TECHNICAL DATA. Viking Technical Data may be found on Minimum Operating Pressure: Refer to the Approval Chart.

Similar documents
freedom residential horizontal sidewall sprinkler Vk450 (k4.2)

FREEDOM RESIDENTIAL PENDENT SPRINKLER VK468 (K4.9) TECHNICAL DATA

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK460 (K5.8) TECHNICAL DATA

TECHNICAL DATA OBSOLETE

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK486 (K4.0) TECHNICAL DATA

TECHNICAL DATA OBSOLETE

freedom residential horizontal sidewall lead free sprinkler VK4840 (k4.2)

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for C-UL-US-EU Listing requirements that must be followed.

quick response horizontal sidewall sprinkler vk360 (K8.0)

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK479 (K3.0) TECHNICAL DATA

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for C-UL-US-EU Listing requirements that must be followed.

TECHNICAL DATA. Page 1 of 6

freedom residential pendent sprinkler vk466 (K5.2)

FREEDOM RESIDENTIAL PENDENT LEAD FREE SPRINKLER VK4700 (K3.0) TECHNICAL DATA

TECHNICAL DATA 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA

Special Features: For Light Hazard Occupancies Only Designed for Corridor Applications 28 Maximum Width Spacing. 3. technical data

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD TECHNICAL DATA ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)

microfast quick response extended coverage hsw sprinkler vk606

QUICK RESPONSE EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLER VK630 (K8.0) TECHNICAL DATA

quick response extended coverage horizontal sidewall sprinkler vk630 (k8.0)

FREEDOM RESIDENTIAL PENDENT SPRINKLER VK470 (K3.0) TECHNICAL DATA

MicrofastHP EC/QREC FUSIBLE ELEMENT HSW HIGH PRESSURE SPRINKLER VK613 (K5.6) TECHNICAL DATA

TECHNICAL DATA vk470 (K3.0)

ec/qrec ordinary hazard upright and pendent sprinklers vk570 and vk572 (k14.0)

TECHNICAL DATA OBSOLETE

freedom residential concealed pendent Sprinkler vk458 (K7.4)

MICROFAST AND MicrofastHP QUICK RESPONSE PENDENT SPRINKLERS TECHNICAL DATA

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617 TECHNICAL DATA

QUICK RESPONSE FUSIBLE ELEMENT HSW SPRINKLERS VK308 AND HP VK320 (PART NOS AND 13955) TECHNICAL DATA

MICROFAST SR/QR EXTENDED COVERAGE HSW SPRINKLER VK605 (K5.6) TECHNICAL DATA

TECHNICAL DATA OBSOLETE

micromatic Standard response Horizontal Sidewall sprinkler

standard/quick response extended coverage light and ordinary hazard elo sprinklers

EC/QREC ORDINARY HAZARD PENDENT SPRINKLER VK572 (K14.0) TECHNICAL DATA

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)

standard response fusible link sidewall sprinkler VK112 (K5.6)

standard response dry horizontal sidewall sprinklers

Microfast quick response Fusible element hsw sprinkler

TECHNICAL DATA. Refer to Approval Chart 1 and Design Criteria for culus Listing requirements that must be followed.

standard response elo upright and pendent sprinklers (storage-density/area)

Form No. F_ Rev 14.1 Page 1 of 6 TECHNICAL DATA

QUICK RESPONSE EXTENDED COVERAGE CONCEALED HSW SPRINKLER VK630 (K8.0) TECHNICAL DATA

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK457 (K4.9) TECHNICAL DATA

qr fusible element sprinklers (part nos , 13959, 17535, and 17536) 3. technical data Sprinkler 42h March 14, 2013

microfast sr/qr extended coverage pendent sprinkler

STANDARD/QUICK RESPONSE EXTENDED COVERAGE PENDENT SPRINKLER VK602 TECHNICAL DATA

TECHNICAL DATA. Refer to Approval Chart 1 and UL Design Criteria for culus Listing requirements that must be followed.

mirage Quick response concealed pendent sprinkler vk464 (K8.0)

The Viking Corporation s Web site at Rated to 175 psi (12 bar) water working pressure

TECHNICAL DATA STANDARD/QUICK RESPONSE EXTENDED COVERAGE LIGHT HAZARD ELO PENDENT SPRINKLER VK608

QUICK RESPONSE EXTENDED COVERAGE FUSIBLE ELEMENT PENDENT SPRINKLER VK601 (K5.6) TECHNICAL DATA

TECHNICAL DATA. 2. LISTINGS AND APPROVALS culus Listed: Category VNIV FM Approved: Class 2009 NYC Approved: MEA E, Volume 3

