Using the DewMaster Deluxe Dew Point/ Humidity Hygrometer

Similar documents
Using the Model 1500 Portable Chilled Mirror Hygrometer

Using the DewTrak II Dew Point/ Humidity Transmitter

DEW POINT HYGROMETER MODEL DPH-2020/2012 BULLETIN DPH-2020/2012 can be used to extend the lower measurement limit of the system.

Specifications: ACCURACY: RH: ±1% Temperature: ±0.5 C. Dew point: Typically, +/-2.0C above 0C; +/-3.0C 0 to -60C OPERATING RANGE:

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

573 Dew Point Mirror. Industrial Chilled Mirror Hygrometer. Typical applications:

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

MODEL DPS1 Heated Dew Point Measuring System OPERATORS MANUAL

DF-340E PROCESS ANALYZERS APPLICATIONS FEATURES

MICHELL GROUP. Advanced Industrial Hygrometry and Process Instrumentation. Company Profile, 2011

DP 300 mobile dew point instrument

air.iq Moisture Analyzer Packaged Solution GE Measurement & Control Applications Features

Dew-Point Transmitters and Instruments

INSTALLATION, OPERATION INSTRUCTIONS FOR FLOW SWITCHES 62-9FS & FS

Weed Instrument Application Driven Designs for Pharmaceuticals and Biotech

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring

DEW-POINT SENSOR TRAINING. Moisture Sensors DP & Rh The basic low cost solution With a wide range

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

Model gffoz Process Ozone Sensor (In-Line)

DRY-PAK INDUSTRIAL AIR DRYER Installation and Instruction Manual

Beam-A-Temp Portable Infrared Thermometer Measures up to 1832 F/1000 C with 50:1 distance to target ratio. Specifications

PDM 75 Portable Hygrometer OPERATORS MANUAL

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features:

Ventostat Wall Mount. Amphenol. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Advanced Sensors. Features:

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

Accessories, interfaces, sensors and complete solutions.

AIRFLOW MEASUREMENT AND CONTROL PRODUCT CATALOG. Phone: 877-4GNTROL ( ) - Internet: GreenTrol.com. r1f

VWR LABORATORY REFRIGERATORS AND FREEZERS. Versatile Storage Options Designed for Your Needs

Model OEM-2 INSTRUCTIONS FOR USE

Duct Humidity/Temp Sensor

VWR symphony CO 2 INCUBATORS

INSTRUMENTATION AND CONTROL DEVICES FOR HVAC

TOOLS AND INSTRUMENTS

User s Guide. RHCL-2 Portable RH/Temperature Calibrator. Shop online at omega.com

Constant climate chambers

XRD XRD-1500 High-Temperature Oven. Innovation in Material Science...

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

Temperature Solutions Line Card

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

Cabinet Cooler Systems

Moisture and Hydrocarbon Dew Point Measurement

Supertron Sensing Pte Ltd Certificate No. : LA C Blk 16 Kallang Place #07-04 Issue No. : 4 Singapore Date : 04 February 2015

Desiccant Air Drying Technologies HCS Series HCL Series HCT Series

Safety vacuum drying oven for flammable solvents

Optidew & Optidew Vision High Performance Optical Dew-Point Transmitter User s Manual

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

Temperature Sensors & Compression Seal Fittings

Moisture and Hydrocarbon Dew-Point Measurement

VWR Laboratory Refrigerators and Freezers

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES

HT-1300 Series. Temperature and Humidity Duct Sensor. Product Bulletin. Power Supply VDC / 24 VAC. Humidity Accuracy 2.5% RH from 10 to 95% RH

OptiCal Humidity and Temperature Calibrator User s Manual

Sitron s CF Line of Flow Switch Monitors

HIGH CAPACITY PRODUCT LINE

Bench Series Ovens Models 21 / 31 / 51 Operating Manual

Accuracy by Design Products for the HVAC Professional

Electronic Flow Switches

vacuum FLOW support excellence experience

Membrane Technologies DMD Series Dryers ESM Series Dryers

Benefits & Technology for Decentralizing a -40 F Dew Point

Model DewTech390. Model DewTech 390. Chilled Mirror Dew Point Hygrometer. Instruction Manual

Thermo Scientific Heratherm Heating and Drying Ovens. efficient

Titus Air Systems. TDD Series. The need for clean and dry compressed air. Energy efficiency

Constant climate chambers

Accessories, interfaces, sensors and complete solutions.

