This document is downloaded from DR-NTU, Nanyang Technological University Library, Singapore.

Similar documents
Publication American Institute of Physics. Reprinted with permission.

Construction of a Calibration System for Power Responsivity of Optical detectors Using Different Laser Sources

Spectrum Detector, Inc.

Quality Manual of Optical Power Measurements

Laser Safety and Classification Full Version (CA-1110) Advanced Version (CA-1111) Basic Version (CA-1112)

Development of a variable output LED-365 irradiance standard

The FEL Facility Optical Diagnostics and FEL Characterization

Our photo detectors are offered for both power or energy measurements. Measure as low as a few femtojoules in energy or a few picowatts in power.

Our photo detectors are offered for both power or energy measurements. Measure as low as a few femtojoules in energy or a few picowatts in power.

Low-Power Detectors. Key Features. 818 Series. Power levels from pw to 2W. Wavelengths from 190 nm to 1800 nm. Proprietary detector optics

Development and setting up a calibration facility for UV sensors at high irradiance rates

818 Series Low-Power Detectors

SPECTRAL INSTRUMENTATION

INTERNATIONAL JOURNAL OF RESEARCH GRANTHAALAYAH A knowledge Repository

Diode-Pumped Solid-State Blue Lasers

MODEL-BASED OPTIMIZATION OF AN INFRARED GAS SENSOR

The J22 and J23 series are high performance InGaAs detectors operating over the spectral range

Beam Analysis nm and µm - Pyroelectric Array Camera. Pyrocam TM IIIHR & Pyrocam IV Series

Questionnaire on activities in radiometry and photometry. Reply from: Korea Research Institute of Standards and Science (KRISS)

818 Series. Low-Power Detectors ABSOLUTE SPECTRAL RESPONSIVITY (A/W)

Compact Portable QEPAS Multi-gas Sensor

REVIEW OF ULTRAVIOLET AND HIGH POWER LASER MEASUREMENT STANDARDS AT NIST *

Recent Advances in Solid State Lasers and Nonlinear Optics for Remote Sensing

Beam Analysis nm and µm - Pyroelectric Array Camera. Pyrocam TM IIIHR & Pyrocam IV Series

Indium Gallium Arsenide Detectors

Office of Nonproliferation and Verification Research and Development University and Industry Technical Interchange (UITI2011) Review Meeting

Instruments Designed for POF & Fibre Optic Cable Testing

Polarized Light Scattering of Smoke Sources and Cooking Aerosols

North Dakota State University Laser Safety

Bunch Length Interferometer System

Understanding total measurement uncertainty in power meters and detectors

An FT-NIR Primer. NR800-A-006

*For inquiries and questions about lasers, see the Yellow-Page.

E11 Tests of trace gas concentration multicomponent. monitoring system

MADE FOR THE TRADE! FIBER OPTIC. professional. XL fibertools Series. instruments

Integrating Sphere Detectors. Wide Range of Stock Items. Individual Custom Configuration and Design. OEM Design and Production. Traceable Calibrations

AIDA Advanced European Infrastructures for Detectors at Accelerators. Presentation. LumiCal alignment system, status report

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

VTT silicon photonics driving new business growth in Finland

palmotdr Series Handheld OTDR

Compact Sensor Heads for In-situ and Non-Contact Standoff Gas Sensing using TDLAS in Harsh Environments

Laser Analyzers for NH3 Safety Monitoring and Leak Detection

OTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL

MADE FOR THE TRADE! FIBER OPTIC. professional. XL fibertools Series. instruments

Direct measurement of the aerosol absorption and extinction cross section for a variety of chemical and biological simulants in the LWIR

FPI Detectors Pyroelectric Detectors with Spectrometer Functionality

University of California Santa Barbara Department of Chemistry and Biochemistry Optical Characterization Facility. Safe operations manual

FTIR-OEM IR source, interferometer & detector modules for modular and OEM applications

CALIBRATION HOW IT WORKS

Laser Distance Sensor Type M Analog-Output

Optical Time Domain Reflectometry (OTDR)

UC INSTRUMENTS GM8036 LASER SWEEP OPTICAL SPECTRUM ANALYZER (1525 ~ 1610 nm) Technical Specifications v1.01 March, 2011

Measuring THz Radiation choose a Pyroelectric Detector or Golay Cell?

