Operating Instructions. Model: LD3 Dual Mode Refrigerant Gas Leak Detector ROBINAIR.COM

Similar documents
Model: LD5 Dual Mode Refrigerant Gas Leak Detector. Operating Instructions

Model: LD7 Dual Mode Refrigerant Gas Leak Detector. Operating Instructions

LD900. User Manual. Refrigerant Gas Leak Detector. Detects all HFO, HFC, HCFC, and CFC Refrigerants including blends. Made in U.S.A.

Model ATD Refrigerant Gas Leak Detector. User Manual. Detects all CFC, HFC, HCFC, HFO Refrigerants including blends

LD-5000 REFRIGERANT LEAK DETECTOR

LD 5000 REFRIGERANT LEAK DETECTOR JB INDUSTRIES INC.

ATD-3698 Refrigerant Gas Leak Detector. Owner s Manual

LD920. User Manual. H2/N2 Tracer Gas Leak Detector. Detects 5% H2 in 95% Nitrogen Tracer Gas. Made in U.S.A. LeakDetectors-LD920-UserManual.

YELLOW JACKET. ACCUPROBE UV and ACCUPROBE II Refrigerant Leak Detector with Heated Sensor. Instruction and Operation Manual

YELLOW JACKET. H 2 Tracer Gas Leak Detector. Operations Manual. Detects 5% H 2 in 95% Nitrogen Tracer Gas. Model 69341

LD910. User Manual. Combustible Gas Leak Detector. Detects all Hydrocarbon and other Combustible Gases. Made in U.S.A. MSHA Approved Intrinsic Safety

OPERATING INSTRUCTIONS

D-TEK Select. Refrigerant Leak Detector

CLI Refrigerant Gas Leak Detector. User s Guide

TEK-Mate. Refrigerant Leak Detector

TEK-Mate. Refrigerant Leak Detector

Model C-380. Instruction Manual. Refrigerant Leak Detector. reedinstruments

99 Washington Street Melrose, MA Phone Toll Free Visit us at

REFRIGERANT LEAK DETECTOR

GAS-Mate. Combustible Gas Leak Detector

actoolsupply.com User Guide Extech RD300 Air Conditioning AC Refrigerant Leak Detector Refrigerant Leakage Detector Model RD300 actoolsupply.

H-10PM. Refrigerant Leak Detector

6-1 Installing Batteries 6-2 Automatic Circuit/Reset Feature 6-3 Feature Sensitivity Adjustment

II 2 G. SENSIT HXG-2d. Ex ib IIB T3 IP20. Suitable for combustible gases such as Methane, Butane, Propane and Natural Gas MADE IN USA

User Manual. Humidity-Temperature Chart Recorder. Model RH520

RLD-H10P Refrigerant Leak Detector

Model 850 Investigator s Aid Accelerant and Gas Detector Operation and Maintenance

Falcon-II Next Generation, Air Quality Monitor CO2 & Temperature

Leak-Seeker I Refrigerant Leak Detector

RLD-H10G Refrigerant Leak Detectors

Instruction Manual Electronic Leak Detector. Bedienungsanleitung Elektronisches Lecksuchgerät. Mode d emploi Détecteur de fuites électronique

SENSIT HXG-2d. SENSIT TECHNOLOGIES 851 Transport Drive Valparaiso, IN Phone: (219) Fax: (219)

Refrigerant Leak Detector

COMBUSTIBLE GAS LEAK DETECTOR PEN

SENSIT HXG-2d Combustible Gas Detector INSTRUCTION MANUAL Read and understand Instructions before use. PENDING Ex. II3G Ex ic llb T3 IP20

SENSIT HXG-2d Combustible Gas Detector

Mold Alert... Operation Manual P0270

RK-05 Carbon Monoxide Detector Operator s Manual

NGD8800 USER S MANUAL

Enspeco RMS. The Enspeco Refrigerant Management. The following instructions will INSTRUCTIONS

GERMANY TEC 'LOGY leak-detect EXPERT

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No , &

Instruction Manual and Warranty

Digital Refrigerator/Freezer Thermometer model 00986

DICKSON KT6 DICKSON. Temperature Chart Recorder. Specifications. Product. Display Symbols. Information & Operating. Contents:

For technical support call:

User's Guide. Pinless Moisture Meter. Model MO257

User's Guide. Pinless Moisture/Humidity Meter with Memory + IR Thermometer. Model MO295

