VOLTAGE QUALITY MONITORING IMPACT OF VOLTAGE DISTURBANCES AND THE NEED OF VOLTAGE QUALITY MONITORING

Similar documents
7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management

Microgrid Fault Protection Based on Symmetrical and Differential Current Components

VAMP 120 & 121. Arc flash detection units. Product picture

Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24

ELECTRONIC EQUIPMENT PRODUCTION SPECIALS

Welcome to Hager Presentation

Flame Safeguards LFE10. Building Technologies HVAC Products

Interim Report HORNBACH-BAUMARKT-AG GROUP

Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24..

Electrical Energy department

Soft Starter AC Semiconductor Motor Controller Type RSBS23..A2V.2C24..

1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection

Operating Manual MS220KA and MSR220KA

RAYCHEM MEDIUM VOLTAGE

Distributed Generation (greater than 10kW) Connecting to Vector s electricity network

Cooker Hood LA-72-CAN.

Safety requirements for voltage testing instruments

STCP 02-1 Issue 005 Alarm & Event Management

Flame Safeguards LFE10. Building Technologies HVAC Products

C Note! LGI16... Burner Controls. Building Technologies

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

RAYCHEM SCREENED SEPARABLE CONNECTORS RSTI FOR SWITCHGEARS AND TRANSFORMERS IN MEDIUM VOLTAGE DISTRIBUTION NETWORKS

EMI/RFI Filters. Motor Protection

Half Year Results 2016 Presentation

Table of Contents. Protective Relays

COMPANY PROFILE Electrical & Instrumentation Contractor

NextGen SCADA Europe 2013

Rules for Classification and Construction Additional Rules and Guidelines

POWER SYSTEM INCIDENT REPORT: TRIP OF DOUBLE CIRCUIT MACKAY- COLLINSVILLE TEE - PROSERPINE 132 KV LINES AND STRATHMORE SVC ON 29 DECEMBER 2010

CIRCUIT BREAKER FAIL PROTECTION

DISTRIBUTION OPERATIONS AND MAINTENANCE

Arun Nayar Senior Vice President, Finance and Treasurer

Delta T Alert: Wireless Temperature Monitoring of Electrical Enclosures

Insulation and Protection Enhancing the Reliability of Overhead Power Systems

Varlogic NRC12. Power factor controller. User manual

ST Wiring diagram. Product description. Four-stage controller. Order number

OPTIMISATION OF STEAM AND CONDENSATE SYSTEMS OF PAPER MACHINES

EKL3 short circuit and earth fault indicator

PRESS RELEASE. WACKER Expands Silicones Production in Brazil. Number 12

Operation and use. Functions and characteristics

Corporate Presentation. November 2018

T22 - Arc Flash Hazards and Arc Resistant Equipment- Understanding the Standards

Reliable solutions for electrified railway systems

User Manual 120/240/300 Outdoor Motion Detector

Community Wildfire Safety Program. June 26, 2018

RE-PR3-E-27 3-Phase Panel Mount 27kW

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

TRANSMISSION ENGINEERING STANDARDS SUBSTATIONS

VAMP 120 & 121. Arc Flash Protection Units. Arc Protection. Customer benefits

VAmP 120. Arc Flash Protection Units. Arc Protection. Customer benefits

PART 4 ELECTRICAL STANDARDS

Universal tank control WTS Installation and operating instructions for plant engineering companies

SPECIFICATION FOR GAPLESS METAL OXIDE DISTRIBUTION TYPE SURGE ARRESTERS WITH POLYMERIC HOUSING

TOP R4 Unknown Operating State

Laboratory Honeywell Technology Solutions, Bangalore-EMC Lab, 19/2, Devarabisanahalli Village, K.R. Puram, Varthur Hobli, Bangalore, Karnataka

The Global E-waste Monitor 2017

Major Fault Caused by Stator Winding Circuit Ring Failure

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

Steinhoff International, MARKUS JOOSTE HISTORY AND DEVELOPMENT OF STEINHOFF

ACEO 3D Printing WACKER Plans to Open US Printing Lab for Silicone Rubber at Year End 2018

PRODUCT INFORMATION. Uses tough, high quality PC diffuser, resistant to fracture and to ultraviolet light to limit discolouring.

