User Manual. Commercial Refrigerator And Freezer User s Manual

Similar documents
Glass Door Merchandisers GDC10, GDC12F, GDC15, GDC23, GDC24F, GDC40, GDC40F, GDS47, GDC69

Narrow Depth Reach-in Refrigerator And Freezer Refrigerator model: 178A19RHC, 178A23RHC, 178A49RHC Freezer model: 178A19FHC, 178A23FHC, 178A49FHC

User Manual. Commercial Refrigerator And Freezer User s Manual

178GDC10HC, 178GDC12FHC, 178GDC15HC, 178GDC23HC, 178GDC24FHC, 178GDC40HC, 178GDC40FHC, 178GDS47HC, 178GDC69HC

User Manual. Glass Countertop Mechandiser Refrigerator. Single Door Model: 360GSM3HCB, 360GSM3HCW Pass-Through Model: 360GSM32HCB, 360GSM32HCW

User Manual

COMMERCIAL REFRIGERATOR AND FREEZER USER S MANUAL

User Manual. Commercial Reach-In Refrigerators: RF-1D, RF-2D, RF-3D. Commercial Reach-In Freezers: FZ-1D, FZ-2D

Vertical Open Air Merchandisers 189BVAC28HC, 189WVAC28HC, 189BVAC36HC, 189WVAC36HC, 189BVAC46HC, 189WVAC46HC,

Outdoor and Indoor Electric Refrigerator Model COAR

Back Bar Refrigerator User s Manual

USER MANUAL. Read this manual thoroughly prior to equipment set-up, operation or maintenance. Model

USER MANUAL. Read manual thoroughly prior to equipment set-up, operation or maintenance. Model Model

User Manual. Commercial School Milk Cooler User s Manual. Commercial School Milk Coolers: MC34, MC49, MC58

User Manual. Commercial Chest Freezer User s Manual 360CF5, 360CF8, 360CF14, 360CF18

178SSPT27HC, 178SSPT36HC, 178SSPT48HC, 178SSPT60HC, 178SSPT71HC, 178SSPT27MHC, 178SSPT36MHC, 178SSPT48MHC, 178SSPT60MHC, 178SSPT71MHC

178SSUC27RHC, 178SSUC27FHC, 178SSUC36RHC, 178SSUC36FHC, 178SSUC48RHC, 178SSUC48FHC, 178SSUC60RHC, 178SSUC60FHC, 178SSUC72RHC

User Manual. Ice Cream Dipping Cabinets 178CPW47HC, 178CPSS47HC, 178CPW68HC, 178CPSS68HC

UNDERCOUNTER REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

GCG-10. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-10-N33EB G-10-N33EB UPRIGHT COOLER

INSTALLATION & OPERATING INSTRUCTIONS MODEL #17900 KEGERATOR MANUAL

G-7s. Instruction Manual. G-Series Cooler COUNTERTOP COOLER. Part No.11IPA

REFRIGERATED PREP TABLES Installation, Operation and Maintenance Instructions

Glass Door Refrigerators

G-10s. Instruction Manual. G-Series Cooler UPRIGHT COOLER. Part No.11IPA

FTM419A01W USER S MANUAL FROST FREE REFRIGERATOR

GCG-9. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-9-N13EB G-9-N13EB GCG-9-B13EB UPRIGHT COOLER

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions

Ui REFRIGERATOR SPEC SHEET

UPRIGHT FREEZER WHS-502FWEW1(E) WHS-502FWEB1(E) WHS-502FWESS1(E)

RCM-77. Instruction Manual. G-Series Cooler. U.S. Patent No. 8,215,125 RECHARGE COLD MERCHANDISER

Glass Door Undercounter and Countertop Freezers

GCG-26c. Instruction Manual. G-Series Cooler

CHEST FREEZER INSTRUCTION MANUAL. Model No.: EWCF5WBX EWCF7WBX

Manual is for the following models: G-26 GCG-26 GCG-26-C31N* G-26-C31N* GCG-26-C231N* GCG-26-CA31N* *G,I,M,7,J plug. Instruction Manual.

