INDEX. Installation recommendation

Similar documents
INDICE. Installation recommendation

INDEX. Installation recommendation

CONFIGURATION OF THE OPTICALS

INDEX. Installation recommendation

DUAL OPTIC. Installation manual

INFRARED PERIMETRAL BARRIER DOUBLE BEAMS

INFRARED PERIMETRAL BARRIER DOUBLE BEAMS

SANDOR QUAD/ESA. Double beam. POLITEC s.r.l. Installation And commissioning manual

PARVIS Safe and tranquil thanks to Parvis

English. Series. Installation and Use Manual

Installation And commissioning manual. Series S Double Beam 1/16

Perimeter protection

BARRIERE & SENSORI BARRIERS & SENSORS

DUAL TECHNOLOGY SENSOR (PIR + Microwave) Outdoor use INSTALLATION MANUAL

perimeter barriers Active infrared SAFET Y INSIDE AND OUTSIDE THE HOME WALL-FLUSH INTERNAL OR EXTERNAL PROTECTION EXTERNAL PROTECTION

BARRIERS & SENSORS Catalogue 2017

Long-Range Barrier Sensors

UNICA - ALARM SYSTEM WITH VISUAL VERIFICATION. All in One - All in Touch Video - Alarm System

ITALIANO BST-100 ACTIVE INDOOR AND OUTDOOR INFRARED BARRIER WITH 2 BEAMS OF PROTECTION INSTALLATION MANUAL. Manuale istruzioni BST-100. Pag.

AX-100TFR/AX-200 TFR INTRODUCTION 1-1 BEFORE YOUR OPERATION BATTERY OPERATED PHOTOELECTRIC DETECTOR. Warning FEATURES. Caution. Warning.

"Pegaso" wireless alarm system

ACTIVE INFRARED BARRIER

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

Solar Powered Wireless Photobeam Sensors

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

Photobeam 5000 ISC-FPB1-W60QF, ISC-FPB1-W120QF, ISC-FPB1-W200QF. en Installation and Operation Guide

INFRARED MODULATED BARRIERS

Active Infrared Multi Beam Sensors

D-Tect 2 GJD300 Quad PIR Movement Detector

Active Infrared Multi Beam Sensors. R Series

Table of Contents. 1. Mounting Tips... 2

ENFORCER SENSOR MANUAL. Multi-Frequency Quad Photobeam Detectors

FSLIMPRO

This symbol indicates prohibition. The specific prohibited action is provided in and/or around the figure.

COMPANY PROFILE. a A SOLID REPUTATION. a DETAIL IN MANUFACTURING PROCESS. a SICURIT A TRUSTED SUPPLIER

Twin Photobeam Detectors Manual

Photoelectric Beam Detector

Movement Detector GJD 300

Photobeam 5000 ISC-FPB1-W60QS, ISC-FPB1-W120QS, ISC-FPB1-W200QS. en Installation and Operation Guide

mod. ERHSO712 mod. ERRHSO712 ENGLISH CONTROLLER mod. CSRLS MAINTENANCE ADDITIONAL CONTROLS

GJD OPAL RFX WIRELESS 35 METRE EXTERNAL PIR INSTALLATION MANUAL

"Pegaso" wireless alarm system D.I.Y. wireless kit

Safety Photo Beam UL MONITORED DEVICE

DHR3. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer. INSTALLATION INSTRUCTIONS

LZR -WIDESCAN. Motion, Presence, and Safety Sensor for Industrial Doors (US version) DESCRIPTION ENGLISH

D-TECT Dual Tech. GJD360 Triple Technology External Detector

Elite. GJD022 /GJD023 35m External PIR. Multi Beam Lens Data

5800-OD Wireless Outdoor Motion Sensor Installation Instructions

COMPANY PROFILE. a A SOLID REPUTATION. a DETAIL IN MANUFACTURING PROCESS. a SICURIT A TRUSTED SUPPLIER

PHOTOELECTRIC BEAM SENSOR PR-11BE : OUTDOOR 3.3 to 36ft. (1 to 11m) : INDOOR 3.3 to 49ft. (1 to 15m)

PHOTOELECTRIC DUAL BEAM DETECTOR R4222 RECEIVER INDICATORS 1

THE EVOLUTION OF CONTROL APP & CLOUD PORTAL

80 CHANNELS WIRELESS RECEIVER WITH LCD DISPLAY M1.1.1-Hx.x-F1.1-ENG [AN] [SPV] MADE IN ITALY INSTALLATION AND USE MANUAL

SIRA srl. Installation and user manual. Consolle/Digit Remote LCD Annunciator. Remote LCD Annunciator INSTALLATION & USERS MANUAL.