MicrofastHP EC/QREC FUSIBLE ELEMENT PENDENT HIGH PRESSURE SPRINKLER VK611 (K5.6) TECHNICAL DATA

mirage Quick response concealed pendent sprinkler vk465 (K4.2)

mirage Quick response extended coverage concealed pendent sprinklers (vk632 and vk634)

MicrofastHP QUICK RESPONSE HORIZONTAL SIDEWALL HIGH PRESSURE SPRINKLER VK319 (K5.6) TECHNICAL DATA

TECHNICAL DATA. Viking Technical Data may be found on Maximum Working Pressure: 175 psi (12 Bar).

MICROFAST QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) TECHNICAL DATA

micromatic Standard response Horizontal Sidewall sprinkler

freedom residential Upright sprinkler vk467 (k4.9)

standard response dry horizontal sidewall sprinklers

standard response sprinklers (vk102 & vk202) 3. technical data Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Sprinkler 11j

microfast and microfasthp quick conventional sprinklers

standard response/qr extended coverage concealed pendent sprinklers vk614 & vk616

quick response Sprinkler 105a October 25, 2010

STANDARD RESPONSE FUSIBLE LINK PENDENT SPRINKLER VK008 (K4.2) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.

microfast quick response Pendent sprinkler VK302 (K5.6)

FREEDOM RESIDENTIAL CONCEALED HORIZONTAL SIDEWALL SPRINKLER VK480 TECHNICAL DATA

mirage standard response concealed pendent sprinkler vk492 (K5.6)

MICROMATIC STANDARD RESPONSE HORIZONTAL SIDEWALL SPRINKLER VK104 (K5.6) TECHNICAL DATA

TECHNICAL DATA. MicrofastHP QUICK RESPONSE FUSIBLE ELEMENT PENDENT HIGH PRESSURE SPRINKLER VK318 (K5.6)

quick response ordinary hazard dry hsw sprinklers (8.0K) (VK275, VK277, & VK279)

STANDARD/QUICK RESPONSE EXTENDED COVERAGE DRY HORIZONTAL SIDEWALL SPRINKLER TECHNICAL DATA

EC/QREC ORDINARY HAZARD UPRIGHT SPRINKLER VK570 (K14.0) TECHNICAL DATA

freedom residential concealed pendent lead free sprinkler

standard response/ quick response extended coverage

STANDARD RESPONSE DRY HORIZONTAL SIDEWALL SPRINKLERS TECHNICAL DATA

micromatic standard response stainless steel sprinklers

Page 1 of 7. Replaces Form No. F_ Rev 16.3 (Added 16X22 and 18X20 coverage areas)

micromatic standard sprinkler VK003 (K2.8) 3. technical data Page 1 of 7

standard response dry horizontal sidewall sprinklers

TECHNICAL DATA. The Viking Corporation s Web site at Frame Casting: Brass UNS-C84400

QUICK RESPONSE ELO PENDENT SPRINKLER VK377 (STORAGE-DENSITY/AREA) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

TECHNICAL DATA. Refer to Approval Chart 1 and FM Design Criteria for FM Approval requirements that must be followed.

STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK537 (K11.2) TECHNICAL DATA

TECHNICAL DATA STANDARD/QUICK RESPONSE EXTENDED COVERAGE PENDENT SPRINKLER VK534 (K11.2)

micromatic standard sprinkler VK004 (K4.2) 3. technical data Page 1 of 6

MICROFAST QUICK RESPONSE PENDENT SPRINKLER VK3311 (K4.2) TECHNICAL DATA

Quick response concealed horizontal sidewall sprinkler VK481

STANDARD/quick. Sprinkler 42o. August 8, 2011

freedom residential concealed pendent sprinkler VK488 (K3.0)

standard response large orifice dry

TECHNICAL DATA. The Viking Corporation s Web site at Overall Length (Sprinkler Body): 2-5/16 (59 mm)

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK468 (K4.9) TECHNICAL DATA

standard/quick response sprinklers (vk302 & vk352) 3. technical data Specifications: Available since Sprinkler 41g May 1, 2009

TECHNICAL DATA. * Metric K-factor measurement shown is in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0.

quick response extra-large orifice upright sprinkler vk531 (storage-density/area)