User's Guide. Pinless Moisture/Humidity Meter + IR. Model MO290

III. 99 Washington Street Melrose, MA Phone Toll Free Visit us at OPERATING INSTRUCTIONS

Refrigerant / Combustibles Leak Detector

Model C Electronic Nose Accelerant and Gas Detector Operation and Maintenance

REFRIGERANT LEAK DETECTOR OPERATIONS MANUAL LD-170

Wireless Humidity/ Temperature Monitor Remote Wireless Sensor

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No &

DiscovR R134a Refrigerant Identifier

High Temperature InfraRed Thermometer with Laser Pointer

Instruction Manual. Self-Leveling Rotary Laser Level Model No &

RK-02 Multi Point Detector Operator s Manual

RK Carbon Monoxide Transmitter Operator s Manual

RK/ RK Oxygen Detector Operator s Manual

4-IN-1 PIN/PAD RH MOISTURE METER

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL THL1

RK Multi Point Detector Operator s Manual

RK/ RK Carbon Monoxide Detector Operator s Manual

CALIBRATABLE 3-FUNCTION THERMO- HYGROMETER USER S MANUAL

THL2. Temperature/Humidity USB Datalogger INSTRUCTION MANUAL

Owner s Manual. PIR-1 IR Learner

RK Hydrogen Sulfide Transmitter Operator s Manual

Health Check Ear and Forehead Thermometer Model No.: Instruction Manual

MA11 - Portable Alarm

CALIBRATABLE 7-FUNCTION THERMO- HYGROMETER USER S MANUAL

LV-5 Direct Contact Low Voltage Detector and LV-5/K01 Kit including LV-PT Tester, Holster and Available Accessories

OPERATING MANUAL. The Guardian Hand Held Security Metal Detector

Operator's Manual. LIGHTNING 2 Laser Detector

OPERATING MANUAL. The Guardian Hand Held Security Metal Detector

External Wireless Sounder

OWNERS MANUAL MODEL 451 (-101 & -201)

NEUTRONICS MINI ID R-1234yf REFRIGERANT IDENTIFIER OPERATION MANUAL

DIGITAL STEEL FIRE & SECURITY

CT-7 Series Toxic Gas Transmitter Operator s Manual

Dual Laser InfraRed (IR) Thermometer

This instruction manual explains the use of three models listed on the left.

testo Leakage detector for refrigerants Bedienungsanleitung Instruction manual

Digital Refrigerant System Analyzer. MAXMIN Psi kpa Bar MPa C F R TIME P T UNITS

Savore Electric Pepper Grinder

INSTALLATION AND OPERATING INSTRUCTIONS FOR THE VEHICLE-MOUNTED RADIATION DETECTION SYSTEM

Utopian Portable A/C

Ambient Weather WS-2063 Indoor Temperature and Humidity Monitor with Backlight User Manual

Whynter Portable Ice Maker 33 lb capacity - White

MODEL OX-07 Type A INSTRUCTION MANUAL FOR RIKEN PORTABLE OXYGEN MONITOR PT0E-0860

Danfoss gas detection units

Macurco Single-Gas XL Series Monitor, CM-1XL Carbon Monoxide (CO), HS-1XL Hydrogen Sulfide (H2S) User Instructions

Model K / K. Modelo K / K. Modèle K / K. Operating Manual

AC1234 PRODUCT RANGE.

SAFETY PERSONAL AC VOLTAGE (50 or 60Hz) PROXIMITY DETECTOR

Room Monitor SAVE THIS MANUAL FOR FUTURE REFERENCE.

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

GASGUARD H 2-1% Hydrogen Sensor OPERATING & INSTALLATION MANUAL

Single Gas Clip and SGC Plus User s Manual Rev 2.1 READ FIRST BEFORE OPERATION WARNING STATEMENTS / AVERTISSEMENT Activating tthe detector for the

Transcription:

Operating Instructions Model: LD3 Dual Mode Refrigerant Gas Leak Detector ROBINAIR.COM 800.533.6127

PAGE 2 LD3 OPERATORS MANUAL Contents Introduction... 3 Features... 3 LD3 Control Panel... 4 Operating Instructions... 4 Adjusting Sensitivity Levels... 5 Leak Test Vial... 5 Maintenance... 6 Product Specifications... 7 EN14624/2005 Test Specifications... 7 Cross Sensitivity to Automotive Chemicals... 8 Replacement Parts... 8 Return for Repair Policy & Warranty Policy... 9

