AND ARCHITECT SPECIFICATIONS

Similar documents
AND ARCHITECT SPECIFICATIONS

AND ARCHITECT SPECIFICATIONS

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

Specification/ Data Sheet

Conventional Releasing Control Panel

Addressable Fire Alarm Control Panel

LifeAlarm Fire Alarm Control Panels

AL800ULADA. NAC Power Extender. Installation Guide

Release Control Fire Alarm Systems

MR-2602 Two Zone Fire Alarm Control Panel

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

good things in small packages

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA

CONVENTIONAL FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels MEA. Features. Description

TECHNICAL DATA OBSOLETE

LifeAlarm Fire Alarm Controls

30.45 Electric Release PDRP-2001

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

Fire Safety. Installation Instructions Model SMB-2 Main Control Board OPERATION INSTALLATION

Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

TrueAlert Notification Appliances

Installation Instructions Model HZM

AND ARCHITECT SPECIFICATIONS

ANNUNCIATOR FIXED MODULE

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Air Duct Housings. Description

Advanced Protection System

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

TrueAlert Addressable Notification Appliances

AL600ULADA. NAC Power Extender. Installation Guide

08 Series Notification Appliances AS / AH & AS Audible Strobe Appliances and AH Audibles Application: Indoor / Outdoor

ECC-50/100C. Emergency Command Center

TrueAlert Addressable Notification Appliances

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

AEGIS FEATURES DESCRIPTION. Conventional Fire Alarm-Suppression Control Unit. Effective: March Programmable Relays

AL1042ULADA. NAC Power Extender. Installation Guide (See Application Guide for additional information) Rev

OSU PROJECT NO PAGE 1 02 NOV 2006 SECTION FIRE ALARM SYSTEM

POWERPATH PS-8 (105531) PS-8E (100263) PS-6 (105530) PS-6E (100262)

TrueAlert Addressable Notification Appliances

AL1002ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

Installation Manual CFP-105. Fire Alarm Control Panel. Version 1.0

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

MS Rev. 2/DACT-UD: Intelligent Addressable FACP with Optional 2nd Loop

SP40S-D. Kingfisher Company, inc. Features: Description:

AL1042ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

SECTION FIRE ALARM SYSTEMS

D7024 Fire Alarm Control Panel

XP6-C. Six Circuit Supervised Control Module and SYNC-1 Accessory Card

DS7400Xi Addressable Control/ Communicator

FireSeeker Fire Alarm Control Panel Model FS-250 Installation, Operation and Maintenance Manual

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

TrueAlert Multi-Candela Notification Appliances

TrueAlarm ES Analog Sensing

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

4007ES Fire Control Panels

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS

Remote Booster Power Supplies

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

4007ES Fire Control Panels

July 14, 1999 DF C-100.

Project No Belleville Fire Hall/Headquarters and Emergency Operations Centre Section Belleville, Ontario Page 1 of 10

Doc. No Part No Rev. U * T*

Agent Release Control Panel

PSN-1000 & PSN 1000(E) Installation Manual

Signature Series Auto-Sync Output Module (CC1S)

TrueAlert Addressable Notification

FireSeeker Fire Alarm Control Panel Model FS-100 Installation, Operation, and Maintenance Manual

M O D E L S F I R E G A R D M C V ADVANCE FIRE CONTROL RELEASE DEVICE

SPECIFICATION FOR A TOTAL FLOOD ECARO-25 TM CLEAN AGENT FIRE SUPPRESSION SYSTEM FOR USE WITH THE SHP PRO CONTROL PANEL SYSTEM

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

TrueAlert Addressable Notification Appliances

Commercial and Light Industrial Fire Alarm Control Panel

Model 17A00 Expansion Enclosure

MPC-6000 / MPC-7000 / RND-2

Remote NAC Power Supply D7038

LiftMaster 300 Windsor Drive Oak Brook, IL LiftMaster.com

LDM Series Lamp Driver Modules For Graphic Annunciation and Control

FMR Installation Instructions. Addressable Fire System Controller

Cerberus TM PRO Fire Safety System A comprehensive fire-protection system

Multiple Input and Output Modules

s Notification Appliances

MANUAL RESET ALARM RELEASE BOX

FireNET Series - ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL

FireNET Plus Wiring Instructions

MS-4012/4024 and CMS-4012/4024. Instruction Manual for the. Fire Alarm Control Panels