PRESS RELEASE. Mölnlycke Health Care Honors WACKER as Long-Term Supplier. Number 38

WILDLIFE AND ASSET PROTECTION PRODUCTS

Contents. Preface. Chapter 2 Faults, types and effects The development of simple distribution systems Faults-types and their effects 7

Dow Jones Sustainability Indexes

INTERNATIONAL STANDARD

For personal use only TOUCHCORP 1H2015 RESULTS PRESENTATION DATED: THURSDAY, 27TH AUGUST 2015

PREVENTIVE PROTECTION PROTECCIÓN PREVENTIVA

Constant voltage 3-phase rectifier.

Ordering Key. Dielectric strength

TCM-2 Thyristor Control Module DATA SHEET

CIRCUIT BREAKER - GAS

Monitoring of Electrical Equipment Failure Indicators and Alarming

LineVision TM. Non-Contact Transmission Line Monitoring and Dynamic Line Rating

Requirements for Electrical Installations

Operating Manual MS220DA

PRESS RELEASE. Low-Reflection Liquid Crystal Displays WACKER and VIA optronics Intensify Collaboration in Optical Bonding.

Reyrolle Protection Devices. 7PG26 DAD High Impedance Current Relay. Answers for energy

DRAFT BUSINESS PLAN CEN/TC 133 COPPER AND COPPER ALLOYS EXECUTIVE SUMMARY

Jefferies 2013 Global Technology, Media and Telecom Conference May 8, 2013 New York City, NY

ADVANCED MONITORING AND DIAGNOSTIC SYSTEMS FOR INDUSTRIAL GAS TURBINES

HORNBACH Baumarkt AG Group Q3/9M 2017/2018

INTRODUCTION TAQQAT Global Co. Abdulla Fouad Group

Differential Pressure and Flow Meter Media 5 Indicator 160 PN 40

Principal Brands UK and Northern Ireland

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts

ENV 06. Update Electronics Service Mode and Alarms

Connections, displays and operating elements C D E G H. Installing the control unit

Soft Starter Centrifugal Pump Soft Starter Series

Acquisition Butler Manufacturing Company

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express

» EN50171» Lighting» Reliable

Brown University Revised June 29, 2012 Facilities Design & Construction Standards SECTION ELECTRICAL DESIGN CRITERIA

B&M European Value Retail SA Interim Results Presentation 26 weeks to 23 rd September 2017

BUSINESS PLAN CEN/TC 72 FIRE DETECTION AND FIRE ALARM SYSTEMS EXECUTIVE SUMMARY

SECTION CENTRAL BATTERY INVERTERS. A. This Section includes fast-transfer central battery inverters with the following features:

Networked Access Control Panel. Installation Guide

BENDER A-ISOMETER IRDH265 IRDH365

Operating manual 1 SAFETY REGULATIONS AND INFORMATION. Original operating manual INDEX 2218 F/2TDH4P

TELECOMMUNICATION EQUIPMENT LOCATED IN THE VICINITY OF PROPOSED DISTRIBUTION HV EARTHS

Transcription:

VOLTAGE QUALITY MONITORING IMPACT OF VOLTAGE DISTURBANCES AND THE NEED OF VOLTAGE QUALITY MONITORING Harald Hüwel, Wacker Chemie AG, Electrical Power Supply, 18. November 2009 CREATING TOMORROW'S SOLUTIONS AGENDA. Introduction WACKER Chemie AG Facts of power supply at the Burghausen plant Definition of voltage quality Examples of voltage disturbances Influences on WACKER`s electrical energy supply Need of voltage monitoring Summary Harald Hüwel, Wacker Chemie AG, Electrical Power Supply,18. November 2009, Slide 1 1

