Design an In-line Monitoring and Testing System Based on PIM Device, CFDS, and Low-cost Mini OTDR

Similar documents
Centralized Monitoring and Self-protected against Fiber Fault in FTTH Access Network

Develop a FTTH Network Management System using Visual Basic

ANALYSIS OF OTDR MEASUREMENT DATA WITH WAVELET TRANSFORM. Hüseyin ACAR *

Computerised Analysis of OFM in Communication Theory

Correlation-based OTDR for in-service monitoring of 64-split TDM PON

Fibre Characterisation and FTTx New challenges

TROUBLESHOOTING AT THE SPEED OF LIGHT EMBEDDED OTDR FOR OPERATIONAL EXCELLENCE IN PASSIVE OPTICAL NETWORKS

Field Testing and Troubleshooting of PON LAN Networks per IEC Jim Davis Regional Marketing Engineer Fluke Networks

Optical Return Loss Measurement by Gregory Lietaert, Product Manager

FTB-730 PON FTTx/MDU OTDR OPTIMIZED FOR ACCESS FIBER DEPLOYMENTS AND TROUBLESHOOTING

FTTH NETWORK TESTING: REAL APPLICATIONS USING THE OLTS METHOD

OTDR - FHO5000-xxx. Optical Time Domain Reflectometer

Design of the Fiber-optic Fence Warning System with Distributed Video Real-Time Display Function Qiang-yi YI and Zheng-hong YU *

VePAL FX300 Fiber Expert OTDR

FLX380-30x FlexTester OTDR

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

palmotdr Series Handheld OTDR

MTTplus Modular Test Platform

A Fresnel Reflection-Based Optical Fiber Sensor System for Remote Refractive Index Measurement Using an OTDR

FLX380 and OFL280 FlexTester Series

Fiber Optic and CAT 5, 6, 7 and 8 Installer Premise Cabling

IEEE COMMUNICATIONS SURVEYS & TUTORIALS, VOL. 15, NO. 2, SECOND QUARTER

palmotdr Series Handheld OTDR

Event dead zone: 0.8 m. Attenuation dead zone: 4 m. Dynamic range: up to 50 db. Platform compatibility. FTB-200 Compact Platform

GAMMA OTDR application consists of main window and menu. Using menu user can operate in different modes of application.

OPTICAL TIME DOMAIN REFLECTOMETRY (OTDR) Dr. BC Choudhary Professor, NITTTR, Chandigarh

FTS500 Series. Handheld OTDR Test Set.

LAN/WAN OTDR FTB-7200 FTTx Access/Metro OTDR FTB-7200/7300 Metro/Long-Haul OTDR FTB-7400/74000 Long-Haul OTDR FTB-7500

Securing optical network physical layer with Fiber Monitoring and Management Vratislav Blažek Regional Sales Manager

Long-Range Displacement Sensor Based on SMS Fiber Structure and OTDR

Optical Fiber Monitor (OFM) Whitebox WB-OFM-1262-DC

LAB REPORT SUBMISSION COVER PAGE ETN4106 OPTOELECTRONICS AND OPTICAL COMMUNICATIONS

Fiber Optics for Todays Industry Applications

Long-distance remote simultaneous measurement of strain and temperature based on a Raman fiber laser with a single FBG embedded in a quartz plate

FTS510 Series. Handheld OTDR Test Set.

iotdr Series Portable OTDR Test Set iotdr Series OTDR Tester is entirely new portable product released by OPWILL.

FACULTY OF ENGINEERING LAB SHEET OPTICAL COMMUNICATION SYSTEMS EOP4066 TRIMESTER 1 (2013/2014)

ACCESS Master MT9085 Series. Product Introduction

High-resolution Photon Counting-OTDR Based Interrogation of Multiplexing Broadband FBG Sensors

Extensive range of models covering all telecom testing applications. Flexible design, allowing up to three wavelengths in a single module

High cost performance choice

OTP6123 Series. Handheld OTDR Test Set.