Thermo Scientific Heratherm Microbiological Incubators. safe. Part of Thermo Fisher Scientific

Constant climate chamber with humidity

Miniature Infrared Temperature Sensors with Optional Touch Screen Display. PSC-SSS-PM with touch screen display (-CRT version)

Enclosed Scroll Air Compressor System SES 3-5 HP

Series 5000 Hydrazine Analyzer Model 60002

4000TOC Sensor. Continuous On-Line Measurement Total Organic Carbon Monitoring. THORNTON Leading Pure Water Analytics

Model Super TJE. Ultra Precision Pressure Transducer DESCRIPTION FEATURES

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

Constant climate chambers

Constant climate chamber with ICH-compliant illumination

RNC Series SCFM Global Air Treatment

HIGH CAPACITY PRODUCT LINE

RNC Series SCFM Global Air Treatment

HYGROPHIL H process hygrometer

THE STANDARD OF EXCELLENCE WDG-V SERIES COMBUSTION ANALYZERS

Exceptional data integrity. Complete peace of mind.

Promet I.S. Promet I.S. Process Moisture Analyser

Brooks MT3600 Series Metal Tube Variable Area Flowmeters

Vacuum drying oven for non-flammable solvents

EasyLog Data Logger Series

Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls

Rev B, 9/2/2009. Kodiak Chiller Overview

Thermo Scientific Heratherm Heating and Drying Ovens. efficient safe easy. Part of Thermo Fisher Scientific

PRODUCT LINE. Highest Quality, Best Service

Industrial Strength Leak Detection

OG5000 Ozone Generator Model OG5000B-A. User Manual

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

twin tower desiccant compressed air dryers flow capacity: 200-9,000 scfm (340-15,300 Nm3/hr)

Outside Air Humidity & Temperature Sensor

Oxygen Sensing Solutions

FA compressed air plants (refrigeration/adsorption driers) - granulate driers - medical gases - non-corrosive gases, e. g.

SKYL-TECH, INC. a world leader in validation technology. validation assemblies. thermocouples. feedthrus. consulting

SEC SIGNATURE ETO MONITOR TRAINING SENSOR ELECTRONICS CORPORATION

Transcription:

JAN 0 ::0 AM SERVOLOCK APPLICATION NOTE 0_0_ Rev Using the Deluxe Dew Point/ Humidity Hygrometer The Model is a versatile, multi-function, optical chilled mirror hygrometer designed to continuously measure the moisture content in gases. Available in benchtop, NEMA, or 9 inch panel mount configurations, the readily adapts to a wide range of applications. It offers Users a wide range of sensor choices and interface options. It has been field proven in laboratories, industrial environments, and many customized applications. The uses the chilled mirror (CM) dew point temperature condensation principle to determine the water vapor concentration in gas mixtures, and a precision platinum resistance thermometer to measure the mirror temperature. The CM uses a thermo-electric device to control the temperature of the mirror in determining dew point. Since it is a direct measurement of dew point and thus a Primary Standard Measurement Technique. The is highly regarded by laboratories and manufacturing facilities for its accuracy, quick dry down, fast response in detecting upset conditions and long life characteristics. The may be fitted with a precision air temperature sensor (needed to determine RH), pressure transducer, and a wide range of either local or remote chilled mirror sensors. Two main types of chilled mirror sensors are available for the Dewmaster: the remote mounted D-Probe featuring a two stage air cooled chilled mirror or the S-Series sensor- available in both local and remote mount configurations. Depending on the desired measurement range, the S-Series sensor is available in Two or Three stage chilled mirror configurations. To accommodate different cooling thresholds, the S-Series sensor may be air cooled, fan cooled or liquid cooled. In contrast, the D-Probe is only available as a Two-Stage chilled mirror. But since it is configured as a probe, it may be used in a wide array of applications including ambient air monitoring, insertion into glove boxes, HVAC ducts, environmental test chambers, circulation pipes, refrigerated storage rooms, engine test filter rooms, NEMA with Optional Chiller Table Top 9 inch Rack Mount 7.0 C DP.7 C AT. % RH Inc. An ISO 900 Certified Company 99 River Road. Hudson. MA. 079 Main: + (08) -900. Fax:+ (08) 8-98 www.edgetechinstruments.com

