CI/SfB (57) Uniclass Pr_30_59_96 December 2017 TRICKLE VENTILATORS...

The Glidevale range of Fresh wall

Invisivent EVO < Overframe flap ventilators

BACKGROUND VENTILATION SOLUTIONS FOR DOMESTIC BUILDINGS

COUNTER-FLOW, HIGH-EFFICIENCY HEAT RECOVERY UNIT IDEO ECOWATT

HRU SINGLE DWELLING HOUSES - ENERGY RECOVERY VENTILATION SYSTEMS WITH HEAT EXCHANGER AKOR BP HR Series

IDEO 325 ECOWATT. Counter-flow, high-efficiency heat recovery unit IDEO 325 ECOWATT. Low noise. Heat recovery units. Wireless programmable control

CBH - Active Chilled Beam. Halton CBH. Active Chilled Beam

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

Installation manual Mori HR

DX SYSTEM HEAT RECOVERY ENHANCED BY DEMAND CONTROLLED VENTILATION

BXC AIR EXHAUST GRILLE FOR MECHANICAL VENTILATION WITH AUTOMATIC AIRFLOW CONTROL

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM

S ILENT Series INSTALL SILENCE, INSTALL QUALITY OF LIFE. The Quietest Extractors in the World in their Category 26,5

CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT

NTD-125-*, NTD-204-* & NTD-220-* Nuaire Round & Rectangular Thermal Ducting Installation Guide

AIR HANDLING UNITS ASSET REFERENCE: DESIGN AHU 1 AHU 2

Ceiling diffusers. Type DLQL

Maintenance instructions for Duco's Ventilation systems

CLIMA CANAL HYBRID CLIMA CANAL. Low Water Temperature system LOW TEMPERATURE SYSTEM / HEATING AND COOLING LOW TEMPERATURE SYSTEM / HEATING

FRESHVENT. Select a product. Home/Freshvent

KLIMA Active Chilled Beams

BRIZA_038. EC MOTOR Briza Hybrid: High performance technology

System architecture. Air treatment Index

SERVICE MANUAL. WHITE KNIGHT CL43 Reversing Integrated Dryer - UK Technical Data Exploded Views Wiring Diagram Parts List

Fan-and-filter units 4.3. Features. Fast assembly. Application diversity and functions

CHH - Active Chilled Beam. Halton CHH. Active Chilled Beam

Mobile Air Conditioner Instruction Manual Model TC-N9KM

KUDOS. Instruction leaflet

BATHROOM EXTRACT FANS SILENT-100 Series

Integra. Integra Plus EC MVHR. Installation & Commissioning. Stock Ref. N EC Integra Plus EC PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT.

CONDOR. Supply air ceiling QUICK FACTS

VENTILATION UNITS. local ventilation units with heat recovery KORASMART KORASMART KORASMART KORASMART KORAVENT KORAVENT KORAVENT KORAVENT

Small Room Heat Recovery Ventilation

FHE. Dehumidifiers for radiant cooling systems with heat recovery. Display. Versions

ACCESSORIES ITEM NUMBER. Digital timer, burning and ventilating. RT1, RT2, RT3 IT1 DA1 Thermostat for CH 12/18. fault detector.

Type CODE Speed Heating Cooling

BRIZA EC 12 HYBRID. Low Water-Temperature system LOW TEMPERATURE SYSTEM / HEATING AND COOLING

Use. Worth noting. Key figures. Installation. linx industries chilled beams. the beam is mounted on a standard T-support.

Square Ceiling Diffusers : All extruded aluminum constructions. Opposed blade damper is adjustable from face of diffuser. Available in square and

RESIDENTIAL VENTILATION DUCTING SOLUTIONS

Heat recovery unit RDKS

Rytons RytDuct. Flat Channel Ducting and Components. 100mm, 125mm and 150mm Ranges Available. Issue 13 July 2012

Installation and operating instructions. DK energy storage and DK energy buffer

condenciat cl Condensing units Outdoor condensing unit Variable speed propeller fan Use Description for direct expansion applications

GLOBAL LP. Ceiling-mounted ventilation unit with plate heat exchanger

CASA. W5 Smart. Installation, commissioning and maintenance instructions. W5_d_EN-t

NT 65/2 Eco Me. On-board storage. Integrated drain hose (oil-resistant)

PLEASE READ ALL SECTIONS OF THIS GUIDE BEFORE COMMENCING YOUR INSTALLATION AND IN CONJUNCTION WITH YOUR DRAWINGS.

