Content Index 1 General information 4

Similar documents
ADDITIONAL FUEL STORAGE CONTROLLER MP-01

BOILER CONTROLLER COMPACT

System. For a better understanding of this product, please read this user manual thoroughly before using it.

MOBILE CALL GSM Alarm System User s Manual

Installation instructions. For the competent person. Installation instructions VRT 350 VRT 350 GB, IE

Mobeye CM2410 GSM fire alarm communicator

GSM Alarm System. User s Manual. Profile. MOBILE CALL GSM Alarm System

USER MANUAL Mobeye ThermoGuard CM2200

GSM RFID VOICE Alarm System

Monitoring Solutions

V1.0. Smart Home Alarm System. User Manual. APP download via QR Code scanning. Please read the manual carefully before using.

Profile. For a better understanding of this product, please read this user manual thoroughly before using it.

USER S MANUAL. Profile. MOBILE CALL GSM Alarm System

To activate using remote control: press [ ] key once. To activate using keyboard: on panel keyboard [ ] keys once.

Intelligent Wireless GSM Alarm System

Climapro 2. User manual. wireless room thermostat without receiver. To be left with the user.

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE

Halton SAFE / 7.14 user guide and installation instructions

EZY SWITCH. SMS-IRR-4 System Monitor Installation Manual

Elderly Care Alarm System

Remote switching machines with a SMS text from your mobile phone! Remote Monitoring your assets in the worldwide by your mobile Phone!

EM8710 GSM Alarm System Starter Kit

SMS GSM Alarm Messenger

Kwêbeam GSM/Interface/Repeater Module

Ion Gateway Cellular Gateway and Wireless Sensors

Intellicomfort CH140GSM

DOCUMENTATION IPS640

SC-F3G User Manual 1.0

PORTAL USER MANUAL. Mobeye WaterGuard-FS. Float sensor CM2300FS. SW version 5.n

DOCUMENTATION IPS640

NEW LINE BOILER CONTROLLERS

Use of the application program

GSM WIRELESS ALARM SYSTEM Model: GSM-0308W

DC Voltage Sensor. Specifications Didactum DC sensor: The sensor is automatically detected by the Didactum base unit. Accuracy: 1%

S3 Sim Secual Alarm system with GSM transmitter

2G & 3G GSM Wireless Beam Alarm

Products no longer available

USER S MANUAL HOME ENERGY SAVINGS REMOTE CAMERA INTERNET USER INTERFACE TEMPERATURE ALARMS BURGLARY PROTECTION DOOR SECURITY FIRE SAFETY

INSTRUCTION FOR THE USER THC V E OIL BLU

Operating instructions

Passive infrared ceiling sensor

Operating Guide. Termix Solar A+/B+ 1.0 Table of Contents. 1.0 Table of Contents

1 DOCUMENT REVISION SOFTWARE VERSION BASIC DESCRIPTION BASIC OVERVIEW OF HYDRAULIC DIAGRAMS HYDRAULIC DIAGRAMS...

Typical applications include the vibration detector. Detection of vibrations and shocks

2G & 3G GSM Door Contact Alarm


Application description

User reference guide. Daikin Altherma Low temperature split EHBH04CB EHBH08CB EHBH11CB EHBH16CB EHBX04CB EHBX08CB EHBX11CB EHBX16CB

3G GSM AUTO DIALER. Remote monitoring & Control using your mobile phone. MODEL NUMBER 3GAD1

Operating instructions

1. Functions of GPS locator ETLOC-30S 3

INSTALLATION and OPERATING INSTRUCTIONS ARITERM GSM A2

Smoke Detector and Siren. Manual

No. Icon Name Function

Fitting instructions

CAN unit for Analog Sensors

GSM 3G AUTO DIALLER. Remote monitoring & Control using your mobile phone. MODEL NUMBER 3GAD1

Diplomat Inverter/Diplomat Duo Inverter

Installation and Operating Manual

With Magictrl, you can control MatiGard anytime & anywhere via your smartphone, even without data network.