The offers many standard features including: PRIMARY STANDARD MEASUREMENT: Chilled Mirror measurement technique NIST Traceable calibration certificate Automatic Balance Cycle (ABC) automatically re-standardizes and corrects for contaminants Programmable Balance Cycle: ABC at programmed intervals or (Manual ABC) Real Time Clock with date Two selectable Analog Outputs (-0 ma, 0-0 ma, 0- VDC, 0-0 VDC scaleable) RS- Serial Interface Two programmable electrically isolated alarm relays Pressure Transducer input for psychometric variable Universal VAC Power Input Environmental Configuration Options Table Top standard NEMA 9 inch panel mount JAN 0 ::0 AM SERVOLOCK 7.0 C DP.7 C AT. % RH APPLICATIONS Metrology Labs Environmental Chambers Quality Assurance Labs HVAC systems & Test Labs Laser Lab Air Make-up Clean Rooms Diffusion Furnaces Product Drying Chambers Environmental Testing Food Packaging Medical Packaging Data Center Air Makeup RH exposure testing Fuel Cell Testing Furnace Applications Pharmaceutical Powder Drying Materials Testing Plastics/ Molding Process Chemical Reactors Heat Treat/ Annealing Ovens Engine testing Calibration of other humidity sensors Page Inc. An ISO 900 Certified Company 99 River Road. Hudson. MA. 079 Main: + (08) -900. Fax:+ (08) 8-98. www.edgetechinstruments.com

Chilled Mirror Compatibility Chart Applications CM Configuration General Purpose Gases Acids Caustics Salts Organics Nuclear Application High Temperature Chrome Plated Copper A D D C C D C Stainless Steel A B B B B C B Platinum A A A A A A A Teflon Coated Chamber A A A A A D D High Pressure Chamber A NR NR NR NR NR A A B C D NR Excellent Very Good Good Not recommended Not Rated BENEFITS of the Chilled Mirror Sensor: Direct measurement method: recognized as a Primary Standard Technique Improve your quality control: Excellent Precision and Stability Reduce Maintenance Costs: Robust, Long Life, No moving parts, No consumables Rapid dry-down time in comparison to other technologies S series chilled mirror sensors come with auxiliary heat exchanger ports (/ tube) for connection to chilled liquid for measuring extremely low dew points. Eliminate Scrap or Lost Time: Fast response in responding to upset process conditions. Sensor Notes/ Sampling Configuration Options The D-probe is mounted (remote) tethered on a signal cable. The S-series sensor can be mounted either local at the or remote tethered. The standard D-Probe is configured for diffusion sampling. To measure an extracted flow of sample gas with the D-Probe, the optional flow through cover (SC) or the Sample Chamber (SC) may be installed (includes fittings). A precision air temperature probe is optional. Temperature can be used to calculate and display Relative Humidity. The SMU vacuum pump module may be used to extract a gas sample from the measurement point and direct it through the sensor. Ideal flow is - SCFH An optional chiller may be used to obtain temperature depressions greater than 9C when using the S-series sensors. Chiller liquid ports are provided on all S sensors. Optional Pressure transducers may be specified to determine sample pressure and Psychometric calculations. Inc. An ISO 900 Certified Company 99 River Road. Hudson. MA. 079 Main: + (08) -900. Fax:+ (08) 8-98. www.edgetechinstruments.com Page

