Infinity M300+ Telemetry

Similar documents
Infinity M300 Patient Worn Monitoring

D Moving beyond telemetry INFINITY M300

Training Gas Detection Level 3 Maintenance and Repair

Training Gas Detection Level 2 User and Calibration. Basic Information

Training Authorised Gas Tester Level 1. Basic Information

On-site & Shutdown Safety Service CSE Monitoring

Oxylog VE300 Emergency & Transport Ventilation

Dräger Catalytic Ex-Sensors DrägerSensors

Dräger Pac 5500 Single-Gas Detection Device

Oxylog VE300 Emergency & Transport Ventilation

Catalytic Bead DrägerSensor Sensors for Fixed Gas Detectors

Dräger Pac 6000 Single-Gas Detection Device

Dräger Bodyguard 1000 Warning Device

Dräger Pac 8500 Single-Gas Detection Device

Dräger OR Lights Simply good light

Dräger Pac 8000 Single-Gas Detection Device

Dräger Bump Test Station Calibration and Bump Testing

Dräger PointGard 2100 Detection of toxic gases and vapours

DPM Summary of Features and Benefits

Dräger VVP 1000 System Components

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

5/ 5i/ 5c/ 7/ 7i/ 7c/ 5 elite/ 5i elite/ 5c elite/ 7 elite/ 7i elite/ 7c elite

Dräger Polytron 5720 IR Toxic Gas Detection

Dräger Pac 3500 Single-Gas Detection Device

Dräger Configuration and Evaluation Software

Dräger PIR 3000 Detection of flammable gases and vapours

Dräger REGARD -1 Control System

1 Appendix - Product Specifications

Oxylog VE300 Emergency & Transport Ventilation

Dräger Polytron 8720 IR Detection of carbon dioxide

Dräger FRT 1000 / ETR 1000 Location Devices

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Dräger Pac 7000 Single-Gas Detection Device

Dräger Polytron 5720 IR Detection of carbon dioxide

Dräger X-pid 9000 / 9500 Multi-Gas Detection

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Dräger X-zone 5500 Area Monitoring

Dräger GS01 (wireless) Detection of flammable gases and vapours

Portable wet chemical extinguishers

VarioAir Medical Suction Solutions Consumables and Accessories

Dräger VentStar Helix heated (N) plus Consumables and Accessories

Foam Extinguisher AB - composite Portable foam extinguishers

GS01 (wireless) Detection of flammable gases and vapours

Dräger X-am 2500 Multi-Gas Detector

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Catalytic Ex-Sensors DrägerSensors

Powder Extinguisher ABC - composite Portable powder extinguishers

Tropic 2.0 ultrasonic nebuliser

Dräger REGARD 3900 Series Control System

Dräger Polytron 7000 Detection of toxic gases and oxygen

VarioVac vacuum regulators Consumables and Accessories

Infinity M540 Patient Monitor

PM-9000 Express Portable Patient Monitor

Powder Extinguisher ABC (stored pressure) Portable powder extinguishers

Dräger X-plore 8000 Powered Air-Purifying Respirator (PAPR)

D Safe, realistic, reliable DRÄGER FIRE TRAINING SYSTEMS

PATIENT MONITORING SYSTEMS

Dräger QuadGard Control System

Dräger X-am 5000 Multi-Gas Detection

PATIENT MONITORING SYSTEMS

Foam Wheeled Extinguisher AB Movable fire extinguishers

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger X-am 2500 Multi-Gas Detection

MRI Patient Monitoring System (Model )

PATIENT MONITORING SYSTEMS

SureSigns VS4. Vital Signs Monitor Technical Data Sheet

Dräger Flame 5000 Flame Detection

OMNI TOUCH SCREEN PATIENT MONITOR

Dräger X-am 5000 Multi-Gas Detector

The SharpEye 40/40I (IR3) Flame Detection

Dräger Flame 2100 (UV) Flame Detection

Vitalmax 4000 CL Product Specifications

Reference Case: Avera Heart Hospital Data-Driven Approach Helps Hospital Build Effective Clinical Alarm Management Program

HeartStart XL+ Configuration Worksheet

Dräger Pulsar 7000 Series Detection of flammable gases and vapours

Dräger P4000 Pressure and Leak Testing

Dräger Flame 5000 Flame Detection

B40 Patient Monitor. Affordable clinical excellence. Advanced clinical parameters. Ease of use for fast decision-making. Performance and reliability

