Multipurpose Cables (indoor/outdoor), Multipurpose central tube cable (maxibundle) with glass yarn armouring A-DQ(BN)H 4-24

Similar documents
Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers

Fiber Optic Distribution Cables (6-144 Fibers)

TE CONNECTIVITY <fiber count> <fiber type> <flame rating> MM/YY SO<shop order number> XXXXX FEET

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1

outdoor and indoor campus backbone, building backbone (riser) FDDI, Gigabit Ethernet and ATM Easy to install direct burial halogen-free

GUCN. Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection v13.

Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive

Data sheet OpDAT mini breakout cable 24x1 OM4 - bend insensitive

GCRG. Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection v7.0. Ordering Information.

GBRD. Multi Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection. Ordering Information. Applications. Features & Benefits

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

GUSN. Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection. Ordering Information.

Ø 1000 * 588 mm 50 kg

GUSA. Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection. Ordering Information.

Fibre Optic Cable. Catalogue.

Easy to install in ducts, tunnels and trenches by means of compressed air or pulling wire. Suitable for direct burial (crush 400 N/cm).

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

FTTX Solutions Mini Rapid Fiber Distribution Terminal (RDT)

Duct Cable GYTS-144B1.3

GOF Indoor and Outdoor Cables. Documentation VWL Version 1.1 Source Code M

Optical Fibre Cable Technical Specification. Duct Cable GYTA-72B1.3

HELKAMA. Optical Fibre Cables

OPTICAL. Micromodule DW About Us. > IEC nd Ed. According to. > EN nd Ed. FTTx

GOF Indoor and Outdoor Cables. Documentation VWL Version 2.2 Source Code R

industry solutions: military

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK

TELECOM SOLUTIONS CABLE CATALOGUE INNOVATIVE FIBRE OPTIC CABLE SOLUTIONS

Special Provision No. 683S28 December 2017

CHALLENGE OF THE NEW OPTICAL FIBRE TECHNOLOGIES

Sumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber. PureGuide SM Optical Fiber, TIA Type IVd. Issued: November 2003

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

Sumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber

13-SDMS-02 REV. 00 SPECIFICATIONS FOR NON-METALLIC, TIGHT BUFFERED & RETRACTABLE, MICRO FIBER OPTIC CABLE FOR INTERNAL INSTALLATION

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.

SPECIAL ELECTRICAL AND OPTICAL CABLES

FiberExpress Solutions

DNVGL-CP-0402 Edition February 2016

Flame Retardant Overall Screened Instrumentation Cables (multicore)

SECTION COMMUNICATIONS OPTICAL FIBER BACKBONE CABLING

STAND OUT FROM THE CROWD. Bisham Abbey, 14th May 2002 INTRODUCTION. Work Smart FIA. The Fibreoptic Industry Association STAND OUT FROM THE CROWD

Fibre Specification Standards

FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS - Item No. FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS (TEMPORARY) - Item No.

Acceptance Requirements. Fibre Optic Systems. Revised 12/2017. December 5th, Alexander Kölbel

Fibre optic media options and trends

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION

Multi-Core Fire Resistant Cable

STANDARD CONFORMANCE

FIRE RESISTANT CABLES

Compact Module. Category 6A FTP Cabling System 1.1

Specification No.CSC-131/R-1/DH//UH/P&D/ Technical Specifications. for 24 Fiber/48 Fiber Unarmoured. Underground Fibre.

Catalogue Telecommunication Cables INTRODUCCIÓN

High Performance LSZH Fire Resistant Cable

Fibre (TIA) Field Test Specification

Photovoltaic Cables EN H1Z2Z2-K

INTERIM EUROPEAN I-ETS TELECOMMUNICATION June 1997 STANDARD

Fiber Optic Patch Cord and Pigtails

PRODUCT CATALOGUE Norröna

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. YD/T Translated English of Chinese Standard: YD/T

Product Specification CAT 6 UNSHIELDED PATCH CORDS

Telecommunication Cables

Fiber Optic and CAT 5, 6, 7 and 8 Installer Premise Cabling

STANDARD FOR INDOOR-OUTDOOR OPTICAL FIBER CABLE

Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for Panel and Remote Mounting. Features. Operation.

