INDEX. Installation recommendation

Similar documents
INDEX. Installation recommendation

CONFIGURATION OF THE OPTICALS

INDICE. Installation recommendation

INDEX. Installation recommendation

DUAL OPTIC. Installation manual

INFRARED PERIMETRAL BARRIER DOUBLE BEAMS

INFRARED PERIMETRAL BARRIER DOUBLE BEAMS

SANDOR QUAD/ESA. Double beam. POLITEC s.r.l. Installation And commissioning manual

English. Series. Installation and Use Manual

PARVIS Safe and tranquil thanks to Parvis

Installation And commissioning manual. Series S Double Beam 1/16

Perimeter protection

DUAL TECHNOLOGY SENSOR (PIR + Microwave) Outdoor use INSTALLATION MANUAL

ITALIANO BST-100 ACTIVE INDOOR AND OUTDOOR INFRARED BARRIER WITH 2 BEAMS OF PROTECTION INSTALLATION MANUAL. Manuale istruzioni BST-100. Pag.

Active Infrared Multi Beam Sensors

perimeter barriers Active infrared SAFET Y INSIDE AND OUTSIDE THE HOME WALL-FLUSH INTERNAL OR EXTERNAL PROTECTION EXTERNAL PROTECTION

INFRARED MODULATED BARRIERS

Active Infrared Multi Beam Sensors. R Series

"Pegaso" wireless alarm system

BARRIERE & SENSORI BARRIERS & SENSORS

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

Long-Range Barrier Sensors

Movement Detector GJD 300

This symbol indicates prohibition. The specific prohibited action is provided in and/or around the figure.

5800-OD Wireless Outdoor Motion Sensor Installation Instructions

ACTIV8 ONE OFF. 1 Tips USER S GUIDE COMBINED RADAR OPENING AND ACTIVE INFRARED SAFETY SENSOR. 1 Description. 2 Symbols.

DHR3. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer. INSTALLATION INSTRUCTIONS

AX-100TFR/AX-200 TFR INTRODUCTION 1-1 BEFORE YOUR OPERATION BATTERY OPERATED PHOTOELECTRIC DETECTOR. Warning FEATURES. Caution. Warning.

PHOTOELECTRIC DUAL BEAM DETECTOR R4222 RECEIVER INDICATORS 1

Photobeam 5000 ISC-FPB1-W60QF, ISC-FPB1-W120QF, ISC-FPB1-W200QF. en Installation and Operation Guide

D-Tect 2 GJD300 Quad PIR Movement Detector

UNICA - ALARM SYSTEM WITH VISUAL VERIFICATION. All in One - All in Touch Video - Alarm System

High Precision Digital Rain Gauge with Indoor Temperature and Humidity

FSLIMPRO

BARRIERS & SENSORS Catalogue 2017

Table of Contents. 1. Mounting Tips... 2

Optical Beam Smoke Detector RK90R - RK90RS

"Pegaso" wireless alarm system D.I.Y. wireless kit

DH400. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer.

Solar Powered Wireless Photobeam Sensors

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

PHOTOELECTRIC BEAM SENSOR PR-11BE : OUTDOOR 3.3 to 36ft. (1 to 11m) : INDOOR 3.3 to 49ft. (1 to 15m)

THE BEST SOLUTIONS FOR OUTDOOR PERIMETER PROTECTIONS

Photobeam 5000 ISC-FPB1-W60QS, ISC-FPB1-W120QS, ISC-FPB1-W200QS. en Installation and Operation Guide

Danfoss gas detection units

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

KwêBeams Effective wire free outdoor early warning system

mod. ERHSO712 mod. ERRHSO712 ENGLISH CONTROLLER mod. CSRLS MAINTENANCE ADDITIONAL CONTROLS

D296/D297. Installation Instructions Long-Range Beam Smoke Detectors

INSTALLATION INSTRUCTIONS. This model is UL Listed product. The comment with *UL-Number are UL s requirements and information for using this product.

GJD OPAL RFX WIRELESS 35 METRE EXTERNAL PIR INSTALLATION MANUAL

PHOTOELECTRIC DETECTOR

TITLE SLIDE. FIRERAY2000 EExd OPTICAL BEAM SMOKE DETECTOR. Doc. No: Copyright Fire Fighting Enterprises Ltd.