LZR -FLATSCAN SW SAFETY SENSOR FOR FULL- AND LOW-ENERGY AUTOMATIC SWING DOORS. Visit website for available languages of this document.

ACTIV8 ONE OFF. 1 Tips USER S GUIDE COMBINED RADAR OPENING AND ACTIVE INFRARED SAFETY SENSOR. 1 Description. 2 Symbols.

LZR -WIDESCAN OPENING, PRESENCE & SAFETY SENSOR FOR INDUSTRIAL DOORS

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

TITLE SLIDE. FIRERAY2000 EExd OPTICAL BEAM SMOKE DETECTOR. Doc. No: Copyright Fire Fighting Enterprises Ltd.

DH400. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer.

TP4-20 GSM 4 TO 20 ZONES CONTROL PANEL WITH ON-BOARD GSM INTERFACE USER MANUAL EN EN EN /3 EN

Alarm Bell/Control Panel DOGE CT3

INSTALLATION MANUAL SOUNDER MODELS RIALTO L LS X LSX TRIADE L LS QL QLS LIDO L X LS LSX

D296/D297. Installation Instructions Long-Range Beam Smoke Detectors

FIRERAY 5000 range USER GUIDE

LZR -H110. LASER SCANNER FOR BARRIERS & GATES with max. detection range of 5.0 m x 6.5 m (16.5 ft x21 ft) User s Guide

FIRE STROBE 2000 INSTALLATION INSTRUCTIONS

LZR -FLATSCAN SW SAFETY SENSOR FOR FULL- AND LOW-ENERGY AUTOMATIC SWING DOORS

EasyTronic III MANUAL SERVICE

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No &

MULTIGUARD MULTIGUARD USERS MANUAL TYPE S3/240W 26/01/2010

HX-80NRAM. High Mount Outdoor Detector

Intrusion. Outdoor protection perimeter

Operating Instructions

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions.

Fireray Application and. Installation Guide FEATURES. Range metres. 12V to 24V dc operation. Selectable alarm thresholds

Remote Chexit Module (RCM) System. General Information

D-TECT 2 IP. GJD230 IP Motion Detector

/ / 2018

D-TECT 3 IP. GJD260 IP Motion Detector

Original operating instructions Photoelectric safety sensors (safety light curtain / safety light grid) Protected area width (range) 0...

GSM RFID VOICE Alarm System

THE BEST SOLUTIONS FOR OUTDOOR PERIMETER PROTECTIONS

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification

CM-RQE70A PIR REQUEST TO EXIT DETECTOR

Operating Instructions

Janfire Pellet Burner Boiler. for single / double burner management (Version 1.1)

Description. Optex Incorporated

MOBILE CALL GSM Alarm System User s Manual

Leuze electronic. Dimensioned drawing. Electrical connection. Accessories: 150m ISO 9001

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

MVP-D-TEK Vehicle Loop Detector 9 Volts DC to 240 Volts AC. Operating Instructions

SAS908WHB-3-RF/B WIRELESS THERMOSTAT

ELECTRONIC PANEL LRX 2035 ALARM

REDNET INFRARED BEAM SET TYPE RN4/10-25, RN4/25-75 & RN4/ INSTALLATION AND SET UP INSTRUCTIONS

Optical Beam Smoke Detector RK90R - RK90RS

HomeLink Wireless Control System

High Precision Digital Rain Gauge with Indoor Temperature and Humidity

INSTALLATION INSTRUCTIONS. This model is UL Listed product. The comment with *UL-Number are UL s requirements and information for using this product.