Hands-On CAT 5/6 & Fiber Optic Installer

OPTICAL TIME DOMAIN REFELECTOMETER (OTDR): PRINCIPLES

OTDR II. Tier-2 Optical Time Domain Reflectometer for Multimode and Single-mode Fiber Cabling

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

Field Test Procedure for Optical Fibre Link Measurements

High cost performance choice

GO BEYOND OTDR LEAVE NO FAULTY NETWORK BEHIND. intelligent Optical Link Mapper

Omnisens DITEST TM FIBER OPTIC DISTRIBUTED TEMPERATURE & STRAIN SENSING TECHNIQUE

The Rise of Tier 2 Testing

The Definitive Handheld OTDR for FTTx Testing OTDR AXS Compact, lightweight handheld OTDR optimized for access/fttx network testing

Passive Optical Network Monitoring: Challenges and Requirements

Essentials of Fiber to the Antenna: Fronthaul Installation Test

Intelligent Optical Link Mapper (iolm)

Remote fiber testing to improve SLA s

Noyes OFL 250B Specs Provided by

Hands-On Fiber Optics ISP/OSP - Advanced Combo- Tech

M210 Multifunction Micro OTDR

FHO5000 Series Triple-Proof OTDR

GRANDWAY FHO5000 series OTDR

FG-750 Client API SDN-READY INTELLIGENT OTDR

FastReporter 2 DATA POST-PROCESSING SOFTWARE

FTB-720 LAN/WAN Access OTDR OPTIMIZED FOR MULTIMODE AND SINGLEMODE ACCESS NETWORK TESTING

FTB-700 Series. OTDR for FTB-1. User Guide

Ensuring the Health of Tomorrow s Fiber LANs Part II OTDR Trace Analysis Become an Expert Troubleshooter with Advanced OTDR Trace Analysis

Architectural and Engineering Specification for a Fiber Optic Perimeter Intrusion Detection System. FiberPatrol FP1150

SmartClass and SmartPocket Optical Handhelds. Portfolio of Optical Handhelds for Fiber Field Test

FTB-7400E Metro/CWDM OTDR METRO/CORE AND CWDM NETWORK FIBER CHARACTERIZATION

Yokogawa Meters & Instruments Releases AQ1200E, AQ1205A, AQ1205E, and AQ1205F OTDR Multi Field Testers

M210 Multifunction Micro OTDR

OTDR. Optical Time Domain Reflectometer. User Guide

FTB/FTBx-740C-CWDM Tunable OTDR 18-WAVELENGTH CWDM OTDR FOR METRO ETHERNET AND C-RAN LINK CHARACTERIZATION

PC474 Lab Manual Wilfrid Laurier University 1

TECHNICAL - *All Pricing are Exclusive of VAT. Introduction to Fibre Optics for non-fibre Technicians (can also be done on-site) TARGET AUDIENCE:

PC474 Lab Manual 1. Terry Sturtevanta and Hasan Shodiev 2. Winter 2012

Erbium-Doped Fiber Amplifier (EDFA) - MW Series

Refurbished EXFO Instruments

FOT-930 MaxTester MULTIFUNCTION LOSS TESTER

Fiber Guardian. Fiber Guardian. Where fiber monitoring starts. Key Features

A dvan ced Fib er Opt ic Test Eq u ip me nt Terahertz Technologies Inc.

FTB-735C Metro/PON FTTx/MDU OTDR

OBL-301A. Optical Break Locator. Operation Guide

FTBx-740C-DWC TUNABLE OTDR C-BAND DWDM METRO ETHERNET LINK CHARACTERIZATION

FLX380-30x FlexTester3 OTDR

Journal of Applied Science and Agriculture. Improve the Spatial resolution of distributed optical sensors by designing a new detection scheme

DWDM OTDR with Tunable Laser MTP-200-D100. Hand-held High Performance OTDR. Series

Fibre (TIA) Field Test Specification

FiberSystem. Fiber Optic Linear Heat Detection for Special Hazard Applications

M700-Series Multifunction OTDR

Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team

A. General: Horizontal and backbone cabling shall be verified in accordance with ANSI/TIA/EIA-568-C and the addendum for fiber optic testing.