D-TECT Dual Tech. GJD360 Triple Technology External Detector

80 CHANNELS WIRELESS RECEIVER WITH LCD DISPLAY M1.1.1-Hx.x-F1.1-ENG [AN] [SPV] MADE IN ITALY INSTALLATION AND USE MANUAL

Instruction manual. Digital Radar Motion Detector with Infrared Remote Control MWD BF. FEIG ELECTRONIC GmbH Lange Straße Weilburg/Lahn

ACTIVE INFRARED BARRIER

Original operating instructions Photoelectric safety sensors (safety light curtain / safety light grid) Protected area width (range) 0...

PHOTOELECTRIC DETECTOR

Elite. GJD022 /GJD023 35m External PIR. Multi Beam Lens Data

GSM RFID VOICE Alarm System

RS Pro Infrared Temperature Sensor

/ / 2018

Light Walls HB-T001Q3 HB-T001R3

Operating Instructions

Photoelectric Beam Detector

No INSTALLATION INSTRUCTIONS m (7.6-3 ft.) Far area mirror Masking plate for far area Fixing rubber form

Description. Optex Incorporated

Operating Instructions

BENTEL SECURITY reserves the right to modify the technical features of this product without prior notice.

Danfoss gas detection units

A3G Green Rotary Laser SPECIAL EDITION INSTRUCTION MANUAL

FIRE STROBE 2000 INSTALLATION INSTRUCTIONS

Safety Photo Beam UL MONITORED DEVICE

COMPANY PROFILE. a A SOLID REPUTATION. a DETAIL IN MANUFACTURING PROCESS. a SICURIT A TRUSTED SUPPLIER

Fireray Application and. Installation Guide FEATURES. Range metres. 12V to 24V dc operation. Selectable alarm thresholds

LZR -H110. LASER SCANNER FOR BARRIERS & GATES with max. detection range of 5.0 m x 6.5 m (16.5 ft x21 ft) User s Guide

Reflective Optical Beam Smoke Detector User Guide

INSTALLATION AND MAINTENANCE INSTRUCTIONS 6500R AND 6500RS REFLECTIVE TYPE PROJECTED BEAM SMOKE DETECTOR

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

D-TECT 3 IP. GJD260 IP Motion Detector

WIRING DIAGRAM AND INSTRUCTIONS

INSTALLATION AND MAINTENANCE INSTRUCTIONS 6500R AND 6500RS REFLECTIVE TYPE PROJECTED BEAM SMOKE DETECTOR

DETECTOR TRANSMITTER INSTALLATION & OPERATING. Cat No. TLTX2000B INSTRUCTIONS

Radio Controlled Kids Projection Clock with Nightlight

ENFORCER SENSOR MANUAL. Multi-Frequency Quad Photobeam Detectors

THE EVOLUTION OF CONTROL APP & CLOUD PORTAL

Operating Instructions

other ambient light sources. Before installation, make sure to read this instruction manual carefully for safe and effective product operation.

Twin Photobeam Detectors Manual

Infrared Single Light Barrier. Mounting Instructions DO560

REDNET INFRARED BEAM SET TYPE RN4/10-25, RN4/25-75 & RN4/ INSTALLATION AND SET UP INSTRUCTIONS

MOBILE CALL GSM Alarm System User s Manual

Installation and Programming manual INSTALLATION MANUAL E PROGRAMMING INSTALLAZIONE PROGRAMMAZIONE

CONTENTS. La Crosse Technology, Ltd. Page 1

TX7130. Conventional Reflective Beam Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

D296/D297. Application Guide. Projected Beam Smoke Detectors

CR7075 Two-Stage Lighting Controller

Installation and Operation Manual

Motorised Infrared Optical Beam Smoke Detector. User Guide

Transcription:

Technical manual

INDEX 1 MAIN COMPONENTS Pag. 3 2 ASSEMBLING THE CABLEPIT Pag. 4 CABLE PIT POSITIONING Pag. 6 3 BASE INSTALLATION ON CABLE PIT Pag. 8 4 INSTALLATION EXAMPLES Pag. 9 5 CONFIGURATION OF THE OPTICALS Pag. 10 OPTICAL TX Pag. 10 OPTICAL RX Pag. 11 6 SANDOR WS SMA TX MOTHER BOARD Pag. 12 7 SANDOR WS SMA RX MOTHER BOARD Pag. 13 8 SETTINGS & FUNCTIONS Pag. 14 DIP SWITCHES Pag. 14 9 COLUMN ALIGNMETN Pag. 15 10 CALIBRATION WITH SMA SYSTEM Pag. 16 11 CALIBRATION WITH PARALLEL BEAMS Pag. 20 12 ALARM SENSITIVITY ADJUSTMENT Pag. 21 13 TECHNICAL CHARACTERISTICS Pag. 22 14 F.A.Q. Pag. 23 Installation recommendation Verify that the beam tower is fully watertight once the cover and end caps have been correctly filled at the end of the installation. Use the cable glands supplied on the tower for all cabling must pass through the lower end cap using the cable glands supplied. The missed used of proper accessories decrease the IP grade protection of the tower. Avoid any type of obstruction between the transmitter and receiver. Avoid installing the receivers beams in a position where direct sunlight, at the same angle as the receivers beams, can enter directly into optics especially at sunset and sunrise Do not install multiple beams where the transmitter beam can interfere with other receiver beams. It is always better place either transmitter or receivers back to back. POLITEC s.r.l. Manual PARVIS WS SMA Ver. 2.2 2