Omni (K) PATIENT MONITOR

The SharpEye 40/40L4-L4B (UV/IR) Flame Detection

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Dräger UCF 7000 Thermal Imaging Camera

Dräger Pac 3500 Single-Gas Detection Device

Dräger Flame 2350 (UV&IR) Flame Detection

Dräger VARIOx-2. Electronical measuring device for the gas concentration measurement

Dräger X-zone 5500 Multi-Gas Detection Device

MT Always in focus BABYTHERM

Dräger PIR 7200 Detection of toxic gases and oxygen

Dräger Flame 2370 (UV&IR) Flame Detection

Product Specifications

Dräger DM-6 BG 4 Mask Dryer Workshop Systems

The SharpEye 40/40M (Multi IR) Flame Detection

Dräger Flame 2700 (Multi-IR) Flame Detection

Dräger X-am 7000 Multi-Gas Detection

Multi-Parameter Patient Monitor

Dräger X-dock 5300/6300/6600 Calibration and Bump Testing

Dräger Flame 2500 (IR3) Flame Detection

Dräger REGARD -1 Control System

Dräger Polytron 8200 Stationary gas detector (CatEx)

Transcription:

Infinity M300+ Telemetry The Infinity M300+ provides continuous surveillance of telemetry patients using the hospital s existing WiFi network The compact size supports patient mobility while the integrated color screen continuously displays patient vital signs and waveforms In addition, the M300+ produces visible and audible alarms to alert you to changes in your patient s condition Compact and lightweight design Intended to encourage patient mobility while fully monitored both within and outside the care unit High resolution color display Enables easy-to-see patient vital signs and ECG waveforms Multi-function key pad Designed for ease of use Expanded network functionality Offers expanded network options and supports wireless encryption for enhanced security Swappable battery Can be easily removed when power is low and replaced with a fully-charged battery D-23347-2017

02 Infinity M300+ Benefits Ease of Use The M300+ is designed for ease of use featuring an easy-to-see color display, multi-function key pad and easy battery replacement that retains all patient data during the process Supports Clinical Workflow Battery replacement is complementary to patient care needs and is adaptable to individual care unit schedules or on an as-needed basis Designed for Patient Comfort The compact, lightweight device was designed to be worn comfortably while enabling increased mobility Expanded Network Functionality The M300+ offers expanded network options, including IEEE 80211b/g/n (24 GHz) or 80211 a/n (5GHz) It supports wireless encryption, including WPA2 Enterprise Mode (EAP-TLS and PEAP methods) for enhanced security And it has an embedded FIPS-validated Wi-Fi module for data encryption to help maintain confidentiality and data integrity System Components Infinity CentralStation Wide Viewing comprehensive real-time and retrospective clinical data supports you in making the most effective care decisions for your patients Infinity CentralStation Wide brings hemodynamic vital signs together with values from interfaced ventilators and anesthesia devices D-7315-2016

Infinity M300+ 03 System Components Infinity M300+ Battery Charging Station The wall-mountable or counter top M300+ battery charging station recharges up to 10 M300+ batteries at a time The charging station provides auto shut-off to prevent overcharging, and indicates charging status through illuminated LEDs D-25743-2017

