BC3250. Blowdown Controller

Similar documents
LC1350 Level Controller

LC3000 Level Controller Installation and Maintenance Instructions

LC2200 Level Controller Installation and Maintenance Instructions

- to scroll through the menus. - to increase digits when in a menu.

LC2610 Level Controller Installation and Maintenance Instructions

Archive. LC2200 Level Controller. 1. Safety information. 2. General product information. 3. Installation. 4. Setting up the controller

LC2650 Level controller

Commissioning password. This page MUST be removed after commissioning and kept in a safe, access controlled location.

UDC 700 Universal Digital Controllers and Indicator Specifications

Electronic steam boiler controls

Series Temperature Controller Instruction Sheet

PA ma Loop Powered Level Preamplifier

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

Process Alarm Module RTA 421

Corporate Profile. needs and product demands. CON 08X /03 Rev 0

RS Pro Infrared Temperature Sensor

C-Bus Four Channel General Input Unit Installation Instructions

TDS Conductivity Probe In-Line conductivity measurement

02/11/2015

02/11/2015

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1

UDC100 Universal Digital Controller Specifications

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

Nov 08 PRODUCT SPECIFICATION SHEET

LP30 High Integrity Low Level Alarm Probe Installation and Maintenance Instructions

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

Duct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

4 Ó â. Contactor RTA421. Contactor with loop power supply for monitoring currentorvoltagesignals. Technical information TI074R/09/en

RE-PR3-E-27 3-Phase Panel Mount 27kW

/8 DIN Level Indicator

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

Specification , July 2015

General Specifications

Multi-Gas-Controller MGC2

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

Carbon Monoxide Transmitter

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

APPLICATION DATA SHEET

MultiMeter 44. Transmitter-regulator with 1, 2 or 3 channels. Quality at a reasonable price

Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature

Miniature Infrared Temperature Sensors with Optional Touch Screen Display. PSC-SSS-PM with touch screen display (-CRT version)

C SINGLE-POINT HEAT-TRACING CONTROL SYSTEM PRODUCT OVERVIEW

Temperature Controllers

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

Two-Channel Gas Controller

Dual Input ph/orp Analyzer

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Turbimax CUE21 / CUE22

DPB52. True RMS 3-Phase, Multifunction monitoring relay. Benefits. Description

920 Series. A dry contact relay is provided for alarm annunciation back to a distributed control system (DCS).

Figure 1 DirectLine DL423 Sensor. Description, continued

ACCS-30. Multipoint commercial heat-tracing control system

NGC-UIT-ORD User interface terminal for Raychem NGC systems Installation Instructions

Dual Input ph/conductivity Analyzer

More Precision. indusensor // Linear inductive displacement sensors

VA301C CONTROLLER WITH BACnet OPTION

LEAKSTOPPER RANGE Multizone water leak detection systems

DMFPM-2R MULTIFUNCTIONAL

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM

C SINGLE-POINT HEAT-TRACING CONTROL SYSTEM. product overview

RAYCHEM NGC-30 COMPONENTS

The next generation thermometer from the global leader

IGD.CO.UK

More Precision. indusensor // Linear inductive displacement sensors

for relative humidity and temperature with calibration certificates

Dual Input Toroidal Analyzer

S304 and S305 Dust Emission Monitors. User Manual. Distributor

P R O D U C T D ATA S H E E T

Instruction Manual August sitrans CU 02

QFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature

Hot water temperature maintenance. Less water volume and less heat loss in the pipe work help prevent bacteriological

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

Series Digital Controller Instruction Sheet

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

P R O D U C T D ATA S H E E T

4/8/12/16 Channel Temperature Scanner with FREE Data Logging PC Software RS485

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm

Models 4623, 4628 & 5999/980 USP<645> Conductivity Analyzers

LaserGuard2. Laser Collision Avoidance System. Part Number: R1 April 2015 Copyright 2015 Magnetek Material Handling

Dissolved Oxygen Analyzers

RS485 MODBUS Module 8AI

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

Pump-Up Controller MODEL 4062

F4 Process Controller Installation and Operation Guide

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

LEAKSTOPPER 1 Single zone water leak detection system

Designed for testing three-phase circuits up to 600V Install on line or load side of electrical disconnect Detects absence of AC and DC voltage

More Precision. indusensor Linear inductive displacement sensors

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

DL423 DirectLine Sensor Module for Conductivity Measurement Specifications

the next generation thermometer from the global leader

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

FT702LT Turbine control wind sensor gives durability a new meaning FT702LT. series

Figure 1 DirectLine DL423 Sensor. Description, continued

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

910 Series Single-point heat-tracing control system

CTT8 TEMPERATURE MONITOR DEVICE

Transcription:

Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without notice. Copyright 2017 TI-P403-90 AB Issue 6 Blowdown Controller Description The is a blowdown controller for steam boilers. It controls TDS (total dissolved solids - salts in solution) by opening and closing a blowdown valve. Clamping screw It also has a timer that controls a bottom blowdown valve, to remove precipitated solids from the bottom of the boiler. The product works in conjunction with a Spirax Sarco conductivity sensor, a boiler blowdown valve and, for condensate contamination detection, a dump valve. It can operate on a supply voltage of between 110 to 240 Vac at 50 / 60 Hz. 100 Graphic display The front panel has an LCD graphics display and five-button keypad to select, view, and change functions. 50 In run mode (standard setting) the display is divided into three sections: i) Process variable and control parameters. ii) Information line, displays the various control states and process units. SP PV AL 0 % iii) Three bar graphs, which show a percentage of full scale of: - PV Process Variable highest and lowest recorded value. OK 5 button display - SP Set Point and hysteresis point. - AL High Alarm and hysteresis point. Clamping screw An additional filter can be selected to increase the damping effect where the probe is fitted directly in the boiler. This avoids overfrequent valve operation. A Trend graph screen display appears if the right or left button is pressed in run mode - This displays a record of the variation in TDS over a set time. The can be used on a condensate contamination system. Please note that it will not detect contaminants that do not change the conductivity, e.g. oils, fats, or sugars. The blowdown may be set to pulsed, rather than continuous output, opening for 10 seconds, and closing for 20 seconds. This avoids the risk of triggering a low water alarm in smaller boilers. An isolated 0-20 or 4-20 ma output is provided for remote display of the TDS level or as an output to a management system. If a switch box is fitted to the bottom blowdown valve actuator, an alarm can be configured to indicate if the bottom blowdown valve fails to close or to lift off its seat. The can communicate via an infrared link between adjacent controllers. It can be designated as either a master unit or a slave unit. Principal features: - Blowdown controller with bottom blowdown timer. - Multi-voltage 110 Vac to 240 Vac. - UL and TÜV approved. - Display in µs / cm or ppm. - LCD graphics display of PV and sequential trend graph. - Filter for turbulent conditions. - Infrared communications. - Diagnostic / test facility. - 0/4-20 ma output. - EIA 485 / Modbus communications. The unit can be panel, DIN rail or chassis mounted. Page 1 of 6

Clamping screw 100 Graphic display 50 0 % SP PV AL OK 5 button display Clamping screw Approvals This product complies with the Electromagnetic Compatibility Directive 2014/30/EU and all its requirements. The is suitable for Class A Environments (e.g. industrial). A fully detailed EMC assessment has been made and has the reference number UK Supply BH 2008. The complies with the Low Voltage Directive by meeting the standards of: - EN 61010-1:2010 safety requirements for electrical equipment for measurement, control, and laboratory use. The has been type-tested as a TDS controller by meeting the standard: - Vd TÜV requirements for TDS control device, Water Level 100 (07.2010). - UL listed (open) Function Inputs The can accept a signal from a Spirax Sarco CP10, CP30 or CP32 conductivity probe, and a Pt100 temperature sensor. Function / outputs If the water conductivity exceeds the Set Point, the valve relay will be energised until the conductivity drops below the Set Point. If the water conductivity exceeds the alarm level, the alarm relay will be de-energised until the conductivity drops below the alarm level. Other features: - Test function. - Direct display of probe factor. - Commissioning parameters protected with a pass code. Page 2 of 6

Technical data Power supply Environmental Mains voltage range Power consumption General Maximum altitude Ambient temperature limits Maximum relative humidity Overvoltage category Pollution degree Enclosure rating (front panel only) LVD (safety) EMC 110 Vac to 240 Vac at 50 / 60 Hz 7.5 W (maximum) Indoor use only 2 000 m (6 562 ft) above sea level 0-55 C 80% up to 31 C decreasing linearly to 50% at 40 C III 2 (as supplied) 3 (when installed in an enclosure) - Minimum of IP54 or UL50 / NEMA 3, 3S, 4, 4X, 6, 6P or 13. NEMA type 4 hose down only (UL approval) and IP65 (verified by TRAC Global) Electrical Safety EN 61010-1 UL61010-1, 3rd Edition, 2012-05 CAN/CSA-C22.2 No. 61010-1, 3rd Edition, 2012-05 Immunity / Emissions Enclosure Material Polycarbonate Front panel Colour Material Pantone 294 (blue) Silicone rubber, 60 shore. Solder Tin / lead (60 / 40%) Mains and signal connector Termination Cable size Stripping length Rising clamp plug-in terminal blocks with screw connectors. Caution: Use only the connectors supplied by Spirax Sarco Ltd. Safety and Approvals may be compromised otherwise. 0.2 mm² (24 AWG) to 2.5 mm² (12 AWG). 5-6 mm High temperature Number of cores 4 TDS cable / wire Recommended type 1 1.5 mm² (18-16 AWG) 0-9.99 range - 10 metres 0-99.90 range - 30 metres 0-999.0 range and 0-9990 ranges - 100 metres Prysmian (Pirelli) FP200, Delta Crompton Firetuf OHLS High temperature, twisted Pt100 probe cable / wires Number of cores 3 1 1.5 mm² (18-16 AWG) 100 m (328 ft) Page 3 of 6