POWER & ENERGY METERS BEAM PROFILING THZ MEASUREMENT COMPANY PROFILE

Infrared Technology And Applications Xxviii (Proceedings Of Spie)

ENHANCED VISION - INFRARED 1

Low-power laser-based carbon monoxide sensor for fire and post-fire detection using a compact Herriott multipass cell

POWER & ENERGY METERS BEAM PROFILING THZ MEASUREMENT COMPANY PROFILE

A Cost Effective Multi-Spectral Scanner for Natural Gas Detection

Status and perspectives of the Virgo detector

Novel detectors for traceable THz power measurements

Application Note. Which characterization method is best for your application? The Future of Thermal Imaging is Here!!!

Analisi del Focus-shift su sorgenti multikw. Luca Porcelluzzi Ophir Spiricon Europe GmbH

DEVELOPMENT OF THE INFRARED INSTRUMENT FOR GAS DETECTION

UV CURING SYSTEMS OmniCure UV Curing Lamp & LED Systems TO ORDER, PLEASE CALL

A Fresnel Reflection-Based Optical Fiber Sensor System for Remote Refractive Index Measurement Using an OTDR

Experiment Study in Optical Fiber Temperature Monitoring

6340(Print), ISSN (Online) Volume 4, Issue 2, March - April (2013) IAEME AND TECHNOLOGY (IJMET)

CALIBRATION HOW IT WORKS

Recommended Work Area Controls

Pyroelectric detectors based on high-performance PMN-PT single crystals

More Precision. thicknesssensor // The sensor for precise thickness measurements

Reverse Package Infrared LED IR25-21C/TR8

mach 5 100kHz Digital Joulemeter: M5-SJ, M5-IJ and M5-PJ Joulemeter Probes

Date: Wednesday, January 31, 2018 Time: 8:30 am 5:00 pm Location: Moscone West (Room 2018, Level 2)

Optical Measurement Techniques for LED Clusters and LED Safety

On-chip optical detectors in Standard CMOS SOI

Long-distance remote simultaneous measurement of strain and temperature based on a Raman fiber laser with a single FBG embedded in a quartz plate

Experimental Study to Evaluate Smoke Stratification and Layer Height in Highly Ventilated Compartments

Instruction Manual. gray Mounted Detectors. for. greenteg AG Technoparkstrasse Zürich, Switzerland T: F:

Model ID-441-C InGaAs Near Infrared Detector with Preamplifier and Thermoelectric Cooler Operating Instructions

SECTION 1: STARTING 1.1 UNPACKING AND INSPECTION

CALIBRATION HOW IT WORKS

Break-in Detection and Alarm System

SiC UV Sensor Probes Catalog

Microspectrometers, which read color and the results

palmotdr Series Handheld OTDR

Optical Time-Domain Reflectometry for the Transport Spatial Filter on the OMEGA Extended Performance Laser

Agilent 81663A DFB Laser 8165xA Fabry-Perot Lasers

Optical Sensor (2A) Optical Sensor Type Optical Sensor Characteristics. Young Won Lim 9/12/09

Co-60 irradiator for therapy level calibrations at SSDLs

760nm Single mode VCSEL with Peltier Element and Thermistor in TO510

Propagation loss in optical fibers (01/29/2016)

LASER SAFETY BARRIER

APPLIED. OMA-406R Rackmount Process Analyzer

Power Meters Energy Meters

Laser Power and Energy Meters

PM-200 Power Module Operating Instructions

9 W, 15 W and 25 W Industrial Fiber Laser Systems IFL Series

Journal of Applied Science and Agriculture. Improve the Spatial resolution of distributed optical sensors by designing a new detection scheme

Transcription:

This document is downloaded from DR-NTU, Nanyang Technological University Library, Singapore. Title Study of applying fiber based laser with the primary standard for optical power and improvement of spectral responsivity scales in near IR range Author(s) Zhang, Jing; Teo, Jia Jie; Huang, Xuebo Citation Zhang, J., Teo, J. J.,& Huang, X. (2013). Study of applying fiber based laser with the primary standard for optical power and improvement of spectral responsivity scales in near IR range. International Conference on Optics in Precision Engineering and Nanotechnology (icopen2013), Proceedings of SPIE, 87690M1-4. Date 2013 URL http://hdl.handle.net/10220/18589 Rights 2013 SPIE. This paper was published in International Conference on Optics in Precision Engineering and Nanotechnology (icopen2013) and is made available as an electronic reprint (preprint) with permission of SPIE. The paper can be found at the following official DOI: [http://dx.doi.org/10.1117/12.2021600]. One print or electronic copy may be made for personal use only. Systematic or multiple reproduction, distribution to multiple locations via electronic or other means, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper is prohibited and is subject to penalties under law.

Study of Applying Fiber Based Laser with the Primary Standard for Optical Power and Improvement of Spectral Responsivity Scales in Near IR Range Zhang Jing* a, Teo Jia Jie b, Huang Xuebo a a National Metrology Centre (NMC), Agency for Science, Technology and Research (A*STAR) 1 Science Park Drive, Singapore 118221 b School of Electrical and Electronics Engineering, Nanyang Technological University, Singapore 639798 *Email: zhang_jing@nmc.a-star.edu.sg ABSTRACT A fiber optics based 1310nm laser was applied with the primary standard cryogenic radiometer for optical power measurement to extend NMC s spectral responsivity scale toward infrared wavelength. The absolute optical power was measured and two absolute transfer standard detectors (InGaAs based trap detectors) were calibrated at 1310nm. The measurement setup is described and the measurement uncertainty was analyzed. The advantages of using fiber optics based laser sources are discussed in the paper. With the new calibration capability, the uncertainty of the spectral responsivity in the range from 900nm to 1640nm in NMC will be improved. Keywords: Spectral responsivity scale, cryogenic radiometer, infrared wavelength, fiber based laser, trap detector 1. INTRODUCTION The primary standard for optical power is a cryogenic radiometer operating at an absolute temperature of ~13 K, based on thermal equivalence between optical and electrical heating. Combined with a group of intensity stabilised lasers, it is capable of measuring laser power with very low uncertainty. In the past ten years, a krypton ion laser and a He-Ne laser were used for visible and near IR wavelengths (476.2nm to 799.3nm) with the cryogenic radiometer to calibrate the absolute transfer standard detectors for spectral responsivity scales in NMC[1]. Recently, we set up a Ti:Sapphire tunable laser (700nm to 1100nm) and a 1310nm fiber laser with the primary standard for optical power measurement system. With the new setup, the InGaAs trap detector based absolute transfer standard was established at 1310nm. 2. MEASUREMENT OF OPTICAL POWER AND CALIBRATION OF TRAP DETECTORS Figure 1 shows the schematic diagram of the spectral responsivity scale measurement system. The laser was collimated and aligned with the absorbing cavity in cryogenic radiometer. The absolute transfer standards - trap detectors - were installed on a movable stage in front of the cryogenic radiometer. The laser power was measured by the cryogenic radiometer. Then the trap detectors moved in to the optical path and the photo currents generated in the trap detectors were measured. By linking the photo currents and optical powers measured, the responsivities (A/W) of the trap detectors were calculated. 2. 1 Applying fiber optics laser sources with cryogenic radiometer The laser outputs from the krypton ion laser, the He-Ne laser and the Ti:Sapphire tunable laser were in free space. The laser beams were reshaped and high order modes were filtered out by using a space filter with 0.1mm hole. Then the laser beams were collimated and entered the cryogenic radiometer. The fiber based laser in the system takes the advantage of stable and Gaussian-like beam profile (Fig. 2) from the single mode fiber, which has better beam quality than free space laser sources and eliminates the extra components in the system for improving the beam profile. Another advantage of using fiber based laser source is the convenience of changing the laser source and bringing the laser into the optical path through the optical fiber and a collimator. Minor adjustments are needed to fine tune the lenses to achieve the desired optical path and beam position. International Conference on Optics in Precision Engineering and Nanotechnology (icopen2013), edited by Chenggen Quan, Kemao Qian, Anand Asundi, Proc. of SPIE Vol. 8769, 87690M 2013 SPIE CCC code: 0277-786X/13/$18 doi: 10.1117/12.2021600 Proc. of SPIE Vol. 8769 87690M-1