AGENDA. Introduction WACKER Chemie AG Facts of power supply at the plant in Burghausen Definition of voltage quality Examples of voltage disturbances Influences on WACKER`s electrical energy supply Need of voltage monitoring Summary Harald Hüwel, Wacker Chemie AG, Electrical Power Supply,18. November 2009, Slide 2 PRODUCTS AND SOLUTIONS FOR KEY GLOBAL SECTORS. WACKER is a technology leader in the chemical and semiconductor industries. We forge ahead with technical innovations and the development of new products for the world s key industries. We offer solutions and innovations for a broad range of sectors. WACKER Group (2008) Sales: 4.30 billion EBITDA: 1.06 billion Net income: 438 million R&D: 163 million Net cash flow: 22 million Investment: 916 million Employees: 15,922 Harald Hüwel, Wacker Chemie AG, Electrical Power Supply,18. November 2009, Slide 3 2

GLOBALLY PRESENT AND CLOSE TO CUSTOMERS: THE WORLD OF WACKER. Harald Hüwel, Wacker Chemie AG, Electrical Power Supply,18. November 2009, Slide 4 PRODUCTION SITES AND COMPANIES: OUR GLOBAL VALUE-CREATION NETWORK. Harald Hüwel, Wacker Chemie AG, Electrical Power Supply,18. November 2009, Slide 5 3

WACKER CHEMIE AG PLANT BURGHAUSEN. WACKER Burghausen is located at the Austria border between Munich and Salzburg. The site was founded in 1914. WACKER employs approx. 10.000 people at the Burghausen plant. Harald Hüwel, Wacker Chemie AG, Electrical Power Supply,18. November 2009, Slide 6 AGENDA. Introduction WACKER Chemie AG Facts of power supply at the Burghausen plant Definition of voltage quality Examples of voltage disturbances Influences on WACKER`s electrical energy supply Need of voltage monitoring Summary Harald Hüwel, Wacker Chemie AG, Electrical Power Supply,18. November 2009, Slide 7 4

HIGHVOLTAGE ENERGY SUPPLY - 110KV. SW = Switchyard 220 kv 220 kv 220 kv SW St. Peter Overheadlines 220 kv SW Altheim SW Pirach 110kV SK124 110 kv 110 kv SW Simbach SW Bruck SW Burghausen Burghausen 110kV SK 135 110kV SK 136 110kV SK 121 110kV SK 125 110kV SK 126 SW Wacker North 110kV LP3504 110kV SK 152 110kV SK 152 Complementary line (normally out of order) Harald Hüwel, Wacker Chemie AG, Electrical Power Supply,18. November 2009, Slide 8 SW Holzfeld 110kV LP186 Cogen Power plant G 10KV GRID SYSTEM OF THE BURGHAUSEN PLANT. 110 kv- Overheadlines SW Pirach/SW Burghausen 110 kv- Cables SW Burghausen 110 kv SW Holzfeld LP 186 110 kv SW Wacker North LP 3504 Cogen Power plant 110 kv 110 kv 110 kv 110 kv T1 T6 T7 T8 T9 T15 10 kv 16 Grids 10 kv Grid S 10 kv 10 kv 10 kv 10 kv 10 kv (ab 2010) 10 kv Grid W Grid D/E Grid A Grid C Grid F Grid G Grid H Grid O G2 G3 G4 G1 G5 DT9 DT8 DT5 Hydroelectric-Powerstation Steam Power plant- - Powerstation SW = Switchyard Harald Hüwel, Wacker Chemie AG, Electrical Power Supply,18. November 2009, Slide 9 5

WACKER CHEMIE AG BURGHAUSEN PLANT ELECTRICAL FACTS. Electrical energy demand (2010) Maximum load Sources of electrical energy in Burghausen: Alzwerke, hydroelectric power plant Cogen power plant Steam power plant Public power grid 2.800 GWh/year 340 MW 40 MW 120 MW 50 MW 130 MW Voltage levels: 110kV, 10kV, 3kV, 690V, 500V, 400V, 230V Electricity is one of WACKER`s main resources and therefore voltage quality is very important. Harald Hüwel, Wacker Chemie AG, Electrical Power Supply,18. November 2009, Slide 10 AGENDA. Introduction WACKER Chemie AG Facts of power supply at the plant in Burghausen Definition of voltage quality Examples of voltage disturbances Influences on WACKER`s electrical energy supply Need of voltage monitoring Summary Harald Hüwel, Wacker Chemie AG, Electrical Power Supply,18. November 2009, Slide 11 6

