Specifications Occupancy/Vacancy Sensors CSI ASHRAE AIA Division 16 Section 16950

Similar documents
Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

Product Specifications Dialog Room Controller* (*patent pending)

Dual Technology Wall Switch Occupancy Sensor. Manual & Specification

2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T F E. cristalcontrols.

Occupancy and Vacancy Sensors

Mini Product Guide.

Table of Contents Dialog Panel Based System Dialog Room Controller

LS-CM Series. Overview. Applications. Features & Benefits. Datasheet. Ceiling mount occupancy sensors

Sensors and Detectors

East Central College

Ceiling Mount Sensors B4-B9. Occupancy and Vacancy Sensors B10-B15 B16-B17. Wall Mount Occupancy Sensors B-1

DIVISION 26 ELECTRICAL SECTION LIGHTING CONTROL SYSTEM

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor

v3 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On feature

SECTION 26 NX DISTRIBUTED INTELLIGENCE LIGHTING CONTROL SYSTEM HUBBELL CONTROL SOLUTIONS

SECTION LIGHTING CONTROL DEVICES EATON S LIGHTING SYSTEMS (FORMERLY COOPER CONTROLS) VACANCY/OCCUPANCY SENSORS

Applied Lighting Controls

Installation Instructions

Versatile wall switch sensors maximize payback and simplify code compliance

PSC-BL-I-FM-DC0(-BLE) Bi-level Dimming PIR Sensor

A. This Section includes the following lighting control devices:

A. This Section includes the following lighting control devices:

Lighting Control Solutions for Parking Facilities

LIGHTING CONTROL DEVICES

Lighting Control Strategies. to meet code requirements save energy and improve building performance

SECTION LIGHTING CONTROL DEVICES

Ceiling-Mounted Motion Detector. 752/CD, 752/CP, 752/CU and 752/Cx180. Installation Instructions

SECTION LIGHTING CONTROLS

CONTENTS SENSOR SWITCH

Dual Relay Multi-Technology Wall Switch Occupancy Sensors

IN2 Lighting Control Devices

ADDENDUM NO. 2 COOK LIBRARY BATHROOM RENOVATIONS PROJECT NUMBER TU-1874-SBR

Maestro 0 10 V Dimmer Sensor

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

SECTION LIGHTING CONTROL DEVICES AND CONTROL PANELS

Tualatin Valley Fire & Rescue Finance Department SW 70 th Ave., Tigard, OR Phone: , Fax:

SENSORS. Vacancy Sensors. Occupancy Sensors A4-A7 A-1

T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability

Infrared Ceiling Mount Sensor

Ceiling-Mounted Wireless Occupancy/Vacancy Sensor

LIGHTING CONTROLS

64.7 Ø85. (1) Sensor inset (2) Lens pluggable. (3) Protection cover (covers the high-voltage terminals). (4) Ceiling (drill hole Ø70mm).

Lighting Controls. Energy-Saving Solutions For Efficient Buildings

1. Division 26 Section Electrical General Requirements. 2. Division 26 Section "Wiring Devices" for wall-box dimmers and manual light switches.

Arrow Hart. Universal Dimmers and Sensors. Eaton s Arrow Hart. Reliable lighting control for commercial installations

, ,

Arrow Hart. Universal Dimmers and Sensors. Eaton s Arrow Hart. Reliable lighting control for commercial installations

A. Furnish and install wiring devices and plates as specified herein and as shown on the Drawings.

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL

Sensors Explained AUTOMATION

Table of Contents. Fast Fact. Sensor Models 2 Advantages of Sensors 3 FAQs 4-5

HUNTERSVILLE, NORTH CAROLINA USA EFFECTIVE SEPTEMBER 1, 2004

Wireless Wall-Mount Sensor

National Grid Small Business Program Rebate Manual

Technology. Occupancy & Vacancy Sensors & Timers. Technology. Occupancy & Vacancy Sensors & Timers L-2

Integrated PIR detectors

Infrared Wall Mount Occupancy Sensor

Princeton Joint Unified School District Invitation for Bid Installation of District-Wide Lighting Occupancy Sensors

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

SECTION DIGITAL-NETWORKING LIGHTING CONTROLS ENLIGHTED LIGHT MANAGEMENT SYSTEM

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor.

Wireless Plug Load Control

Ceiling PIR HS presence detector. Product Guide. Overview. Features

C. The system shall be capable of turning luminaires on/off (where supported by the luminaire) as well as full range dimming.

Never forget to turn the lights off again. Motion Sensors

DS160/DS161 Request To Exit PIR sensors Installation Instructions

VITMR-EBDSPIR-PRM. PIR Presence/Absence Detector IR with Ceiling Rose. Product Guide. Overview. Features

EBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features

Wherever the best is needed. Sensors for professionals.