Transcription:

Technical manual

INDEX 1 MAIN COMPONENTS Pag. 3 2 MOUNTING SAMPLES Pag. 4 MOUNTING WITH BRACKETS Pag. 5 3 INSTALLATION SAMPLES Pag. 6 4 WIRING Pag. 7 5 CONFIGURATION OF THE OPTICALS Pag. 8 OPTICAL TX Pag. 8 OPTICAL RX Pag. 9 6 SANDOR WS SMA TX MOTHER BOARD Pag. 10 7 SANDOR WS SMA RX MOTHER BOARD Pag. 11 8 SETTINGS & FUNCTIONS Pag. 12 DIP SWITCHES Pag. 12 9 COLOUMN ALIGNMENT Pag. 13 10 CALIBRATION WITH SMA SYSTEM Pag. 14 11 PARALLEL BEAMS CALIBRATION Pag. 18 12 ALARM SENSITIVITY ADJUSTMENT Pag. 19 13 TECHNICAL CHARACTERISTICS Pag. 20 Installation recommendation Verify that the beam tower is fully watertight once the cover and end caps have been correctly filled at the end of the installation. Use the cable glands supplied on the tower for all cabling must pass through the lower end cap using the cable glands supplied. The missed used of proper accessories decrease the IP grade protection of the tower. Avoid any type of obstruction between the transmitter and receiver. Avoid installing the receivers beams in a position where direct sunlight, at the same angle as the receivers beams, can enter directly into optics especially at sunset and sunrise Do not install multiple beams where the transmitter beam can interfere with other receiver beams. It is always better place either transmitter or receivers back to back. POLITEC s.r.l. Manual Sandor HYBRID SMA Ver. 1.2 2

1. MAIN COMPONENTS 3 1 2 4 N Description 5 11 10 6 8 7 1 Aluminium profile 2 IR cover 3 Caps 4 Opticals TX & RX 5 Terminals card 6 Mother board 7 Battery 3.6 V 19 Ah 8 Wireless trasmitter position 9 Power supply 12Vdc 10 Thermostat board 11 Power supply board 3,6 V 9 POLITEC s.r.l. Manual Sandor HYBRID SMA Ver. 1.2 3

2. MOUNTING SAMPLES Pole mounting with SAN/PL Wall mounting with SAN/SD Wall mounting with SAN/PL POLITEC s.r.l. Manual Sandor HYBRID SMA Ver. 1.2 4

MOUNTING WITH BRACKETS Insert the bracket on the back Pole mounting with SAN/PL Diameter pole max 48 mm Wall mounting with SAN/PL Wall mounting with SAN/SD N.B.: we recommend the use of the brackets SAN / PL on the wall when you place the protection of gates (windows, doors,...) along the wall to avoid small obstacles (hinges, edges of window sills,...) that could create signal attenuation. POLITEC s.r.l. Manual Sandor HYBRID SMA Ver. 1.2 5

Standard perimeter protection: 3. INSTALLATION SAMPLES In the case of overlapped barriers: TX4 RX4 TX3 RX3 TX TX2 RX2 RX TX1 RX1 RX4 TX4 RX3 TX3 RX RX2 TX2 TX RX1 TX1 POLITEC s.r.l. Manual Sandor HYBRID SMA Ver. 1.2 6

4. WIRING MOTHERBOARD TX or RX + - POWER SUPPLY BOARD 3.6V 12 Vdc THERMOSTAT BOARD + - 220 Vac POLITEC s.r.l. Manual Sandor HYBRID SMA Ver. 1.2 7

5. CONFIGURATION OF THE OPTICALS OPTICAL TX TEST LED TAMPER TEST BUTTON TX1 TX2 TX3 TX4 TX5 TX6 1 2 3 4 5 6 1 2 3 4 5 6 NB: The address settings as per default. POLITEC s.r.l. Manual Sandor HYBRID SMA Ver. 1.2 8

OPTICAL RX TAMPER LOW SIGNAL LED TEST LED TEST BUTTON RX1 RX2 RX3 RX4 RX5 RX6 1 2 3 4 5 6 1 2 3 4 5 6 NB: The address settings as per default. POLITEC s.r.l. Manual Sandor HYBRID SMA Ver. 1.2 9