CHARACTERISTIC NUMBERS OF VOLTAGE QUALITY. EN 50160 Voltage characteristics of electricity supplied by public distribution networks - regards only to voltage levels < 35kV - limits don't fit to industrial needs - is only due to household customers Statistics of national or international agencies - Statistic of VDN regards only to outages > 3 minutes - Flickers, harmonic distortion, short interrupts are not recorded - numbers are not significant to industrial customers This characteristic numbers don't reflect the industrial needs. Harald Hüwel, Wacker Chemie AG, Electrical Power Supply,18. November 2009, Slide 12 REASONS FOR VOLTAGE DISTURBANCES. At the WACKER plant in Burghausen mainly three types of failures may have an impact on voltage quality: Automatic reclosing on overhead lines (short interruptions). Single pole automatic reclosing (e.g. clearing of earth faults) normally don't have impacts to WACKER. Three pole automatic reclosing (necessary by short-circuits) may cause massive voltage interruptions. Short circuits at overhead lines or distribution equipment Harmonic distortions Harald Hüwel, Wacker Chemie AG, Electrical Power Supply,18. November 2009, Slide 13 7

AGENDA. Introduction WACKER Chemie AG Facts of power supply at the plant in Burghausen Definition of voltage quality Examples of voltage disturbances Influences on WACKER`s electrical energy supply Need of voltage monitoring Summary Harald Hüwel, Wacker Chemie AG, Electrical Power Supply,18. November 2009, Slide 14 EXAMPLE 1: SHORT CIRCUIT ON 110KV OVERHEAD LINE. The picture shows a 110kV short circuit in an outdoor switchgear close to WACKER site the voltage dropped from 116 kv to 60 kv interruption lasted 200 milliseconds after the short circuit was cleared by protection units, energy supply was ready for operation again Harald Hüwel, Wacker Chemie AG, Electrical Power Supply,18. November 2009, Slide 15 8

EXAMPLE 1: VOLTAGE AND CURRENT DIAGRAM (10KV). Harald Hüwel, Wacker Chemie AG, Electrical Power Supply,18. November 2009, Slide 16 EXAMPLE 1: IMPACT OF VOLTAGE DISTURBANCE ON 10KV INDUSTRIAL GRID. The diagram shows a voltage dip from 10.2kV to 3.4 kv for about 200 milliseconds Due to the voltage dip about 60% of the load was shut off Financial losses due to: - costs for damaged equipment - additional personnel expenses - reduced production proceeds Harald Hüwel, Wacker Chemie AG, Electrical Power Supply,18. November 2009, Slide 17 9

EXAMPLE 2: SHORT INTERRUPT IN 110KV GRID. Thunderstorm at the Burghausen area One-phase automatic reclosing on phase L1 in one of the overhead lines feeding WACKER Voltage dipped from 114kV to 90,2kV for 150 milliseconds After the failure was cleared by protection units, energy supply was ready for operation again. Harald Hüwel, Wacker Chemie AG, Electrical Power Supply,18. November 2009, Slide 18 EXAMPLE 2: VOLTAGE AND CURRENT DIAGRAM (110KV). Harald Hüwel, Wacker Chemie AG, Electrical Power Supply,18. November 2009, Slide 19 10

EXAMPLE 2: IMPACT OF VOLTAGE DISTURBANCE ON 10KV INDUSTRIAL GRID. In our 10kV grids voltage dropped from 10.2 kv to 6.4 kv for 150 Milliseconds 30% of the load was shut off Financial losses due to: - costs for damaged equipment - additional personnel expenses - reduced production proceeds Harald Hüwel, Wacker Chemie AG, Electrical Power Supply,18. November 2009, Slide 20 EXAMPLE 3: THERMAL OVERLOAD CAUSED BY HARMONICS. In one of our switchgears a current transformer got overheated and caused to an earth fault with a following short circuit. Protection units cleared the arc. Current transformers and switch unit got damaged. The result of the analysis together with the manufacturer of the current transformer showed thermal problems caused by harmonics. Harald Hüwel, Wacker Chemie AG, Electrical Power Supply,18. November 2009, Slide 21 11