Mircom FX /01/16

Desigo TM Fire Safety System A comprehensive fire-protection system

Concerns: Affects: Dated: June 12, SECTION 1: GENERAL Scope Work Included... 3

Fire Safety. Installation Instructions. Model ADBX-11. Audible Base INTRODUCTION. Model ADBX-11

Installation Instructions Model ABHW-4S

Installation, Operating and Maintenance Manual

Addressable NAC Output Module D327A

FIREFORCE 8 NOTIFICATION APPLIANCE CIRCUIT EXPANDER INSTALLATION & OPERATION MANUAL

INTELLIGENT FIRE ALARM CONTROL PANEL

Transcription:

SXL Conventional Zone Fire Alarm Control Panel ENGINEER AND ARCHITECT SPECIFICATIONS 4 Zones Expandable to 8 Zones Microprocessor Based Control Factory Programmed Field Configurable 2 Style Y Notification Appliance Circuits Multiple- Option Programmable-Power Limited 3 Amps Notification and Auxiliary Power 24 and 60 Hour Battery Backup Optional Outputs 4 Open Collector, 4 Dry Contact Relays or 8 Dry Contact Relays Subsequent Alarm and Trouble with 24 Hour Reminder Signal Silence Inhibit Sprinkler Supervisory Service Alarm Verification by Zone Alarm, Trouble, Supervisory and Verification Last Event Records One Person Test Drill Function Zone/Output Bypass Remote Annunciator Option 220/240 VAC/50 Hz Power Supply Option Inherently Power Limited per NEC 760 Listed, ULC Listed FM, CSFM and NYMEA Approved Introduction The Cerberus Pyrotronics SXL is another in a family of products designed to provide cost effective, reliable life safety equipment to the fire alarm market. The microprocessor based fire alarm control panel is supplied with four conventional zones and is expandable to eight. It has many features required by today s demanding market such as field programmability, power limited circuits, one person test feature, remote annunciation and sufficient power to meet ADA requirements for signaling. The SXL is designed to meet the varied fire alarm needs of small office buildings, apartment buildings, department stores, hotels, strip malls or anywhere a cost efficient, general purpose fire alarm control panel is required. Additionally, the SXL can be used to supply remote bell power for larger systems such as MXL. Description and Features Initiating Circuits The base SXL has four conventional, Style B (Class B) zones which are typically compatible with the DI-3 ionization detector, the PE-11 photoelectric detector, Cerberus Pyrotronics thermal, flame and beam detectors and the MS Series of manual stations. (Please refer to the detector compatibility list in the wiring diagram for specific compatibility questions). Any combination of 30 compatible smoke detectors can be combined on a zone. Any number of thermal detectors, manual stations or other compatible direct shorting devices may be connected to each zone. All of these initiating devices can be mixed on the same zone providing the total power requirement of the zone does not exceed 9 ma supervisory current. CATALOG NUMBER 7900

