INSTALLATION INSTRUCTIONS

Similar documents
DC INVERTER MULTI-SYSTEM AIR CONDITIONER

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL

INSTALLATION INSTRUCTIONS

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW22AL AW28AL AW38AL AW42AL AW22AL AW28AL AW38AL

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER OUTDOOR UNIT: AE22AC/ACL/AH AE28AC/ACL/AH AE38AC/ACL/AH AE42AC/ACL/AH

TECHNICAL DATA & SERVICE MANUAL

Operating Instructions Air Conditioner

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

AUTO COOL DRY FAN SPEED AIR SWING OFF ON TIMER TIMER OFF/ON FAN SPEED MODE TEMP AIR SWING TIMER ON SET OFF CANCEL AC RC SET CHECK CLOCK RESET

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513

Installation manual. Branch kit 1:3 RBC-TRP100E AIR CONDITIONER (SPLIT TYPE) Model name: Installation manual. Air conditioner (Split type) 1 English

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: CAF94R5 CAF124R5 CAF94R

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: ASR609CL ASR612CL ASR609CL ASR612CL

Installation Manual PMV Kit RBM-PMV0363E RBM-PMV0903E

TEST RUN SERVICE MANUAL

INSTALLATION INSTRUCTIONS

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 128S5 FILE NO. SA 128S5 REFERENCE NO. SM700338

Operating Instructions Air Conditioner

Si REMOVAL PROCEDURE. 4.0/5.0/5.2/5.8/6.8/7.5 kw Class. Outdoor Unit Inverter Multi Type

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

Installation Instructions

Si REMOVAL PROCEDURE. 2.5/3.2/3.5 kw Class. Outdoor Unit Inverter Pair Type

DAIKIN AIR CONDITIONER

INSTALLATION MANUAL. BP (Branch Provider) Unit. Models BPMKS967A2B BPMKS967A3B BPMKS967B2B BPMKS967B3B. Installation manual BP (Branch Provider) Unit

SPLIT TYPE ROOM AIR CONDITIONER INSTALLATION MANUAL (PART NO )

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 93AH FILE NO. SA 93AH REFERENCE NO. SM700510

INSTALLATION INSTRUCTIONS CS-KS30NKU + CU-KS30NKUA CS-KS36NKU + CU-KS36NKUA

Installer manual AG-AA10. Air/air heat pump IHB GB AG-AA10-30 AG-AA10-40/50

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

INSTALLATION MANUAL AIR CONDITIONER OUTDOOR UNIT. Contents. PART No English. Français. For authorized personnel only.

MXZ-4B80VA MXZ-5B100VA INSTALLATION MANUAL

FLOOR-STANDING TYPE AIR CONDITIONER INSTALLATION MANUAL

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

INSTALLATION MANUAL. AIR CONDITIONER INDOOR UNIT (Wall Mounted Type) PART No Contents 1. SAFETY PRECAUTIONS. En-1. English.

Installation Instructions

INSTALLATION INSTRUCTIONS Split System Air Conditioner

FLEX MULTI SPLIT DUAL ZONE & TRI-ZONE INSTALLATION INSTRUCTIONS

INSTALLATION MANUAL. R410A Split Series. Model RXS24LVJU. Installation manual R410A Split series. Manual de instalación Serie Split R410A.

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

Installation Instructions

Installation and Operation Manual For Hunter Ceiling Fans /16/2004

Split-type Air-Conditioner

INSTALLATION MANUAL Duct Type Series MH FECA

Air Conditioner. user installation & manual manual. imagine the possibilities

Dishwasher Installation Instructions DW 24XT/DW 24XV

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

INSTALLATION MANUAL. R410A Split Series. Models RXS15LVJU RXS18LVJU. Installation manual R410A Split series. Manuel dinstallation Série split R410A

Installation Instructions

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

Installation Instructions

Installation Instructions T 9822 Gas Dryer. en - US, CA. To prevent accidents

Installation and Operation Manual. CMA12SB-0 Series. Horizontal/Side Discharge Condensing Units