LD3 OPERATORS MANUAL PAGE 3 Introduction The LD3 features a long life solid electrolyte semiconductor sensor technology that is designed to detect all CFC, HCFC, HFC, and HFO refrigerants including R-1234F (HFO), R-134A (HFC), R-410A (HFC), R-22 (HCFC), R-407C (HFC), R-507 (HFC), R-12 (CFC), R-404C (HFC). The LD3 is designed to detect all SNAP approved refrigerant blends. The LD3 does not require rechargeable batteries Features Long life, stable sensor R1234yf sensitivity.015 oz/yr R134a sensitivity.05 oz/yr Certified to SAE J2791, J2913, ASHRAE 173-2012, EN14624-2012 Automatic calibration and reset to ambient 3 adjustable sensitivity levels Low battery indicator True mechanical pump Uses 4 AA alkaline batteries CE Certified Comfortable Santoprene handle grip 2-year warranty includes sensor Made in USA

PAGE 4 LD3 OPERATORS MANUAL LD3 Control Panel Sensitivity Level Indicator Green = MED (default) RED = HI, Amber = LO Low Battery indicator when flashing RED ON/OFF Switch Hold down to change Sensitivity when detector is on. Operating Instructions 1. Turn On: Press the ON/OFF button once to turn on and again to turn off. NOTE: For SAE J2913 sensitivity setting for R1234yf Mode hold down ON/OFF button until is the LED turns displays red. 2. Warm Up: The detector automatically starts heating the sensor. During the heating cycle the detector will sound a slow beep and the LED will alternate colors; green, red, yellow. The warm up cycle is complete when the audio beep increases in frequency and the LED turns to constant green (the default sensitivity level). Warm up is usually less than 20 seconds. 3. Search: Move the probe tip towards a suspected refrigerant leak at the rate of less than 2 inches (~50 mm) per second, no more than 1/4 inch (~5 mm) away from the suspected source. 4. Detection: If a leak exists, the sound will increase in rate and pitch. NOTE: The leak detector responds to changes in refrigerant concentration. When detection occurs, move the probe away from the source and back again to confirm the leak source. The detector alarm will reset if the probe is held fixed at the source (see Automatic Calibration Feature).

LD3 OPERATORS MANUAL PAGE 5 Adjusting Sensitivity Levels In addition to the automatic calibration, the audio alarm trigger level can be set by the user to 3 different sensitivity levels- LO (ellow), MED (Green), HI (Red). If the detector is continuously alerting while pulled away from the suspected area of the leak, the sensitivity level can be adjusted so the detector will only alert when the sensor is close to the source of the leak. The Leak Detector will default to the MED (Green) sensitivity level automatically once the unit comes out of the warm up cycle. To change sensitivity levels when the detector is on, press and hold the ON/OFF button down for several seconds. The indicator LED at the top of the keypad will scroll changing colors; Green for MED, Red for HI and ellow for LO. Release the button when the desired sensitivity level is displayed. Leak Test Vial The leak detector comes with a Leak Test Vial that allows the user to verify the detector is performing properly. Check the expiration date on the vial before testing the leak detector. To test: 1. Remove the colored label dot on the center of the screw cap to expose the vent hole. (see fig. below) 2. Turn on the detector and allow the unit to complete the warm up cycle. Set sensitivity level to HIGH. 3. Place the sensor close to the hole in the Leak Test Vial. The beep rate should increase indicating that the sensor and electronics are working properly. NOTE: The leak detector responds to changes in refrigerant concentration. When detection occurs, move the probe away from the source and back again to confirm the leak source. The detector alarm will reset if the probe is held fixed at the source (see Automatic Calibration Feature). Remove label dot over vent hole before testing. Vial Cap with Vent Hole Expiration Date on Label Leak Test Vial

PAGE 6 LD3 OPERATORS MANUAL MAINTENANCE Batteries Install Batteries: Unscrew the battery cover located at the base of the unit as shown. Insert all four batteries into the battery compartment in the same direction. Note the polarity mark on the inside of the battery compartment for proper battery orientation. Replace batteries when the LED Indicator display flashes RED. Sensor & Sensor Filter Replace Filter: Unscrew sensor tip as shown to replace filter. Replace filter when it becomes visible dirty or after 30 hours of usage. Replace Sensor: Remove sensor by pulling it out of the socket. Install the new sensor by aligning the Keyway notch in the sensor cover with the raised keyway on the sensor socket holder (see figure below). Note: Do not force sensor into socket. Misalignment can damage the sensor pins. Unscrew tip to replace filter. Push straight on (do not twist) TO INSTALL sensor. Filter Keyway Alignment Pull straight out (do not twist) TO REMOVE sensor. Important: The instrument s software is designed to alert the user if the sensor is dislodged or defective. If the sensor is not fully inserted into the six-pin socket, or if it is defective, the instrument will not come out of the Warm Up mode for proper operation when the power button is turned on. Additionally, if the instrument becomes unstable during its operation, it is an indication that the sensor may be defective. Note: If the leak detector has been out of use for an extended period, weeks or months, the following action is recommended. Power on the instrument and allow it to come out of warm up, and then run it with the sensitivity level in the (Hi) high position for several minutes before testing it with the Leak Test Vial. This action will guarantee that the sensor is fully conditioned for maximum response to refrigerant gas.