G Installation manual Solitude - dmev unit

INSTALLATION GUIDE. Isodrive / V1.0

KOG LN. Low Noise Chilled Water Cassettes Models 09, 12 & to 6.10kW to 5.10kW. 330 to 920 m3/h

TOPAZE CONTEMPORARY WINDOW. Architect: Opera Architecte Photography: J.C. Ballot

TopVent Design Handbook

Ceiling air diffuser INDULTHERM INDULTHERM-e

66 on. Central ventilation system ZLS-DV EC according to DIN Central ventilation system ZLS EXTRACT AIR FIRE PROTECTION OUTSIDE AIR

TECHNICAL SPECIFICATION

Swegon Home Solutions CASA. W3 Smart. Installation, commissioning and maintenance instruction. W3_f_EN-t

Heat Recovery ventilation Dee Fly Cube 550 Field of application Description Advantages Range Technical details Installation Remote controls Servicing

CLIMA CANAL Lyngson as

INDEX. Main components 3. General features and description of the components 4

Primo Hotel. General. Indoor climate units for hotel rooms

ROOM-BY-ROOM DEMAND CONTROLLED HEAT RECOVERY VENTILATION

QUATRO CANAL 2019.EX

Residential Heat Recovery Ventilation. REHVA European Guidebook No 25

KITCHEN EXTRACTORS K Series

Installation Manual for BR500

Dee Fly Cube 300 and 370. Heat Recovery ventilation

EHH SERIES DRAW THROUGH FAN COILS CFM

Instruction Manual. Model: EPA 16 Portable Airconditioner

CLIMA CANAL. Complete climate control and high power

WALL MOUNTED AIR CONDITIONER RANGE THE PERFECT CLIMATE.

Portable Air Conditioner USER MANUAL

TECNAIR LV C series Close control air conditioners

TECNAIR LV C series Close control air conditioners

SILENT 12 PORTABLE AIR CONDITIONER USER MANUAL

CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT. Cooling

CHILLED BEAM CASSETTE IQ STAR LYRA

Swegon Home Solutions CASA. W9 Smart. Installation, commissioning and maintenance instruction. W9_e_EN-t

WOLF WARM AIR CURTAIN

Adconair 76. Comfort air conditioning unit with counterflow plate heat exchanger. AIR VOLUME FLOW: 2,600 23,600 m³/h

vortice.com RESIDENTIAL VENTILATION VORT HRW 20 MONO RANGE Decentralized heat recovery units NEW

enviroblinds external blinds & shutters the secret to low carbon comfort

SABIANA ENVIRONMENTAL COMFORT. Air Conditioning Futura Fan Coil Units ICIM

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

GLOBAL RX. Ventilation unit with rotary heat exchanger

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

Mechanical Ventilation with Heat Recovery: Designing and implementing a robust and effective ventilation system

Portable Air Conditioner

SINGLE-ROOM ENERGY RECOVERY VENTILATORS

NT 27/1. Cartridge filter with float. Robust bumper. Robust metal latches

energy efficient air curtains technical data and controllers

VA 150 A, VA 150 P WINDOW EXTRACT FAN. Installation and Wiring Instructions V/1/50Hz

HATCHES & VENTS. Roof hatches - Camec Roof hatches Vents and cowls...208

ATC Heating Devices. P. 1 ATC Heating Devices

Recessed. Air Curtain. Fig 1. Recessed air curtain

SELECTION GUIDE AIR PURIFICATION AND CENTRALISED MECHANICAL EXHAUST VENTILATON

CENTRAL AIR CONDITIONER SPLIT SYSTEM

YORK Close Control units

Transcription:

AIR VENTS (AIR INLETS) REGULATIONS Air must be able to circulate from the dry to the damp rooms, therefore, the dining rooms, bedrooms and living rooms must have inlet openings. MOUNTING ALTERNATIVES The air vents must be placed more than 1.80 m above floor level. IN THE ROLLER BLIND BOX IN THE WINDOW FRAME IN WALL WITH SOUND ATTENUATOR Facade cap WITH SOUND ATTENUATOR Facade grille Facade cap AIR VENTS MODELS Self-regulating air vents: The airflow circulating through the vent is maintained constant. An inner flexible element avoids sudden increases of airflow caused by wind blowing onto the facade of the building. Humidity-adjustable air vents: The airflow circulating through the vent depends on the relative humidity of the indoor air. When it is high, a flap located inside the vent keeps the air passage totally open (maximum flow), while when the relative humidity indoors is low, the flap closes (minimum airflow). 840

SELF-REGULATING AIR VENTS (AIR INLETS) EC-N Self-regulating air vents LxAxH (mm): 390 x 24 x 20 Self-regulating air vents, manufactured in white or brown polystyrene. Guaranteeing air renewal in a home through the main rooms (Living room, sitting room and bedrooms). Enabling an airflow of 22, 30 and 45 m 3 /h. Fitted either to carpentry elements (in openings measuring x mm) or connected to a wall feedthrough tube. The EC N air vent can have a cover that includes an insect grille, available in white or brown. EC-N 22 Blanco White 13 22 35 EC-N 30 Blanco White 13 30 34 EC-N 45 Blanco White 13 45 33 ECA Plastic self-adjusting acoustic air vents LxAxH (mm): 422 x 45 x 45 Self-regulating air vents, manufactured from injection moulded polystyrene and available in three air volume range (22, 30, 36 and 45 m 3 /h). Fitted in openings measuring x mm. Suitable for installation on window joinery by crews. The air inlet acoustic element is placed on the indoor side while the cover is fitted on the external side of the joinery. An additional acoustic element can be slot into the air inlet (ECA+RA). ECA 22 Blanco White 13 22 39 ECA 30 Blanco White 13 30 39 ECA 36 Blanco White 13 36 38 ECA 45 Blanco White 13 45 37 841

