indirect system and the direct expansion system. Outdoor air temperatures are identical Major conclusions are indicated herebelow. Difference between blowing and intake temperatures is significant: 0.8 K for the direct expansion system and 4.6 K for the indirect system. Indeed, air flow shall be much lower so that air is cooled with a 4 K temperature glide at the heat transfer fluid side. In this study, saturating temperatures observed are ~ 10.9 C for the DE system and ~ 15,6 C for the ID system, that is a compression ratio increase of 20% for the same condensing temperature. At this time of the year, the condensing temperature is set at 30 C. Differences between saturating temperatures Temperatures COC) at10. tor--~~~==========~--~~ 5-10 -15. 9-10,9 ------- -20~----------------------------~ imply an increase of the energy Figure 2.1: Key Temperatures of the Direct Expansion S stem consumption of 15% for the indirect system not taking into account power of pumps. The mean temperature of the cold room is higher than 3. 7 C for the indirect system compare to the direct expansion system. In one case opposed to the other one, the operating temperature is kept. It can be deduced that either the refrigerant capacity of the indirect system is not high enough or the temperature level is not appropriate. Two options exist: either increase the heat exchange surface or decrease the heat transfer fluid temperature. If temperature decreases while maintaining the same temperature differences, the saturated temperature at the compressor intake should be in the range of ~l9 C. 10._Text( 0 C) ---Tdiary 5 room ( 0 C) 0 ---~ ' mean low :,.-T air coil -5 ' ~THTFcoil -10 -+-Tfluid -15 primary loop -20._.Tevap refrigerant Figure 2.2: Key Temperatures of the Indirect System 268

Defrosting water were recovered and weighted. On the referenced period, frost weight is higher in the cold room with direct expansion system (2.9 g/h.m 3 ) than with the indirect system ( 1.8 g/h.m 3 ). This is due mainly to the average room temperature: the higher the room temperature, the higher the moisture level. Defrosting lasts longer and temperature increases are more significant with the indirect system compared to the direct expansion system. CONCLUSIONS Based on data of existing systems, calculations show real increase of energy consumptions of indirect systems. This increase raises when products have to be kept at low temperature. First on-site measurements confirm calculation predictions, that is saturated temperatures at the compressor intake significantly lower for indirect systems. Competitive solutions are under evaluation in Europe so that balanced comparisons can be performed. Comparison criteria shall include maintenance, energy consumption, operation costs and impact of refrigerant emissions. References [1] Inlow, S.W. and Groll, E.A. A Performance Comparison of Secondary Refrigerants. In Proceedings of 1996 International Refrigeration Conference at Purdue. July 23-26, West Lafayette, USA. pp. 357-362. [2] Terrel, W., Mao, Y. and Hmjak, P. Tests of Supermarket Display Cases when Operating with Secondary Refrigerants. In Proceedings of 1997 International Conference on Ozone Protection Technologies. November 12-13, Baltimore, USA. pp. 176-186. [3] Hmjak, P. The Benefits and Penalties Associated with the Use of Secondary Loops. ASHRAE/NIST Refrigerants Conference. October 1997. pp. 85-95. 269