1. MAIN COMPONENTS 1 4 3 7 8 11 9 2 N Description 1 Aluminium pole 2 Pipe IR 3 Plug 4 Lamp adapter 5 Base 6 Cablepit 7 Motherboard TX 8 Group optic TX/RX 9 Motherboard RX 10 Cover for the base 11 Battery 3.6 V 19 Ah 12 Wireless trasmitter position 12 5 10 6 POLITEC s.r.l. Manual PARVIS WS SMA Ver. 2.2 3

2. ASSEMBLING THE CABLEPIT 1. Insert the highlighted edge into other section and fix with screws 1. Insert the third section in the same way and fix with screws. POLITEC s.r.l. Manual PARVIS WS SMA Ver. 2.2 4

3. Enlarge the two opposite walls of cable pit to allow the positioning of last section. 1. Insert and well fix the missing screws. POLITEC s.r.l. Manual PARVIS WS SMA Ver. 2.2 5

CABLE PIT POSITIONING The placement of the cable pit for PARVIS columns, after assembling, have to be done in the following way: cement all around the cable pit keeping the top edge of it at same level of ground. For PARVIS columns is also possible to keep the top edge ten centimeters below the level of the ground so that it is visible only the IR tube. This type of placement is possible only when the cable pit is fixed into the ground and not in a concrete pavement. POLITEC s.r.l. Manual PARVIS WS SMA Ver. 2.2 6

POSSIBLE CORRECTION OF THE INCORRECT POSITIONING Placement should be perpendicular to the ground. If the base is not in perfectly at ground level, is possible to adjust it through the insert regulation of cable pit. On the side that must be corrected loosen the insert in order to get the right inclination. WRONG POSITIONING CORRECT POSITIONING BY ADJUSTING INSERTS EXAMPLE OF SETTING POLITEC s.r.l. Manual PARVIS WS SMA Ver. 2.2 7

3. BASE INSTALLATION ON CABLE PIT Ensure that all the cables to and from the PARVIS tower passes through the supplied cable glands inserted into the base cap. Use the central cable gland for lightning cable. Base cover with the cable glands and O-ring Once the cabling is completed the base cap has to be fixed to the base with relative O-ring. POLITEC s.r.l. Manual PARVIS WS SMA Ver. 2.2 8

4. INSTALLATION EXAMPLES Per un installazione a controllo di perimetro posizionare le barriere come indicato: 4 BEAMS Simple barrier 8 BEAMS Single barrier 8 BEAMS Crossed barrier Note: if you use the optical sync do not place multiple transmitters on the same line in the same direction POLITEC s.r.l. Manual PARVIS WS SMA Ver. 2.2 9

5. CONFIGURATION OF THE OPTICALS OPTICAL TX TEST LED TAMPER TEST BUTTON TX1 TX2 TX3 TX4 TX5 TX6 1 2 3 4 5 6 1 2 3 4 5 6 NB: The address settings as per default. POLITEC s.r.l. Manual PARVIS WS SMA Ver. 2.2 10

OPTICAL RX TAMPER LOW SIGNAL LED TEST LED TEST BUTTON RX1 RX2 RX3 RX4 RX5 RX6 1 2 3 4 5 6 1 2 3 4 5 6 NB: The address settings as per default. POLITEC s.r.l. Manual PARVIS WS SMA Ver. 2.2 11

6. SANDOR WS SMA TX MOTHER BOARD TAMPER LED ON BATTERY CONNECTION 3,6 V 19 Ah N.B.: When the motherboard is supplied the LED ON will flash. POLITEC s.r.l. Manual PARVIS WS SMA Ver. 2.2 12