Inverter Air Source Heat Pump Monobloc system

Installation Instructions

Installation Instructions

DLCSRA. INSTALLATION INSTRUCTIONS Outdoor Unit Ductless Split System Sizes 09 to 36 TABLE OF CONTENTS

CEILING SPEAKER SYSTEMS F-2352C

Installation Instructions

Built-In Dishwasher. Installation Instructions. BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT The dishwasher MUST be

INVERTER SPLIT - TYPE

Installation Instructions

INSTALLATION MANUAL COMFORT...BUILT TO LAST. 9,000, 12,000 and 18,000 BTU SINGLE-ZONE DUCTLESS MINI-SPLIT SYSTEM Heat Pump

AIR CONDITIONER OUTDOOR UNIT

CEILING SPEAKER SYSTEM F-122C INSTRUCTION MANUAL TABLE OF CONTENTS 7. REPAINTING THE SPEAKER SAFETY PRECAUTIONS... 2

INSTALLATION INSTRUCTIONS 2WAY VRF System Air Conditioner

Installation Instructions

Installation Instructions

Split-type Air-Conditioner

INSTALLATION INSTRUCTIONS FOR SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMP

INSTALLATION AND USER S MANUAL COOKER HOOD RS-600/A-S

Installation Instructions

FLOOR-STANDING SPLIT TYPE ROOM AIR CONDITIONER

Notices for installation

A PROUD HERITAGE OF EXPERIENCE & QUALITY DISHWASHER BR- DWSH01- S

SERVICE MANUAL FOR 6636A & 6636B SERIES TWO TON HIGH EFFICIENCY PACKAGED AIR CONDITIONERS

LONG BEACH 52" outdoor fans

Installation Manual. KS Series KS09 KS12 KS18 KS24 KS28. J3387_Kaden_Installer_Manual_ indd 1

AOYG18LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL. For authorized service personnel only. PART NO

INSTALLATION INSTRUCTIONS FOR 6636 SERIES PACKAGE AIR CONDITIONER

Installation Instructions

MODELS DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL FTXN50KV1B FTXN60KV1B. R410A Split Series

INSTALLATION INSTRUCTIONS

Safety Precautions (1)

ROOM AIR CONDITIONER INSTALLATION MANUAL

RAS-10JKVP-E RAS-10JAVP-E RAS-13JKVP-E RAS-13JAVP-E

INSTALLATION MANUAL. AIR CONDITIONER Indoor Unit (Duct type) PART No Contents. En-1 1. SAFETY PRECAUTIONS WARNING

General safety precautions English

Installation Instructions Built-In Dishwasher

General safety precautions English

Choosing the installation site. Installation. 07 Choosing the installation site

HNC-120BE-L/R-B HNC-150BE-L/R-B HNC-180BE-L/R-B HNC-210BE-L/R-B COUNTER SHOWCASE MODEL SERVICE MANUAL HOSHIZAKI

Transcription:

INSTALLATION INSTRUCTIONS Solenoid Valve Kit For 3WAY VRF System CZ-PXXXHR3 () IMPORTANT! Please Read Before Starting This solenoid Valve kit must be installed by the sales dealer or installer. This information is provided for use only by authorized persons. For safe installation and trouble-free operation, you must: Carefully read this instruction booklet before beginning. Follow each installation or repair step exactly as shown. This solenoid Valve kit shall be installed in accordance with National Wiring Regulations. Pay close attention to all warning and caution notices given in this manual. This symbol refers to a hazard or unsafe WARNING practice which can result in severe personal injury or death. CAUTION This symbol refers to a hazard or unsafe practice which can result in personal injury or product or property damage. If Necessary, Get Help These instructions are all you need for most installation sites and maintenance conditions. If you require help for a special problem, contact our sales/service outlet or your certified dealer for additional instructions. In Case of Improper Installation The manufacturer shall in no way be responsible for improper installation or maintenance service, including failure to follow the instructions in this document. SPECIAL PRECAUTIONS WARNING When Wiring ELECTRICAL SHOCK CAN CAUSE SEVERE PERSONAL INJURY OR DEATH. ONLY A QUALIFIED, EXPERIENCED ELECTRICIAN SHOULD ATTEMPT TO WIRE THIS SYSTEM. Do not supply power to the unit until all wiring and tubing are completed or reconnected and checked. Highly dangerous electrical voltages are used in this system. Carefully refer to the wiring diagram and these instructions when wiring. Improper connections and inadequate grounding can cause accidental injury or death. Connect all wiring tightly. Loose wiring may cause overheating at connection points and a possible fire hazard. Provide a power outlet to be used exclusively for each unit. Provide a power outlet exclusively for each unit, and full disconnection means having a contact separation in all poles must be incorporated in the fixed wiring in accordance with the wiring rules. To prevent possible hazards from insulation failure, the unit must be grounded. This equipment is strongly recommended to be installed with Earth Leakage Circuit Breaker (ELCB) or Residual Current Device (RCD). Otherwise, it may cause electrical shock and fire in case of equipment breakdown or insulation breakdown. When Transporting Be careful when picking up and moving the indoor and outdoor units. Get a partner to help, and bend your knees when lifting to reduce strain on your back. Sharp edges or thin aluminum fins on the air conditioner can cut your fingers. When Installing Select an installation location which is rigid and strong enough to support or hold the unit, and select a location for easy maintenance. In a Room Properly insulate any tubing run inside a room to prevent sweating that can cause dripping and water damage to walls and floors. The produces some refrigerant noise. If it is to be installed in a quiet place such as a hospital, library or hotel, it is strongly recommended that the be installed in the ceiling of a corridor, etc. apart from the room. CAUTION Keep the fire alarm and the air outlet at least.5 m away from the unit. 856369862000 CV62333256

When Connecting Refrigerant Tubing Pay particular attention to refrigerant leakages. CAUTION When performing piping work, do not mix air except for specified refrigerant (R0A) in refrigeration cycle. It causes capacity down, and risk of explosion and injury due to high tension inside the refrigerant cycle. If the refrigerant comes in contact with a flame, it produces a toxic gas. Do not add or replace refrigerant other than specified type. It may cause product damage, burst and injury, etc. Ventilate the room immediately, in the event that is refrigerant gas leaks during the installation. Be careful not to allow contact of the refrigerant gas with a flame as this will cause the generation of toxic gas. Keep all tubing runs as short as possible. Apply refrigerant lubricant to the matching surfaces of the flare and union tubes before connecting them, then tighten the nut with a torque wrench for a leak-free connection. Check carefully for leaks before starting the test run. Do not leak refrigerant while piping work for an installation or re-installation, and while repairing refrigeration parts. Handle liquid refrigerant carefully as it may cause frostbite. In case of malfunction of this appliance, do not repair by yourself. Contact the sales dealer or service dealer for repair. CAUTION Others Ventilate any enclosed areas when installing or testing the refrigeration system. Leaked refrigerant gas, on contact with fire or heat, can produce dangerous toxic gas. Confirm after installation that no refrigerant gas is leaking. If the gas comes in contact with a burning stove, gas water heater, electric room heater or other heat source, it can cause the generation of poisonous gas. CAUTION Do not sit or step on the unit, you may fall down accidentally. When Servicing Turn the power OFF at the main power box (mains) before opening the unit to check or repair electrical parts and wiring. Keep your fingers and clothing away from any moving parts. Clean up the site after you finish, remembering to check that no metal chips or bits of wiring have been left inside the unit. WARNING This product must not be modified or disassembled under any circumstances. Modified or disassembled unit may cause fire, electric shock or injury. Do not clean inside the indoor and outdoor units by users. Engage authorized dealer or specialist for cleaning. 2