Cable technology for highest safety requirements

Caledonian Flame Retardant Coaxial Cables

4120 Fire Alarm Network Reference

Hands-On Fiber Optics ISP/OSP - Advanced Combo- Tech

fire resistant cables

CATEGORY 6A FTP RJ45 SOLUTION

Attenuators. Fiber Optic Products Catalog. Singlemode Build Out Attenuators. Product Facts. Applications. Customizable Features. Available Collateral

INTERNATIONAL STANDARD

Hands-On Fiber Optic ISP / OSP Combo-Tech Splicing, Termination & Testing

INTERNATIONAL STANDARD

Detection of Solvents using a Distributed Fibre Optic Sensor

INTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

BS /1000V XLPE Insulation LSZH Sheath Cables

Qualification Test Report LC Duplex Adapter For LC Cutouts

Clearlite Photonic Fibers

ENHANCED FIRE PERFORMANCE CABLE

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores)

SPECIFICATIONS - DETAILED PROVISIONS Section Fiber Optic Cabling and Components C O N T E N T S

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)

OPTICAL FIBER SOLUTIONS

Qualification Test Report LightCrimp* Plus Singlemode and Multimode LC Connector (Field Installable)

LCS 2 YOUR digital infrastructure

/Oct/2014 Rev B

VTI Services Technical Bulletin (TB) OTDR Measurement of Installed Optical Fibre Cabling Permanent Links and Links

STANDARD FOR INDOOR-OUTDOOR OPTICAL FIBER CABLE

STANDARD TEST PROCEDURE PRE-TEST QUALITY OF OPTIC FIBRE CABLE ON DRUMS TYPE OF CABLE :

C6 Premium. C6 Premium Copper Systems from Infinique is premium performing Class E / Category 6 Data Communication

/Mar/2014 Rev A

INTERNATIONAL STANDARD

Comtran Cable. Hub-LINK Cables for Transit Applications

This is a preview - click here to buy the full publication

Wire and Cable. For more information on these Tyco Electronics products, visit the following website:

TECHNICAL REPORT IEC/TR Fibre optic communication system design guides Part 11: Multimode launch conditions. Edition 1.

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

Transcription:

Features and Benefits Laminated swelling glass yarns Improved rodent resistance and longitudinal water protection UV and microbe resistant Can be directly buried or installed in ducts Metal-free cable No ground loop problems Fibres/buffer tubes colour coding to IEC 60304 (Telcordia-Bellcore) Easy identification of the individual tubes and fibres The MPC (Multi-Purpose Cables) central tube (indoor/ outdoor maxibundle) cables can be deployed both indoor and outdoor for campus backbone and building backbone (riser) cabling as well as for the cabling between floor distributors. The cables can be installed in conduits, ducts and be buried directly in the ground. Standards Waterblocking Flame test method Approval and Listings Waterblocking according to IEC 60794-1-2-F5 Low smoke (IEC 61034 and EN 50268) and zero halogen (LSZH) Non corrosive to IEC 60754-2 and EN 50267 Telcordia (Bellcore) colour standard for fibres and tubes LLDPE jacket, black Laminated swellable glass yarn Swellable elements Buffer tube, gel-filled with 4 fibres Fibre, 250 µm Ripcord A-DQ(BN)H Entral Tube OS2 A-DQ(BN)H 1x4E9 OS2/125 CT Page 1 Revision date 2012-12-14

False Multipurpose Cables (indoor/outdoor), LLDPE jacket, black Laminated glass yarn Swellable elements Buffer tube, gel-filled with 2x12 fibers Fibre, 250 µm Ripcord A-DQ(BN)H Central Tube OM2/OM3/OM4 A-DQ(BN)H 1x24G50CC OM4/125 CT Specifications Cable Design Fibre colouring Blue, orange, green, brown, grey, white, red, black, yellow, violet, pink, turquoise Buffer tube colour coding Yellow (E9/125), Green (G50/125), Blue (G62.5L/125) Buffer tube diameter up to 12 fibres 3 mm, > 12 fibres 5 mm Outer jacket material Linear Low Density Polyethylene (LLDPE) Outer jacket nominal thickness 1.5 mm Outer jacket colour Black Cable marking Metre - Handset - Sine - CORNING - Year - Cable type + Fibre count + Fibre type Temperature Range Installation and assembly -5 C to 50 C Operation -20 C to 60 C Storage -25 C to 70 C Page 2 Revision date 2012-12-14

