Ball Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass

Similar documents
STEAM TRAPS

PT15 MATERIAL : DIMENSIONS - Nominal in inches. AVAILABLE SPARES: Disc (Packet of 5) ORDERING INFORMATION: Refer to "HOW TO ORDER" page.

PRODUCTS. Expansion Joints Fire Fighting. Flexible Metal Hoses. Equipments. Insulation Solutions. Steam. Valves. Level Control.

Chapter 2.3: Steam System

ESCO. Committed. Group of Companies. to help conserve Steam Energy

CHAPTER 6. HEATING PRODUCTION EQUIPMENT AND SYSTEMS

Steam Trap Presentation for IDEA Distribution Workshop. Presenter: Joe Radle

YARWAY PROCESS THERMODYNAMIC STEAM TRAPS SERIES 40/40D AND C250/260

Steam trap checking WHY WE NEED TO CHECK STEAM TRAPS METHODS OF CHECKING TRAPS ADVANTAGES AND DISADVANTAGES PRACTICAL DEMONSTRATION

Product. Add Efficiency To Your Steam Investment... Steam Traps Drain Traps Air Vents & Eliminators Accessories Piping Assemblies Replacement Kits

C. B. Trading Corporation

Silhouette. Feedwater Heater. Boiler Feedwater

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

MFP14 Automatic pumps for condensate and other industrial fluids

Our Know-How. Your Peace of Mind. Steam Solutions

MFP14 Automatic pumps. for condensate and other industrial fluids

Liquid Drainers LIQUID DRAINERS

FT600 & FT601* Steam Traps Float & Thermostatic Steam Trap. Float & Thermostatic STEAM TRAPS

THERMODYNAMIC STEAM TRAP

Condensate Pumps Jones Boulevard Limerick Airport Business Center Pottstown PA Tel:

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

Boiler Condensate Return Basics. Presented by Steve Connor February 24, 2016

THE THERMOSTATIC STEAM TRAP

Steam Traps. . Chambered valves such as; bleeding & venting valves and steam traps. Float Valves using a free fl oat

Armstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual

Bringing Energy Down to Earth

LIQUIDATOR UMT-TD Series Thermodynamic

Inverted Bucket Steam Traps. for efficient condensate drainage of industrial and HVAC equipment

Air Vents AV-392. Proven Same proven, free-floating all stainless steel mechanism as used in Armstrong steam traps.

Spray Flow II cc/liter Atmospheric Deaerator. industrialsteam.com

Spray Flow II cc/liter Atmospheric Deaerator. industrialsteam.com

Steam Trap Inspection Methods And Steam Cost Analysis

STEAM CONSERVATION GUIDELINES

TESTING STEAM TRAPS TO KEEP YOUR SYSTEM OPERATING EFFECTIVELY AND EFFICIENTLY

Steam and Condensate Technology. Solutions which are brilliant in their simplicity. combined with a first-class design & consultancy service.

TABLE OF CONTENTS STEAM TRAPS INVERTED BUCKET SERIES PAGE FLOAT AND THERMOSTATIC SERIES PAGE THERMOSTATIC THERMODISC B0 26. How to Select All 107

Efficient Steam System Design

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL

NICHOLSON STEAM TRAP THERMODYNAMIC STEAM TRAPS

Float & Thermostatic Steam Traps for efficient condensate drainage of industrial process and HVAC equipment

Hoffman Specialty General Catalog

INSTALLATION & MAINTENANCE MANUAL FOR QuickDraw

Indholdsfortegnelse. Danvent Air Handling Units SERVICE MANUAL

Model: 1413 Model: 1418 Float-Controlled Condensate Trap, PN 100

Steam Traps and Steam Specialties

1 of 127. Unicron Engineering ULTRASONIC TRAP TESTER UTT 100 CONDENSATE DRAIN VALVES CDV 32

S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions

Water Fuel + Air for combustion Blowdown

Why steam trap survey?

THERMOSTATIC STEAM TRAPS

BOILER HOUSE PRODUCTS GMS

Flo-Rite-Temp Instantaneous Steam/Water Heater

Nitin Ventures FZE. (A Division of Nitin Fire Protection Industries Ltd.)

Economical and simplified solutions that offer quality and optimum steam trap service.

WHY THE REMOVAL OF NONCONDENSABLE GASES AND AIR IS CRITICAL IN A STEAM SYSTEM

The right trap for the right application.

Installation, Operation and Maintenance Guide. Steam Coil Installation, Operation and Maintenance. steam coils

YARWAY NON-REPAIRABLE DRIP AND TRACER STEAM TRAPS SERIES PB, 29, 129Y AND 29S

Steam Conservation Guidelines for Condensate Drainage Steam Trap Sizing and Selection.