Resistance Bridge Absorbing Cavity Thermal Sensor Reference Block Temperature Controller Absorbing Coating Electrical Heater Scatter Amplifier Std R Current Source Scatter Detector In Vacuum Scanner Brewster Window DVM GPIB bus Trap detectors Laser Shutter Computer Cryogenic radiometer Fig. 1 Schematic structure of NMC s Cryogenic Radiometer Facility Intensity (a.u.) 1500 1000 500 00 5 4 3 X (mm) 2 1 0 0 1 2 3 4 Y (mm) 5 Fig. 2 Beam profile of 1310nm laser. 1310nm Fiber laser Optical Fiber Collimator Polarizer Optical Power Stabilizer Lenses Pupil Detector at position of the trap detector Detector at position of the absorbing cavity in cryogenic radiometer Fig. 3 Laser beam characterization Proc. of SPIE Vol. 8769 87690M-2

Figure 3 shows the laser setup for 1310nm measurement. The 1310nm source was a fiber laser source. We set the output power to be around 5mW at the output APC port. A single mode polarization maintained fiber was used to connect the laser into the optical path. As the laser exiting from a single mode fiber was divergent, a collimator was used to collimate the laser and the beam size was about 1mm diameter. The optical power stabilizer stabilized the fiber laser power output to be around 0.3mW with less than 0.005% fluctuation. The lenses placed after the stabilizer enlarged the collimated laser beam to a size of around 3mm diameter at the position of the trap detector. The pupil in front of the trap detector blocked the scattered light. Controller Monitor PD Laser Polarizer Modulator Beam splitter Fig. 4 Schematic structure of laser power stabilization system 2. 2 The stability of the laser power The schematic structure of optical power stabilizer is shown in Fig. 4. The monitor photodetector detects the optical power and feedbacks to the controller of the optical modulator so that the power fluctuation of the laser can be decreased. In 1310nm laser measurement, the laser power fluctuation was measured to be 0.05% within 1 min period without the optical power stabilizer. With the optical power stabilizer, the laser power fluctuation decreased to <0.005% within 1 min. The power fluctuation within one hour was less than 0.01%. 2. 3 The alignment and scattering measurement A silicon-based quadrant detector in the cryogenic radiometer measures the scattered light in the cavity and assists the alignment of the laser with the cryogenic radiometer at the wavelengths of 1000nm or less. The silicon-based detector has poor response at wavelengths above 1000nm. In order to align the laser at above 1000nm wavelength with the cryogenic radiometer and measure the scattered light, external components are needed. The Physikalisch-Technische Bundesanstalt (PTB) developed a spectral responsivity scale in the spectral range 960nm to 1550nm in 2000 [2]. The measurement of the scattered light was performed outside the cryogenic radiometer, using a germanium (Ge) photodiode and a spherical mirror with a central hole of the same diameter as the hole of the quadrant photodiode in front of the cavity. Similar to PTB s method, we performed the alignment and the scattered light measurement outside the cryogenic radiometer. We used 1000nm laser as the reference beam to do the alignment and then aligned 1310nm laser to the same optical axis. The beam spot size and position of 1310nm were adjusted to be the same as those of the beam at 1000nm. The scattered light was measured with a InGaAs detector out of the cryogenic radiometer. The detector had an active area of 10mm diameter. The photodetector was placed at the position of the trap detector and then at the position of the absorbing cavity in cryogenic radiometer to measure the optical powers, respectively. The difference between the two optical powers was the scattered light. A second pupil was used in front of the detector at the position of the absorbing cavity in cryogenic radiometer to simulate the entrance of the absorbing cavity. By comparing the scattered light measured at the wavelength of 1000nm with the detector outside the cryogenic radiometer and the silicon-based quadrant detector inside the cryogenic radiometer, the size of second pupil was determined. The scattered light at 1310nm was measured to be 0.2% (+/-0.1%) of the total power. The scattered light amount was used to adjust the trap detector calibration result. 2. 4 Trap detectors calibration result The absolute transfer standard - the trap detector - is a reflection type which consists of three single InGaAs photodiodes electrically connected in parallel while oriented in the way that the incoming laser beam is reflected by the surfaces of the photodiodes five times before leaving (Fig. 5). This unique structure minimizes the reflection of incoming laser power. The wavelength of the 1310nm laser source was measured to be 1308.456nm +/- 0.005nm. The optical power was measured with the cryogenic radiometer and two InGaAs trap detectors were calibrated. Table 1 shows the calibration Proc. of SPIE Vol. 8769 87690M-3