Product Guide. Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

UBC Technical Guidelines Section Edition Interior Building Lighting Page 1 of 5

Retrofit Solutions NEW. Energy-saving products for single rooms. Lutron energy-saving products. Patient Rooms. Office Spaces. Affordable Solutions

Infrared Ceiling Mount Sensor

TOCR02 2 PART MICRO MOTION SENSOR W/IR REMOTE CONTROLLER

Product Guide. Ceiling PIR HS presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

CS1200 WHT Pir Ceiling Mount Occupancy Sensor

Vive PowPak Fixture Controls

FCSENS0R Occupancy Sensor. Long Description. Manufacturer Information. Taxonomies, Classifications, and Categories

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Instructions PRODUCT RANGE NEWLEC DALI OCCUPANCY DETECTOR PART NUMBER NL5701DALI

English. Italiano. Português. Françias. Español

Pre-March 2016 Design - Click to be redirected to newer SBS-H2 design SBS-H2. Hydrogen Gas Detector Kit

Conventional Smoke Detectors KFAPO

Welcome. Sensor. 1 (844) LIGHTCLOUD Custom manufactured in China RAB Lighting, Inc 170 Ludlow Avenue Northvale, NJ 07647

RDM LOCK G Series Electromagnetic Lock. Listings. Standard Features. Ordering Information:

Reduce lighting energy costs with controls

DS160/161 Request To Exit PIR sensors Installation Instructions

Wireless Occupancy Sensor, Wall Mount with Photosensor (WOS2-WM)

180 Degree Ceiling Mounted Occupancy Sensors

VESICA LINEAR SUSPENDED VES L

ENERGY EFFICIENCY EXPERTS

Ever evolving energy code requirements and the large demand for energy

GE LightSweep Lighting Control System Guideform Specification

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

WVU DESIGN GUIDELINES & CONSTRUCTION STANDARDS DIVISION 26 ELECTRICAL

Douglas Lighting Controls. Bluetooth Fixture Controller & Sensor. Installation Manual BT-FMS-A. *Patent Pending. Installation Guide BT-FMS-A v7

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

PIR OnOff Page 2-3 PIR & Radar MinMaxOff Page 3-8. Sensor Manual LedgeCircle

Transcription:

1 Specifications Occupancy/Vacancy Sensors CSI 26.09.23. ASHRAE 90.1-2010 AIA Division 16 Section 16950 1. PART 1 - General 1.1 Overview 1.1.1 Provide Occupancy/Vacancy sensors as shown on the plans and specified herein. The sensors shall sense human activity in the space and provide ON/OFF and/or dimming control based on Occupancy/Vacancy. 1.1.2 If Natural Daylight is required, the Occupancy/Vacancy sensor shall have a Photo Sensor incorporated into the device. 1.1.3 The Occupancy/Vacancy sensing technologies shall not emit radiation that can interfere with the operation of any electronic devices. 1.1.4 The acceptable dual technology sensing shall be passive infrared (PIR) and acoustic voice detection using Accurate Detection Intelligence (ADI-Voice) technology. 1.1.5 The acceptable single technology sensing shall be passive infrared (PIR) technology. 1.1.6 Dual technology sensors shall have 2 programming methods: 1.1.6..1. Each sensor shall provide manual configuration capabilities of standard parameters without requiring special tools. 1.1.6..2. Each sensor shall allow for programming though the use of an Infrared Setting Unit (Douglas Lighting Controls part # WIR- 3110) ; eliminating the need to directly access the device for additional configuration. 1.1.7 Single technology sensors shall have 1 programming method: 1.1.7..1. Each sensor shall provide manual configuration capabilities of standard parameters without requiring special tools. 1.1.8 It shall be possible to manually set the Time Delay and Sensitivity levels to match specific requirements or the sensor can be set to automatically activate a selfadapting algorithm to maximize energy savings based on occupancy/vacancy tendencies. 1.1.9 The installing contractor shall adhere to the manufacturer s recommendations for sensor location. 1.1.10 The installing contractor shall set the Time Delay and Sensitivity as per owner s instructions. 1.1.11 The installing contractor shall be responsible for adhering to all applicable codes and for providing a completely functional system.