04 Infinity M300+ Technical Data SUPPORTED PARAMETERS ECG Available leads Leads analyzed Detected events/rhythms HR level alarm adjustment range Heart rate measurement range Accuracy Degree of protection against electrical shock 3-wire lead set: I, II, or III 5-wire lead set: I, II, III, avl, avr, avf, V 6-wire lead set: I, II, III, avl, avr, avf, V, V+ 6-wire lead set with Infinity TruST: I, II, III, avl, avr, avf, dv1, V2, dv3, dv4, V5, dv6 Any two user-selected ECG leads (simultaneously), or any one user-selected ECG lead Asystole, Ventricular Fibrillation, Ventricular Tachycardia, Bradycardia, Ventricular Run, Accelerated Idioventricular Rhythm, Supraventricular Tachycardia, Ventricular Couplet, Ventricular Bigeminy, Tachycardia, Pause, Artifact, PVC/min 20 to 300 bpm 15 to 300 bpm ± 2 bpm or ± 1%, whichever is greater Type CF Defibrillation protection In accordance per IEC 60601-2-27 Bandwidth or resolution Filter Monitoring: 05 40 Hz Sweep speed 25 mm/sec ± 10% QRS detection Electrosurgery and cautery Pacer Detection Amplitude Width (dp) Precautions Amplitude: 05 50 mv Duration: Adult: 70 120 ms Pediatric: 40 120 ms Not intended for use during ESU procedures Leads I and (II or lll) ± 2 to ± 700 mv 02 to 20 ms Contains a tiny magnet which generates an extremely low static magnetic field of approximately 2 gauss at 127 mm (05 in) distance Please refer to the manufacturer s Instructions for Use of any third party medical devices in the patient vicinity for compatibility ST Segment Analysis Leads analyzed Isoelectric point ST measurement point ST complex Update interval ST measurement and alarm limit ranges ST measurement accuracy ST measurement resolution 3-wire: I, II, or III 5-wire: I, II, III, avr, avl, avf, V 6-wire: I, II, III, avr, avl, avf, V, V+ 6-wire with Infinity TruST 12-lead: I, II, III, avr, avl, avf, dv1, V2, dv2, dv3, dv4, V5, dv6 Adjustment range: start of QRS complex to fiducial point; Default: QRS onset -28 ms Adjustment range: fiducial point to end of QRS complex; Default: QRS offset +80 ms Length: 900 msec (250 samples) Frequency response: 005 to 40 Hz 15 seconds -150 to 150 mm, -15 to 15 mv ± 05 mm (005 mv) or 15% RTI (with respect to input) whichever is greater for all leads, excluding STVM and STCVM 01 mm, 001 mv

Infinity M300+ 05 Technical Data Pulse Oximetry (optional) Parameter display Pulse oximetry oxygen saturation percentage (SpO 2 ), pulse rate Measuring method Absorption-spectrophotometry Measurement and display range SpO 2 : 1 100% Pulse rate: 30 250 bpm Calibration range 70 100% Display update period 2 seconds nominal Maximum hold from previous update 30 seconds (in the event of artifact or other error) SpO 2 Alarm Range 20 to 100% Pulse Rate Alarm Range 30 to 240 bpm Accuracy SpO 2 0 to 69% not specified 70 to 100% sensor-specific as follows: Masimo LNCS Sensors SpO 2 accuracy 1, 2, 3, 4 : LNCS DCI, LNCS DCIP, LNCS Adtx, LNCS Pdtx Not specified Pulse rate accuracy ±3 bpm or ±3 %, whichever is greater Low perfusion accuracy, SpO 2 ±2 % Low perfusion accuracy, pulse rate ±3 bpm or ±3 %, whichever is greater Masimo RD SET Sensors SpO 2 accuracy 1, 2, 3, 4 : RD SET Adt, RD SET Pdt ±2 % Pulse rate accuracy ±3 bpm or ±3 %, whichever is greater Low perfusion accuracy, SpO 2 ±2 % Low perfusion accuracy, pulse rate ±3 bpm or ±3 %, whichever is greater Nellcor Sensors SpO 2 accuracy 1, 2, 3, 4 : OxiMax MAX-A, OxiMax MAX-AL, OxiMax MAX-P, DS100A ±3 % Dräger Sensors SpO 2 accuracy 1, 2, 3, 4 : MS16444 disposable foam pedi, MS16445 disposable foam ad, MS16449 disposable vinyl ad, MS16448 disposable vinyl pedi, MS13235 reusable sensor ±2 % NOTES: 1 Since SpO 2 measurements are statistically distributed, only about two-thirds of those measurements can be expected to fall within ±1 Arms of the value measured by a CO-oximeter 2 These accuracies have been validated using blood samples obtained from healthy adult volunteers during induced hypoxia studies in the range of 70 to 100% SpO 2 against a laboratory CO-oximeter and ECG monitor 3 SpO 2 accuracies are expressed as ± X % between indicated saturation levels This variation of the SpO 2 measurement equals ±1 Arms of the value measured by a CO-oximeter 4 The pulse rate accuracy has been validated on healthy adult volunteers during induced hypoxia studies in the range of 70 to 100 % SpO 2 against a laboratory CO-oximeter and ECG monitor This variation equals ±1 Arms of the pulse rate value measured by the ECG monitor User Interface Controls Alarms 6 function keys: alarm pause, view screen, staff alert, record/mark event, up/down scroll Audible & visible alarm indication (user controlled) 3 severity levels: Life threatening, Serious, Advisory