Architectural and Engineering Specification for a Fiber Optic Perimeter Intrusion Detection System. FiberPatrol FP1100X

Terahertz Technologies Inc Fiber Optic Test Equipment Catalog

WHITE PAPER FIBER OPTIC SENSING. Summary. Index. Introduction. About Fischer Connectors

Operations Manual TS400. Test Station for G450/G460 Gas Detector

OPTICAL TIME-DOMAIN REFLECTOMETER

Product Specification

Construction of Wireless Fire Alarm System Based on ZigBee Technology

MINI2. Inno Mini 2 Specs Provided by MOST ACCURATE COMPACT OTDR

Transcription:

Australian Journal of Basic and Applied Sciences, 3(4): 3361-3373, 2009 ISSN 1991-8178 Design an In-line Monitoring and Testing System Based on PIM Device, CFDS, and Low-cost Mini OTDR Mohammad Syuhaimi Ab-Rahman and Boonchuan Ng Spectrum Technology Research Division, Computer & Network Security Research Group, Faculty of Engineering & Built Environment, Department of Electrical, Electronic and Systems Engineering, University Kebangsaan Malaysia, 43600 ukm Bangi, Selangor, Malaysia Abstract: We proposed and experimentally demonstrated a new in-line monitoring and testing system with the combination of Passive In-line Monitoring (PIM) device and Centralized Failure Detection System (CFDS) for transmission surveillance and failure detection without affecting the triple-play service delivery in fiber-to-the-home (FTTH) access network. PIM device is a fully passive device used for optical signals tapping purposes, meanwhile CFDS is a centralized monitoring and troubleshooting solution with graphical user interface (GUI) processing capabilities in MATLAB. Any fiber fault occurs in the network will be determined by CFDS, while the PIM device is used to determine sharply the failure point before taking some appropriate actions. This approach has a bright prospect to improve the survivability and reliability as well as increase the efficiency and monitoring capabilities in an optical access network. Key words: In-line monitoring, testing system, PIM, CFDS, OTDR INTRODUCTION FTTH is a network technology whereby triple-play can be delivered to residential and business customers using optical fiber cables from the point of origination to the home. The point of origination is called as central office (CO) in telephone industry and head end or hub in cable television (CATV) industry (Farmer and Bourg, 2008). A number of factors are increasing the interest among network service providers in offering the triple play services of voice, video, and high-speed data access. Most importantly, subscribers are finding a growing number of applications that drive their desire for higher bandwidth, including Internet access, interactive games, and video delivery. The first serious interest in FTTH began in the late 1980s as the telephone companies gained experience with Integrated Services Digital Network (ISDN) wideband services to subscribers. Today, FTTH has been recognized as the ultimate solution for providing various communications and multimedia services, including carrier-class telephony, high-speed Internet access, digital cable television (CATV), and interactive two-way video-based services to the end users (Lee et al., 2006). FTTH technology using passive optical network (PON) is the most promising way to provide high quality broadband access. PON are nowadays extensively studied and some commercial deployments are already reported (Wuilpart et al., 2007). The PON is commonly deployed as it can offer a cost-efficient and scalable solution to provide huge-capacity optical access. PON using a shared optical fiber cables from CO to deep in the network and usually terminates at a splitter cabinet (Hutcheson, 2008). The optical fiber offers a vast amount of bandwidth that can be utilized for communication. One of utilizing this is signal multiplexing. Due to the large bandwidth and the associated high bit rates, the multiplexing process is beyond the capabilities of pure electronic methods and has to be implemented optically as well (Menif and Fathallah, 2007). One important technique is time division multiplexing (TDM), where two or more signals or bit streams are transferred apparently simultaneously as sub-channels in one communication channel, but are physically taking turns on the channel (Abbou et al., 2007; Cai et al., 2002). Nowadays, TDM-PONs are commonly deployed as they can offer a cost-efficient and scalable solution to provide huge-capacity optical access. A TDM-PON is a shared medium where the optical fiber is passively Corresponding Author: Mohammad Syuhaimi Ab-Rahman, Spectrum Technology Research Division, Computer & Network Security Research Group, Faculty of Engineering & Built Environment, University Kebangsaan Malaysia, 43600 ukm Bangi, Selangor, Malaysia E-mail: syuhaimi@vlsi.eng.ukm.my 3361