DRY VERTICAL SIDEWALL SPRINKLERS TECHNICAL DATA

Page 1 of 7. Form No. F_ Rev Replaces Form No. F_ Rev 17.1 (added 205deg version)

Transcription:

April 4, 2008 Sprinkler 143g Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION Viking Freedom Residential Horizontal Sidewall Sprinkler VK452 is a small, thermosensitive, glass-bulb residential sprinkler available in several different finishes and temperature ratings to meet varying design requirements. The orifice design, with a K-Factor of 4.0 (57.7 metric ), allows efficient use of available water supplies for the hydraulically designed fire-protection system. The fast response type glass bulb and special deflector combine speed of operation and area of coverage to meet residential sprinkler standards while being aesthetically pleasing. 2. LISTINGS AND APPROVALS culus Listed: Category VKKW Refer to the Approval Chart on page 143i and Design Criteria on page 143k for culus Listing requirements that must be followed. 3. Specifications: Viking Technical Data may be found on Minimum Operating Pressure: Refer to the Approval Chart. The Viking Corporation s Web site at Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically http://www.vikinggroupinc.com. to 500 psi (34.5 bar). The Web site may include a more recent Testing: U.S.A. Patent No. 4,831,870 edition of this Technical Data Page. Thread size: 1/2 (15 mm) NPT Nominal K-Factor: 4.0 U.S. (57.7 metric ) Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to -65 F (-55 C) Overall Length: 2-7/16 (62 mm) Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Phosphor Bronze UNS-C51000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 Compression Screws: 18-8 Stainless Steel Yoke: Phosphor Bronze UNS-C51000 Ordering Information: (Also refer to the current Viking price list.) Sprinkler: Base Part No. 13140 Order Sprinkler VK452 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome-Enloy = F, and White Polyester = M-/W Temperature Suffix ( F/ C): 155 /68 = B, 175 /79 = D For example, sprinkler VK452 with a Brass finish and a 155 F/68 C temperature rating = Part No. 13140AB. Available Finishes And Temperature Ratings: Refer to Table 1 Accessories: (Also refer to the Sprinkler Accessories section of the Viking data book.) Sprinkler Wrenches: A. Standard Wrench: Part No. 10896W/B (available since 2000) B. Wrench for recessed sprinklers: Part No. 13655W/B* (available since 2006) *A ½ ratchet is required (not available from Viking). Sprinkler Cabinets: A. Six-head capacity: Part No. 01724A (available since 1971) Form No. F_121104 Replaces page 143g-l dated April 6, 2007. (Added G-1 Escutcheon)

Sprinkler 143h April 4, 2008 B. Twelve-head capacity: Part No. 01725A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the yoke, pip cap, and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY The Viking Model VK452 Sprinkler is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking s current list price schedule or contact Viking directly. Sprinkler Temperature Classification TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Nominal Temperature Rating 1 Maximum Ambient Ceiling Temperature 2 Bulb Color Ordinary 155 F (68 C) 100 F (38 C) Red Intermediate 175 F (79 C) 150 F (65 C) Yellow Sprinkler Finishes: Brass, Chrome-Enloy (patents pending), and White Polyester Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. Figure 1: Standard Sprinkler Wrench 10896W/B