2 1.2 Manufacturers 1.2.1 Subject to compliance requirements, Douglas Lighting Controls products shall be used. 1.2.2 Subject to compliance requirements, Diversa Occupancy/Vacancy sensors by Douglas Lighting Controls shall be used. 1.3 Prior Approval Submissions 1.3.1 Manufacturer wishing to submit quotations on the Occupancy/Vacancy sensors must meet prequalification requirements. Prequalification information must be submitted to the electrical consulting engineer not less than ten (10) working days prior to the final closing of tenders for this project. 1.3.2 Manufacturer must be prepared to demonstrate the equipment being proposed before the closing of tender. 1.3.3 Manufacturer must submit coverage patterns of the proposed system for review. 1.4 Instruction Manuals 1.4.1 Manuals for system components must be supplied to permit ease of installation, system operation, and maintenance including, but not limited to, the following: Occupancy/Vacancy Sensor step-by-step operating instructions Detailed programming instructions for all configuration parameters. 2. PART 2 - Materials 2.1 Wall Switch Sensor Line Voltage WOS Series 2.1.1 Sensors shall be Diversa WOS series Dual Technology with ADI-Voice detection 2.1.2 Sensors shall be Diversa WOS series PIR Technology 2.1.3 Sensors shall mount in a standard Decora style switch plate and shall mount recessed into the applicable gang box. 2.1.4 Sensors shall have a 180 degree coverage pattern. 2.1.5 Sensors shall provide an adjustable timeout period of 30 seconds to 30 minutes. 2.1.6 There shall be no leakage current to the load when the sensor is in the OFF position. 2.1.7 If a Photo Sensor is required, it shall be incorporated into the Occupancy/Vacancy 2.1.8 A Manual Override Switch is to be provided on the sensor to allow the sensor to switch loads ON by the switch and OFF by the sensor. 2.1.9 If required by the plans, a Diversa WVS series Vacancy Sensor shall be provided. This detector shall not be reconfigurable to be an Occupancy/Vacancy Sensor by the user. 2.1.10 Where 2 level switching is required, a 2-pole sensor shall be provided. The sensors

3 2.2 Wall Switch Sensor Low Voltage WOS Series 2.2.1 Sensors shall be Diversa WOS series Dual Technology with ADI-Voice detection 2.2.2 Sensors shall be Diversa WOS series PIR Technology 2.2.3 Sensors shall mount in a standard Decora style switch plate and shall mount recessed into the applicable gang box. 2.2.4 Sensor shall have a 180 degree coverage pattern. 2.2.5 Sensors shall provide an adjustable timeout period of 30 seconds to 30 minutes. 2.2.6 Sensors shall operate with the Diversa WP-PP20-D / WP-PP20-2P-D / WP-PP20-347-D Power Pack using diode pulse technology. 2.2.7 If required, multiple sensors may be linked together on a single Power Pack and be configured so that all sensors in a single space can act together as one zone. 2.2.8 A Douglas Lighting Controls WR-4075 transformer shall be used if required. 2.2.1 If a Photo Sensor is required, it shall be incorporated into the Occupancy/Vacancy 2.2.2 A Manual Override Switch is to be provided on the sensor to allow the sensor to switch loads ON by the switch and OFF by the sensor. 2.2.3 Where 2 level switching is required, a 2-pole sensor shall be provided. The sensors 2.2.4 Provide as required on the plans, options that are available from the following list: 0-10VDC outputs for dimming ballast option for Natural Daylight with user settable light levels. Configurable high and low light level set points so that the sensor can toggle between light levels upon Occupancy/Vacancy. Auxiliary relay, for signaling other systems, which can be configured so that it synchronizes with the ON/OFF status of the load or the status of Occupancy/Vacancy. Remote Manual Override Switch, Douglas Lighting Controls WR-86xx series switch 2.3 Ceiling Sensor Line Voltage WOR Series 2.3.1 Sensors shall be Diversa WOR series Dual Technology with ADI-Voice detection. 2.3.2 Sensors shall be Diversa WOR series PIR Technology 2.3.3 Ceiling sensors shall mount recessed in to the ceiling space. 2.3.4 Sensors shall have a 360 degree coverage pattern with an adjustable swivel head to maximize coverage area when mounted on sloped ceilings. 2.3.5 Sensors shall provide an adjustable time out period of 30 seconds to 30 minutes. 2.3.1 If a Photo Sensor is required, it shall be incorporated into the Occupancy/Vacancy 2.3.2 A Manual Override Switch is to be provided on the sensor to allow the load to be manually switched ON and OFF for the purpose of testing during installation. 2.3.3 Where 2 level switching is required, a 2-pole sensor shall be provided. The sensors