split, through a branched tree topology, to several end users. A passive optical 1:N (where N = 2, 4, 8, 16, 32, 64 or 128) power splitter is required in a remote node (RN) on the fiber path between the CO and end users. Since the signal is passively split, no electrical power is required in the field. Fiber Fault Localization: Since the PON can accommodate a large number of subscribers, when any fault occurs in an optical fiber line, the access network will without any function behind the break point. Any service outage due to a fiber break can be translated into tremendous financial loss in business for the service providers (Chan et al., 1999). A failure due to fiber break in current optical communication system could make the network service providers very difficult to restore the system back to normal. According to the cases reported to the Federal Communication Commission (FCC), more than one-third of service disruptions are due to fiber cable problems. These kinds of problems usually take longer time to resolve compared to the transmission equipment failure (Bakar et al., 2007). Conventionally, optical time domain reflectometer (OTDR) is used to identify a fiber fault in FTTH upwardly from ONU toward CO (in upstream direction). Whenever a fault occurs, technician is sent to the ONU side to inject an OTDR pulse into the faulty fiber. By means of OTDR, one can get the distance from the fault site to the measurement site along the optical fiber housed in the optical cable (Lu et al., 2006). OTDR testing is the best method for determining the exact location of broken optical fiber in an installed optical fiber cable when the cable jacket is not visibly damaged. It determines the loss due to individual splice, connector or other single point anomalies installed in a system. It also provides the best representation of overall fiber integrity (Chomycz, 1996). However, this approach would require much time and effort. Moreover, OTDR can only display a measurement result of a line in a time. Therefore, it becomes a hindrance to detect a faulty fiber with a large number of subscribers and large coverage area in the fiber plant by using an OTDR. Besides, it is difficult to detect a failure in optical line equipped with passive optical splitter by using a conventional OTDR in the CO downwardly from CO (in downstream direction) because the Rayleigh back-scattered (RBS) light from different branches overlap (accumulate) with each other in the OTDR trace and cannot be distinguished (Chan et al., 1999). Some researchers had discussed about the monitoring issues with OTDR and recommended a number of possible methods to overcome these problems to achieve desired network survivability such as Centralized Optical Monitoring using a Raman-assisted OTDR (proposed by K. Yuksel 2007) or OTDR-based testing system using reference reflectors or fiber selectors (proposed by N. Tomita 1991).Caviglia and Biase, (1998). The faulty fiber can be monitored without affecting other in-service channels. However, these methods need relatively expensive additional sources or devices that impose high-maintenance cost. Therefore, improving network reliability performance by adding redundant components and systems have shortcomings in terms of implementation cost and flexibility. In-line Monitoring and Testing System: To overcome these problems to achieve desired network survivability, we introduced a transmission surveillance scheme with the combination of PIM device and CFDS for in-service monitoring and failure analyzing. PIM Device: The PIM device is a totally passive device capable of tapping optical signals. It has no active electronic components and therefore does not need any electrical supply for their operation. It is purposely developed for monitoring the three main operating wavelengths (optical signals; 1310 nm, 1480 nm, and 1550 nm) which associated with FTTH. The 1480 nm (or 1490 nm) downstream signal and 1310 nm upstream signal are used for data and voice transmission. The 1550 nm downstream signal is used for analog video overlay. The device is consists of four ports for tapping function, as shown in Fig. 1 and 2, which are controlled by optical couplers (i.e.: directional couplers or wavelength division multiplexing (WDM) couplers) to perform the optical power combining and splitting in the device. The upstream or downstream signals from the FTTH trunk line will be entering the taper circuit. This device provides a visual way of monitoring the receiving signal performance, when connected to a small television (TV) screen which the user can view the broadcast channel of CATV video or personnel digital assistant (PDA) for data communication. It taps out a small ratio of these signals in order to monitor the status along the main line without affecting both upstream and downstream transmission. 3362

