LET S PLAY IT SAFE. robecco secure center (RSC) G.A.S. inert control (RIC) dust control (RDC) silo automation (RSA)

Similar documents
Minimal maintenance requirements - No consumables and low cost of ownership. Rapid, accurate results - for safe operation of coal handling systems

EXPLOSION PROTECTION MAES SAFETY PRODUCTS & SERVICES

Branch Solution Wood based panel plants. Fire protection solutions for wood based panel plants

LIGNO LIGNO DEDUST PRO EXPERT SYSTEM SOLUTIONS

Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE

Dust Concentration Meter

PRODUCT INFORMATION. GM901 Carbon Monoxide Gas Analyzers CO MEASUREMENT FOR EMISSION MONITORING AND PROCESS CONTROL. In-situ Gas Analyzers

AUTOMATION OF BOILERS USING LABVIEW

THE INDUSTRIAL APPROACH TO DUST MONITORING

Seat Ventilation offers an extensive range of ATEX certified products and is undertaking great efforts to extend this range even further.

FILTERCUBE 2N We set air in motion

Industrial Explosion Suppression Technology

Deep Freezers. Freezers. Biomedical Refrigeration I FR / MF

Safe installations are also cost effective installations

portable gas analyser

METPOINT OCV. e. g. SAFE PROCESS THROUGH MONITORING. FOR CHALLENGING COMPRESSED-AIR APPLICATIONS Pharmaceuticals. Food Chemical Coating

portable gas analyser

ATEX, NOMENCLATURE AND CODING

PRODUCT CONFORMITY CERTIFICATE

Mechanical Vacuum Systems for Secondary Metallurgy Steel Degassing

OPTIBAR DP 7060 Supplementary Instructions

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

NEW LINE BOILER CONTROLLERS

GMS800 FIDOR TOTAL HYDROCARBON ANALYZER CONTINUOUS MONITORING OF HYDROCARBON EMISSIONS

DEEP FREEZERS AND PLASMA STORAGE FREEZERS. Biomedical Refrigeration I FR / MF TECHNOLOGY FOR LIFE

Competence for Safety. ATEX Category 3 Description. Example of a zone division for combustible fluids (gases) and combustible dust

Building Capacities for the Improvement of the Air Quality

INTRODUCTION TO DUSTS AND THEIR EXPLOSIVE PROPERTIES

ADVANCED Series 15P1 17P2 19P2

Ontario Fire Code SECTION 5.10 COMBUSTIBLE DUST PRODUCING PROCESSES. Illustrated Commentary. Office of the Ontario Fire Marshal

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

TR-1 single separator for MQL and dry processes. Explosive dusts from dry processes or MQL extracted directly at the machine and separated safely

gas monitoring system

cgmp, FDA and EHEG Compliant Cleaning Equipment (Pharma Grade)

SUPREMATouch Modular Fire & Gas Detection System

AUTOMATIC FIRE SUPPRESSION SYSTEMS

Refrigeration Dryers TG TI Series

CLEACOM Engineered System Solutions. Established 24/7 technology for the separation of dust and fume during compounding processes

ATEX, NOMENCLATURE AND CODING

ExDetector HC-100. Data Sheet. Gas Measuring and Alarm Systems

55 years of know how on flame monitoring systems from Leipzig

IMR Environmental Equipment, Inc Central Ave. St. Petersburg, FL Phone:

NEW ENGINEERING GUIDELINE (VDI 2263 PART 7) ON DUST FIRES AND EXPLOSIONS PROTECTION IN SPRAY DRYING AND INTEGRATED EQUIPMENT

Industrial fire alarm systems

CERTIFICATE of Product Conformity (QAL1 )

PRODUCT CONFORMITY CERTIFICATE

Series 9000 Total Hydrocarbon Analyzer

ROTO-PACKER The Originals. Made by HAVER. Progress and Quality for the 21st Century HAVER & BOECKER HAVER & BOECKER. Information HAVER & BOECKER

PARTICULATE EMISSION MONITORING

PRODUCT CONFORMITY CERTIFICATE

Prevention of Fires and Explosions in Wood Pellet Facilities. Allen Wagoner, FLAMEX, Inc.