. Accessories Part Name Figure Type 56 Type 656 Q'ty Type 856 Type 60 Remarks Washer 8 8 8 8 For suspension bolts Tapping screw ( L=8mm) 6 2 32 6 For Solenoid Valve Relay Kit Wire holder 6 8 For Solenoid Valve Relay Kit wiring Solenoid Valve Relay Kit 6 8 Clamper 9 3 7 9 For electrical wiring Protection tube (Liquid) For Solenoid Valve Kit (connecting to the left side) Protection tube (Discharge) For Solenoid Valve Kit (connecting to the left side) Protection tube (Suction) For Solenoid Valve Kit (connecting to the left side) 2. Positioning for Installation The produces some refrigerant noise. If it is to be installed in a quiet place such as a hospital, library or hotel, it is strongly recommended that the be installed in the ceiling of a corridor, etc. apart from the room. Room Room Room Room Strongly recommended installation unit Solenoid valve kit unit Avoid unit unit Corridor Corridor Solenoid valve kit NOTE After the power is turned on, the sound of the solenoid valve coil may sometimes occur. Note that this is not a fault. The sound level will gradually become small at the time of starting operation. 3

Be sure to secure the to the structure and the suspension bolts. Do not place the solenoid valve kit directly on the ceiling surface. When installing the, remember to install it with the top surface facing upward. (See the figure shown in the subsection "How to use the fittings" in " 3. Valve Dimensions and Hanging Method.") Provide a service space as shown in the below figure. Never conduct drilling or welding on the sheet metal. Do not cover air holes. Provide the inspection hole as shown in the below figure. 00 or more Secure the service space for the local piping Service space 200 or more Upper side Type 56, 656, 60 300 or more 300 or more Type 856 300 or more 300 or more 50 or more 50 or more Front side Service space Front side Service space Inspection hole (5050) Inspection hole (5050) Unit : mm

3. Valve Dimensions and Hanging Method There are types of s: type 56, 656, 856 and type 60. The corresponding indoor unit model capacities are shown in the table at right. Solenoid Valve Kit CZ-P56HR3 CZ-P656HR3 No. of port 6 Unit Capacity per port Type 56 or under CZ-P856HR3 8 CZ-P60HR3 Type 60 or under A B (Suspension bolt pitch) C D E F GSUCTION HDISCHARGE JLIQUID Type 56 99 87 807 5 5 7 Type 656 297 253 85 23 5 55 5 67 3 Type 856 675 63 563 53 53 5 Type 60 99 87 807 207 55 5 3 Unit : mm 67 * 23 7 3 A B (Suspension bolt pitch) C D E D E D E D 3 97 ** F 7 62 2 JLIQUID HDISCHARGE GSUCTION GSUCTION HDISCHARGE JLIQUID 77 (Suspension bolt pitch) 60 BB Left side Right side -3 2 hole (For suspension bolt) AA 62 * In case of right side connection. ** Including the protection tubes when connecting to the left side. 5

K (SUCTION) L (DISCHARGE) M (LIQUID) N P Type 56 Type 656 Type 856 Type 60 Unit : mm 27 38 37 37 38 27 Suction tube ID K Liquid tube ID M Discharge tube ID L VIEW AA Suction tube ID K Liquid tube ID M Discharge tube ID L 200 5 VIEW BB Liquid tube ID N Gas tube ID P How to use the fittings. Check the suspension bolt pitch. 2. Ensure that the ceiling is strong enough to support the weight of the unit. 3. To prevent the unit from dropping, firmly fasten the suspension bolts as shown in the figure below. Hole-in-anchor Hole-in-plug Insert Nut (field supply) Washer (field supply) Concrete L* 20 50 Washer (field supply) Nut (field supply) Suspension bolt (field supply) Nut (field supply) Washer (supplied) Suspension bolt (field supply) Suspension lug * Choose L dimension according to the status of the ceiling. Suspension bolt (3/8" or M0) (field supply) Nut (field supply) (3/8" or M0) Washer (supplied) - POSITION CAUTION Wrong positioning will become unfitted center of gravity position, causing injuries or product damage. 6