OPERATING INSTRUCTIONS

LevelSET S GSM Functionalities Instructions for Commissioning and Use

Installer Manual KNX Touchscreen Thermostat

PROGRAMMABLE 7-DAY RF THERMOSTAT

GSM Smart Home Alarm Apparatus. [99+4 defense zones] Instruction for Use

DESCRIPTION OF KEYPAD (Access module with segments)

Outdoor Temperature Sensor

GSM House Alarm System. User Manual. Ver 1.20 Date Issued:

WiFi GSM APP Smart Home Security System

WATER HEATER ELECTRONIC CONTROLLER USER MANUAL

SMART HOME SECURITY. Dual Network Communicating Alarm System with RFID INVINCIBLE. Instruction Manual. Customer Helpline

The MCD-111 AUTOKLAW Microprocessor Controller Version 1.00 User s Manual

90cm Tower Fan. Model Number SFTF36B-LED AFTER SALES SUPPORT AUS

Contents. Glossary

PRODUCT CATALOG INSTALLATION CONTROLLERS ROOM REGULATORS ZONE HEATING CONTROL FLOOR HEATING CONTROL BOILER CONTROLLERS SOLAR SYSTEMS CONTROLLERS

Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual

Fig.: A fire in a server room or data center may cause devastating damage. Protect your infrastructure.

AirFlow Sensor for Dry Contact connection

G4S SMARTalarm User Guide

VDC. Wireless AC Voltage Detection Sensor. The Leader in Low-Cost, Remote Monitoring Solutions. General Description. Monnit Sensor Core Specifications

POP_ Smoke Detector

User instructions DHP-AT

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

USER MANUAL S203. Controller for three circuits. - control for 2 heating circuits - 1 domestic hot water control. Saving energy, creating comfort

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock.

Blueair Pro User Manual

SMART SWITCH TECHNOLOGIES. SmartSwitch Yacht-Guard Model SMS-8 Vessel System Monitor Installation Manual

Combined CAN Sensor Unit Temperature, Humidity and Smoke

Climapro 2. Installation. wireless room thermostat without receiver.

Data sheet. Function description. Benefits

Ontech GSM 9040/50. Reference Manual English -1 -

ThermoControl 0 C - 10 C - 20 C - 30 C

PROGRAMMABLE 7-DAY THERMOSTAT

QAW70. Room Unit. Building Technologies. for use with heating controllers

Porsche Classic Vehicle Tracking System FAQs

La Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual

Wolf Guard Touch Keypad GSM Wireless alarm system User s Manual

POP_ Smoke Detector

Technical Manual MDT Motion Detector

DOL 31 Speed Controller Technical User Guide

Transcription:

page 2

Content Index 1 General information 4 1.1 Introduction 4 1.2 Elements of the set 4 1.3 Precautions 5 1.4 Procedure with the used equipment 6 2 Connection 6 2.1 Electrical wiring 6 2.2 Location 7 condensation. 7 2.3 Installation 7 2.4 Description of connections 8 3 Review of functions 9 3.1 Control of binary output 9 3.2 Information about input condition 9 3.3 Information about the controller of boiler 10 3.3.1 Commands of queries about the parameters of boiler controller...10 4 Main display 12 5 Main menu 13 5.1 Sensors 13 5.2 Binary output 14 5.3 GSM settings 15 5.4 Settings 15 5.5 Notices 15 5.6 Language 16 5.7 Remote control panel 16 6 Specification 17 estyma electronics www.estyma.pl page 3

1 General information 1 General information Than you for choosing our product. We congratulate you on making a good decision. We welcome any remarks on the operation of device. Team ESTYMA electronics 1.1 Introduction VIDE GSM communication module is a multifunctional device designed for remote access to the information of module sensors and controller of hot water boiler by means of GSM network. The module is equipped with two slots of temperature sensors, two slots for contact input and output and CAN interface. Configuration, user-friendly panel makes it possible to set SMS notices about important changes in the operation of sensors, such as: exceeding the range of room temperature allowed alarm when the input contact is closed or open, used for giving notice about the opening/shutting of doors, gates, garages. Contact output (binary), makes the remote activation/disconnection of any electrical equipment possible. Using mobile, you can also read out current parameters of module as well as make chnages in settings. By means of CAN interface, the Vide GSM module can remotely control the operation of heating controller of IGNEO line, and make changes in the operation modes of boiler, burner and 16 central heating circuits at most. The GSM communication system makes it possible to make several changes in the controller operation and to read out current parameters displayed on your mobile by sending SMS. 1.2 Elements of the set 1. Vide GSM module 2. 2x sensor of room temperature CT2a / 2.4 3. Power unit page 4