Beverage Air IMPORTANT

G-10f/GCG-10f UPRIGHT COOLER

Bar Fridge USER MANUAL MB46W

ref. com Owner s Manual for models: A Step Above the Standard Thank you for choosing EVEREST

INSTRUCTION MANUAL (UNIT APPEARANCE MAY VARY FROM IMAGE) BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

MANUAL. Instructions for installation use & general maintenance of your HORIZONTAL FREEZER HFF, FLORENCIA and MILAN Product Lines MAN-017-R

4.5 CU.FT. REFRIGERATOR INSTRUCTION MANUAL

User s Manual UPRIGHT FREEZER WHS-507FWEW1 / WHS-507FWESS1 WHS-625FWEW1 / WHS-625FWESS1 WHS-772FWEW1 / WHS-772FWESS1

GENERAL LABORATORY REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

RCM-2. Instruction Manual. G-Series Cooler. Manual is for the following models: RCM-2-N13EB. **Patent Pending** RECHARGE COLD MERCHANDISER

3.2 CU FT REFRIGERATOR

Instruction Manual. Chest Freezer. Model: ACFM050ADB INSTALLATION INSTRUCTIONS. Before Using Your Freezer Remove the exterior and interior packing.

OPERATING INSTRUCTIONS

RCM-2. Instruction Manual. G-Series Cooler. Manual is for the following models: RCM-2-N13EB. **Patent Pending** RECHARGE COLD MERCHANDISER

WHYNTER Compressor Cooling Beverage Refrigerator - Stainless Steel

REFRIGERATOR SAFETY. Your safety and the safety of others are very important.

Wine Cabinet Manual. We know you don t want to read through this manual, but trust us, there is good information in here.

REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

BOTTOM MOUNT REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

KELVINATOR C O M M E R C I A L COMMERCIAL FREEZER/REFRIGERATOR REACH-IN REFRIGERATOR AND FREEZER. Refrigerator Model: KCBM23R, KCBM48R, KCBM72R

BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS

User Manual / Installation Instructions

RCM-77. Instruction Manual. G-Series Cooler. Manual is for the following model: RCM-77-N23EB. U.S. Patent No. 8,215,125 RECHARGEABLE COLD MERCHANDISER

For Models FF2310APS, FF2310APW, FF2310APB 55cm FREESTANDING FRIDGE FREEZER. Instruction Manual

POLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL

INSTRUCTION MANUAL COMMERCIAL GRADE KEGERATOR MODEL:XCK-1

ICS PACIFIC. Installation Instructions & User Manual. G135L Medical Refrigerator

1.7 CU.FT. REFRIGERATOR INSTRUCTION MANUAL MCBR170BMD

Installation and Operation Guide For

BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS

INSTRUCTION & USER MANUAL

GS-1. Instruction Manual. G-Series Cooler. Manual is for the following models: GS-1-N14NF GS-1-N14NG GS-1-N14NI COUNTERTOP COOLER

BOTTOM MOUNT REFRIGERATORS & FREEZERS Installation, Operation and Maintenance Instructions

2.4 Cu. Ft. Compact Refrigerator

INSTRUCTION & USER MANUAL

STRUCTURE ILLUSTRATION...3 IMPORTANT SAFETY INSTRUCTIONS 4 INSTALLATION INSTRUCTION..4 OPERATING YOUR REFRIGERATOR...5-6

ICE CREAM TOPPING CABINETS REFRIGERATOR or FREEZER Installation, Operation and Maintenance Instructions

User Manual. Ice Cream Dipping Cabinet User s Manual 360ADC4HC, 360ADC4CHC, 360ADC4FHC

OWNER S MANUAL STAINLESS STEEL REACH-IN SERIES. Model: ATF1 ATF2 ATF3 ATR1 ATR2 ATR3 ATF2 ATR2

Freestanding Wine Cooler Instruction Manual

UDD1, UDD1S, UDD2448, UDD2448S, UDD2460, UDD2460S, UDD2472, UDD2472S

VF X Series. User Manual. SKOPE Vertical Freezer. MAN11137 Rev. 1.1 Sep VF650X

INSTRUCTION MANUAL COMPRESSOR DRIVEN WINE COOLER

HOUSEHOLD FREEZER 048-GM-48303/048-GM-48304/048-GM-48305

Outdoor Refrigerator USER S MANUAL

InstructIon Manual KrEs EQuIPMEnt stands

IMPORTANT PLEASE RETAIN FOR YOUR RECORDS

ICE CREAM DISPLAY MANUAL OF INSTRUCTIONS FOR USE AND INSTALLATION

Model:WHS-109FB1/WHS-109FW1/WHS-109FSS1

Hoshizaki America, Inc.

FELIX STORCH, INC. SUMMIT APPLIANCE DIVISION

Table of Contents. Specifications... page 2. Installation... page 3. Customizing... page 4. Reversing door swing... page 5

MEDICAL FREEZER. Model FS24L INSTRUCTION MANUAL. Write Serial Number (on back of unit) here:

Instruction Manual. Refrigerator. Model: HS-65L

FELIX STORCH, INC. SUMMIT APPLIANCE DIVISION

FELIX STORCH, INC. SUMMIT APPLIANCE DIVISION INSTRUCTION MANUAL FOR MODELS: FS60-FROST

Upright Freezer Congélateur vertical Congelador vertical

RPI Industries, Inc.