. Wiring, Tubing and Heat Insulation -. Refrigerant tubing Remove the protection tubes before connection. Cool the tubes with damp cloth or other means Remove the protection tubes when connecting to the left side. Liquid tube Gas tube Cool the tubes with damp cloth or other means when brazing the joint with a torch. Otherwise, the solenoid valve will be damaged. Cool even when removing protection tubes. Cool with damp cloth or other means when brazing the joint with a torch. Otherwise, the solenoid valve will be damaged. (Only in the case of left side connection) Suction tube Discharge tube Liquid tube * In the case of left side connection, remove the left side protection tubes and install supplied protection tubes (3 types) on the right side(brazing connection). NOTE When brazing, be sure to perform nitrogen replacement inside the tube so that oxidation coating does not form inside the tube. Then stop performing when nitrogen replacement is completed. The solenoid valve, however, will be damaged if nitrogen is applied while brazing. Heat sensitive components, protect from flame and heat conduction. Comply with all Local Code Requirements. Branch piping from each port has to be in a position with 5~30 upward by 200mm or more. (same manner as normal branch piping) Branch piping from each port has to be in a position with 5~30 upward by 200mm or more. (same manner as normal branch piping) -2. Heat Insulation Be sure to insulate the tubing after finishing leakage inspection. Wrap insulators (field supplied) with the heat resistance of 20 C or more around the discharge tubes and gas tubes, and 80 C or more around the suction tubes and liquid tubes. Wrap around the each tube not to make gaps between the thermal insulation. Failure to conduct shielding gaps and thermal insulation will cause water leakage. Insulate the protection tubes of outdoor unit side and indoor unit side. 7

5. ELECTRICAL WIRING 5-. General Precautions on Wiring () Before wiring, confirm the rated voltage of the unit as shown on its nameplate, then carry out the wiring closely following the wiring diagram. (2) Each wiring connection must be done in accordance with the wiring system diagram. Wrong wiring may cause the unit to misoperate or become damaged. (3) Do not allow wiring to touch the refrigerant tubing. () Unauthorized changes in the internal wiring can be very dangerous. The manufacturer will accept no responsibility for any damage or misoperation that occurs as a result of such unauthorized changes. (5) Regulations on wire diameters differ from locality to locality. For field wiring rules, please refer to your LOCAL ELECTRICAL CODES before beginning. You must ensure that installation complies with all relevant rules and regulations. (6) If the power supply cord of this appliance is damaged, it must be replaced by a repair shop designated by the manufacturer, because special-purpose tools are required. WARNING This equipment is strongly recommended to be installed with Earth Leakage Circuit Breaker (ELCB) or Residual Current Device (RCD). Otherwise, it may cause electrical shock and fire in case of equipment breakdown or insulation breakdown. Earth Leakage Circuit Breaker (ELCB) must be incorporated in the fixed wiring in accordance with the wiring regulations. The Earth Leakage Circuit Breaker (ELCB) must be an approved 0-6 A, having a contact separation in all poles. To prevent possible hazards from insulation failure, the unit must be grounded. 5-2. Recommended Wire Length and Wire Diameter for Power Supply System Table.5- Solenoid valve kit Type 56 656 856 60 Table.5-2 Control wiring Type 56 656 856 60 Power supply Time delay fuse or 2.5 mm 2 circuit capacity Max. 30m Inter-unit (between relay kit and solenold valve kit) control wiring 0.75 mm 2 (AWG #8) Max. 30m 0-6 A CAUTION Use the standard power supply cables for Europe (such as H05RN-F or H07RN-F which conform to CENELEC (HAR) rating specifications) or use the cables based on IEC standard. (6025 IEC57, 6025 IEC66) 8

5-3. Wiring System Diagram unit Electrical box Control board (Main) Connect to 3way 3WAY (BLK) 5P Solenoid valve relay kit Control board (CR-SV80A-N) Ferrite core OPTION / 3WAY (WHT) 6P 2 3 5 Power supply 220/230/20V~50Hz 220/230V~60Hz L N Control wire(5 wires) field supplied (Max. 30m) Field supplied Ground Terminal board Terminal board 3-Way connecting wire (.9m) / supplied Terminal board Solenoid valve kit L N 2 3 5 For relay kit unit (N) Electrical box Control board (Main) Connect to 3way 3WAY (BLK) 5P Solenoid valve relay kit (N) Control board (CR-SV80A-N) Ferrite core OPTION / 3WAY (WHT) 6P 2 3 5 Control wire(5 wires) field supplied (Max. 30m) Terminal board Terminal board 3-Way connecting wire (.9m) / supplied 2 3 5 For relay kit (N) (N) :, 6, 8 Fig. 5-3 Label of (indoor unit piping connection side) Label of (connection terminal side) Connect the wiring to match the numbers of indoor unit connection piping side and communication terminal side. 9

