Motogard. Over Temperature Protection System. Installation Instructions

Similar documents
DTA. Motor thermistor relay. Benefits. Description

DTA04. Motor thermistor relay. Benefits. Description

Operating Instructions. For. Alarm Control Module. Model SSR 500

MODEL EUR -5A AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL

vibration switch

ECW-GF, ECW-GF-DP DIGITAL ELECTRONIC CONTROLLERS AND REMOTE DISPLAY PANEL PRODUCT OVERVIEW

Public Safety DAS Annunciator Panel

Resistance heaters. Ventilation systems. Air-air exchangers. Air-water exchangers. Cooling units. Control devices. Calculation and selection

Ordering Key. Dielectric strength

Model 17A00 Expansion Enclosure

PH / ORP Analyzers MODEL OPM223/253. Wedgewood Analytical Inc. Liquid Analytical Measurement & Control Specialists DESCRIPTION FEATURES APPLICATIONS

Installation Instructions CS3 Three Phase Solid State Relay

DE20 INSTRUCTION MANUAL

THERMAL MANAGEMENT SOLUTIONS

Jr. Tech (JT-1, 2, 3) Knowledge Areas

THERMAL MANAGEMENT SOLUTIONS

RE-PR3-E-27 3-Phase Panel Mount 27kW

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

ADDITIONAL INFORMATION

Installation Guide for models:

RSMSD Technical Guide

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

Speed and Frequency Seite 1 von 7

SAFETY INFORMATION AND WARNINGS

The Clark-Reliance Corporation TWIP System Installation and Maintenance Instructions - Form E112 -

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 870 SERIES INDUSTRIAL CONTROL PANELS

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

Schneider Electric Erie T155 Series

C SINGLE-POINT HEAT-TRACING CONTROL SYSTEM PRODUCT OVERVIEW

Commercial and Light Industrial Fire Alarm Control Panel

Operating Manual MS220KA and MSR220KA

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

Dissolved Oxygen Analyzers

AIR-COOLED CONDENSING UNIT UNITS PRODUCED AFTER JANUARY, 1996 INDEX SCHEMATIC DIAGRAM FIG. NO.

910 Series Single-point heat-tracing control system

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

STEAMPRO. Steam Generator Troubleshooting and Service Guide

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Excel-EN Conventional Fire Control Panel

Centro-Matic Automated Lubrication Systems System Controls

RELEASE DEVICE CONTROLS

Construction Electrical

Performance Data. Accessories Enclosure Heaters. curus Component Recognized; File No. E IP 20 CE

Heat Pump Water Heater. Table of Contents

ISIS SAFETY SYSTEM Installation guide

Securitron Magnalock Corporation S. 51 st St., Ste. 102 Phoenix, AZ Phone: (800) MAGLOCK

C SINGLE-POINT HEAT-TRACING CONTROL SYSTEM. product overview

PDD-8PCI. Power Distribution Board With Supervised Interface. Installation and Specifications Manual

7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for Infrastructure & Cities.

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

Unit 3 Machine Composition

PTE0705 Electric Fence Monitor

Reyrolle Protection Devices. 7PG26 DAD High Impedance Current Relay. Answers for energy

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

Lodam Compressor Protection Module. Technical manual. Version 3.0 SE-G1

Table of Contents. Protective Relays

Power Supply Display Module PSDM. Installation and Operation Manual

Wiring Diagrams. 38ARZ ARS ARD Air-Cooled Condensing Units 50/60 Hz

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

Bulletin 1608N MiniDySC Dynamic Sag Corrector

Performance Data. curus Component Recognized; File No. E IP 20

Operator: Save these instructions for future use!

Installation and Operation Manual

C910 Series. Single-point heat-tracing control system

Booster Power Supply Manual

Freeze Protection Thermostat TRACON MODEL GPT 3 Installation and Operation Manual

DIGITAL METERS Large Display Temperature Meters Instruction Manual

Installation, Operating and Maintenance Manual

CURTIS GOLD CUP BREWER

I/O ZONE 560/583 AND OPERATION MANUAL

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

Ring Detect Relays. Model RDR. Installation & Operation. Ph: \ \

FX5 Series Explosion-Proof Electric Air Heaters

Installation Guide IM 1248

Fax (724) Main St.; P. O. Box 248 West Middlesex, PA IMPORTANT NOTICE

MODEL SST 2 40 FREEZE PROTECTION THERMOSTAT MODEL SST FIXED SET POINT THERMOSTAT. Installation and Operation Manual

AL600ULADA. NAC Power Extender. Installation Guide

Addressable Loop Modules

Multiple Input and Output Modules

1 Description. 2 Specifications. HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN

Operator: Save these instructions for future use!