Fig. 1: Photographic view of the developed PIM device prototype. Fig.2: The block diagram for PIM device CFDS: CFDS is a MATLAB-based Gui that enhances the network service providers with a means of viewing traffic flow and detecting breakdowns as well as other circumstances which may require some action. CFDS is interfaced with OTDR to accumulate every network testing result to be displayed on a computer screen for further analysis (in Line s Status window). It used event identification method to differentiate the mechanism of the optical signal at working (good/ideal) and non-working (failure/breakdown) condition. CFDS displays a Good condition or Decreasing y db at z km message at the line's status panel in Line s Detail window in a working condition (see Fig. 4), else a failure message Line x FAILURE at z km from CO! displays in the non-working condition as illustrated in Fig. 5 Further detail will be displayed in the Line s Detail window (as shown in Fig. 4) when click at the individual line in the combo box. The developed program is able to identify and present the parameters of optical line such as status, magnitude of decreasing, failure location, and other details as shown in the OTDR s screen. CFDS has the same features of the OTDR and computer-based emulation software for performing more OTDR trace processing functions, but with more additional features and flexible to use in optical communication link especially in FTTH. CFDS is potentially to improve the survivability and increase the monitoring capabilities in tree-structured FTTH as well as overcoming the upwardly or downwardly monitoring issues with conventional fiber fault localization technique by using OTDR. Overall, it can reduce the time needed to restore the fiber fault to maintain and operate the FTTH more efficiently. Experimental Setup and Network Testing: The PIM device prototype has three important parameters to check: insertion loss, return loss, and directionality. The most important parameter of PIM device prototype is insertion loss. The difference in signal level between the input and output is the insertion loss. The insertion loss of a PIM device prototype should be quite small, typically about 1.5 db. The parameters of insertion loss at each port in the PIM device prototype is study through a network testing, which used a low-cost commercially available OTDR such as EXFO FTB-100B mini OTDR for 3363

examining the optical signal level. Four tests are conduct via different input ports and output ports with different tapped ratio. We indicate the percentage division of optical power between the output ports of optical couplers by means of the splitting ratio or coupling ratio by adjusting the parameters. The experimental setups for each test are summarized in Fig. 3. Computer Interface and Data Transfer: The measurement for each test is saved in OTDR as trace (TRC) file and then transferred into computer by using EXFO ToolBox Office PC Emulation software such as ToolBox 6 for data post-processing through serial connection on OTDR and computer with the serial port extension cable (RS232) as depicts in Fig. 4. On the OTDR, select Utilities File manager click the Location button under Available files highlight the folder where the files are click Ok. Then all available files in the left window, transfer the files you want to the right window. Click Copy on the bottom of the files manager screen and select the copy location to User files/out, then click Ok. Once the copies are done, go to the computer and activate the data transfer application in the ToolBox 6 software by selecting Utilities Tool Data transfer (Fig. 5) PC(FTB) to FTB-100 (Fig. 6), then choose the COM port, Storage folder, Replace automatically and click Next (Fig. 7). Once you are in the transfer window, click Transfer immediately (Fig. 8), the application will take the files from the User files/out folder on the FTB-100B and transfer them to the computer (Fig. 9 and 10). When this is done, you may open your files with the appropriate application. Open the file with ToolBox 6 by selecting Work on results (offline) OTDR OTDR (Fig. 11) Open (Fig. 12), choose the file name and file location at path, then click Ok (Fig.13). Now you can analyses the results and make any changes. The result can be saved in American Standard Code for Information Interchange (ASCII) form (Fig. 14 and 15) (EXFO, 2000). Fig. 3: Experimental setup block diagram for network testing Fig. 4: Interface between OTDR and computer 3364

Fig. 5: Select Utilities Tool Data transfer Fig. 6: Select PC(FTB) to FTB-100 Fig. 7: Choose the COM port, Storage folder, Replace automatically and click Next 3365

Fig. 8: Click Transfer Fig. 9: Transferring files from the User files/out folder on the FTB-100 to the computer Fig. 10: Transferring files are success, click Exit 3366