TO ORDER:. Determine type of measurement: DewPoint, Relative Humidity, Pressure, Temperature. If you need to measure RH, then you also need to include the temperature probe.. Determine the range of measurement and type of sensor: D-Probe or S-Series.. Your application determines whether to select local mounted sensor(s) or remote.. Select type enclosure based on the application: Table Top (standard), NEMA, or Rack.. Select Sensor Type. Select Options such as temperature sensor, Pressure Transducer, PPMv measurement,.. 7. List as separate line items additional choices such as Accessories, Calibration Packages, and Extended Warranty. DM- - - ENCLOSURE SENSOR OPTIONS For Example: DM-S-ATDM would be a Table Top with S fan cooled CM sensor and air temperature probe. Page Inc. An ISO 900 Certified Company 99 River Road. Hudson. MA. 079 Main: + (08) -900. Fax:+ (08) 8-98. www.edgetechinstruments.com

JAN 0 ::0 AM SERVOLOCK JAN 0 ::0 AM SERVOLOCK Configurations Available: Enclosure: DM- standard is Table Top -N NEMA Wall mount -RMDM 9 inch Rack Mount Kit -PMDM 9 inch Rack Mount Kit Sensor: JAN 0 ::0 AM SERVOLOCK 7.0 C DP.7 C AT. % RH STANDARD (DM): TABLE TOP NEMA WALL MOUNT (DM-N): * Shown with optional sampling and chiller 7.0 C DP.7 C AT. % RH RACK MOUNT (DM-RMDM): * INCLUDES RACK SUPPORT TRAY & RACK FRONT PANEL 7.0 C DP.7 C AT. % RH PANEL MOUNTING KIT (DM-PMDM) * INCLUDES SUPPORT TRAY & MOUNTING BRACKETS Page Inc. An ISO 900 Certified Company 99 River Road. Hudson. MA. 079 Main: + (08) -900. Fax:+ (08) 8-98. www.edgetechinstruments.com

Chilled Mirror Sensors are available in the following configurations: CM Sensors Description Stages TEC TEC Cooling Notes Depression DS Probe Style Air Cooled Chrome Pltd Mirror 0C DSSS Probe Style Air Cooled SS Mirror 0C DSPT Probe Style Air Cooled Platinum mirror 0C S Flow-thru (upto 00 psig) Air Cooled Chrome Pltd Mirror 0C SP FT- Hi Press(upto 900 psig) Air Cooled Chrome Pltd Mirror 0C SPT Flow-thru (upto 00 psig) Air Cooled Platinum mirror 0C SSS Flow Thru (upto 00 psig) Air Cooled SS Mirror 0C ST Flow-thru (upto 00 psig) Air Cooled TF coated chamber 0T SSC Flow-thru (upto 00 psig) Fan Cooled Chrome Pltd Mirror C SSCP Flow-thru (upto 900 psig) Fan Cooled Chrome Pltd Mirror C SSCPT Flow-thru (upto 00 psig) Fan Cooled Platinum mirror C SSCSS Flow-thru (upto 00 psig) Fan Cooled SS Mirror c SSCT Flow-thru (upto 00 psig) Fan Cooled TF coated chamber C S Flow-thru (upto 00 psig) Fan Cooled Chrome Pltd Mirror 9C ST Flow-thru (upto 00 psig) Fan Cooled TF coated chamber 9C SP Flow-thru (upto 900 psig) Fan Cooled Chrome Pltd Mirror 9C SSS Flow-thru (upto 00 psig) Fan Cooled SS Mirror c SPT Flow-thru (upto 00 psig) Fan Cooled Platinum mirror 9C Options: -ATDM Air temperature probe, stainless steel sheath with 0ft cable and connector -PTDM Pressure Transducer, 0 to PSIA or 0-0PSIA, or 0-00PSIA -PPM PPMv measurement @ fixed pressure -SA/. 0.C Special accuracy, traceable to NIST (Certified) -SA/. 0.C Special accuracy, traceable to NIST (Certified) Accessories/ Special Services: -FIL Filter kit: includes fittings and additional elements; rated for. micron particulate -SMU Sample Module Universal, /0 VAC operation -SC -SC -CAB -CHL -YEW Sample Cover: Flow Through Cover for D-Probe (near ambient pressure sample gas) Sample Chamber: Flow Through Chamber for D-Probe (up to 00 PSIG sample gas) channel cabinet holds up to rack mounted Dewmaster modules Self-Contained Chiller for use with S-Series sensors to measure lower dew points Year Service Contract Page Inc. An ISO 900 Certified Company 99 River Road. Hudson. MA. 079 Main: + (08) -900. Fax:+ (08) 8-98. www.edgetechinstruments.com