4 2.4 Ceiling Sensor Low Voltage WOR Series 2.4.1 Sensors shall be Diversa WOR series Dual Technology with ADI-Voice detection. 2.4.2 Sensors shall be Diversa WOR series PIR Technology 2.4.3 Ceiling sensors shall mount recessed in to the ceiling space. 2.4.4 Sensors shall have a 360 degree coverage pattern with an adjustable swivel head to maximize coverage area when mounted on sloped ceilings. 2.4.5 Sensors shall provide an adjustable time out period of 30 seconds to 30 minutes. 2.4.6 Sensors shall operate with the Diversa WP-PP20-D / WP-PP20-2P-D / WP-PP20-347-D Power Pack using diode pulse technology. 2.4.7 A Douglas Lighting Controls WR-4075 transformer shall be used if required. 2.4.1 If a Photo Sensor is required, it shall be incorporated into the Occupancy/Vacancy 2.4.2 A Manual Override Switch is to be provided on the sensor to allow the load to be manually switched ON and OFF for the purpose of testing during installation. 2.4.3 Where 2 level switching is required, a 2-pole sensor shall be provided. The sensors 2.4.4 Provide as required on the plans, options that are available from the following list: 0-10VDC outputs for dimming ballast option for Natural Daylight with user settable light levels Configurable high and low light level set points so that the sensor can toggle between light levels upon Occupancy/Vacancy Auxiliary relay, for signaling other systems, which can be configured so that it synchronizes with the ON/OFF status of the load or the status of Occupancy/Vacancy Remote Manual Override Switch, Douglas Lighting Controls WR-86xx series switch 2.5 Corner Mount Sensor Low Voltage WOW series 2.5.1 Sensors shall be Diversa WOW series Dual Technology with ADI-Voice detection 2.5.2 Corner Mount Sensors shall connect to a mounting bracket designed to allow 45 degree movement in both the horizontal and vertical directions. 2.5.3 Sensors shall have a 90 degree coverage area for corner mount applications and 130 degree coverage area for large area applications. 2.5.4 Sensors shall provide an adjustable time out period of 30 seconds to 30 minutes. 2.5.5 Sensors shall operate with the Diversa WP-PP20-D / WP-PP20-2P-D / WP-PP20-347-D Power Pack using diode pulse technology. 2.5.6 A Douglas Lighting Controls WR-4075 transformer shall be used if required. 2.5.1 If a Photo Sensor is required, it shall be incorporated into the Occupancy/Vacancy 2.5.2 A Manual Override Switch is to be provided on the sensor to allow the load to be manually switched ON and OFF for the purpose of testing during installation.

5 2.5.3 Where 2 level switching is required, a 2-pole sensor shall be provided. The sensors 2.5.4 Provide as required on the plans, options that are available from the following list: 0-10VDC outputs for dimming ballast option for Natural Daylight with user settable light levels Configurable high and low light level set points so that the sensor can toggle between light levels upon Occupancy/Vacancy Auxiliary relay, for signaling other systems, which can be configured so that it synchronizes with the ON/OFF status of the load or the status of occupancy/vacancy Remote Manual Override Switch, Douglas Lighting Controls WR-86xx series switch 2.6 Infrared Setting Unit - WIR-3110 2.6.1 Provide a Douglas Lighting Controls WIR-3110 Infrared Setting Unit to facilitate the following functions: Set switch type and address Configure device presets Calibrate Photo Sensors, set addresses, set light levels Set address of Occupancy/Vacancy Sensors 2.7 Low Voltage Power Packs WP-PP20 series 2.7.1 Where indicated on the plans, provide Douglas Lighting Controls WP series Power Packs capable of powering multiple sensors. The Power Pack shall be controlled by a diode pulse provided by a switch (Douglas Lighting Controls WR-86xx Series) or Occupancy/Vacancy Sensor. 2.7.2 Power Packs shall provide up to a maximum of 150mA at 24VAC to the low voltage Occupancy/Vacancy Sensors. 2.7.3 Power Packs shall be offered in single pole, 2-pole and 347VAC configurations. 3. PART 3 Installation 3.1 Occupancy/Vacancy Sensors 3.1.1 Locate sensors so there are no objects blocking the infrared sensor from viewing all of the coverage area. Keep away from HVAC vents, direct sunlight and direct light from light fixtures. 3.1.2 Adhere to manufacturer s recommendations for location, coverage area, wiring and programming. 3.2 Power Packs 3.2.1 Mount Power Packs into a 4 inch junction box through a ½ inch conduit opening. 3.3 Low Voltage Wiring 3.3.1 Low voltage wiring shall be #18 AWG LVT wire type or equivalent.

6 3.4 Line Voltage Wiring 3.4.1 Pigtail leads from sensors are #14AWG. Use appropriately sized wire for the branch circuit. 3.4.2 Make appropriate grounding connections to the Wall Switch sensors. - ### -