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

920 Series. A dry contact relay is provided for alarm annunciation back to a distributed control system (DCS).

www. ElectricalPartManuals. com GADD MKIII Ground Fault Indication System Instruction Manual Ground Fault Protection

UPM I. Unit Protection Module. Installation and Operation Manual (2015/06)

PSN-1000 & PSN 1000(E) Installation Manual

Monitoring Devices 11/1

Enclosure Heaters and Fan Heaters

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE

PS1240x Series Dual Voltage Access Control Power Supply Systems Operating and Installation Instructions Rev D.01

Electrical. Bi-Metallic Thermal Cutouts. Linear Thermal Cutouts

Installation Guide for models:

Air Conditioning, refrigeration and Appliance Transformers

CENTRO-MATIC - 278B. Model Controller Series C JAN Section - C8. Form Page. Indicates change

MSP1000 Motor Protection Relay

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

Transcription:

Motogard Over Temperature Protection System Installation Instructions

Motogard General Information Motogard Over-Temperature Protection Systems provide immediate overheating protection for: motors, equipment enclosures, semiconductor heatsinks, sleeve bearings, and other related machinery. Note: This device does not monitor the actual temperature but protects against over-temperature conditions. All Motogard systems fully conform to the NEC requirements for integral motor thermal protection. The temperature inside of the motor is monitored at all times by using Positive Temperature Coefficient (PTC) Thermistors embedded in or in contact with the surface. The Motogard Over-Temperature Protection System uses PTC Thermistors to indicate when the equipment has exceeded the set temperature. These Thermistors act as a switch, which when reaching the pre-selected temperature will cause the resistance to increase to virtually infinity. This causes the controller to change the state of the contacts. As the equipment cools the switching action reverses and the controller will then change the state of the contacts back indicating an OK circumstance. THERMISTOR RESISTANCE SWITCHING RESISTANCE THERMISTOR TEMPERATURE SWITCHING TEMPERATURE On Motogard Series 115, 120, and 135 Relays the Thermistors are placed in parallel allowing independent monitoring of 3-6 points in the equipment. On Series 150 Relays, the three Thermistors are wired in series reacting as a single switching point. Although there is a higher resistance switching point on the Series 150, each separate Thermistor will pass 3500 ohms on overtemperature. 2

Series 115 Motogard The Series 115 Motogard is designed to take in up to 6 Thermistors wired in Parallel, and has two Triac output relays. Connections Power Connections: The standard 115 Series Motogard relay is designed to operate off of 120VAC +/-10%, Single Phase, 50/60Hz, and is sold under part number 115101-2. There is a special 230VAC input power version available and sold under part number 115202-2. 3. Be sure power is never applied directly across the contact but always in series with the load. 4. Maximum allowable load 5 Amps at 120/240VAC. 5. The closed output of the Motogard Over temperature Protection System has been specifically designed to operate directly in series with most main line contactors. If a small interposing relay must be used, the sealed burden shall be greater than 10VA. 6. The open output of the Series 115 relay can be used for trip indication. On terminals 1 & 2 connect incoming AC power. Thermistor Connections: 1. Connect one lead of each Thermistor to terminals 6, 7, 8, 9, 10, and 11 respectively. 2. Connect other leads of each Thermistor to Common, terminal 5. 3. Maximum number of Thermistors in parallel: Six (6) 4. Note: If using less than 6 Thermistors. Any unused input Install a 150 Ohm 1/2W resistor from sensor common (terminal 5) to any unused input. Output Load Connections: 1. With power applied to the controller and all input sensors in their low impedance states. Terminal 3 and 4 become the equivalent to a closed contact of an electromechanical relay. 2. With power applied to the controller and all input sensors in their low impedance states. Terminal 3 and 4 become the equivalent to a open contact of an electromechanical relay. 3

Series 120 Motogard The Series 120 Motogard is designed to take in up to 3 Thermistors wired in Parallel, and has a single Triac output relay. Connections Power Connections: The 120 Series Motogard relay is designed to operate off of 120VAC +/-10%, Single Phase, 50/60Hz. Connect 120VAC to input terminals 1 and 2. Thermistor Connections: 1. Connect one lead of each Thermistor to terminals 6, 7, and 8 respectively. 2. Connect other leads of each Thermistor to Common, terminal 5. 3. Maximum number of Thermistors in parallel: Three (3) 4. Note: If using less than 3 Thermistors. Any unused input Install a 150 Ohm 1/2W resistor from sensor common (terminal 5) to any unused input. Output Load Connections: 1. With power applied to the controller and all input sensors in their low impedance states. Terminal 3 and 4 become the equivalent to a closed contact of an electromechanical relay. 2. Be sure power is never applied directly across the contact but always in series with the load. 3. Maximum allowable load 3 Amps at 120/240VAC. 4. The closed output of the Motogard Over temperature Protection System has been specifically designed to operate directly in series with most main line contactors. If a small interposing relay must be used, the sealed burden shall be greater than 10VA. 4