results and the trap detectors responsivity after scattered light adjustment. Before doing the scattered light adjustment, the responsivities of trap detector 1 and 2 were 1.0116A/W and 1.0185A/W, respectively. After scattered light adjustment, the responsivity of trap detector 1 at 1308.456nm was 1.0096A/W with the uncertainty of 0.10%, and the responsivity of trap detector 2 at 1308.456nm was 1.0096A/W with the uncertainty of 0.10%. I in I out Fig. 5 diagram of a trap detector Table 1. The spectral responsivities and the measurement uncertainties. Calibration At 1308.456nm Trap Detector 1 Trap Detector 2 Measured Responsivity (A/W) 1.0116 1.0185 Responsivity (A/W) After Scattering Adjustment 1.0096 1.0165 Uncertainty (%) 0.10 0.10 Before we developed the capability of direct calibration with cryogenic radiometer at 1310nm, we calibrated the trap detectors at the wavelengths of up to 799.3nm, and then extrapolated the responsivity up to the wavelength of 900nm. The trap detectors were used to calibrate the secondary standards up to the wavelength of 900nm. The spectral responsivity scale was further expanded by calibrating the secondary standards (Si and InGaAs detectors) through a relative transfer standard - cavity pyroelectric detector (CPD). As the CPD was a spectrally flat detector i.e., its spectral responsivity was independent of wavelength, once calibrated at a specified wavelength, its spectral responsivity values at other wavelengths were all known with 0.25% uncertainty [3]. The calibration uncertainty of the spectral responsivity of the secondary standard in the range from 900nm to 1640nm in NMC was 1.5-1.9%. With the calibration capability available at 1310nm, the spectral responsivity scale of the trap detectors will be used to calibrate the secondary standards (InGaAs photodetector) directly in IR range. Then the secondary standard responsivity scale will be extended to 1640nm by comparing the responsivity between the secondary standard detector and a cavity pyroelectric detector with a flat spectral responsivity within the range. Without calculating the absolute values of the cavity pyroelectric detector, the estimated uncertainty of the spectral responsivity scale in the range from 900nm to 1640nm will be improved from 1.5% to 0.4%. 3. CONCLUSION The absolute transfer standards for optical power measurement at National Metrology Centre (NMC) were directly calibrated at near infrared wavelengths laser by using fiber laser at 1310 nm with cryogenic radiometer. With the new absolute spectral responsivity value at 1310nm, the calibration uncertainty of the spectral responsivity scale in NMC is estimated to be improved greatly in the near infrared wavelength range. REFERENCES 1. Gan Xu and Xuebo Huang, A cryogenic radiometry based spectral responsivity scale at the national metrology centre, International Conference on Optics in Precision Engineering and Nanotechnology 2011, Physics Procedia, Vol. 19, pp. 55 60, (2011). 2. L Werner, R Friedrich, U Johannsen and A Steiger, Precise scale of spectral responsivity for InGaAs detectors based on a cryogenic radiometer and several laser sources, Vol. 37, pp. 523-526 (2000). 3. D H Nettleton, T R Prior and T H Ward, Improved spectral responsivity scales at the NPL, 400 nm to 20 μm, Metrologia, Vol. 30, pp. 425-432, (1993). Proc. of SPIE Vol. 8769 87690M-4