The system is expanded through the model SZE-4R expander module which has an additional four initiating circuits in addition to relays and outputs which shall be described later. The system can alternately be expanded through the model SZE-8A expander module which has an additional four Class A (Style D) initiating circuits. The SZE-8A also converts the four initiating circuits and the two notification circuits on the main SXL to Style D (Class A) and Style Z (Class A) respectively. Notification Appliance Circuits The base SXL has two Style Y (Class B) Notification Appliance Circuits, each rated at 1.5 Amps. The total power output of the panel, between the two notification circuits and the auxiliary output, is limited to 3 Amps. The SXL notification circuits are power limited to reduce installation costs without the addition of any hardware. Three (3) Amps is sufficient to provide power for many applications requiring appliances designed to ADA specifications. Notification Circuits can be programmed for various codes. These include temporal, march time, simplified zone code, and number of rounds. They can also be inhibited during test and programming functions. Relays and Outputs The base SXL has form C relays for general alarm and trouble rated at 1 Amp., 30 VDC. The model SZE-4R optional expander module has an additional four general purpose, programmable relays rated at 2 Amps., 30 VDC, plus four programmable open collector outputs. Additionally, the model SRC-8 relay module provides eight general purpose, programmable relays rated at 2 Amps., 30 VDC/120 VAC. All remote operations in the fire alarm system are controlled from the SZE-4R or the SRC-8, both of which are installed within the SXL enclosure. Visual and Audible Indicators The SXL has visible LED annunciation by zone for alarm and trouble. Additionally, there is a system alarm LED and a system trouble LED. Supervisory zones utilize the zone trouble LED flashing in sync with a system supervisory LED to indicate an off normal situation. Clustered with the system alarm, trouble and supervisory LEDs are also LEDs for AC power, bypass and test/ program mode. A seven segment display reports a code for each system trouble and is also used during testing and programming functions. Trouble conditions are also annunciated by a piezo-electric sounder housed inside the SXL. Remote annunciation is accomplished with the model LED-3 or LED-4, eight zone LED annunciators. These units display alarm, supervisory and trouble conditions for 8 zones. A total of two modules can be attached to each system. The LED-3 comes with a black enclosure, the LED-4 with a white enclosure. Auxiliary Power The SXL contains a 1 /2 Amp. auxiliary power circuit which is used to drive remote devices. The total power of the panel, between the auxiliary output and the two notification circuits, is 3 Amps. Power Supply/Battery Charger The power supply accepts a 120 VAC/60 Hz input or, optionally, a 220/240 VAC/50 Hz input. On loss of AC power the system switches to battery operation and indicates such by flashing the AC power LED on the display. Battery capacities of 24 and 60 hours are available. See accompanying chart for model numbers and details. Manual Controls The SXL display has four switches for acknowledging alarm, supervisory and trouble conditions; silencing notification appliance circuits; resetting the system; and for the drill function. These switches are also used when programming the control unit. Field Programmability and Test Functions The following functions are field programmable in the SXL. These features are generally not programmed in the unit as received from the factory. Field programming is accomplished through the display and does not require the use of a computer or any proprietary tools. Initiating Circuits Alarm Verification by Zone, Zone Bypass, Supervisory Zone or Generic Zone when the SXL is to be used to provide remote notification appliance circuits. (Note: The default mode is an alarm causing zone.) Notification Appliance Circuits: Non-silenceable, Simple Zone Coding, March Time, Temporal, California Uniform Fire Code, Silence Inhibit, Cutoff Timers and Reminders. (Note: The default mode is a steady signal.) Outputs: Bypass Outputs/Relays. System Programming: Zone to Output Matrix and Password Maintenance. System tests features include the One Person Test feature, a Lamp Test and Search and Clear of the alarm, trouble and supervisory history buffer. While in the test mode, the system is capable of receiving and initiating alarms except for those zones under test or bypass. Engineer and Architect Specifications The fire alarm control panel shall be a Cerberus Pyrotronics SXL, shall utilize conventional zones, shall be microprocessor based and fully field programmable. The base panel shall include four initiating zones, relays for general alarm and trouble and two power limited notification circuits capable of a total of 3 Amps of power.

The system shall be expandable via a model SZE-4R expander module which shall contain an additional four conventional zones, four general purpose relays and four general purpose open collector outputs. The fire alarm system shall have the following features: subsequent alarm and trouble, one person test feature, brown out protection, 24 or 60 hour battery backup. It shall also have the following selectable features: supervisory zones, alarm verification by zone, non-latching zones, alarm, trouble and supervisory history, notification appliance circuit coding, alarm/trouble 24 hour reminder, and zone/output bypass. The fire alarm control panel shall be UL/ULC listed and meet the requirements of NFPA 72 for local fire alarm control for automatic or manual service, and for sprinkler supervisory and waterflow service. It shall meet NFPA 71 requirements for central station service when connected to the model 5128 or 5129 digital fire communicator. Any initiating device circuit shall have the capability of being mapped to any optional output via the system programming function. Ordering Information Model Number Part Number Description SXL 599-692530 4-Zone Fire Alarm Panel SZE-4R 500-692428 4-Zone Expander Module SZE-8A 500-692971 Class "A" Expander Module SRC-8 500-692972 8 Output Relay Module SLT-1 500-093285 Municipal Tie/Leased Line Module Optional Assemblies SXL-DF 599-892828 SXL-RED 599-192610 SXL/INT 599-692667 4-Zone Fire Alarm Panel w/ Dead Front Construction 4-Zone Fire Alarm Panel w/ Red Enclosure 4-Zone Fire Alarm Panel, 220/240 VAC 50 Hz Accessory Items LED-3 500-693062 Remote Annunciator - Black LED-4 500-693317 Remote Annunciator - White INS-MTR* 500-679620 Meter Module FT-I/SXL 500-692400 Semi-Flush Trim Kit Batteries BT-33 175-387141 6 AH Battery Set BT-34 175-387140 10 AH Battery Set BP-61 175-389194 15 AH Battery Set * These items only for use with SXL-DF and SXL-RED. SXL ship weight is 25 lbs. Note: SXL Operation Installation and Maintenance Manual is P/N 315-092419. See Catalog Number 7901 for SZE-8A. See Catalog Number 7902 for SRC-8. See Catalog Number 7903 for LED-3 and LED-4. See catalog number 7905 for SLT-1.