Content 1.3 Precautions Before you start to operate the device, read the whole attached user`s guide carefully. Keep the user`s guide and refer to it in case you operate the device in future. Observe all the rules and warnings included in the user`s guide. Make sure the device is not damaged in any way. In case of doubt, do not operate the device and contact the suppier. In case of doubt concerning a safe operation of device, contact the suppier. Special attention should be paid to warning signs, housing or packaging of device. Operate the device according to its intended use. The device is not a toy, children should be prohibited from playing with it. On no account can children play with any part of the packaging of this device. Children should be prevented from accessing small parts, for example, clamping screws, pins. These elements can be found on the equipment of device supplied and in case of swallowing they can lead to the choking of child. No mechanical or electrical modifications can be made in the device. Such modifications can cause the wrong operation of device, incompatible with standards or they can influence the operation of device in a negative way. No objects should be put into the device through gaps (for example ventialtion gaps). This can cause short circuit, fire or damage to the device. Take care that no water, moisture, dust and dirt gets into the device. This can cause short circuit, electrical shock, fire or damage to the device. Make sure the device is ventilated properly, do not cover ventilation holes and provide a free flow of air around it. The device should be installed inside the rooms. Make sure the device is not exposed to impacts and vibrations. Connecting the device, make sure that electric parameters of power supply network are within the operation range of device. Any connections must be compatible with the installation electrical wiring diagram and with national, or local regulations relating to electrical connections. There is no part in this device that can be replaced by the user himself. All service operations except cleaning and setting up the function, should be carried out by the authorized service staff. Before starting any maintenance operations, you must absolutely disconnect the device from power supply. No benzine, solvents or other chemical agents, which can damage the housing of device can be used for cleaning the device. A soft cloth is recommended for this purpose. estyma electronics www.estyma.pl page 5

1 General information 1. General information * Any connections must be compatible with the assembly electrical wiring diagram of installation and national or local regulations as regards electrical connections. * There is no part in this device, which the user can replace himself. All service operations except cleaning or setting up the function, should be carried out only by the authorized service staff. * Before starting any maintenance operations, it is absolutely necessary to disconnet the device from power supply. * No benzine, solvents or other chemical agents which can damage the housing of device can be used. A soft cloth for cleaning is recommended. 1.4 Procedure with the used equipment The electronic device was made from materials, which are fit for recycling only in part. That is why, the device must be returned to the recovery and recycling place of electrical and electronic equipment or handed over to the manufacturer. The device must not be disposed of with otehr household rubbish. 2 Connection 2.1 Electrical wiring Before you start to operate the device, read the whole enclosed user`s guide carefully. The person who makes the installation must have technical experience. Connections made with the use of copper cable should be adapted to the operation at a temperature of up to +75ºC. All the connections must be compatible with the installation electrical wiring diagram and national or local regulations about electrical connections. page 6

Content 2.2 Location The device is intended for the installation only in enclosed spaces. After choosing the place of installation, make sure it meets the following conditions: 1. The installation place must be free of excessive moisture and flammable vapours or vapours causing corrosion. 2. The installation of device cannot be made near electrical equipment of high power, electrical machines or welding equipment. 3. In the place of installation the temperature of ambient cannot exceed 60ºC and it should not be lower than 0ºC. Humidity should range from 5% to 95% without condensation. 2.3 Installation The module should be mounted on the wall in the room selected. There should be a free air circulation in the place of installation and the place should be away from the heating sources, for example, electronic equipment, fireplace, heater or direct solation. It is recommended that the module be mounted at a height not less than 1,5 m over the floor. estyma electronics www.estyma.pl page 7

2 Connection 2.4 Description of connections Name Power supply 5V CAN Binary output Contact T2 T1 DESCRIPTION OF OUTLETS Description Power (connect the power unit 5V/1.2A) Communication interface CAN for connecting the controller of boiler/burner Binary output of open collector type Current efficiency 100mA. Contact input of open/closed type Sensor of room temperature T2 Sensor of room temperature T1 page 8

Content 3 Review of functions 3.1 Control of binary output PIN 1 x; x binary output condition [0 lub 1], PIN number assigned in GSM settings. 3.2 Information about input condition Query command about the input condition T1, T2, STYK module VIDE GSM: Example of reply: estyma electronics www.estyma.pl page 9