5-. Procedure. Connect the power supply wire to the, using the wire shown in Table 5-. (Fig. 5-5) 2. Connect the to the solenoid valve relay kit, using the wire shown in Table 5-2. (Fig. 5-, Fig. 5-5) 3. Connect the solenoid valve relay kit to the indoor unit, using the supplied connecting wire. (Fig. 5-3, Fig. 5-). The left-over wires connected to the solenoid valve relay kit should be tied up in a bundle of wires by the supplied wire holder not to leave the wires loose as shown in the diagram at right. (Fig. 5-) Ground Solenoid valve kit Solenoid valve relay kit 3-Way connect wire (supplied) Control wire (field supplied) * Wiring fixed with clamper Power supply (field supplied) * Wiring fixed with clamper Fig. 5-5 Control wire (field supplied) Clamper (Supplied) Fig. 5- * Wiring fixed with clamper How to connect wiring to the terminal For stranded wiring () Cut the wire end with cutting pliers, then strip the insulation to expose the stranded wiring about 0 mm and tightly twist the wire ends. (Fig. 5-6) (2) Using a Phillips head screwdriver, remove the terminal screw(s) on the terminal board. (3) Using a ring connector fastener or pliers, securely clamp each stripped wire end with a ring pressure terminal. () Place the ring pressure terminal, and replace and tighten the removed terminal screw using a screwdriver. (Fig. 5-7) Wire Clamper Stranded wire Special washer Screw Strip 0 mm Ring pressure terminal Wire Ring pressure terminal Terminal board Screw and Special washer Ring pressure terminal Fig. 5-6 Fig. 5-7 Wire CAUTION Loose wiring may cause the terminal to overheat or result in unit malfunction. A fire hazard may also occur. Therefore, ensure that all wiring is tightly connected. 5-5. Installation to the Solenoid Valve Relay Kit Install the solenoid valve relay kit into the indoor unit and fix it using a Philips-head screwdriver. See the diagram in the section of "7. Installation Diagrams of the Solenoid Valve Relay Kit". WARNING Do not install outside the building and the area where the water is splashed. Failure to do so could result in product or property damage. Do not handle or touch the unit with wet hands. Failure to do so could result in electric shock. 0

6. Piping system design limitation 6-. Design limitations overview Type Limitations Remarks Connectable capacity (kw) 56 Type 60 Type 5.6 6.0 It is possible that 2 ports is used in parallel. Refer to "6-5. 2 ports to be used in parallel". Distance from unit * Installation place Branch to several indoor unit under port (Same mode operation) Individual ON/OFF control under port Within 30m from unit Corridor : Strongly recommended Room : Avoid Possible up to 2 indoor units Possible Distance between distribution joint and I/U is within 50m. Need Initial setting by PC software * If the distance between distribution joint and indoor unit (L) is more than 30m, for the pipe between distribution joint and (La), and for the pipe between and indoor unit (Lb), increase the piping size by rank. Refer to the installation instruction of outdoor unit for the piping size. La L 50m Lb 30m NOTE The following chart shows that the total capacity of combined indoor units connected from the solenoid valve kit includes the further indoor unit connected to the Single or. Type 56 656 856 60 Total allowable capacity (kw) 25.0 36. 7.6 70.0 Pinch sealing 2 3 N- N 2 3 5 6 N- N ex)total allowable capacity=total capacity of indoor -indoor N

6-2. Series connection by 2 The length between the s shall be within 200mm. (Refer right table for detail about 2 box combination.) within 200mm 2 Available combination First box port (56 type) 6 port (656 type) port (60 type) 2 Second box port (56 type) 6 port (656 type) port (60 type) port (56 type) port (60 type) port (56 type) 6 port (656 type) port (60 type) OK/NG The piping of indoor unit side is possible to connect in the opposite direction as shown in the below figure. 2 within 200mm NOTE Piping between the s, maintain straight line, and use the same size piping as 2 Second box. Direct connection of indoor unit just after the s is disapproved 2