Dimensional Data SXL with Dead Front Enclosure

SXL Main Board Connection Diagram NOTIFICATION APPLIANCE CIRCUIT Voltage: Supervisory Current: Alarm Current: Each NAC rated at 1.5A, +24 VDC. 24 VDC 1.5mA (max) 1.5A (max) Maximum line impedance per circuit of 3.0 ohms. All NACs are supervised. Each NAC must use at least 14 AWG, 300V insulation, color coded wire. All NACs are power limited per NFPA 70, Article 760 for non-coded applications. FUSE REPLACEMENT F1 8A, AC INPUT F2 2A, NAC 1 F3 F4 15A, BATTERIES 2A, AUX PORT F5 2A, NAC 2 ALARM/TROUBLE RELAY 1.0A at 30 VDC Resistive Only 0.5A at 30 VAC Resistive Only Chime/ Strobes Vibrating Bells Electro-Mech. Horn/Strobes Electronic Horns 1-Tone with Strobe Single Stroke Bells EC-S15-C/F/S EC-S17-C/F/S EC-S75-F/S EC-S110-F/S BE-F/LC BF-F/LC BS-F/LC BT-F/LC HN-S15-C/F/S HN-S17-C/F/S HN-S75-F/S HN-S110-F/S HNH-S15-C/F/S HNH-S17-C/F/S HNH-S75-F/S HNH-S110-F/S EH-S15-C/F/S EH-S17-C/F/S EH-S75-F/S EH-S110-F/S BE-SS BF-SS BS-SS BT-SS Strobes Electronic Horns/ Horns/ Sync. Strobes S.W./Strobes Horn Strobes Horn Strobes 3-Tone 3-Tone S15-F/FS/FT/S/ST EW-S15-C/F/S MC-C/F/S MTL-C/F/S S15S-F/FS/FT/S/ST S17-F/FS/FT/S/ST EW-S17-C/F/S MC-S15-C/F/S MTL-S15-C/F/S S17S-F/FS/FT/S/ST S75-F/FS/FT/S/ST EW-S75-F/S MC-S17-C/F/S MTL-S17-C/F/S S75S-F/FS/FT/S/ST S110-F/FS/FT/S/ST EW-S110-F/S MC-S75-F/S MTL-S75-F/S MC-S110-F/S MTL-S110-F/S Sync. Electro-Mech. Sync. Horns/ Sync. Horns/ Synchronizing Horn/Strobes Horn Strobes Horn Strobes Control Module 3-Tone 8-Tone HN-S15S-C/F/S HNH-S15S-C/F/S MC-S15S-C/F/S MTL-S15S-C/F/S SCM-F/FW HN-S17S-C/F/S HNH-S17S-C/F/S MC-S17S-C/F/S MTL-S17S-C/F/S HN-S75S-F/S HNH-S75S-F/S MC-S75S-F/S MTL-S75S-F/S Electronic Horns Chimes Electronic Electro-Mech. Tri-Tone Horns 1-Tone Slow Whoop Horns EH-C/F/S EC-C/F/S EW-C/F/S HN-C/EP/F/S SEA CH-F/LC/SS HNH-C/EP/F/S TTH Mini-Horns Sync. Mini-Horns/Strobes Sync. Mini-Horns/ Mini-Horns 8-Tone Strobes 8-Tone MH-1G/1GW MHT-1G/1GW MHST-1G/1GW MMT-1G/1GW MMT-S15S-U/UW MH-U/UW MHT-U/UW MHST-U/UW MMT-U/UW MMT-S17S-U/UW MH-S15-U/UW MHT-S15-U/UW MHST-S15S-U/UW MMT-S15-U/UW MMT-S75S-U/UW MH-S17-U/UW MHT-S17-U/UW MHST-S17S-U/UW MMT-S17-U/UW MH-S75-U/UW MHT-S75-U/UW MHST-S75S-U/UW MMT-S75-U/UW MH-S110-U/UW MHT-S110-U/UW MMT-S110-U/UW The SCM-F/FW Synchronizing Control Module must be used with these modules to synchronize the strobes. Bell/Strobe Plate S15-6060H/6090V S17-6060H/6090V S75-6090V S110-6090V Sync. Bell/Strobe Plate S15S-6060H/6090V S17S-6060H/6090V S75S-6090V Suffixes C = Ceiling EP = Explosion Proof F = Flush FT = Flush w/terminals G = Gang Mount H = Horizontal LC = Low Current S = Surface SS = Single Stroke ST = Surface w/terminals U = Universal Mount V = Vertical W = White NOTES: 1. All field wiring must be in accordance with NFPA 70, Article 760. 2. Make no wiring connections while the System is powered. 3. Alarm Relay Contacts are shown de-energized and Trouble Relay Contacts are shown energized. Suitable for resistive load only. 4. Auxiliary output rated 0.5 Amps. at +24 VDC filtered. Maximum line impedance of 5 ohms. 5. Combined current output for NAC1, NAC2 and auxiliary outputs is limited to 3.0 Amps. 6. Equipment connected to these terminals must be located within the same room. 7. Refer to the SXL Operation, Installation, and Maintenance Manual, P/N 315-092419, for further details. 8. No T-tapping allowed. 9. Connect standby batteries only to terminals B+ and B-. The batteries may be installed in either the bottom of the cabinet or in a UL/ULC listed battery enclosure. 10. In all cases the Cerberus Pyrotronics model number is the compatibility identifier, including the control panel, module(s), and all compatible initiating devices.