Industrial Fire Detection

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Combustible Dust Hazards- Awareness

Guidelines for Market Surveillance of Equipment for Explosive Environments (Hazardous Locations)

System Overview F300K Compact Flame Scanner. Sensors and systems for combustion engineering.

A Global Leader in Explosion Protection

Snifter ATEX22 VERSION. User Manual. Distributor

Dusty / Dusty Ex Low-Cost Broken Bag Detection

Symphony Plus Combustion instruments

FlowJam S Ex. Bulk Flow Detection. Operating Instructions. SWR engineering Messtechnik GmbH

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

DRYVAC SERIES A new idea for smart pumping

PolyGard Digital Gas Controller DGC-05 RS-485 Bus

Fluid Bed Processor LFP LÖDIGE ALWAYS THE RIGHT MIX

PR / MP I Laboratory / Medicine

EQUIPMENT INTENDED FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

Keller USA, Inc. Filtration of emissions. Capturing & extraction of process emissions. Return of clean air

I.S. Interfaces. for the Process Industry. display. i.s. interface. isolation. temperature. universal

The new generation of Multi-Gas measurement. Dipl.- Ing (FH) Andreas Hester, SIGAS Corp. Environment protection Personal safety Process control

Engineering Guideline. pac- Carriers Type Universal

APPLICATION PROFILE EXPLOSIONS IN CEMENT PLANTS EXPLOSIONS IN CEMENT PLANTS CEMENT PLANT EQUIPMENT WITH HIGHEST EXPLOSION POTENTIAL. Form No.

BINDER Scientific Product Catalog

M-Sens 2. Online-Moisture Meter for Solids. Operating Instructions. SWR engineering Messtechnik GmbH

AQ Translated English of Chinese Standard: AQ WORK SAFETY INDUSTRY STANDARD

BEHN+BATES. Information. Inline Valve Bag Filling Machines

COMPACT FLAME CONTROLLER CFC 1000

INTERNATIONAL STANDARD

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

opti-visor ultra-efficient chiller plant automation Typical specification

Measuring Recording Online Monitoring Regulation Alarming

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

M-Sens 2. Online moisture measurement for solids. Operating Instructions. SWR engineering Messtechnik GmbH PART OF THE ENVEA GROUP

Explosion prevention and explosion protection according to ATEX guidelines. Safe extraction and separation of explosive dust

AVA The expert for. conditioning

Dust Alert 75. *shown with optional external keypad and display

Handling Equipment & Dedusting

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

Betriebsanleitung / Operation manual. Druckwächtereinheit QUINGUARD / Pressurization Controller QUINGUARD

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

Vacuum - The Universal Conveying Force Suction and transportation of powders, liquids and gases

PolyGard 2-channel Gas Controller MGC-03

Refrigerated Compressed Air Dryers

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

The element is closed at one end and open at the other, and it s bolted onto the explosion vent opening on the equipment so that its open end overlaps

COMPACT FLAME CONTROLLER CFC 2000

GSME. Industrial-suited fire gas detectors with multiple semiconductor gas-sensors, integrated signal evaluation and M-Bus interface

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

T.ex Single Gas Detector VISA

KONDRAIN KONDRAIN HP. Condensate Drains. Intelligent condensate drainage up to 350 bar. Rev 03_ EN

Transcription:

LET S PLAY IT SAFE PREVENTIVE EXPLOSION PROTECTION AND AUTOMATION M ONI TOR CO NTR OL PR OTEC T robecco secure center (RSC) G.A.S. inert control (RIC) dust control (RDC) silo automation (RSA) Scan QR-Code to learn more