3 Review of functions 3.3 Information about the controller of boiler Using the mobile you can easily read out or change the parameters of heating controller from any place. 3.3.1 Commands of queries about the parameters of boiler controller Boiler? Water1? Water2? Command Description Query about the parameters of boiler Tb measured temperature of oiler Tbc calculated temperature of boiler Tbsm temperature of boiler set in the continuous mode (manual) Controller condition of controller (turned ON, turned OFF) Burner condition of burner (TURNED OFF, MODULATION) Boiler mode mode of boiler operation (MANUAL, AUTO) Permission permission for the operation of burner (NO/YES) Example of replies: BOILER: Tb 65.5, Tbc 70, Tbsm 65, Controller ON, Burner MODULATION, Boiler mode AUTO, Permission NO Query about the parameters of hot, tap water circuits Thw mesured temperature of hot water Thwsc temperature of comfort hot water set Thwse temperature of hot water set on economy Program program of hot water (TIME, MANUAL, OFF) Example of replies: (enquiry: Water1?) page 10

Content Solar? Heating1? Heating2?.. Heating16? Estyma? WATER 1: Thw 44, Thwsc 45, Thwse 30, Program MANUAL Query about the parameters of solar installation Example of replies: SOLAR: Power 2500, T1 80.5, T2 100.0, T3 0.0, T4 0.0 Query about the parameters of central heating circuits Explanation of parameters: Tr room temperature Trcs comfort set Tres economical set Program program of heating (TIME, PERMAMENT, OFF, ECON) Example of replies (query: Heating3?) HEATING 3: Tr 23.0, Trcs 22.0, Tres, 19.0, Program PERMAMENT Command of query about input condition T1, T2, STYK: Example of replies: INPUT T1 18.8 Max 26.0 Min 18.0 INPUT. Contact OPEN. Output turned off 3.3.2 Commands of changes of boiler controller settings Module Command Description Boiler: Tbsm Set temperature of boiler in manual mode Range of setting: [40-80] Example of command: 1111 Boiler:Tbsm=65; Bmode Mode of boiler operation Range of setting: [auto = 1, manual = 0] Ctrl Example of command: 1111 Boiler:Bmode=1; ON/OFF of controller Range of setting: [ON = 1, OFF = 0] Example of command: 1111 Boiler:Ctrl=1; Burner Consent for the operation of burner Range of setting: [consent = 1, lack = 0] estyma electronics www.estyma.pl page 11

Water1: Water2: Example of command: 1111 Boiler:Burner=1; Examples of combined commands for Boiler module: 1111 Boiler:Tbsm=70;Ctrl=1; 1111 Boiler:Tbsm=65;Bmode=1;Ctrl=1;Burner=1; Note: Arbitrary combination of commands from Boiler group possible. HWprog Program CWU circuit. 1 and circuit 2 Range of setting: [0 time, 1 permanent, 2 turned off] Heating1: Heating2:.. Heating16: Example of command: 1111 Water1:HWprog=1; CHprog Program CO1-CO16 Range of setting: [0 temporary, 1 permanent, 2 turned off, 3 - economical] Trcs Example of command: 1111 Heating1:CHprog=3; Set, comfort room temperature CO1-CO16 Range of setting: [15.0-30.0] Tres Example of command: 1111 Heating1:Trcs=24.0; Set, economical room temperature CO1-CO16 Range of setting: [10.0-25.0] Example of command: 1111 Heating1:Tres=20.0; Examples of combined commands for Heating module: 1111 Heating1:CHprog=3;Trcs=24.0; 1111 Heating1:CHprog=3;Trcs=24.0;Tres=20.0; 1111 Heating16:CHprog=1;Trcs=21.0; 1111 Heating16:CHprog=1;Trcs=21.0;Tres=18.0; Note: Possible arbitrary combination of commands from Heating group within a particular number of circuit. 4 Main display On the main display you will find the information about the condition of VIDE GSM module, its sensor inputs T1, T2 and contact input and about binary output condition. Your own names can be given to the inputs in menu 5.1. Sensors page 13. page 12