G-6c/GCG-6c. Instruction Manual. G-Series Cooler. Manual is for the following models: G-6-C23EB GCG-6-C23EB, G-6-CB23EB, GCG-6-CB23EB BEVERAGE COOLER

Outdoor/Commercial Refrigerator USER S MANUAL

Thank you for buying this refrigerator-freezer. To ensure that you get the best

DOUBLE DOOR COMPACT REFRIGERATOR. User Manual MODEL:KSTRC312BW KSTRC312BB

Installation and User's Manual for Refrigerator Model SCR33

User manual PRO range display chillers and display freezers

REFRIGERATOR-FREEZER

Transcription:

User Manual Commercial Refrigerator And Freezer User s Manual 05/2016 Reach-in Refrigerator And Freezer Refrigerator model: CFD-1RR, CFD-2RR, CFD-3RR Freezer model: CFD-1FF, CFD-2FF, CFD-3FF Glass Door Refrigerator model: CFD-1RRG, CFD-2RRG Please read the manual thoroughly prior to equipment set-up, operation and maintenance. -1-

Installation Please read this manual thoroughly prior to equipment set-up, operation and maintenance. Important!!! Please Read Before Installation If the unit has recently been transported on its side, please let the unit stand upright for a minimum of 24 hours before plugging it in. Make sure the unit has reached the desired temperature before loading the unit with products. Make sure all accessories are installed (shelves, shelf clips, etc ) before plugging in the unit. Do not attempt to remove or repair any component of the unit. Consult an authorized service technician for servicing / repair. Do not hang on doors or stand inside the unit. Please read through this manual in its entirety. Field Convertible Doors The Avantco CFD1RR and CFD1FF both ship with a right-hinged door design. If you would like to convert the reach-in to a left hinged door design (solid door models), you must purchase the left hinges seperately (Avantco item #178CFD1KITFR) and follow these instructions: Tools Needed: Socket Set Pliers Adjustable Wrench Phillips Head Screwdriver 1. Remove the bottom vent, which is held on by loosening the 4 Phillips head screws that hold it on. You do not need to remove the whole way, as the vent will slide up and out. 2. Remove the top panel next. It is held on with 2 small screws. Once the screws are out, the top panel will hinge up. 3. Remove the small Philips head screws at the top and bottom door hinge where it attaches to the brackets. Be careful not to lose the small washers. 4. Next take off the top bracket. It is held on with 3 bolts. 5. The door should come off at this point. - Note: Do not lose the small round brass spacer on the bottom hinge! 6. Remove the bottom bracket. It is held on with 3 bolts. - 2 -

7. Replace the bottom hinge with the new left hand bottom bracket. It is held on with 3 bolts. 8. At this point, you will need to adjust the top and bottom spring tensioners so the door will close properly. 9. Put the door on the bottom hinge on the left side. You will need to reuse the brass spacer from step 5. 10. Next, place the top bracket on the top of the door before bolting it to the unit with the 3 bolts. 11. Replace the small screws on the top and bottom of the bracket and door spring. Make sure the door is on properly before you do this. 12. Reattach the bottom vent and the top panel Cabinet Location Guides Install the unit on a strong and leveled surface. - If the surface is uneven, the unit may be noisy. - The unit may malfunction if the surface is uneven. Install the unit in an indoor, well ventilated area. - For best performance, maintain 6 of clearance on both sides and the back of the unit at all times. - Outdoor use may cause decreased efficiency and damage to the unit. - Avoid direct sunlight. Avoid installation in a high humidity and / or dusty area. - High humidity can cause the unit to rust and may decrease efficiency. - Dust collected on the condenser coil may cause unit to malfunction. - Malfunction due to high ambient temperatures, humidity, or improperly maintained condenser coil will void the warranty. Select a location away from heat and moisture-generating equipment. - High ambient temperatures may cause the compressor to malfunction. - Malfunction due to high ambient temperatures and humidity will void the warranty. - 3 -