RISK PREVENTIVE EXPLOSION PROTECTION CO / O 2 MONITORING AND CONTROL Ignition Source Oxygen Explosion Product DUST EXPLOSION HAZARDS exist in Mills Spray Dryers Dryers Filters Dust Collectors Silos Conveyers Separators Dedusting Screens Mixers INGNIATION SOURCES are Smouldering Nests Hot Surfaces Mechanically-Induced Sparks Sparking Electrical Equipment Flames Electrostatic Discharges PRODUCTS are combustible dust in powder-air mixtures Fire and Explosion Risks: Fires and Explosions generate high risks for people, the environment and production installations. The consequences are significant developments of heat and pressure. The fire and explosion safety of an installation is determined by risk factors of the process and products. High temperatures and material product characteristics can develop dangerous smouldering fires in the production process. A proven technology is the use of Carbon Monoxide (CO) analysis for early fire detection and Oxygen (O 2 ) analysis to control the inert atmosphere. This is recommended according to CEN/TR 15221 and VDI guideline 2263/2. Early detection of smouldering fires allows the operators to mitigate fire propagation with help of technical measures. Continuous Carbon Monoxide (CO) and Oxygen (O 2 ) monitoring is essential to ensure prevention against fires and explosions.

robecco secure center RSC robecco secure center is a central fully automatic control system, which guarantees the inert atmosphere during chemical and physical processes. Sensors and actors are connected by the system which prevents effectively dangerous process situations. robecco secure center controls and regulates at the community level or also separately the following components: A: Gas Analyser Systems B: Temperature Sensors C: Inerting Systems D: Valves and Flaps Full automatic monitoring and control system Visualisation of the complete safety and inerting process Fully adaptable at operator CCR User friendly operation Service and Maintenance Monitoring Remote maintenance available Failure indication in clear text messages Trend view and data memory Design according to CEN/TR 15281 and VDI 2263/2 Full Services (Project engineering, Manufacture, Commissioning and Training) Technical characteristics: Connectable at higher control levels Self sufficient system functions without upper PLC control Exact CO 2 - or N 2 - dosing regarding effectiveness and environment Controlling of CO 2 - or N 2 - storage to guarantee the procurement and stock Monitoring of system relevant functionalities of the inerting system, gas analyser systems and temperature sensors Automatic determination of maintenance intervals of single components in dependence of operation duration Cabinet dimensions: 800 x 2100 x 600mm (W x H x D), or also possible to be integrated into the gas analyser cabinets Protection Class: IP55 Installation site: closed rooms without ATEX- Zone Ambient operating temperature: -10... + 40 C Power supply: 110V AC; 230V AC/ 50 60Hz Interfaces: Profibus DP, Profinet, Ethernet Coal grinding systems Process Filter Storage Silos Dryers Gas Dosing Applications Other applications on request

robecco G.A.S. robecco reliably undertakes the measurement of safety-related parameters during the operation of explosive processes. Oxygen, CO and CH 4 measurements are indispensable for operating inert gas units. The use of safety-related parameters is essential for applying preventive explosion control. Taking action requires information on the limiting concentration of Oxygen and the CO/CH 4 concentration of air-dust mixtures. Measuring and control systems have to fulfil certain requirements (ATEX Directive). Measurement systems, monitoring and control units for different gases (gas measurement list on request) and processes Measurement of process safety related parameters Emission measurement systems Gas warning units for stationary gas storages, air monitoring, workplace security Oxygen Sensors Extractive gas sample systems with sample probes and sample lines Flexible sample lines (Lengths, power, heated and non heated version) ATEX certified equipment for explosive areas Full Services (Project engineering, Manufacture, Commissioning and Training) Technical Dates: System dimensions: 800-2400 x 2100 x 600mm (W x H x D) Protection class: IP55, IP65 on request Operating temperature: 0 +35 C Sample probes: with pre-filter, electrically heated, filter cleaning unit Sampling temperature: max. +200 +600 C (on request more) Process pressure at sample probe: 0,5 6bar Sample line: including self-regulated heater and compressed air filter cleaning unit Ambient temperature at sample line: -20 +60 C Lengths of sample line: free confection until 100m ATEX and non ATEX execution Operating modes: continuous or selective Power supply: 110V AC; 230V AC; 50 60Hz Interfaces: Profibus DP, Profinet, Ethernet, Potential Free Contacts Coal grinding systems Process Filter Storage Silos Dryers Kilns Other applications on request