6-3. Connection with Distribution Joint after the distribution joint kit is possible. before the distribution joint is disapproved 6-. Connection with T-branch (field supplied) T-branch after is possible * Connectable total indoor unit capacity after is limited. * Piping length "a" shall conform to the below table. Limitation of piping length (a) Type 56 656 856 60 a (mm) 00 700 300 00 T-branch a Pinch sealing NOTE From pinch sealing to, keep the pipe in a straight line. T-branch before is possible. T-branch a NOTE From end of T-branch to, keep the pipe in a straight line. 3

6-5. 2 ports to be used in parallel 2 ports to be used in parallel for the unit 80/22/280 type Use 60 type. 2 ports to be used in parallel for the unit 60-0 type Use 856 type, 656 type and 56 type. Use distribution joint to unite 2 outlet ports to port. Distribution joint Use Relay kit on indoor unit. Pass the control line between 2 ports on. 3way PCB control line Relay kit unit Power supply Power supply Power line 3way PCB 3way PCB 3way PCB control line control line To other indoor unit 6-6. Connection with Distribution Joint before the distribution joint is disapproved Use distribution joint to divide outlet port to 2 ports. (T-joint is not allowed.) unit type shall be the same. Ex.) way + way=ok, Wall +Wall =OK, but, way + Wall = NG. Capacity of each indoor unit shall be the same, and the total indoor unit capacity under port shall not exceed than allowable max capacity of the port. Ex.) In case of 656 type box, allowable max capacity of the port is 5.6 kw or less. 2.8kW+2.8kW= OK, 3.6kW+3.6kW=NG, 3.6kW+2.2kW=NG. Piping length from to each indoor unit shall be within 30 m. Difference of piping length between 2 distribution joints shall be within 5m. ( (a-b) 5m ) No height difference between indoor units. Relay kit may be connected to either one of the indoor unit. within 30 Distribution joint b a Same type Same capacity Same height

6-7. Single Floor Building Layout after the distribution joint is possible. 50mm 50mm La= Farthest indoor unit LbClosest unit La-Lb 50m 6-8. Multi Floor Building Layout It is possible in terms of layout, however, be sure piping diameter/piping length, including the indoor units are within the allowance. 6-9. unit control method These control methods are possible. Distribution joint (*) Distribution joint (*) Main Sub Normal control Group control by Main (+Sub) remo-con Simultaneous operation under port (normal group control) Individual operation under port (Necessary special setting at initial set-up for all indoor unit by PC.) 5

7. Installation Diagrams of the Solenoid Valve Relay Kit Make sure that the power supply wiring, communication wiring and 3-way wiring will not be crossed each other. U Type Y2 Type Solenoid valve relay kit Solenoid valve relay kit D Type Solenoid valve relay kit 6

F2 Type AIR INTAKE SIDE Solenoid valve relay kit AIR INTAKE SIDE K Type K2 Type L Type M Type E Type E2 Type P Type R Type W Type H Type Z Type Install the solenoid valve relay kit on the wall. Important: Installation behind the wall or ceiling is required that the maintenance should become capable. Solenoid valve relay kit 7

T2 Type Solenoid valve relay kit Cut out the hole and lead the cable of the through the hole. Remove the burr around a rim of the punched hole to prevent damage to the cable. Seal or apply putty around the opening to maintain airtightness. Solenoid valve cable Fan motor wiring Solenoid valve relay kit Be careful not to contact between the solenoid valve cable and fan motor wiring. Tie the solenoid valve cable through the band. View of unit inside 8

M E M O 9

Panasonic Corporation 006 Kadoma, Kadoma City, Osaka, Japan Authorised representative in EU Panasonic Testing Centre Panasonic Marketing Europe GmbH Winsbergring 5. 22525 Hamburg, Germany 856369862000 Printed in Japan