7. SANDOR WS SMA RX MOTHER BOARD TAMPER INTERVENTION DELAY ADJUSTING DIP SWITCH LED TEST BATTERY LOW (BL) 3,6 V 3,0 V SIGNAL LOW (SL) AND FOR REMOTE (AND) BATTERY CONNECTION 3,6 V 19 Ah ANTIMASK POUTPUT (AMK) - + ALARM TAMPER SUPPLY N.B.: When the motherboard is supplied by battery the TEST LED will flash POLITEC s.r.l. Manual PARVIS WS SMA Ver. 2.2 13

The board has Dip Switches to set different functions: 8. SETTINGS & FUNCTIONS DIP SWITCHES 4 DIP SWITCH TX 1 TEST In ON position goes in test for alignment. The TEST LED start blinking. 2 / Not in use 3 BEAM ON It puts in test all TX during alignment (DIP 1 ON). Test LED fixed ON. 4 BEAM OFF It puts OFF all TX during alignment (DIP 1 ON). Test LED fixed ON. 1 2 3 4 5 6 7 8 9 10 Ex.: Function AND 1-2 with 6 beams 10 DIP SWITCHES RX 1 AND At least 2 optical must be interrupted to give alarm 2 AND 1-2 AND function only for 1st and 2nd beam, usefull in case of growing grass 3 BEAM 3 First 3 RX are active 4 BEAM 4 First 4 RX are active 5 BEAM 5 First 5 RX are active 6 BEAM 6 all RX are active 7 S. LOW FOG disqualification active 8 A. CRAWL 9 AMK / ON - Anti crawling active. In this condition if the first beam (lower) is interrupted for more than 2 seconds, it will generate an alarm, independently of its configuration (i.e. AND) 10 TEST Put in ON to activate the TEST ON POLITEC s.r.l. Manual PARVIS WS SMA Ver. 2.2 14

1 2 3 4 5 6 7 8 HTR ALLARME TAMPER SUPPLY CONECTOR 8 Not utilized NC Alarm relay NC Tamper relay Possibility to supply the radio transmitter with 3,0 or 3,6 V CONNECTOR 4 BL BATTERY LOW Low battery indication (negative open collector) SL SIGNAL LOW Fog disqualification (negative open collector) REMOTE AN CONTROL Giving a positive (3,6 V) the AND function is activated ANTIMASK Segnalazione di mascheramento data dalla chiusura al negativo di un open collector. AMK 9. COLOUMN ALIGNMENT For proper alignment once installed barriers orient optical groups of the transmitters and receivers each optical groups in the direction of others. Adjusting horizontally through the manual movement, and vertically through the front screws placed above the lenses. Vertical adjustment Horizontal adjustment POLITEC s.r.l. Manual PARVIS WS SMA Ver. 2.2 15

10. CALIBRATION WITH SMA SYSTEM You can improve the calibration through the use of the supplied filter 1) Fold the device by following the folds preset 2) Place the filter in front of the optics TX positioning the two hooks on the pins of the fork optics to effectively search the signal alignment with critical conditions. Simply applying the filter only on the TX, no need to repeat the operation RX. POLITEC s.r.l. Manual PARVIS WS SMA Ver. 2.2 16

3) Put the DIP10 in ON on the motherboard to activate the programming mode indicated by the flashing LED test. During this phase the LED will continue to flash. DIP 10 4) Start the alignment of the barrier is on activating the transmitter optics TX TEST, pressing the dedicated button for about 3 seconds until the TEST LED turns orange. ORANGE LED TEST BUTTON POLITEC s.r.l. Manual PARVIS WS SMA Ver. 2.2 17

5) Turn the TEST on the corresponding optics receiver by pressing the dedicated button for about 3 seconds until the TEST LED turns orange, the Buzzer and LED alignment go ON. LED ARANCIONE PULSANTE DI TEST 6) Through the TRANSMITTER lens shifts, find the maximum optical alignment based on the BUZZER and LED (high-brightness) of alignment, the 'increase in the frequency of blinking of the LEDs and the whistle of the corresponding BUZZER indicate better ALIGNMENT. 7) By a FULL rotation on the horizontal axis of the RECEIVER optics, you make the SCANNING of the optical signal. 8) Rotating the optical RX find the maximum value of which corresponds to the ALIGNMENT LED (high-brightness) FIXED and whistle CONTINUOUS of the BUZZER. POLITEC s.r.l. Manual PARVIS WS SMA Ver. 2.2 18