Technical data (continued) Twisted pair 0/4-20 ma output(s) cable/wire Number of pairs 1 0.23-1 mm² (24-18 AWG) Recommended type 100 m (328 ft) various EIA RS485 twisted pair RS485 communication cable / wire Number of pairs 2 or 3 0.23 mm² (24 AWG) 1200 m (4000 ft) Recommended type Alpha Wire 6413 or 6414 LAN Cat 5 or Cat 5E ScTP (screened), FTP (foil) or STP (shielded) cable can be used, but limited to 600 m. Probe types CP10, CP30 and CP32 Minimum 1 µs @ 25 C Water conductivity Ranges Accuracy ph factor 0 9.99 ppm or µs/cm 0 99.9 ppm or µs/cm 0 999 ppm or µs/cm 0 9990 ppm or µs/cm ±2.5% FSD (Poss > if high EMC) 0.50 1.00 (0.7 default) Input technical data Neutralising factor 0.7 Resolution 0.1% FSD Drive: ac 4 wires Sensor type Pt100 Class B or better Temperature compensation (TC) Range 0-250 C (With Pt100 not fitted user programmed temperature 100-250 C, 1 C steps) Accuracy ±2.5% FSD system accuracy ±5% Resolution 1% FSD Burner input Drive: Input voltage range Maximum current input dc 3 wires 110 240 Vac 2 ma maximum Page 4 of 6

Technical data (continued) Probe cleaning Maximum voltage Drive 32 Vdc ac/dc/pulsed Minimum current 0 ma Maximum current 20 ma 4-20 ma Open circuit voltage (maximum) Resolution 19 Vdc 1% FSD Maximum output load 500 ohm Isolation 100 V Output rate 10 / second Contacts 2 x single pole changeover relays (SPCO) Voltage ratings (maximum) 250 Vac Resistive load 3 amp @ 250 Vac Inductive load 1 amp @ 250 Vac Output technical data Relays ac motor load Pilot duty load ¼ HP (2.9 amp) @ 250 Vac 1 / 10 HP (3 amp) @ 120 Vac C300 (2.5 amp) - control circuit / coils Electrical life (operations) 3 x 10 5 or greater depending on load Mechanical life (operations) 30 x 10 6 Physical layer RS485 4-wire full or 2-wire half duplex Protocol Modbus RTU format RS485 Isolation 60 Vac/dc Receiver unit load (256 devices - maximum) Output rate Up to 10 frames / second Physical layer IrDA Baud 38 400 Infrared Range 10 cm Working angle 15 Eye safety information Exempt from EN 60825-12: 2007 Safety of laser products - does not exceed the accessible emission limits (AEL) of Class 1 Page 5 of 6

Safety information, installation and maintenance Warning: This document does not contain sufficient information to install the unit safely. The unit operates at a potentially fatal mains voltage. Before attempting to install the unit read the Installation and Maintenance Instructions supplied with it. The product must be installed in a suitable industrial control panel or fireproof enclosure to provide impact and environmental protection. A minimum of IP54 (EN 60529) or 3, 3S, 4, 4X, 6, 6P and 13 (UL50/NEMA 250 ) is required. The product may be installed on a DIN rail, a chassis plate, or in a panel cut-out. A bezel is supplied. Install the product in an environment that minimises the effects of heat, vibration, shock and electrical interference. Do not install the product outdoors without additional weather protection. Do not attempt to open the product - it is sealed and has no replaceable parts or internal switches. Do not cover or obstruct the infrared beam between products. Your attention is drawn to IEE Regulations (BS 7671, EN 12953, EN 12952 and EN 50156). Elsewhere, other regulations will normally apply. All wiring materials and methods shall comply with relevant EN and IEC standards where applicable. No special servicing, preventative maintenance or inspection of the product is required. Boiler water level controls and level alarms do, however, require testing and inspection. General guidance is given in Health and Safety Executive Guidance Notes BG01 and INDG436. Dimensions / weight (approximate) in mm and g. Weight 550 g. 52 mm 120 mm 8 mm 112 mm 100 50 140 mm 120 mm 0 % SP PV AL OK How to specify Blowdown controller with integral bottom blowdown timer and infrared comms. How to order Example: 1 off Spirax Sarco blowdown controller. Page 6 of 6