EXAMPLE 3: ANALYSES OF HARMONICS. Rising numbers of frequency inverters and thyristor controllers for industrial use are causing a wide variety of harmonics. In combination with capacitances and inductances resonant circuits are possible and may lead to damages. Monitoring and compensation of harmonics may prevent failures in supply grids. Harald Hüwel, Wacker Chemie AG, Electrical Power Supply,18. November 2009, Slide 22 EXAMPLE 3: IMPACT OF VOLTAGE DISTURBANCE ON 10KV INDUSTRIAL GRID. Voltage dropped from 10.2 kv to 8.8 kv for 150 milliseconds. 8 % of the load was shut off Financial losses due to: - costs for damaged equipment - additional personnel expenses - reduced production proceeds Delay in starting new production 3 weeks Harald Hüwel, Wacker Chemie AG, Electrical Power Supply,18. November 2009, Slide 23 12

AGENDA. Introduction WACKER Chemie AG Facts of power supply at the plant in Burghausen Definition of voltage quality Examples of voltage disturbances Influences on WACKER`s electrical energy supply Need of voltage monitoring Summary Harald Hüwel, Wacker Chemie AG, Electrical Power Supply,18. November 2009, Slide 24 STATISTIC OF 110KV AUTOMATIC RECLOSINGS IN 2009 VOLTAGE DIPS IN 10KV GRIDS. Harald Hüwel, Wacker Chemie AG, Electrical Power Supply,18. November 2009, Slide 25 13

STATISTIC OF 110KV AUTOMATIC RECLOSINGS IN 2009 VOLTAGE DIPS IN 10KV GRIDS. In 2009 WACKER recorded 29 voltage dips in the 10kV grid system, which were caused by automatic reclosing on 110kV overhead lines from outside the site. Interruption time in each case was not longer as 150 milliseconds. 10 automatic reclosings had an amplitude of < 95% Uc. 2 of them had negative impacts on WACKER`s power supply. This short interruptions with maximum 150 milliseconds were responsible for facilities shut downs. Harald Hüwel, Wacker Chemie AG, Electrical Power Supply,18. November 2009, Slide 26 STATISTIC OF 110KV SHORT CIRCUITS OR OUTAGES FROM 2007 TO 2009. Harald Hüwel, Wacker Chemie AG, Electrical Power Supply,18. November 2009, Slide 27 14

STATISTIC OF 110KV SHORT CIRCUITS FROM OUTSIDE 2007 TO 2009. Short circuits from outside WACKER: 9 short-circuits occurred in the 110kV supply grid of the energy provider since 2007. 4 of this short interruptions had massive negative influences to WACKER`s energy supply. This short interruptions with a duration of maximum 200 milliseconds were responsible for facilities shut downs. Harald Hüwel, Wacker Chemie AG, Electrical Power Supply,18. November 2009, Slide 28 IMPACTS OF VOLTAGE DISTURBANCES SINCE 2007. Since 2007 we recorded on the feeding 110kV grid: 86 automatic reclosings on overhead lines. 11 of them had massive negative impacts to our energy supply. Reasons were: - Birds (6) - Storm (12) - Unknown (68) 9 short circuits on feeding overhead lines or switch yards. 4 had impacts on WACKER`s energy supply. Reasons were: - operating errors (2) - component failures (4) - unknown (3) The last total black-out happened 30 years ago! Harald Hüwel, Wacker Chemie AG, Electrical Power Supply,18. November 2009, Slide 29 15

AGENDA. Introduction WACKER Chemie AG Facts of power supply at the plant in Burghausen Definition of voltage quality Examples of voltage disturbances Influences on WACKER`s electrical energy supply Need of voltage monitoring Summary Harald Hüwel, Wacker Chemie AG, Electrical Power Supply,18. November 2009, Slide 30 NEED OF VOLTAGE MONITORING. Voltage monitoring by customers offers: - Useful statistic information about reliability of feeding grids - Possibility to make improvements - Better position for discussions with energy suppliers - Cost-savings by more reliable feeding Voltage monitoring by European or state regulators leads to: - Reliable characteristic numbers for power quality - Improvements in supply grids - More efficient and economic power supply Harald Hüwel, Wacker Chemie AG, Electrical Power Supply,18. November 2009, Slide 31 16