9) Exit the function by repressing the ALIGNMENT TEST button for about 3 seconds on both optics (TX- RX) ensuring that the orange LED TEST is shown in original condition. LED ARANCIONE PULSANTE DI TEST 10) When finished, remove the shade that acts as a attenuator, with the certainty of having found the optimum value. 11) Once the alignment of all the beams is finished, put in OFF the DIP 10 on the motherboard to deactivate the programming mode indicated by the LED turns off. For the next 30 seconds the barrier will sound continuously in case of alignment not effective or interruption of a beam; correct the orientation of the columns so that the buzzer emits no longer any sound. N.B.: IF TEST LED KEEP FAST FLASHING DURING NORMAL USE OF SYSTEM ANOTHER INFRARED SOURCE IS DISTURBING (BARRIERS, GATE PHOTOCELL, ) CORRECT FUNCTIONING OF BARRIER POLITEC s.r.l. Manual PARVIS WS SMA Ver. 2.2 19

11. CALIBRATION WITH PARALLEL BEAMS Put in test the optical TX1 and RX1 and proceed with the calibration as explained RX2 RX2 TX2 TX2 RX1 RX1 TX1 TX1 Put in test the optical TX2 and RX2 and proceed with the calibration as explained RX2 RX2 TX2 TX2 RX1 RX1 TX1 TX1 N.B.: during the testing phase of an optical transmitter the other TX not in test are switched off automatically. POLITEC s.r.l. Manual PARVIS WS SMA Ver. 2.2 20

12. ALARM SENSITIVITY ADJUSTMENT You can set the barrier for HIGH sensitivity as crossing fast (running) or LOW as slow ( walking). By adjusting the potentiometer counterclockwise to increase the alarm delay up to 500ms. In this condition ensures the alarm of a person walking through the barrier, with the advantage of excluding the possibility of any false alarms such animals. Adjusting the potentiometer clockwise to decrease the alarm delay up to 50ms. In this condition ensures the alarm of a person crossing the barrier running at maximum speed. POLITEC s.r.l. Manual PARVIS WS SMA Ver. 2.2 21

MODELS 13. TECHNICAL CHARACTERISTICS PARVIS WS SMA 412 PARVIS WS SMA 416 PARVIS WS SMA 420 MAX RANGE INDOOR 200 m MAX RANGE OUTDOOR 50 m HEIGHT COLUMN 120 cm 160 cm 200 cm SYNCHRONIZATION Optical TOTAL BEAMS 4 parallel SUPPLY Battery 3,6V 19Ah BATTERY LIFE 3 years POLITEC s.r.l. Manual PARVIS WS SMA Ver. 2.2 22

14. F.A.Q I can t calibrate the columns o Make sure that there are no obstacles whatsoever interposed between RX and TX and that the conformity of the site does not pose an impediment; o Make sure that TX is being tested (orange LED of optic in question switched on and others turned off); o Make sure the connectors are securely attached and that the configuration of the DIP is correct; o Make sure that there are no external light sources that interfere with the correct reading of the signal (photocell gates, other barriers, infrared,...); After precisely aligned sensor (light LED steadily on and continuously BIP sound) system remains in alarm o Make sure the connectors are securely attached and that the configuration of the DIP is correct; o Verify that optic receiver senses the corresponding transmitter. To do this, set the AND mode, if the barrier is no longer in alarm obscure individually each ray finding one that does not generate the alarm general, this ray is not aligned; o Make sure that there are no external light sources that interfere with the correct reading of the signal (photocell gates, other barriers, infrared,...); With fog or rain, the system goes into alarm Repeated false alarms o Check that the function of disqualification from fog is active (see pag. 11); o Make sure that the structure is properly sealed and check that there are not already present within disturbing elements as water, insects,...; o Verify the accuracy of the alignment of each optic and in case reperform the procedure possibly making a complete scanning that there are no light sources that can influence the calibration; o For a more precise alignment position a side of the column cover in front of the lens in order to have two surfaces interposed between TX and RX for doubling attenuation of the beam. If they are caused by the passage of animals, use either AND, or increase the intervention time o Verify the accuracy of the alignment of each optic and in case reperform the procedure possibly making a complete scanning that there are no light sources that can influence the calibration; o To prevent radio interference, use as a link between the wireless transmitter and barrier a shielded cable with the shield to the negative of terminal block; POLITEC s.r.l. Manual PARVIS WS SMA Ver. 2.2 23

The system goes into disqualification even without fog o Verify the accuracy of the alignment of each optic and in case reperform the procedure possibly making a complete scanning that there are no light sources that can influence the calibration; o For a more precise alignment position a side of the column cover in front of the lens in order to have two surfaces interposed between TX and RX for doubling attenuation of the beam. POLITEC s.r.l. Manual PARVIS WS SMA Ver. 2.2 24