Mechanical Characteristics Cable Fibre Count Weight Nominal Outer Diameter Min. Bend Radius Installation Min. Bend Radius Operation Max. tensile strength for installation Crush Resistance 4-12 46 kg/km 6.6 mm 130 mm 100 mm 1000 N 1500 N/10cm 16-24 73 kg/km 8.6 mm 170 mm 130 mm 1500 N 1500 N/10cm * Fibre count per tube, colour coding of fibres and/or buffer tubes, hybrid construction, jacket colour and/or printings deviating from standard design have no influence whatsoever on mechanical and optical characteristics. Chemical characteristics RoHS Free of hazardous substances according to RoHS 2002/95/ EG Page 3 Revision date 2012-12-14

Transmission Performance Fibre Name G62.5L/125 InfiniCor 300 E9/125 SMF28e+ Fibre Type Multimode Multimode Multimode Multimode Single-mode Fibre Core Diameter (µm) 50 50 50 62.5 9 Fibre Category OM4 OM3 OM2 OM1 OS2 Wavelengths (nm) 850 / 1300 850 / 1300 850 / 1300 850 / 1300 1310 / 1383 / 1550 Maximum Attenuation (db/km) 2.8 / 1 2.8 / 1 2.8 / 1 3.1 / 0.8 0.36 / 0.36 / 0.22 Typical attenuation (db/km) 2.4 / 0.8 2.4 / 0.8 2.4 / 0.8 2.9 / 0.7 Min. Overfilled Launch (OFL) Bandwidth (MHz*km) 3500 / 500 1500 / 500 700 / 500 200 / 600 Minimum Effective Modal Bandwidth (EMB) (MHz*km) 4700 / - 2000 / - 950 / - 220 / - Serial 1 Gigabit Ethernet (m) 1100 / 600 1000 / 600 750 / 600 / - 300 / 550 5000 / - / - Serial 10 Gigabit Ethernet (m) 550 / - 300 / 333 150 / - 33 / - 10000 / - / 40000 Induced attenuation @ 7.5 mm radius (db) < 0.2 / - < 0.2 / - < 0.2 / - Standards in Compliance 492AAAD, Tested with min EMBc method to 455-220, IEC 60793-2- 10 Type A1a.2 Ed.2.0 and IEC 60793-1-49 ED.2.0 ITU-T 11801 Cat. OM4 492AAAC-A, Tested with minembc method to TIA/ EIA 455-220, IEC 60793-2-10 Type A1a.2 Ed.2.0 and IEC 60793-1-49 Ed.2.0, ITU-T 11801 Cat. OM3 492AAAB, Restricted Mode Launch (RML) according to TIA/ EIA 455-204 and IEC 60793-1-41, ITU-T G651, ISO/IEC 11801 Cat. OM2 492AAAA, Restricted Mode Launch (RML) accordig to TIA/ EIA 455-204 and (OFL) IEC 60793-1-41, ITU 11801 Cat. OM1 Fibre Code K H G A U Cable cutoff wavelength (nm) 1260 492-CAAB, IEC 60793-2-50 Type B1.3, ITU-T G.652 D, ISO/ IEC 11801 Cat. OS2 Page 4 Revision date 2012-12-14

Ordering Information Contact Customer Service at 00800-2676-4641 (00800-CORNING1) for other options. *Maximum delivery length per drum is 4000 metres +3/-2% for Multimode fibres and 6000 metres +3/-2% for Single-mode fibres. *Please notice that in the hybrid cables construction (different fibre types) the Multimode fibres are in sequence from the higher to the lower performance followed by the Single-mode fibres. *For ordering information regarding non-standard design cables please contact our Customer Service Centre. (See bottom of page for contact information.) Corning Cable Systems GmbH & Co. KG Leipziger Strasse 121 10117 Berlin, Germany TEL: 00800-2676-4641 (00800-CORNING1) FAX: +49-30-5303-2335 www.corning.com/cablesystems/emea A complete listing of the trademarks of Corning Cable Systems is available at www.corning.com/cablesystems/emea/trademarks. Corning Cable Systems is ISO 9001 certified. 2012 Corning Cable Systems. All rights reserved. Page 5 Revision date 2012-12-14