6. SANDOR WS SMA TX MOTHER BOARD TAMPER LED ON BATTERY CONNECTION 3,6 V 19 Ah N.B.: When the motherboard is supplied the LED ON will flash. POLITEC s.r.l. Manual Sandor HYBRID SMA Ver. 1.2 10

7. SANDOR WS SMA RX MOTHER BOARD TAMPER INTERVENTION DELAY ADJUSTING DIP SWITCH LED TEST BATTERY LOW (BL) 3,6 V 3,0 V SIGNAL LOW (SL) AND FOR REMOTE (AND) BATTERY CONNECTION 3,6 V 19 Ah ANTIMASK POUTPUT (AMK) - + ALARM TAMPER SUPPLY N.B.: When the motherboard is supplied by battery the TEST LED will flash POLITEC s.r.l. Manual Sandor HYBRID SMA Ver. 1.2 11

The board has Dip Switches to set different functions: 8. SETTINGS & FUNCTIONS DIP SWITCHES 4 DIP SWITCH TX 1 TEST In ON position goes in test for alignment. The TEST LED start blinking. 2 / Not utilized 3 BEAM ON It puts in test all TX during alignment (DIP 1 ON). Test LED fixed ON. 4 BEAM OFF It puts OFF all TX during alignment (DIP 1 ON). Test LED fixed ON. 1 2 3 4 5 6 7 8 9 10 Ex.: Function AND 1-2 with 6 beams 10 DIP SWITCHES RX 1 AND At least 2 optical must be interrupted to give alarm 2 AND 1-2 AND function only for 1st and 2nd beam, usefull in case of growing grass 3 BEAM 3 First 3 RX are active 4 BEAM 4 First 4 RX are active 5 BEAM 5 First 5 RX are active 6 BEAM 6 all RX are active 7 S. LOW FOG disqualification active 8 A. CRAWL 9 AMK / ON - Anti crawling active. In this condition if the first beam (lower) is interrupted for more than 2 seconds, it will generate an alarm, independently of its configuration (i.e. AND) 10 TEST Put in ON activates the test phases ON POLITEC s.r.l. Manual Sandor HYBRID SMA Ver. 1.2 12

1 2 3 4 5 6 7 8 HTR ALLARME TAMPER SUPPLY CONECTOR 8 Not utilized NC Alarm relay NC Tamper relay Possibility to supply the radio trasmitter with 3,0 or 3,6 V CONNECTOR 4 BL BATTERY LOW Low battery indication (negative open collector) SL SIGNAL LOW Fog disqualification (negative open collector) REMOTE AN CONTROL Giving a positive (3,6 V) the AND function is activated Segnalazione di mascheramento data dalla chiusura al negativo di un AMK ANTIMASK open collector. 9. COLOUMN ALIGNMENT For proper alignment once installed barriers orient optical groups of the transmitters and receivers each optical groups in the direction of others. Adjusting horizontally through the manual movement, and vertically through the front screws placed above the lenses. Vertical adjustment Horizontal adjustment POLITEC s.r.l. Manual Sandor HYBRID SMA Ver. 1.2 13

10. CALIBRATION WITH SMA SYSTEM You can improve the calibration through the use of the supplied filter 1) Fold the device by following the folds preset 2) Place the filter in front of the optics TX positioning the two hooks on the pins of the fork optics to effectively search the signal alignment with critical conditions. Simply applying the filter only on the TX, no need to repeat the operation RX. POLITEC s.r.l. Manual Sandor HYBRID SMA Ver. 1.2 14

3) Put the DIP10 in ON on the motherboard to activate the programming mode indicated by the flashing LED test. During this phase the LED will continue to flash. DIP 10 4) Start the alignment of the barrier is on activating the transmitter optics TX TEST, pressing the dedicated button for about 3 seconds until the TEST LED turns orange. ORANGE LED TEST BUTTON POLITEC s.r.l. Manual Sandor HYBRID SMA Ver. 1.2 15