Electrical Please ensure that the required voltage is being supplied at all times. The unit should be plugged into a grounded and properly-sized electrical outlet with appropriate over-current protection. Please refer to the electrical requirements on the unit s nameplate. The unit should have its own dedicated outlet. Do not use extension cords. Ensure the unit is not resting on or against the electrical cord. If the unit is not in use for a long period of time, please unplug the unit from the outlet. To avoid shock and fire hazards, do not plug in or unplug the unit with wet hands. After unplugging the unit, wait at least 10 minutes before plugging it back in. Failure to do so could cause damage to the compressor. Adjusting the Temperature Refrigerators are programmed to operate between 33 and 40 degrees Fahrenheit. Freezers are programmed to operate between -10 and +10 degrees Fahrenheit. To set the temperature you would like your unit to run at, follow these instructions: Hold SET for 1 sec. The display will flash the temperature that the refrigerator is currently set to run at. Use the arrow buttons to adjust the temperature you want it to run at. Press SET again to save your settings If the unit consistently runs 5 + degrees higher than your set temperature, service may be needed. Note: All other control functions should be performed by a service technician. Freezer Control Refrigerator Control Prg mute Set aux def set mute - 4 -

Running a Manual Defrost Cycle This unit is pre-programmed to run automatic defrost cycles at preset intervals. However, if you would like to run a manual defrost cycle at any time, please follow the steps below: Freezers: Press the defrost button ( def and down arrow) for approximately 5 seconds. Repeat to stop the defrost cycle. Refrigerators: Press the defrost button (snowflake symbol and down arrow) for approximately 3 seconds. Repeat to stop the defrost cycle. Defrost System Refrigerator coils are kept below the freezing point (32 degrees Fahrenheit). During compressor down-time, the evaporator fan continues to circulate air through the evaporator coil. This air circulation raises the coil temperature above the freezing point, melting any accumulated frost. Run-off water is drained into the evaporator pan and evaporated. Freezer coils are defrosted electrically. Automatic defrost timers automatically initiate at pre-set intervals and for a predetermined duration. Operation/Maintenance NOTE: We strongly recommend that any servicing be performed by an authorized service technician. Loading Product Do not block the air duct / fan at the top of the unit. Maintain a minimum of 4 of clearance between products and the fan at all times. Ensure all shelves are sitting level and properly secured before loading products. Do not store flammable and explosive gas or liquids inside the unit. Cleaning the Condensor Coil For efficient operation, keep the condenser surface free of dust, dirt, and lint. We recommend cleaning the condenser coil at least once per month. Clean the condenser with a commercial condenser coil cleaner, available from any kitchen equipment retailer. Cleaning the Fan Blades and Motor If necessary, clean the fan blades and motor with a soft cloth. If it is necessary to wash the fan blades, cover the fan motor to prevent moisture damage. - 5 -

Cleaning the Interior of Unit When cleaning the cabinet interior, use a solvent of warm water and mild soap. Do not use steel wool, caustic soap, abrasive cleaners, or bleach that may damage the interior finish. Wash door gaskets on a regular basis, preferably weekly. Simply remove the door gasket from the frame of the door, soak it in warm water and soap for thirty (30) minutes, then dry with soft cloth and replace. Check door gaskets for proper seal after they are replaced. Periodically remove the shelves and shelf brackets from the unit, and clean them with a mild soap and warm water. Trouble Shooting Compressor is Not Running Fuse blown or circuit breaker tripped. Power cord unplugged. Thermostat set too high. Cabinet in defrost cycle. Replace fuse or reset circuit breaker. Plug in power cord Set thermostat to lower temperature. Wait for defrost cycle to finish. Cabinet Temperature is too Warm Thermostat is set too high. Airflow is blocked. Low refrigerant levels. Door is slightly ajar. Set thermostat to lower temperature. Re-arrange products to allow for proper air flow. Make sure there is at least four inches of clearance from the fan. Contact a service technician to chek refrigerant levels. Make sure door is completely closed. Interior Light is Not Working Poor switch connection. Bulb is not connected. Bulb has burned out. Turn off light switch and turn it back on. Make sure the bulb is correctly inserted in the socket. Replace the bulb. Condensation is Collecting on the Cabinet and/or Floor Gasket is not sealing properly. Clean, repair, or replace the gasket as necessary. - 6 -

Warranty Information Units in this manual are backed by a 1 year parts and labor warranty, with a 5 year warranty on the compressor. For warranty inquiries or service, first locate: The model number and cabinet serial number (located on the front of the unit, or inside the door jamb). The bold number on the service plate (located on the front of the unit). Next, call 1-800-678-5517. Be sure to have the model number, cabinet serial number, and service plate number available when contacting service technicians. This warranty does not apply to, and Avantco is not responsible for, any warranty claims made on products sold or used outside of the United States. RESIDENTIAL USERS: Avantco assumes no liability for parts or labor coverage for component failure or other damages resulting from installation in non-commercial or residential applications. - 7 -