April 4, 2008 Sprinker 143i Sprinkler Base Part Number 1 SIN Approval Chart Residential Horizontal Sidewall Sprinkler SIN VK452 For systems designed to NFPA 13D or NFPA 13R. NPT Thread Size Nominal K-Factor Maximum Water Overall Length Inches mm U.S. metric 2 Working Pressure Inches mm 13140 VK452 1/2 15 4.0 57.7 175 psi (12 Bar) 2-7/16 62 Maximum Areas of Coverage 4 Minimum Water Supply Requirements 4 (Refer also to Design Criteria on page 143k.) Listings and Approvals 3 culus 5,6 NYC 7 NSF 8 Installed below smooth, flat, horizontal ceilings, including ceilings with slopes up to and including 2/12 (9.5 ). With the deflector located between 4 and 6 (102 mm and 152 mm) below the ceiling. 12 ft. x 12 ft. (3.7 m x 3.7 m) 11 gpm @ 7.6 psi (41.7 L/min @ 0.52 bar) B1X B1X B1X 12 ft. x 12 ft. (3.7 m x 3.7 m) 12 gpm @ 9 psi (45.5 L/min @ 0.62 bar) C1X C1X C1X 14 ft. x 14 ft. (4.3 m x 4.3 m) 12 gpm @ 9 psi (45.5 L/min @ 0.62 bar) A1X A1X A1X 16 ft. x 16 ft. (4.9 m x 4.9 m) 15 gpm @ 14.1 psi (56.8 L/min @ 0.97 bar) A1X A1X A1X Installed below smooth, flat, horizontal ceilings, including ceilings with slopes up to and including 2/12 (9.5 ). With the deflector located between 6 and 12 (152 mm and 305 mm) below the ceiling. Maximum Areas of Coverage 4 Minimum Water Supply Requirements 4 culus 5,6 NYC 7 NSF 8 12 ft. x 12 ft. (3.7 m x 3.7 m) 12 gpm @ 9 psi (45.5 L/min @ 0.62 bar) A1X A1X A1X 14 ft. x 14 ft. (4.3 m x 4.3 m) 13 gpm @ 10.6 psi (49.3 L/min @ 0.73 bar) A1X A1X A1X 16 ft. x 16 ft. (4.9 m x 4.9 m) 15 gpm @ 14.1 psi (56.8 L/min @ 0.97 bar) A1X A1X A1X Approved Temperature Ratings A - 155 F (68 C) and 175 F (79 C) B - 155 F (68 C) C - 175 F (79 C) Approved Finishes 1 - Brass, Chrome-Enloy, White, and Black 9 Approved Escutcheons X - Standard surface-mounted escutcheons or the Microfast Model F-1 Adjustable Escutcheon 10, or recessed with the Micromatic Model E-1 or E-2 Recessed Escutcheon, or G-1 Adjustable Escutcheon. Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0. 3 This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. 4 For areas of coverage smaller than shown, use the Minimum Water Supply Requirement for the next larger area listed. Flows and pressures listed are per sprinkler. 5 Listed by Underwriter s Laboratories for use in the U.S. and Canada. 6 Listing is for residential occupancies with smooth, flat, horizontal ceilings, including ceilings with slopes up to and including 2/12 (9.5 ). 7 Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 30. 8 Tested and Certified by NSF (National Sanitation Foundation) to NSF/ANSI Standard 61, Drinking Water System Components. 9 Other paint colors are available on request with the same culus Listings as the standard finish colors. 10 The Microfast Model F-1 Adjustable Escutcheon is considered a surface-mounted escutcheon because it does not allow the fusible element of the sprinkler to be recessed behind the face of the wall or ceiling.

Sprinkler 143j April 4, 2008 Figure 2: Wrench 13655W/B for Recessed Sprinkler VK452 culus Listing Requirements: DESIGN CRITERIA (Also refer to the Approval Chart on page 143i.) When using Viking Residential Sprinkler VK452 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of coverage and minimum water supply requirements shown in the Approval Chart on page 143i. For systems designed to NFPA 13: The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: The flow rates given in the Approval Chart on data page 143i for NFPA 13D and NFPA13R applications for each listed area of coverage, or A minimum discharge of 0.1 gpm/ft 2 (4.07 mm/min) over the design area consisting of the four contiguous most hydraulically demanding sprinklers for the coverage areas being protected by the four sprinklers. NOTE: The A S = S x L method must be used to determine the sprinkler protection area of coverage per NFPA 13. Minimum distance between residential sprinklers: 8 ft. (2.4 m). The VK452 horizontal sidewall sprinkler deflector shall be located a minimum of 1-1/4 (31.8 mm) and a maximum of 6 (152 mm) from the wall on which it is installed. DEFLECTOR POSITION: Install sprinkler VK452 with the leading edge of the deflector oriented parallel to the ceiling and the sprinkler frame arms oriented perpendicular to the ceiling (see Figure 4). THE TOP SURFACE OF THE DEFLECTOR IS MARKED TOP. The sprinkler must be oriented as shown in Figure 3 below. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to pages RES1-17 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA and any other similar Authorities Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Final approval and acceptance of all residential sprinkler installations must be obtained from the Authorities Having Jurisdiction.

April 4, 2008 Sprinker 143k Figure 3: Correct Orientation of the Deflector Figure 4: Sprinkler VK452 Dimensions with a Standard Escutcheon and the Model F-1 Adjustable Escutcheon

Sprinkler 143l April 4, 2008 Figure 5: Sprinkler VK452 Dimensions with the Model E-1 and E-2 Recessed Escutcheons Figure 6: Sprinkler VK452 Dimensions with the Model G-1 Escutcheon Form No. F_121104 Replaces page 143g-l dated April 6, 2007. (Added G-1 Escutcheon)