Sensor Configurations: S-Series Sensor Table Top w/ Local S- Sensor Top View of JAN 0 ::0 AM SERVOLOCK 7.0 C DP.7 C AT. % RH Front View of S- Series Chilled Mirror Sensor mounted locally on the back panel of Page Inc. An ISO 900 Certified Company 99 River Road. Hudson. MA. 079 Main: + (08) -900. Fax:+ (08) 8-98. www.edgetechinstruments.com

S- Series Chilled Mirror Sensor mounted remote from the (Temperature and pressure probes also shown) S-Series Sensor Air Temperature probe Pressure Transducer JAN 0 ::0 AM SERVOLOCK 7.0 C DP.7 C AT. PSIA C/T Page Inc. An ISO 900 Certified Company 99 River Road. Hudson. MA. 079 Main: + (08) -900. Fax:+ (08) 8-98. www.edgetechinstruments.com

D- Series Chilled Mirror Sensor probe mounted remote from JAN 0 ::0 AM SERVOLOCK 7.0 C DP.7 C AT. % RH Remote D-Probe & optional Temperature Sensor Laboratory testing Environmental Testing HVAC Test Chambers InSitu testing of Air Ducts Moisture Sensitive Manufacturing Process Chamber Testing Lithium Battery Manufacture Glove Box Applications Drier Applications Modified Atmosphere Packaging DewPoint/ RH Gas Blending Pharmaceutical / Biopharm process Food Storage Engine Test Cell Monitoring Drying of Plastic Pellets Furnace Atmospheres / Heat Treat Curing Ovens Museum Controlled Environments High Temperature Process Gas analysis Bakery- Proofing Page7 Inc. An ISO 900 Certified Company 99 River Road. Hudson. MA. 079 Main: + (08) -900. Fax:+ (08) 8-98. www.edgetechinstruments.com

Flow Through D-Probe Flow Through Sampling with D-Probe and SC or SC SC Low Pressure Flow Through Chamber SC High Pressure Flow Through Chamber OR Insert the Probes close to the measuring point and monitor remotely! Page8 Inc. An ISO 900 Certified Company 99 River Road. Hudson. MA. 079 Main: + (08) -900. Fax:+ (08) 8-98. www.edgetechinstruments.com

Other variations of the D-Series remote sensor probe JAN 0 ::0 AM SERVOLOCK 7.0 C DP.7 C AT. % RH C/T Duct Mount w/ Remote D-Probe & Optional Temperature Sensor Room Air Control Clean Room Environments Environmental Testing HVAC Test Chambers InSitu testing of Air Ducts Glove Box Applications Pharmaceutical / Biopharm process Food Storage Furnace Atmospheres / Heat Treat Curing Ovens Museum Controlled Environments Convenient Gasket Sealed Mounting Plate for use with the D-Probe! Page9 Inc. An ISO 900 Certified Company 99 River Road. Hudson. MA. 079 Main: + (08) -900. Fax:+ (08) 8-98. www.edgetechinstruments.com