LD3 OPERATORS MANUAL PAGE 7 Product Specifications Model No. LD3 Name Leak Detector, Refrigerant Gas Sensitivity.05 oz/yr R134a,.0123 oz/yr R1234yf Sensor Life > 10 years Response Time Instantaneous Power Supply 4 AA Alkaline batteries Battery Life 4 hours continuous Warm up time < 20 seconds Probe Length 17 inches Weight, lbs 1.5 lbs Warranty 2 years (includes sensor) EN14624/2005 Test Specifications Minimum/Maximum Senitivity Threshold (fixed) Minimum/Maximum Senitivity Threshold (moving) Minimum Detection Time (1gm/yr) Clearing Time Minimum Threshold after Maximum Exposure Sensitivity Threshold in Polluted Atmosphere Calibration Frequency 1 gm/yr minimum, >50 gm/yr maximum 3 gm/yr minimum, >50 gm/yr maximum Approx. 1 second Approx. 9 seconds after exposure to >50 gm/yr 1 gm/yr 1 gm/yr 1/yr check with calibrated leak standard

PAGE 8 LD3 OPERATORS MANUAL Cross Sensitivity to Automotive Chemicals Some automotive solvents and chemicals have similar hydrocarbon properties as R134a and may elicit a positive response. Before leak checking, clean up any chemicals in the list below that elicit a positive response. Chemical Name/Brand Rain-X Windshield Wash Fluid Ford Spot Remover (wet) Ford Rust Inhibitor Ford Gasket Adhesive (wet) Loctite Natural Blue Degreaser (diluted) Ford Brake Parts Cleaner Ford Silicone Rubber (uncured) Motorcraft Antifreeze heated to 160 degrees F Gunk Liquid Wrench Ford Silicone Lubricant Ford Pumice Lotion (with solvent) Ford Motorcraft Brake Fluid Ford Carburetor Cleaner Dextron Transmission Fluid heated to 160 degrees F Quaker State Motor Oil heated to 160 degrees F Response N N (partial) N N N Replacement Parts Item Sensor with Filter Sensor Filters (5 pack) Leak Test Vial Sensor Tip Parts Kit (includes sensor, test vial & filter kit) Carrying Case Part Number F00E901451 F00E901446 F00E901447 F00E901452 F00E901453 F00E901450

LD3 OPERATORS MANUAL PAGE 9 Return for Repair Policy & Warranty Policy Every effort has been made to provide reliable, superior quality products. However, in the event your instrument requires repair, call the Robinair Technical Hotline below for instructions. Robinair warrants the LD3 Refrigerant Gas Leak Detector to be free of defects in materials and workmanship for a period of two years from the date of purchase. Robinair shall, at its option, repair or replace, at no charge, such products which, under normal conditions of use and service, prove to be defective in material and/or workmanship. This warranty applies to all repairable instruments that have not been tampered with or damaged through improper use including unauthorized opening of the unit. Please ship warranty units that require repair freight prepaid to Service Center along with proof of purchase, return address, phone number and/or email address. Robinair shall not be liable for any incidental, consequential, special or punitive damages arising from the sale or use of any products, whether such claim is in contract or not. No attempt to alter, modify or amend this warranty shall be effective unless authorized in writing by an officer of Robinair. THIS WARRANT IS IN LIEU OF ALL OTHER WARRANTIES OR REP- RESENTATIONS, EXPRESS OR IMPLIED, INCLUDING AN WARRANT IMPLIED B LAW, WHETHER FOR MERCHANTABILIT OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE AND SHALL BE EFFECTIVE ONL FOR THE PERIOD THAT THIS EXPRESS WARRANT IS EFFECTIVE. SOME STATES AND JURISDICTIONS DO NOT ALLOW LIMITATIONS ON IMPLIED WARRANTIES, SO THE ABOVE LIMITATIONS MA NOT APPL TO OU. Tech Services: 800-822-5561

PAGE 10 LD3 OPERATORS MANUAL NOTES

LD3 OPERATORS MANUAL PAGE 11 NOTES

655 Eisenhower Drive Owatonna, MN 55060 USA Technical Services: 1-800-822-5561 Fax: 1-866-259-1241 Customer Service: 1-800-533-6127 Fax: 1-800-322-2890 www.robinair.com 581644 REV B Bosch Automotive Service Solutions Inc.