SELF-REGULATING AIR VENTS (AIR INLETS) ECA-RA Plastic self-adjusting acoustic air vents with additional acoustic element LxAxH (mm): 422 x 45 x 69 Auto-adjustable air vents with an identical design to ECA (See above), the ECA-RA have an acoustic frame for greater attenuation of transmitted noise. ECA-RA 22 Blanco White 13 22 41 ECA-RA 30 Blanco White 13 30 41 ECA-RA 36 Blanco White 13 36 39 ECA-RA 45 Blanco White 13 45 39 SILEM KIT Self-regulating air vents with sound attenuator Ø mm Facade grille Silenced air vent Fitted into the wall with an external grille and the interior silenced vent embedded with a sheet metal sleeve 5 mm in diameter. Ø (mm) Colour RAL Airflow (m 3 /h) Dn,e,w (ctr) SILEM KIT 22 5 White 13 22 47 SILEM KIT 30 5 White 13 30 47 842

HUMIDITY-ADJUSTABLE AIR VENTS (AIR INLETS) EC-HY Humidity-adjustable air vents LxAxH (mm): 400 x 40 x 30 Humidity-adjustable air vents for renewing air in the main rooms of flats and detached homes. They guarantee a variable flow of 6 to 45 m 3 /h according to the degree of humidity in the room, for a pressure difference of 20 Pa, enabling partial elimination of transversal ventilation, which is a cause of wasted energy. Fitted in openings measuring x mm. EC-HY 6/45 Blanco White 13 6 / 45 33 ECA-HY Humidity-adjustable acoustic air vents LxAxH (mm): 420 x 45 x 40 Humidity-adjustable air vents for renewing air in the main rooms of flats and detached homes. They guarantee a variable flow of 6 to 45 m 3 /h according to the degree of humidity in the room, for a pressure difference of 20 Pa, enabling partial elimination of transversal ventilation, which is a cause of wasted energy. ECA-HY 6/45 Blanco White 13 6 / 45 37 Technical characteristics EC-HY 6/45 ECA-HY 6/45 Airflow in m 3 /h Relative humidity HR% 843

HUMIDITY-ADJUSTABLE AIR VENTS (AIR INLETS) ECA-HY RA Humidity-adjustable air vents with acoustic frame LxAxH (mm): 420 x 45 x 64 Humidity-adjustable air vents with an acoustic frame for renewing air in the main rooms of flats and detached homes. The acoustic frame offers great noise attenuation. They guarantee a variable flow of 6 to 45 m 3 /h according to the degree of humidity in the room, for a pressure difference of 20 Pa, enabling partial elimination of transversal ventilation, which is a cause of wasted energy. ECA-HY 6/45 RA Blanco White 13 6 / 45 39 SILEM KIT HY Humidity-adjustable air vents with sound attenuator Ø mm Facade grille Silenced air vent Fitted into the wall with an external grille and the interior silenced vent embedded with a sheet metal sleeve 5 mm in diameter. Ø (mm) Colour RAL Airflow (m 3 /h) Dn,e,w (ctr) SILEM KIT HY 5 5 White 13 6 / 45 39 844

AIR VENTS (AIR INLETS): ACCESSORIES SILEC KIT Wall feed through tube sound attenuator GRF 5 MAC 30 MPR SILEC EC-N SILEC MPR MAC 30 MNG PSM GRF 5 Application Sound attenuator (535 x 195 ext) (500 x 160 int) Ø 5 mm Plastic adaptor piece. Length: 50 mm Acoustic tube 30 m 3 /h 51 db(a). Length: 140 mm PVC Ø 5 tube to embed in the wall. Length: 200 mm Wall grille Ø 5 with 150 x 150 mm clips Wall feed through tube silencer manufactured from polystyrene. Fitted to any wall surface after perforating the wall and embedding a 5 mm diameter PVC tube. Can be fitted either to the to the inner part of the wall coating or to the front part, accessible and can be dismantled to facilitate maintenance. The SILEC KIT consists of: SILEC, MPR, MAC 30, MNG PSM and GRF 5. Dn,e,w (ctr) SILEC KIT + EC-N 22 51 SILEC KIT + EC-N 30 51 SILEC KIT + EC-N 45 49 SILEC KIT + ECA-HY 6/45 50 The SILEC KIT does not include the sound attenuator MNG M1-M2 Connector Dimensions LxAxH (mm) MNG M1 L70 360 x 70 x 15 MNG M1 L0 360 x 0 x 15 MNG M1 L200 360 x 200 x 15 MNG M2 L250 365 x 250 x 18 MNG M1 Adjustable connector (male) MNG M2 Fixed connector (female) Connectors made of galvanized sheet steel 0.75 mm thick. Used for fitting air inlets in walls. Adapted to the air inlet grilles or air vents measuring x mm. 845