INSTRUMENTS FOR POWER VOLTAGE QUALITY MONITORING. For power quality monitoring at the Burghausen site we use a system that continuously controls secondary voltage of each of our fifteen 110 / 10kV transformers. We get information if there is a off-limit condition (voltage, harmonic, frequency, etc.) and we have the possibility to react. Harald Hüwel, Wacker Chemie AG, Electrical Power Supply,18. November 2009, Slide 32 MOBILE POWER QUALITY FACILITY. Field measurements are possible by using a mobile power-quality system. If somewhere in our grids a voltage or harmonic problem occurs will get information about voltage quality derivations. This tool is also necessary for designing new supply grids. Harald Hüwel, Wacker Chemie AG, Electrical Power Supply,18. November 2009, Slide 33 17

AGENDA. Introduction WACKER Chemie AG Facts of power supply at the plant in Burghausen Definition of voltage quality Examples of voltage disturbances Influences on WACKER`s electrical energy supply Need of voltage monitoring Summary Harald Hüwel, Wacker Chemie AG, Electrical Power Supply,18. November 2009, Slide 34 SUMMARY. Voltage quality is very important for the industry. Quality has direct impacts on manufactured products. If the power quality of supply grids is out of limits, for example overvoltage may damage equipments. High financial risks are possible. Industry and energy providers have to work together to achieve a high reliability, high quality and at last, a cost-effective electrical energy supply. Voltage-Monitoring is a necessary tool to reach this goal. Harald Hüwel, Wacker Chemie AG, Electrical Power Supply,18. November 2009, Slide 35 18

THANK YOU FOR YOUR ATTENTION! Harald Hüwel, Wacker Chemie AG, Electrical Power Supply,18. November 2009, Slide 36 BACK-UP. Harald Hüwel, Wacker Chemie AG, Electrical Power Supply,18. November 2009, Slide 37 19

WACKER: HIGHLY INTEGRATED OPERATIONS BASED ON TWO KEY RAW MATERIALS. Harald Hüwel, Wacker Chemie AG, Electrical Power Supply,18. November 2009, Slide 38 VOLTAGE CHARACTERISTICS OF ELECTRICITY SUPPLIED BY PUBLIC DISTRIBUTION NETWORKS DIN EN 50160 FOR MIDDLE- AND LOW VOLTAGE GRIDS <35KV. Frequency Slow Voltage dips 49,5-50,5 Hz (+-1%) during 99,5% in a year Uc +- 10% 95% of the average voltage during 1hour Quick Voltage dips Uc + 6% more times a day Flicker Plt=1 during 95% a week Voltage dips Uc < 90% - 1% for not longer than 1 Sec. Short time Voltage Interruptions Uc <1% for not longer than 3 Min. Longtime Voltage Interruptions Uc <1% for more than 3 Minutes Harald Hüwel, Wacker Chemie AG, Electrical Power Supply,18. November 2009, Slide 39 20

VOLTAGE CHARACTERISTICS OF ELECTRICITY SUPPLIED BY PUBLIC DISTRIBUTION NETWORKS DIN EN 50160 FOR MIDDLE- AND LOWVOLTAGE GRIDS <35KV. Overvoltage with Gridfrequency 1.7 x Uc (Groundet ) Transient Overvoltage Voltage unbalance Voltage Harmonics 2% of 95% of all average metered values a week individual values Most of this values are not suitable for industrial grids! Harald Hüwel, Wacker Chemie AG, Electrical Power Supply,18. November 2009, Slide 40 POWER QUALITY STATISTICS. In reliability statistics, for example from the German VDN, only outages longer than 3 minutes are regarded. This offers a picture, energy supply in transmission grids is high reliable. This may fit to household customers but not to the industry. An voltage dip longer than three minutes may be for industry customers similar to a total black out. For giving characteristic numbers of power supply reliability there have to be regarded all voltage dips below 10% of nominal voltage, even if they last only a few milliseconds. Harald Hüwel, Wacker Chemie AG, Electrical Power Supply,18. November 2009, Slide 41 21