5) Turn the TEST on the corresponding optics receiver by pressing the dedicated button for about 3 seconds until the TEST LED turns orange, the Buzzer and LED alignment go ON. LED ARANCIONE PULSANTE DI TEST 6) Through the TRANSMITTER lens shifts, find the maximum optical alignment based on the BUZZER and LED (high-brightness) of alignment, the 'increase in the frequency of blinking of the LEDs and the whistle of the corresponding BUZZER indicate better ALIGNMENT. 7) By a FULL rotation on the horizontal axis of the RECEIVER optics, you make the SCANNING of the optical signal. 8) Rotating the optical RX find the maximum value of which corresponds to the ALIGNMENT LED (high-brightness) FIXED and whistle CONTINUOUS of the BUZZER. POLITEC s.r.l. Manual Sandor HYBRID SMA Ver. 1.2 16

9) Exit the function by repressing the ALIGNMENT TEST button for about 3 seconds on both optics (TX- RX) ensuring that the orange LED TEST is shown in original condition. LED ARANCIONE PULSANTE DI TEST 10) When finished, remove the shade that acts as a attenuator, with the certainty of having found the optimum value. 11) Once the alignment of all the beams is finished, put in OFF the DIP 10 on the motherboard to deactivate the programming mode indicated by the LED turns off. For the next 30 seconds the barrier will sound continuously in case of alignment not effective or interruption of a beam; correct the orientation of the columns so that the buzzer emits no longer any sound. N.B.: SE IL LED DI TEST CONTINUA A LAMPEGGIARE VELOCEMENTE DURANTE IL NORMALE FUNZIONAMENTO SIGNIFICA CHE ESISTE UNA FONTE DI DISTURBO INFRAROSSO ( ALTRA BARRIERA, FOTOCELLULA CANCELLO, ) CHE NON PERMETTE IL CORRETTO FUNZIONAMENTO DELLA BARRIERA. POLITEC s.r.l. Manual Sandor HYBRID SMA Ver. 1.2 17

11. PARALLEL BEAMS CALIBRATION Put TEST optics TX1 and RX1 and proceed with the calibration as previously explained. Put TEST optics TX2 and RX2 and proceed with the calibration as previously explained. Put TEST optics TX3 and RX3 and proceed with the calibration as previously explained. Put TEST optics TX4 and RX4 and proceed with the calibration as previously explained. N.B.: During the alignment phase of a transmitter the other TX are switched off automatically. POLITEC s.r.l. Manual Sandor HYBRID SMA Ver. 1.2 18

12. ALARM SENSITIVITY ADJUSTMENT You can set the barrier for HIGH sensitivity as crossing fast (running) or LOW as slow ( walking). By adjusting the potentiometer counterclockwise to increase the alarm delay up to 500ms. In this condition ensures the alarm of a person walking through the barrier, with the advantage of excluding the possibility of any false alarms such animals. Adjusting the potentiometer clockwise to decrease the alarm delay up to 50ms. In this condition ensures the alarm of a person crossing the barrier running at maximum speed. POLITEC s.r.l. Manual Sandor HYBRID SMA Ver. 1.2 19

13. TECHNICAL CHARACTERISTICS MAX RANGE INDOOR MAX RANGE OUTDOOR ALIGNEMENT TECHNOLOGY SYNCHRONIZATION ADJUSTMENT PHOTOBEAMS SETTABLE OPERATION MODE SETTABLE BEAMS EXCLUSION ANTI-CRAWLING FUNCTION (FIRST BEAM LOW) COLUMN SUPPLY OUTPUT TAMPER OUTPUT OUTPUT DISQUALIFICATION OUTPUT BARREY LOW OPERATING TEMP. PROTECTION GRADE DIMENSIONE PROFILO LXPXH 100 m 50 m SMA tecnology Optical 20 vertical 180 horizontal Pulsed 950nM beams OR - AND RANDOM Yes Yes BATTERY 3,6 V 19 Ah Relè con contatti liberi NC/NO (su RX) Free contact relay (NC NO) on RX (also for TX tamper) Output OC Output OC 25 C / +65 C IP65 60 mm x 60 mm x (da 600 mm a 4000 mm) N Beams Battery life Single battery Double batteries 2 42 months / 4 36 months / 6 24 months 48 months POLITEC s.r.l. Manual Sandor HYBRID SMA Ver. 1.2 20