SZE-4R Connection Diagram Detector COMPATIBLE DETECTORS Quantity per Loop Base Installation Instructions Part No. DI-3/3H 30 DB-3S 315-081943-14 DI-A3/A3H 30 DB-3S 315-081943-14 INITIATING DEVICE CIRCUIT Voltage: Supervisory Current: Alarm Current: 16.4-26.4 VDC 9mA (max) 41mA (max) Maximum line impedance of 25 ohms per IDC zone. All IDC zones are supervised and power limited per NFPA 70, Article 760. Each IDC zone must use at least 18 AWG, 300V insulation, color coded wire for low voltage circuits where local codes require conduit. Where local codes permit, use limited energy shielded cable rated at 300V. Each IDC zone will support one initiating device in alarm. The IDC zone compatibility is an unlimited number of shorting type devices. For smoke detector compatibility, see the Compatible Detectors chart. DI-B3/B3H 30 AD-3I 315-093234-3 DT-3P-135 30 DB-3S 315-084401-5 PBA-1191 1 -- 315-095424 PE-3/3T 30 DB-3S AD-3ILP 315-090875-6 315-093234-3 PE-11 30 DB-11 315-094198-3 SZE-4V FORM C RELAY 2.0A at 30 VDC Resistive Only 0.5A at 30 VAC Resistive Only OPEN COLLECTOR 50mA (max) at 26.4 VDC (max) Cerberus Pyrotronics 8 Ridgedale Avenue Cedar Knolls, NJ 07927 Tel: (201) 267-1300 FAX: (201) 397-7008 Website: www.cerbpyro.com 5/97 10M CPY-IG Printed in U.S.A. Cerberus Pyrotronics 50 East Pearce Street Richmond Hill, Ontario L4B, 1B7 CN Tel: (905) 764-8384 FAX: (905) 731-9182 May 1997 Supersedes sheet dated 2/97