Content 5 Main menu 5.1 Sensors Name Name of input T1 Min. temperature T1 Max. temperature T1 Input of temp. T1 active Name of input T2 Min. temperature T2 Max. temperature T2 Input of temp. T2 active Name of contact input Alarm in contacts when SENSORS Description Allows you to give your own name of the input of temperature measurement T1 Allows you to set lower temperature limit at input T1. If the temperature measured by sensor T1 drops below the value set, the alarm can be triggered. Additionally, set the parameters: input of temp. T1 active on YES. Allows you to set upper temperature limit at input T1. If the temperature measured by the sensor T1 increases above the value set, the alarm can be triggered. Additionally, set the parameters: input of temp. T1 active on YES. Allows you to choose whether the input t1 is active. Activation means that the temperature will be monitored from this input and compared to values Min. Temp. T1 and Max. Temp. T1. Exceeding this threshold will cause the sending of alarm SMS. Allows you to give your own name to the input of temperature measurement T2. Allows you to set the lowwer temperature limit at input T2. If the temperature measured by sensor T2 drops below the value set, the alarm can be triggered. Additionally, set the parameters: input of temp. T2 active on YES. Allows you to set the upper temperature limit at input T2. If the temperature measured by sensor T2 increases above the value set, the alarm can be triggered. Additionally, set the parameters: Input of temp. T2 active on YES. Allows you to choose whether input T2 is active. Activation means that the temperature from this input will be monitored and compared to values Min.temp. T2 and Max. Temp. T2. Exceeding this threshold will cause the sending of alarm SMS Allows you to give your own name to contact input Allows you to choose when the alarm of estyma electronics www.estyma.pl page 13

5 Main menu Contact input active Correction T1 Correction T2 contact input is triggered. Alarm with closed or open contact is possible. Allows you to correct the temperature readout from input T1 by the value set (±3 C). Allows you to correct the temperature readout from input T2 by the value set (±3 C). 5.2 Binary output Control Name BINARY OUTPUT Description SMS remote change of contact Alarm T1 after exceeding the permissible temperature range in the sensor T1, the contact changes into active or inactive (indicate in the logics please) Alarm T2 after exceeding the permissible temerature range in the sensor T2, the contact changes into active or inactive (indicate in the logics please) Alarm T1/T2 after exceeding the permissible temperature range by any sensor of temperature, the contact changes into active or inactive (indicate in the logics please) Logics Straight from inactive into active Denied from active into inactive page 14

Content 5.3 GSM settings PIN of authorization Tel. 1 Telephone 1 active Tel. 2 Telephone 2 active Name GSM SETTINGS Description Here you should give your PIN code for the authorization of GSM connection Telephone number1 to which alarm notices will be sent Turning on/off the notifications to the telephone number 1 indicated Telephone number 2 to which alarm notifications will be sent Turning on/off the notifications to the telephone number 2 indicated. * The Vide GSM module has been equipped with Li-ion battery with the capacity of 600 mah. In case the external power supply is lost, the module is capable to operate on its own up to 4 hours. Change of power supply mode always results in sending the SMS alarm to active telephone numbers. 5.4 Settings Name Operation with controller Contrast of display SETTINGS Description Turning on/off of connection with controller Change of display contrast 5.5 Notices Active notice Time of another alarm Name NOTICES Description Allows you to set whether SMS notices about active alarms are to be sent. You should also remember to set active telephone numbers to which notices will be sent. Allows you to set the frequency of time SMS with communique about the alarm will be sent. estyma electronics www.estyma.pl page 15

5 Main menu 5.6 Language Polish or English at your discretion. 5.7 Remote control panel By connecting CAN bus, vide GSM module can supervice the operation of boilers and make changes in settings from each place at home. Name Boiler Burner CO1...16 circuit (central heating) REOMOTE CONTROL PANEL Description Change of the operation mode into automatic or continuous, turning on.turning off the controller and preview of current temperature. Turning on/turning off the burner, preview of burner condition. Comfort/economical program- determining temperature Program change of circuit operation page 16

Content CWU circuit (hot tap water) Buffer Solars Alarms program. One by one: temporary, permanent, turned off, economical Measured- preview of measured temperature Comfort/economical program fixing temperature Program change of circuit operation program One by one: temporal, permanent, turned off, economical Measured preview of measured temperature Information about the upper/lower set temperature of buffer, and temperature measured. Information about the condition of solar Information about the number of alarms in the boiler controller 6 Specification Power supply Ambient temperature allowed Dimensions (length x height x width) Weight of controller 5v/1.2A 0-60 o C 145mm x 94mm x 32mm 215g estyma electronics www.estyma.pl page 17

6 Specification Manufacturer: Estyma electronics al. Lipowa 4 11-500 Giżycko POLAND tel. +48 87 429 86 75 fax +48 87 429 86 75 biuro@estyma.pl www.estyma.pl page 18