Combustible Dusts What do I do???

Similar documents
AS/NZS :2009 Explosive atmospheres - Part 14: Electrical installations design, selection and erection

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here.

SELECTION, INSTALLATION & TESTING OF ELECTRICAL EQUIPMENTS IN HAZARDOUS AREA

INTRODUCTION TO DUSTS AND THEIR EXPLOSIVE PROPERTIES

NZQA registered unit standard version 1 Page 1 of 5. Install fixed gas detection apparatus in hazardous areas

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Australian/New Zealand Standard

INTERNATIONAL ELECTROTECHNICAL COMMISSION (IEC) SCHEME FOR CERTIFICATION TO STANDARDS RELATING TO EQUIPMENT FOR EXPLOSIVE ATMOSPHERES (IECEx SCHEME)

WHAT WHITE PAPER IS POTENTIALLY EXPLOSIVE ATMOSPHERE CERTIFICATION AND WHY YOU. June 2010

Overview of Hazardous Locations as They Relate to Solenoid Valves

(Notices) NOTICES FROM EUROPEAN UNION INSTITUTIONS, BODIES, OFFICES AND AGENCIES EUROPEAN COMMISSION

Official Journal of the European Union

HazLoc Essential Guides:

(Notices) NOTICES FROM EUROPEAN UNION INSTITUTIONS, BODIES, OFFICES AND AGENCIES EUROPEAN COMMISSION

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2016/C 126/02)

AS/NZS :2014. Electrical equipment for coal mines Introduction, inspection and maintenance AS/NZS :2014. Part 1: For hazardous areas

Matters Needing Attention of Electrical Equipment Installation Engineering in Hazardous Areas. Wang Qiaoli

Dust Explosion Protection Consistent with North American Practice

INTERNATIONAL STANDARD

C 319/6 Official Journal of the European Union

ELECTRICAL EQUIPMENT FOR HAZARDOUS AREAS [EEHA]

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2015/C 335/02)

AS/NZS 4745:2012. Code of practice for handling combustible dusts AS/NZS 4745:2012. Australian/New Zealand Standard. Superseding AS/NZS 4745:2004

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2018/C 092/02)

EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Official Journal of the European Union

AS/NZS :2008

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors

HAZARDOUS AREA CLASSIFICATION AND SELECTION OF EQUIPMENT FOR SAFE USE THEREIN FROM AN ELECTRICAL VIEWPOINT

S T R I T T & P R I E B E I N C.

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Fire Alarm System Accessories

Selection of Explosion Protected Equipment for Hazardous Locations. Compiled by: Pieter Coetzee ZONE 2 ZONE 1 ZONE 0.

UL HAZARDOUS LOCATIONS SERVICES

Intrinsic Safety. Intrinsically Safe Solutions. Accurate Weighing in Hazardous Areas

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

UL Topic III. Converting European EEx Certificates. Into. North American Division Certificates

Understanding. Combustible Dust Hazards: Basic Measures to Ensure the Safety of Combustible Dust Handling Operations

Fire Alarm System Accessories

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

Beamex. Calibration White Paper. Calibration in hazardous areas

First Revision No. 1-NFPA [ Chapter 2 ]

TECHNICAL SPECIFICATION

Beamex Calibration White Paper. Calibration in hazardous areas

Australian/New Zealand Standard

[ TECHNOLOGY ] and does this definition affect a burner.

AS/NZS :2006 Interior and workplace lighting - Part 1: General principles and recommendations

Selecting a Safe Tank Gauging Product. Understanding Hazardous Area Definitions for Equipment Approvals

This document is a preview generated by EVS

Products Solutions Services CT287. Hazardous Area Classifications and Protection Systems

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support

PRIMATECH WHITE PAPER PROCEDURE FOR DUST HAZARD ANALYSIS (DHA)

NZQA registered unit standard version 1 Page 1 of 5. Demonstrate knowledge of electrical installations in special situations

Hazardous Area Classification in Oil & Gas Industry. A Fire Prevention Tool

Aluminum Dust Management in a Metallizing Facility

Apparatus Groups are sometimes referred to, erroneously, as Gas Groups.

Conducting a NFPA 652 Dust Hazard Analysis (DHA): Practical Tips & Approaches

A GUIDE TO EUROPEAN (EEC) CERTIFICATION FOR ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS

Legislation associated with Hazardous Locations. Pieter Coetzee ZONE 2 ZONE 1 ZONE 0. Be safe be Ex

RE: USE OF FIREPRO IN POTENTIALLY EXPLOSIVE ATMOSPHERES

Understanding Hazardous and Explosion-Protection Environments

Guidelines for Market Surveillance of Equipment for Explosive Environments (Hazardous Locations)

Introduction. Program Description. Section C.20 University of South Carolina Safety Program Guide FLAMMABLE AND COMBUSTIBLE LIQUIDS

Explosion-protected actuator Page 259 of 292

Introduction to Hazardous Electrical Location Classifications

Flammable and Combustible Liquids

Numerical Standards Listing

Objectives. NFPA Dust Specific Documents. Combustible Dust Process Hazard Safety Overview of NFPA Standards for Combustible Dusts

- SAFETY MANUAL - DAMPERS

Dust Explosions. health & environmental sciences failure analysis & prevention

Aspects regarding assessment of protection by control of ignition sources at belt conveyors for bulk materials