Installation and Maintenance Manual Forbes Marshall Bucket Trap FMBT50

THERMODYNAMIC STEAM TRAPS

MODELS N150/300/675/900/1500/2500/2600 INSTALLATION, SERVICING AND MAINTENANCE INSTRUCTIONS

CHAPTER 3 BASIC STEAM CYCLE

Moss MOSS TRAY DEAERATOR ECONOMICAL INDUSTRIAL DEAERATOR SYSTEMS

Flo-Rite-Temp Instantaneous Steam/Water Heater

Tray ST5. Tray Type Deaerator Pressurized.005 cc/liter. industrialsteam.com

UNIVERSAL STYLE STEAM TRAPS WU450 Series

PRESSURE MOTIVE PUMP (PMP) APPLICATIONS

Installation and Maintenance Manual Forbes Marshall Tracer Line Trap FMMST63

Pump & Trap Combinations

Steam Conservation Guidelines for. Drainage. Mead O'Brien (800) LP Steam. Condensate. HP Steam RECEIVER TANK HEATER

Problem Cause Remedial action. Gauge glass There was excess chemical dosage The normal ph recommended was 9.5 to See photo 3 & 4.

DFE T ECHNOLOGY. At Conceptronic, the design and management process for reflow soldering systems is called Dynamic Flow Engineering, or DFE.

THERMODYNAMIC STEAM TRAPS

Product overview. the optimum components for every application

LIQUIDATOR 450 SERIES

Inverted Bucket Float & Thermostatic Radiator Traps STEAM CONTROL PRODUCTS STEAM TRAPS

Boiler. Fire tube Boiler:

FT14 Ball Float Steam Trap (Screwed)

How to Trap: Trap Selection and Safety Factors

How to Trap: Rotating Dryers Requiring Syphon Drainage

Bringing Energy Down to Earth

opening trap 30 mm Space required for Space required for opening trap 30 mm MK 45-1 with flanged ends (to DIN)

Design and Construction Standards SECTION PLUMBING EQUIPMENT

The Ultimate in Distribution Efficiency. Air Eliminator Dirt Separator Low Loss Header Hydraulic Separator

Steam Traps and Steam Trap Testing

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

ClearFire Economizer Model ECF Integral or External. Addendum to manuals CFH and CFV

Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40

How to Trap: Process Air Heaters

Group-1 Agitators. Group-2 Air Conditioning Plant. Group-3 Air Handling Plant / Air Pressurisation System. Group-4 Belts (Conveyor, V & Wedge Belts)

Disc Type Steam Trap TSD-42

Steam Trap BK 45 BK 45-U BK 45-LT BK 46

GESTRA Valves for Pure and Sterile Steam Systems. Intelligent solutions for sensitive processes

STEAM TRAPS FOREST PRODUCTS LIBRARY FOREST RESEARCH LABORATORY OREGON STATE UNIVERSITY. Information Reviewed and Reaffirmed. August No.

TMCI Padovan Evaporators

Semi-Automatic Suction Screen Filters 3"-4 Angle. Service & Maintenance Manual

TECHNICAL. Series 18. Pump Packages

PIPING SYSTEM EQUIPMENTS

Ball Float Steam Trap with Integral Spiratec Sensor and Flanged Connections

Transcription:

Product of Quality Best Performance Ball Float Controlled Steam Traps Auto Drain Traps Float Valve Air Vent Valves Feed Control Valve Drain Control Valve Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass Sonic Soot Blower Plot No: 1, 10th Street, Kamarajar Road, TASS Industrial Estate, Ambattur, Chennai - 600 098, India. Mobile : +919962995721 / Phone : +914426258502 / E Mail: sakthivalves@gmail.com / sales@excelvalves.com Web: www.excelvalves.com