06 Infinity M300+ Technical Data Display Size/viewing area Resolution Communications Network Wireless encryption Radio power output Physical Specifications Size, H x W x D with battery attached Weight Cooling Connections 55 cm (217 in) diagonal LCD 220 x 176 pixels IEEE 80211b/g/n (24 GHz); 80211a/n (5 GHz) WPA2 Personal Mode; WPA2 Enterprise Mode 30 mw (24 GHz) / 25 mw (5 GHz) 1575 mm x 811 mm x 306 mm (62 in x 319 in x 12 in) 310 g +/- 5g (1093 oz) Convection ECG, communication port for SpO 2, programming cable Electrical Specifications Power source Battery operating time Rechargeable 36 V lithium-ion swappable battery, available from Dräger ECG only: 22 h ECG and continuous SpO 2 : 18 h Duration of operation varies according to use of display, alarms, and wireless environment (roaming) NOTE: The duration of the battery charge for the M300+ may be reduced by characteristics of the wireless environment such as signal quality, power levels, power-save mode, etc The battery operating life can also gradually diminish over time Environmental Requirements Temperature Operating Storage Humidity (non condensing) Operating Storage 0 C to 40 C (32 F to 104 F) -20 C to 60 C (- 4 F to 140 F) 10% to 85% 10% to 85% Atmospheric pressure Operating Storage 647 to 106 kpa 50 to 106 kpa Free fall IEC 60068-2-32, Procedure 1 Height of fall: 1 m Number of falls: 1 on each of six surfaces Infinity M300+ battery charging station Physical Specification Size, H x W x D Weight, with 0 batteries Weight, with 10 batteries Cooling 1016 x 508 x 1143 mm (4 x 20 x 45 in) 146 Kg (325 lb) 246 Kg (54 lb) Convection Electrical Specifications Input voltage 100 V to 240 V AC CAUTION: Use a surge protector with all electrical hookups Input frequency (Hz) 50 Hz to 60 Hz AC inputs Protection Class Class 1

Infinity M300+ 07 Technical Data Mode of Operation Swappable battery recharging time Continuous 0 to 100 % within approximately 4 h Environmental Requirements Ambient pressure Temperature Operating: 65 to 106 kpa Storage: 50 to 106 kpa Operating: 0 to +35 C (32 to 95 F) Storage: -20 to +60 C (-4 to +140 F) Humidity (non-condensing) Operating: 10 % to 95 % Storage: 10 % to 95 % Masimo is a registered trademark of Masimo Corporation Nellcor and OxiMax are trademarks of Medtronic

08 Infinity M300+ Notes Not all products, features, or services are for sale in all countries Mentioned Trademarks are only registered in certain countries and not necessarily in the country in which this material is released Go to wwwdraegercom/trademarks to find the current status 91 04 886 1710-1 HQ PP Subject to modifications 2017 Drägerwerk AG & Co KGaA CORPORATE HEADQUARTERS Drägerwerk AG & Co KGaA Moislinger Allee 53 55 23558 Lübeck, Germany wwwdraegercom Manufacturer: Draeger Medical Systems, Inc 3135 Quarry Road Telford, PA 18969-1042, USA Locate your Regional Sales Representative at: wwwdraegercom/contact REGION DACH Drägerwerk AG & Co KGaA Moislinger Allee 53 55 23558 Lübeck, Germany Tel +49 451 882 0 Fax +49 451 882 2080 info@draegercom REGION EUROPE Drägerwerk AG & Co KGaA Moislinger Allee 53 55 23558 Lübeck, Germany Tel +49 451 882 0 Fax +49 451 882 2080 info@draegercom REGION MIDDLE EAST, AFRICA Drägerwerk AG & Co KGaA Branch Office PO Box 505108 Dubai, United Arab Emirates Tel +971 4 4294 600 Fax +971 4 4294 699 contactuae@draegercom REGION ASIA PACIFIC Draeger Singapore Pte Ltd 25 International Business Park #04-20/21 German Centre Singapore 609916 Tel +65 6308 9400 Fax +65 6308 9401 asiapacific@draegercom REGION NORTH AMERICA Draeger, Inc 3135 Quarry Road Telford, PA 18969-1042, USA Tel +1 800 4DRAGER (+1 800 437 2437) Fax +1 215 723 5935 infousa@draegercom REGION CENTRAL AND SOUTH AMERICA Dräger Panama S de RL 59 East Street, Nuevo Paitilla House 30, San Francisco Town Panama City, Panama Tel +507 377 9100 Fax +507 377 9130 servicioalcliente@draegercom