Series 135 Motogard The Series 135 Motogard is designed to take in up to 3 Thermistors wired in Parallel, and has a Form C Mechanical Output relay. Connections Power Connections: The 135 Series Motogard relay is designed to operate off of 120VAC +/-10%, Single Phase, 50/60Hz. Connect 120VAC to input terminals 1 and 2. Thermistor Connections: 1. Connect one lead of each Thermistor to terminals 6, 7, and 8 respectively. 2. Connect other leads of each Thermistor to Common terminal 9. 3. Maximum number of Thermistors in parallel: Three (3) 4. Note: If using less than 3 Thermistors. Any unused input Install a 150 Ohm 1/2W resistor from sensor common (terminal 9) to any unused input. Output Load Connections: 1. Terminals 3, 4 and 5 comprise a set of Form C contacts with terminal 4 common, Terminal 5 is the open side and terminal 3 is the closed side. 2. Be sure power is never applied directly across the contact but always in series with the load. 3. Maximum allowable load 5 Amps at 120/240VAC or 28VDC. 4. The closed output of the Motogard Over temperature Protection System has been specifically designed to operate directly in series with most main line contactors. If contact current is greater than 5 Amps at 115VAC, an interposing relay must be used. 5. The open output of the Series 135 relay can be used for trip indication. 5

Series 150 Motogard The Series 150 Motogard is designed to take in up to 3 Thermistors wired in Series (1 input), and has a Form C Mechanical Output relay. Connections Power Connections: The 150 Series Motogard relay is designed to operate off of 120VAC +/-10%, Single Phase, 50/60Hz. Connect 120VAC to input terminals 1 and 2. Thermistor Connections: 1. Connect one lead of the series Thermistor to 3. 2. Connect other lead of the series Thermistor to terminal 4. 3. Maximum number of Thermistors in series: Three (3) 4. Note: Resistance input across terminals 3 and 4 should be between 150 Ohm to 500 Ohm in ambient conditions. If the resistance measures less than 150 Ohms a 150 Ohm 1/2W resistor should be installed in series with the Thermistors to prevent false trips. Output Load Connections: 1. Terminals 5, 6 and 7 comprise a set of Form C contacts with terminal 6 common, Terminal 5 is the open side and Terminal 7 is the closed side. 2. Be sure power is never applied directly across the contact but always in series with the load. 3. Maximum allowable load 4 Amps at 120/240VAC. 4. The closed output of the Motogard Over temperature Protection System has been specifically designed to operate directly in series with most main line contactors. If contact current is greater than 4 Amps, an interposing relay must be used. 5. The open output of the Series 150 relay can be used for trip indication. 6

Switching temperatures (Nominal) Item Identification Part Number T8060* T8070* T8080* T8090 T8100 T8110 T8120* T8130 T8140 T8150 T8160 T8170 T8180* T8190* Centigrade ºC +/-5º Fahrenheit ºF +/-9º Identifying wire colors T9060** T9070** T9080** T9090** T9100** T9110** T9120** T9130** T9140** T9150** T9160** T9170** T9180** T9190** 60 70 80 90 100 110 120 130 140 150 160 170 180 190 140 158 176 194 212 230 248 266 284 302 320 338 356 374 Gray Brown White Green / Green *Consult factory - Non-stocked temperatures. Consult factory for mimimums **Consult factory - Special order item. Consult factory for mimimums Red / Red Brown / Brown Grey / Grey Blue / Blue Blue Black / Black Blue / Red Green Red Black / Grey Available in numerous designs from a simple thermistor to a spring loaded bearing probes. Consult factory for special applications. 7

Motogard Relay Models Model No. Operating Characteristics Input Rating Output Rating Input Resistance Control Isolation Reset Series 115 Series 120 Series 135 Series 150 115101-2 120101 135101 150101 6 Inputs 2 Triac Outputs 1 N.O.* 1 N.C.* 120/240 Volts AC 5 amp continuous Controller ON with 500 ohms or less - OFF with approx. 1500 ohms or more 3 Inputs Single Triac Output N.C.* 3 Inputs Form C Relay Output 120VAC± 10%, Single Phase, 50/60 Cycles 120/240 Volts AC 3 amp continuous Controller ON with 500 ohms or less - OFF with approx. 1500 ohms or more 120/240 Volts AC or 28 Volts DC 5 amp continuous Controller ON with 150 to 500 ohms - OFF with approx. 1500 ohms or more Over Temperature Protection System Controller output, excitation, and sesor input electrically isolated from each other Controller excitation only isolated from output and sensors Automatic Controller output, excitation, and sesor input electrically isolated from each other 1 Input Form C Relay Output 120/240 Volts AC 4 amp continuous Controller ON with 150 to 500 ohms - OFF with approx. 3500 ohms or more Controller output, excitation, and sesor input electrically isolated from each other Dimensions 5.50" W x 4.25" L x 3.12"H 3.24" W x 2.25" L x 2.50" H 5.75" W x 2.0" L x 5.68" H 3.25" W x 2.25" L x 2.50" H Enclosure Potted in "NEMA" 12 steel case Potted in polyester case Mounted in welded steel case Potted in polyester case * Series 115 and 120 Motogard Controllers use output Triacs that have been specifically selected to operate directly in series with main line contactors. If a small interposing relay must be used, the sealed VA rating of the interposing relay should be greater than 10VA. Other Products MADE IN AMERICA Copyright 2016 by AMETEK. All Rights Reserved. Made in the USA. 1080 North Crooks Road, Clawson, MI 48017 Phone: 248-435-0700 Toll Free: 800-635-0289 Fax: 248-435-8120 www.ametekfactoryautomation.com MOTO.M4R 3/18 Z416