Comparison EXCEL Ball Float Steam Traps with Other Ball Float Steam Traps Characteristics Construction Operation at very low loads EXCEL Ball Float Trap Simple construction, only one moving part, No Hinges Excellent operation at very low loads Other Ball Float Trap Complex construction number of moving and interlinked parts Not Suitable for low and very low loads Water Hammer Pressure Extra Strainer Effect of Dirt No Effect of water Hammer Due to the sturdy Design of Ball Float Suitable for very high pressures like PN160(STEAM) and Pn320 for Gases. As also for every low differentials pressure of 0.01BAR Not Required Required No effect Due to the scraping effect of the plug valve Rotation, preventing any such Deposition on the outlet valve seat Not Suitable in Application Involving Water Hammer Available Upto 32Bar only, does not operate at very low pressure Dirt Deposition on Outlet seat causes continues leakage of Steam Performance Checking Back pressure Easily possible through check valve Works even at 95% back pressure, Hence also suitable for condensate recovery Requires special kit to check the performance Does not work at back pressures more than 60% of the inlet pressures Comparison EXCEL Ball Float Steam Traps with Inverted Bucket Steam Traps Characteristics Operation Internal Arrangement Air Venting Back Pressure Differential Pressure Connections Failure Position Excel Ball Float Trap Continuous Discharge Only one moving part Excellent Air Venting even at very low pressures Works at even 95% back pressures Works at very low Differential pressure of 0.01Bar Horizontal or Angular Normally Closed Inverted Bucket Trap Intermittent Discharge No. Of Hinges and levers Poor air venting ability at low pressures Works only at 50% back pressures Not suitable for very Low Low Pressure Differential Horizontal or Vertical Normally Open Pressure Range Available up to 160Bar Not suitable for very high pressure Comparison EXCEL Ball Float Steam Traps with Thermo Dynamic Steam Traps(TD) Characteristics Operation Resistance to wear Back Pressure Pressure Effect of Dirt Condensate Recycling Maintenance Excel Ball Float Trap Continuous Discharge No. Steam Consumption for operation Very Good Can operate at 95% Back Pressure Suitable for very low pressure Application No Effect of Dirt as plug valve gives scrapping effect & Remove dirt from seat Very Much Suitable Negligible TD Intermittent Discharge consumes steam for operation Poor Not suitable for very low loads Not Suitable for pressure below 15PSI Dirt built up on seat starts steam leakage through trap Not Suitable Requires disk/seat lapping frequently

COST OF STEAM TRAP LEAKAGE Table 1 Typical Steam Wastage and annual costs due to leaking steam traps Trap Size Average orifice size in Steam Loss(Kg/H) steam traps (mm) 6 Bar g 14 Bar g 32 Bar g DN15 3.0 8 19 43 DN20 DN25 DN40 DN50 5.0 24 53 119 7.5 55 121 270 10.0 98 214 478 12.5 152 335 747 Example A process plan has 30 steam traps of which 10% fail annually. The average trap size is DN20 and the steam pressure is 14 Bar g. The plant runs 24 hours a day, 7 days a weeks for 50 weeks a year = 8400 hours a year Average number of traps failing over a year (10% of 30 ) = 3 Traps From the chart, the steam loss per trap = 53 Kg/H Steam loss per year for the total plant = 3 x 53 x 8400 tonnes per annum Steam Wasted each year = 1336 Tonnes. The cost of overlooking leaks: If the overall cost of steam for this plant were Rs.750 ($ 12.5) per tonne, using coal as fuel the direct cost of ignoring these leaking steam traps would be INR. 10Lakhs($16660) each year. FLOAT CONTROLLED STEAM TRAP(IBR & NON IBR) & AUTO DRAIN TRAP Increasing level opens and decreasing level closes the outlet proportionately, Independent of pressure and temperature, fluctuations. Very simple operational check and air venting possible through stainless steel check valve. The simple & Sturdy design of rotary valve assures you of the reliable and trouble free operation of trap without any steam / air leakage. Pressure Range Vacuum to 320 kg/cm2 Desingned for outstanding performance Simple and sturdy design End Connections 15 NB to 100 NB Welded / Flanged / Screwed. Media Steam, Compressed air, Compressed Gases Discharge Capacity Upto 48000 kg/hour Excel ball float controlled units are of continuous discharge type and discharge the condensate proportionate to the rate of accumulation. These units can handle high starting load and are also suitable for very low as well as very high loads. These units can be fitted with high floats for media with density less than one

WHAT MAKES Excel TRAPS SO IDEAL FOR YOUR APPLICATION? AUTOMATIC AIR VENT VALVE Only one moving part. Simple system, working parts manufactured from high grade corrosion resistant stainless steel. Insensitive to contamination. Extremely long working life. Extremely low maintenance. Proportional control action. Independent of pressure and temperature fluctuations. Impact free and silent condensate discharge in exact quantity. No whirlpool effect, consequently no loss of steam. Can work even at 95% back pressure. Can work at very low differential pressure i.e. at 0.01 kg/cm2 For Liquid Lines Excel ball float type vents are designed for automatic venting of air or gas from any liquid. The presence of gas in casing lowers the float and opens the outlet Pressure Range Upto 63 kg/cm2 End Connections 15 NB to 200 NB Flanged / Screwed / Welded Air Venting Capacity Upto 1250 nm3/h Installations At highest point of equipment with vertical inlet from bottom Application For venting of Water / Oil pipe lines, storage tanks and other process equipments. LEVEL CONTROL VALVE AS FEED CONTROL Pressure Range Upto 63 kg/cm2 End Connections 15 NB to 200 NB Flanged / Screwed / Welded Air Venting Capacity Upto 1250 nm3/h Installations At highest point of equipment with vertical inlet from bottom Application For venting of Water / Oil pipe lines, storage tanks and other process equipments.