robecco inert control RIC robecco inert control RIC is an automated control system for inerting systems which are operated with CO2 or N2. To reduce limiting oxygen concentrations (LOC) for preventive explosion protection under critical limits it is necessary to purge inert gases like CO2 or N2 into the explosive process atmospheres. robecco inert control offers a complete and flexible solution for inerting systems. Touch panel visualisation and operation System relevant parameter indications Local control and remote control mode Failure indication Reliable performance Integrable in the full automatic control system robecco secure center Full Services (Project engineering, Manufacture, Commissioning and Training) Technical Dates: System dimensions: 800 x (1000-2000) x 400mm (W x H x D); Protection class: IP55, IP65 Ambient temperature: -10... +40 C Power supply: 110V AC; 230V AC; 380 460V AC/ 50 60Hz CPU Controller Monitoring and Operator Display Interfaces: Profibus DP, Ethernet, Potential free contacts Coal grinding systems Process Filter Storage Silos Dryers Other applications on request

robecco dust control (RDC) The operating of a modern filter system without permanent control of dust emissions is currently not conceivable. This is relevant, not only in the view of the responsible authorities, but also the operators can see important advantages. robecco dust control determines in an effective way damages in filter separators. Optimisation of emission and filter monitoring guaranties high productivity. dust sensor Emission and filter monitoring in one device Avoidance of visible exhaust gas plumes Avoidance of product losses Simple erection and installation Simple maintenance of filter installations because of: Early detection of ongoing bag filter damage Location of damaged filter elements Opportunity for specific maintenance actions raw gas clean gas dust content (%) (4... 20 ma) T compressed air dust Filtercontroller RDC100C and RDC200 ATEX Technical Dates: Case: Compact device (integrated operator unit), IP65 Size: 80 x 175 x 65mm (W x H x D), Weight 2,0kg (RDC 100C) Size: 60 x 130 x 400mm (W x H x D), Weight 2,5 kg (RDC 200 ATEX) Sensor: Triboelectric Sensor with variable lengths (30 500mm), IP65 Measuring range dust: 0... 100% / 0... 10 (1.000) mg/m 3 Calibration: by gravimetric reference measurements (for filter analysis not necessary) Monitoring: Graphic display with online diagram (RDC 200ATEX) Media temperature: max. 280 C (higher temperatures on request) Ambient temperature: -20... +50 C, dew point difference: min. +5K Flow velocity: from about 3m/s Analog output: 4... 20mA (galvanic amplifier on request) Digital signals: failure, two free adjustable limit values (0... 100 %) (RDC 100C) Digital signals: 3 potential free contacts (flow/ maintenance, limit value 1 and 2) (RDC 200 ATEX) Power supply: 110V AC, 230V AC / 50 60Hz, 24V DC Power consumption: 5W ATEX Conformity: Device Category 1/3D (RDC 200 ATEX) TÜ V- approved: TA- Air Electro Magnetic Compatibility: conform to EMC- guideline 89/336/EWG and low voltage guideline 2006/95/EG Emission and filter monitoring in Process filter Silo roof filter Dedusting systems

robecco silo automation RSA robecco silo automation controls in a reliable way silo plants to ensure a continuous operation for the production. Periphery equipment like filling stations, weighing units, conveyors, filters and extraction systems are integrated in the control concepts. robecco supports all projects with engineering, commissioning and training services. robecco silo automation RSA includes hardware and software for the complete silo control with adaption to upper PLC s. Software and hardware are optimized adapted on the process and will be adjusted during the commissioning phase. Optionally integrated are following products: robecco G.A.S. robecco secure center RSC robecco inert control RIC robecco dust control RDC robecco silo automation monitors and controls the following processes and equipment: Analyser systems Temperature sensors Filling measurement Pressure sensors Exhaust filters Explosion vents Isolation equipment Filling stations Extraction systems Weighing units Quantity measuring units Inerting systems Earthing systems Services: Technical audits Planning and configuration Project management, Electrical and Mechanical Control solutions and programming Development, construction and installation of electrical components Commissioning service Switching cabinet manufacture Maintenance Spare part supply and After Sales Service Storage Silos for diverse materials Other applications on request

ROBECCO GENERATES QUALITY SAFETY PRODUCTIVITY robecco GmbH Industriepark 17 56593 Horhausen Germany Fon: +49-2687-92626-0 Fax: +49-2687-92626-20 info@robecco.de www.robecco.de