Fig. 11: Select Work on results (offline) OTDR OTDR Fig. 12: Select Open Fig. 13: Choose the file name and file location at path, then click Ok 3367

Fig. 14: Click Save Fig.15: Select save as ASCII file and click Ok Data Analyzing with EXFO ToolBox 6: The first, second and fourth network tests are the application under working condition (see Fig. 16, 17, and 19), however the third network test is the application under non-working condition because the optical signal was terminated at distance 15.2632 km (see Fig. 18). The insertion loss (expressed in db) is calculated by measuring the optical signal level reduction in RBS that caused by both reflective and non-reflective events. Total loss in network is the sum of losses in PIM device, 15 km and 20 km optical fibers. Data Analyzing with CFDS: The network testing results also can be analyzed in CFDS. The developed program may be executed by simply selecting (i.e. double clicking) the Launch.fig or its shortcut icon. CFDS opens the Line s Status window that presents the user with several options. As a first step, the users can select the Open at the left bottom in Line s Status window, all the results are load from database into MATLAB Current Directory. Every eight graphs that represent the characteristics of optical lines displayed in Line s Status window for centralized monitoring as depicted in Fig. 20, where the distance (km) represented on the x-axis and attenuation (db) represented on the y-axis. CFDS is focusing on providing survivability through event identification against losses and failures. CFDS used event identification to differentiate the mechanism of the optical signal at working and non-working condition. The user may continue to press the Status button to execute the optical line s status analyzing process. In Fig. 20, a failure message Line 4 FAILURE at 15.2582 km from CO! displayed to show the exact failure location in the network. 3368

Fig. 16: Trace display and event table for first network test via port B-A with 100% ë 2 signal Fig. 17: Trace display and event table for second network test via port D-A with 100% ë 2 signal Further detail will be displayed in the Line s Detail window when click at the individual line in the combo box. A Decreasing y db at z km message displays (see Fig. 21, 22 and 24) to show the insertion loss of the PIM device prototype in a working condition. However in the non-working condition, a failure message Line 4 FAILURE at 15.2582 km from CO! displays as shown in Fig. 24. 3369

Fig. 18: Trace display and event table for third network test via port A-C with 2% ë 1 signal Fig. 19: Trace display and event table for via port A-B with 98% ë 1 signal Table 1: Summary of insertion loss and reflectance in network testing Test Losses in 15 km (db) Losses in PIM Device (db) Losses in 20 km (db) Total losses (db) Refl. (db) 1 4.992 1.807 6.694 13.493-39.24 2 3.148-0.023 1.814 4.939-38.86 3 2.783 - - 2.783 > -16.2 4 2.775 1.646 3.757 8.177-39.9 * Total losses in network = losses in 15 km optical fiber + loss in PIM device + losses in 20 km optical fiber Discussions: We proposed the network scanning and analysis with low-cost mini OTDR in this paper. The results were further analyst with OTDR emulation software and also with the CFDS. In the experiment, CFDS enable the scanning results to be displayed onto one computer screen and defined automatically the line s status as compared to existing commercialized OTDR which display the real-time result over one time. We also highlighted the possibility of using mini OTDR in this set up to transfer data manually. Although the latest upgraded version of OTDRs are able to transfer the data in automatic mode so the analysis of results can be implemented immediately decrease the processing time. Therefore, we emphasized that CFDS can work together with automatic mode and manual mode OTDR elsewhere to scan the line status centrally at the CO such as optical line terminal (OLT). 3370

Fig. 20: Display 4 network testing results and a failure message Line 3 FAILURE at 15.2582 km from CO! ' on Linestatus window in CFDS Fig. 21: The optical power in first test is decreasing 1.807 db at distance 15.2633 km Conclusion: We had proof our proposed system with the combination of CFDS and PIM device can be used in determining the status of each optical fiber by using the PIM device network configuration. The PIM device is the hardware monitoring that is used to tap out the optical signals from a fiber. Therefore, the status of each signal can be determined. In contrast with the CFDS is to troubleshoot and monitoring the status of each fiber. With this combination, the status of transmission in FTTH can be defined accuracy. 3371