DRAIN CONTROL VALVE THERMODYNAMIC STEAM TRAP Excel offers a supreme quality range of Ball Float Auto Drain Trap / Liquid Drainers for moisture removal. Simple and reliable in operation, designed with simple float mechanism from high grade corrosion resistant material, which guarantees the smooth separation of moisture from compressed air or pressurized gases with absolutely zero air / gas leakage, also available in stainless steel body. Specifications The plug valve type discharge orifice of Excel Traps ensures safe, efficient & maintenance free operation. Available for very low pressure as low as 0.01 Bar & for high pressure up to 315 Bar Can be used for compressed air & pressurized gases like Oxygen, Hydrogen, Nitrogen, CO, CNG, Natural gas etc. Size - 15mm to 100mm End Conn - Screwed / Socket Weld End / Flanged Dimensions Size(NB) 15 15 15 A 76 75 125 B 35 35 48.5 A/C C 48 48 48 D ½ BSP 3/4 BSP 1 BSP E 16 20 20 SAFETY VALVE CONDENSATE PUMP Applications IBR NON IBR

FLASH VESSEL Excel offers specially designed Flash Vessels to recover the maximum Flash Steam from the condensate. The inbuilt Steam Trap arrangement gives better condensate removal and eliminates requirement of Trap Module hence the saving in space and cost. MOISTURE SEPARATOR Excel high efficiency moisture separators are specifically designed for the extraction of liquid particles from air/gas flow. A rotary motion is imported to the air/gas flow by means of a guiding device with a high circulatory velocity. The Particles, water droplets contained in the air/gas are flung on to the separator wall by centrifugal force and are collected at the bottom. The cleaned dry air/gas leaves the separator through a central dip tube. The collected moisture at the bottom of separator casing is automatically drained by Excel Auto drain trap The collecting chamber is fitted with a cover plate which prevents the separated moisture being picked up again and carried forward. Excel moisture seperators cannot become clogged and their performance remains constant with a Uni-formly/low pressure drop Baffle Type Pressure Range Up to 63kg/Cm2 Sizes 40NB to 250NB. Flanges Media Steam / compressed air /gas Dimensions Size(NB) 25 40 50 80 100 150 D A 300 350 450 500 700 730 B 85 105 145 175 235 230 D 25 40 50 80 100 150 No. Of Holes 04 04 04 04 08 08

DEAERATOR HEAD Nozzle Schedule Details Condensate Inlet Nozzle Make Up Water Nozzle Flash Inlet Nozzle Vent Nozzle Nozzle Size 100NB 50NB 80NB ½ BSP Description Mixing Head Deep Tube Thermostatic Vent Gasket Mounting Pipe With Flange MOC IS: 2062 SS 316 SS 316 CAF IS: 1239, IS: 2062 STEAM INJECTOR Technical Specifications Body design rating PN25 Maximum Saturated. Steam condition 21 bar g at 230 deg C Heated water temperature 95 deg C For higher capacities, two or more injectors may be fitted in parallel. Sizes 15 to 100 NB End Connections: Male thread of BSPT of NPT standard Butt weld ends SIGHT GLASS Sizes: Flanged DN 15, 20, 25, 40, 50 Operation limits: Max. operating pressure, bar 16 13 11 10 Max. operating temprature, C Test pressure bar 120 200 250 300 24 24 24 24 Applications: The condensate monitor will show the flow actions. It is possible to find out, whether a condensate discharger is defective and permeable to vapor. Condensate monitor are used for the supervision of condensate line or condensate discharger (visual control) : The dividing reinforcement under the inlet and outlet holes provides a hydraulic seal. Condensate, vapor and gas are led around the dividing reinforcement through the hydraulic seal. The specifically lighter medium, vapor, runs over the condensate and presses down the condensate level at the dividing reinforcement.

SONIC SOOT BLOWERS Operation The Excel sonic generators are operated on compressed air and controlled by mean of a solenoid valve and a microprocessor based control systems. The normal isonation cycle is 10 12 seconds after a regular interval of 30-90 minutes, depending on actual soot land. The Excel sonic generator gives an excellent and evenly distributed cleaning effect. In addition, due to it's reverberation it cleans the surfaces against which is is reflected, as well as the small opening and flue gas ducts. Our Range Advantages: Fully Automatic Operations Lower Operation and Maintenance cost Continuous and Effective Cleaning No Mechanical wear and tear of the heating surface Ease of Installation Increased operational Availability of the Equipment Applications Package Boilers Water Tube Boilers Waste Heat Recovery Boilers Super heaters / Economizers / Air Heaters Gas - Gas Heat Exchanger Baghouses Electrostatic Precipitator Fans, Silos, Hoppers & Ductwork Gate Valves Globe Valves Ball Valves Bellow Sealed Valves Non Return Valves Butterfly Valves Forged Valves Disc Check Valves Y Type Strainers Ball Type Flush Bottom Valves Automation Valves Safety Valves Steam Traps Accessories