Other variations of the D-Series remote sensor probe (cont) JAN 0 ::0 AM SERVOLOCK 7.0 C DP.7 C AT. % RH C/T w/ D-Probe Pipe Mount Standard Configuration of D-Probe Pipe mount rated to 00 psig Max. In High Pressure applications, pressure may also have to be measured for accurate Dew Point measurements. (. inch male NPT threaded penetration) Page0 Inc. An ISO 900 Certified Company 99 River Road. Hudson. MA. 079 Main: + (08) -900. Fax:+ (08) 8-98. www.edgetechinstruments.com

Using the SMU Vacuum Pump Module with the S-Series Chilled Mirror Sensor From sampling point Filter Kit ¼ inch Tubing S-Series Sensor SAMPLE MODULE JAN 0 ::0 AM SERVOLOCK 7.0 C DP.7 C AT. % RH Page Inc. An ISO 900 Certified Company 99 River Road. Hudson. MA. 079 Main: + (08) -900. Fax:+ (08) 8-98. www.edgetechinstruments.com

Using the SMU Vacuum Pump Module with the D-Probe JAN 0 ::0 AM SERVOLOCK 7.0 C DP.7 C AT. % RH D-Probe Sensor From sampling point Filter Kit Sample Chamber ¼ inch Tubing SAMPLE MODULE Page Inc. An ISO 900 Certified Company 99 River Road. Hudson. MA. 079 Main: + (08) -900. Fax:+ (08) 8-98. www.edgetechinstruments.com

Working with High Positive Pressure Sample Gas and the Remote Mounted Flow Through S-Probe Sensor S-Series Sensor Vent to Atmospheric Pressure Positive Pressure Sample Input Above PSIG Pressure Regulator (as needed) Filter Kit as needed SCF SCFH H FlowMeter as needed - SCFH JAN 0 ::0 AM SERVOLOCK C/T 7.0 C DP.7 C AT. % RH Page Inc. An ISO 900 Certified Company 99 River Road. Hudson. MA. 079 Main: + (08) -900. Fax:+ (08) 8-98. www.edgetechinstruments.com

Using an external Chiller to acquire lower dew point measurements S-Series Sensor Sample gas -WAY VALVE Sample gas Drain port JAN 0 ::0 AM SERVOLOCK 7.0 C DP.7 C AT. % RH EXTERNAL CHILLER Chilled Liquid EXTERNAL CHILLER Draining the Chilling Liquid during Maintenance Sample gas S-Series Sensor Sample gas -WAY VALVE Chilled Liquid JAN 0 ::0 AM SERVOLOCK 7.0 C DP.7 C AT. % RH Chilled Liquid Drain Valve at the lowest point to drain liquid Page Inc. An ISO 900 Certified Company 99 River Road. Hudson. MA. 079 Main: + (08) -900. Fax:+ (08) 8-98. www.edgetechinstruments.com

Channel Cabinet for Rack Mounted DESIGN FEATURES Accommodates up to x Rack Mount Modules Highly styled and versatile steel cabinet Common Power Strip. Supplied w/ See-Thru front door with tempered glass window. Solid steel removable side panels. Equipped with 0V AC, CFM exhaust fan for cooling. Cable access holes on top and bottom. Supplied with steel wall mounting bracket. Four mar resistant feet on bottom surface. Finish: Smooth Black Powder Coating in H x. W x 7.7 D JAN 0 ::0 AM SERVOLOCK 7.0 C DP.7 C AT. % RH JAN 0 ::0 AM SERVOLOCK 7.0 C DP.7 C AT. % RH JAN 0 ::0 AM SERVOLOCK 7.0 C DP.7 C AT. % RH Page Inc. An ISO 900 Certified Company 99 River Road. Hudson. MA. 079 Main: + (08) -900. Fax:+ (08) 8-98. www.edgetechinstruments.com