Fig. 22: The optical power in first test is decreasing 4.939 db at distance 15.2582 km Fig. 23: The line 3 is failure at 15.2582 km from CO Fig. 24: The optical power in fourth test is decreasing 1.646 db at distance 15.2632 km 3372

ACKNOWLEDGMENT This research work was supported by the Ministry of Science, Technology and Innovation (MOSTI), Government of Malaysia, through the National Science Fund (e-science) 01-01-01-SF0493. The authors are also grateful to the Photonic Technology Laboratory, Institute of Micro Engineering and Nanoelectronic (IMEN), Universiti Kebangsaan Malaysia (UKM), Malaysia for providing the facilities to carry out the experiments. REFERENCES Abbou, F.M., H.Y. Wong, C.C. Hiew, A. Abid, H.T. Chuah, 2007. Performance evaluation of dispersion managed optical TDM-WDM transmission system in the presence of SPM, XPM and FWM, Journal of Optical Communications, 28(3): 221-224. Bakar, A.A.A., M.Z. Jamaludin, F. Abdullah, M.H. Yaacob, M.A. Mahdi, M.K. Abdullah, 2007. A new technique of real-time monitoring of fiber optic cable networks transmission ; Optics and Lasers in Engineering 45:126-130. Cai, J.X., M. Nissov, C.R. Davidson, A.N. Pilipetskii, G. Mohs, H.F. Li, Y. Cai, E.A. Golovchenko, A. J. Lucero, D. Foursa, N.S. Bergano, 2002. Long-haul 40 Gbits DWDM transmission with aggregated capacities exceeding 1 Tb/s, Journal of Lightwave Technology, 20: 2247-2257. th Caviglia, F., V.C.D. Biase, 1998. Optical maintenance in PONs ; Proceeding 1998 24 European Conference on Optical Communication, 621-625. Chan, C.K., F. Tong, L.K. Chen, K.P. Ho, D. Lim, 1999. Fiber-fault identification for branched access networks using a wavelength-sweeping monitoring source ; IEEE Photonics Technology Letters, 11(4): 614-616. Chomycz, B., 1996. Fiber optic installation: a practical guide ; NewYork: McGraw Hill. th EXFO, 2000. FTB-7000 optical time domain reflectometer series ToolBox 5 instruction manual (7 ed.) ; Canada: EXFO Electro-Optical Engineering Inc. Farmer, J.O., K. Bourg, 2008. Practical deployment of passive optical networks ; IEEE Communications Magazine, 46(7): 136-145. Hutcheson, L., 2008. FTTx: current status and the future, IEEE Communications Magazine, 46(7): 90-95. Lee, L., S.B. Kang, D.S. Lim, H.K. Lee, W.V. Sorin, 2006. Fiber link loss monitoring scheme in bidirectional WDM transmission using ASE-injected FP-LD, IEEE Photonic Technology Letters 18(3): 523-525. Lu, Y.G., X.P. Zhang, F. Wang, Y.H. Liu, 2006. Optical cable fault locating using Brillouin optical time domain reflectometer and cable localized heating method, Journal of Physics: Conference Series, 48(49): 1387-93. Menif, M., H. Fathallah, 2007. An encoder/decoder device including a single reflective element for optical code division multiple access system, Journal of Optical Communications, 28(3): 172-174. www.ezcom.cn/english/digital%20library/200612/13.pdf http://www.e-photon-one.org/ephotonplus/servlet/utils.mostrarfit xerpublic?fitxer=d_vd- A_3.pdf&pathRelatiu=E-Photon+One+ %2B%2FPublic%2FPublic+Deliverables%2F http://www.naval.com/sp-to-test Wuilpart, M., A. Grillet, K. Y uksel, D. Gianone, G. Ravet, P. M egret, 2007. Dynamics enhancement of OTDR-based monitoring systems for passive optical networks, Proceedings Symposium IEEE/LEOS Benelux Chapter, Brussels, 167-170. 3373