An Introduction to the IECEx System and IECEx Scheme Certification Processes IECEx Secretariat January 2018

Combustible Dust Booklet

Test procedure/ method name. method identification. Testing of industrial and explosion isolation valves and tank lining

INSTRUCTION & SERVICE MANUAL

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC

TRASCO ATEX Couplings

Australian/New Zealand Standard

HazLoc Essential Guides:

MID-ATLANTIC GEAPS JANUARY 2013 MEETING PRESENTED BY: Johnny Wheat. 4B Components Limited

IECEx Certification of Dust Collection System Assembly. IECEx 2018 International Conference Split, Croatia 23 rd April 2018

ANNEX GD-CERT-EX-EN SIT

IEC TC31 (Explosive Atmospheres) Gas Detection as Method of Protection Jon Miller

Guide for hazardous areas

AS/NZS :2017. Explosive atmospheres AS/NZS :2017. Part 14: Design selection, erection and initial inspection

Implementing a Combustible Dust Program. Presented by: Nick Miedema Amway EH&S For: Michigan Safety Conference

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

Brian Knapp & Johnny Wheat

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

AVOID CATASTROPHIC SITUATIONS: EXPERT FIRE AND GAS CONSULTANCY OPTIMIZES SAFETY

Smoke detection in hazardous areas:

Ex Products Highest level of safety under the most difficult conditions

AS/NZS :2016. Refrigerating systems and heat pumps Safety and environmental requirements AS/NZS :2016. Part 3: Installation site

ABB s ATEX jargon buster explains the terminology users are likely to encounter when purchasing motors for hazardous areas.

August Process Industry Practices Electrical. PIP ELEHA01 Engineering Guide for Determining Electrical Area Classification

Numerical Standards Listing

Transcription:

Combustible Dusts What do I do??? Presented by: Ralph C Wigg

The Past! In the beginning: No standards No verification of apparatus No verification of installations 2

The Past! Then came the standards! Originals were based on British Standards Created our own mix of: British European North America Then Australia & New Zealand developed their own Now Australia/New Zealand have completed the adoption of IEC 3

Where to start? For industries where Combustible Dusts are being handled then the best place to start is with the new Code of Practice. AS/NZS 4745:2004 Code of practice for handling combustible dusts 4

Code of Practice Dust1 5

Code of Practice This Code of Practice is intended to: to assist those industries which may have risks associated with the presence of combustible dusts as part of their processes, in minimizing the risk of injury, death or loss of property to fire and/or explosion through the application of good design and management principles and practices in the construction, operation and maintenance of manufacturing and processing plants and associated transportation and storage systems. 6

Code of Practice It covers: Missing? Philosophy Hazard Assessment Safety Requirements Determining the Presence of Effective Ignition Sources Plant Design Detailed Design & Operational Issues Emergency Management Where is the assessment of the material? How do we know we have a combustible material? 7

Code of Practice To put our subject matter today into perspective it is a part of Detailed Design and Operational Issues and includes: Classification of Hazardous Areas Design and Construction of Equipment, Protective Systems and components based on the avoidance of Ignition Sources

Materials Material characteristics will vary: according to particle size and shape according to moisture content grain may depend on geographical location should be tested but reliable information may be sought but must be used carefully.

Materials Material Data sources: NFPA 499 BIA Report.

Process conditions Is the material being process or just stored? What temperature What pressures Contained Potential for static 11

Process example Blasting What material Sand Metal Particles released from the surface 12

Classification OLD NEW Class II (Australia) Zones 11 & 12 (New Zealand) 3 Zones are now introduced Only part of risk assessment not THE risk assessment 13

Classification Before dealing with Zones the separation of Dust Clouds and Dust Layers must be understood. Dust clouds explode. Dust layers generally burn Dust layers can be a source of a dust cloud. 14

Classification What constitutes a dust layer?

Classification Zone 20 Zone 21 Zone 22 Housekeeping

Classification Material characteristics required for the selection of equipment Dust cloud ignition temperature Dust layer ignition temperature Ignition energy of dust cloud Thermal conductivity Electrical conductivity Introduction of Group III

Classification Situations not covered by the classification standard: Mining Explosives Hybrid mixtures Catastrophic failure Flammable or toxic gas from the dust

Equipment Protection techniques suitable for dusts: Ex t Ex p Ex i Ex m Protection by Enclosure Protection by Pressurization Intrinsic Safety Protection by Encapsulation

Selection Selection according to: Area classification Protection Technique Surface Temperature Conductive or non-conductive dust

Selection Temperature margin for Dust Clouds 2/3 rds Temperature margins for Dust Layers 50K

Inspection & maintenance All inspection and maintenance requirements that apply to Combustible Dusts have transferred from AS 2381.1 to AS/NZS 61241.14/17 and finally to AS/NZS 60079.14/17 Effectively there is no change!

Summary Australia and New Zealand are the first to adopted the IEC standards for Dusts. The major changes are in place and with the 3 zones users can better apply the risk assessment including apparatus selection. The fine tuning has occurred at a rapid rate and we have reached a point of stability where industry can get on with applying these standards with confidence. 23

Aim to avoid!!! 24

THE END