Building Division 201 SE 3 rd STREET (Second Floor) OCALA, FL Phone: (352) BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS

Similar documents
RESIDENTIAL ELECTRICAL INSPECTIONS CHECKLISTS

APPENDIX - L INTERNATIONAL RESIDENTIAL CODE ELECTRICAL

ONE- AND TWO-FAMILY DWELLING ELECTRICAL CODE HANDOUT (2015 Michigan Residential Code Effective February 8, 2016)

BUILDING CODE GUIDELINE FOR MECHANICAL INSPECTIONS

2009 ELECTRICAL CODE REQUIREMENTS

2011 and 2014 National Electrical Code Changes Residential Only

TABLE OF CONTENTS CHAPTER 1 GENERAL RULES CHAPTER 2 WIRING AND PROTECTION... 51

Residential Wiring (2014 NEC) (Homestudy)

A. Connected to the equipment ground B. Bonded to the box C. Connected to nearest water pipe D. Connected to a ground rod

IMPORTANT NOTICE BUILDERS AND CONTRACTORS WORKING IN NORTH RICHLAND HILLS, TEXAS. June 17th, 2016

Residential Wiring (2017 NEC) (Homestudy)

CHAPTER 15 PART IV NATIONAL ELECTRICAL CODE, 2017

Rocky Mountain Chapter IAEI Annual Meeting Northglenn, CO March 18-19, 2004

Chapter 1 General... 5

Instructor: L. Keith Lofland

Building and Safety Division Civic Center Dr, Bellflower, CA, (562) x

Residential Wiring According to 2011 NEC (Homestudy)

TOM BURNS, PLANNING DIRECTOR

Module number 8 provides an on-line, self-paced training seminar on portions of Chapter 14-Fuel Gas, Chapter 25-Ohio Plumbing Code; Chapter 29-Fire

Residential Wiring According to the 2011 NEC

NATIONAL ELECTRICAL CODE (NEC) & NFPA 70E ARC FLASH ELECTRICAL SAFETY

TABLE OF CONTENTS CHAPTER 5 SPECIAL OCCUPANCIES CHAPTER 1 GENERAL RULES... 19

An Owner s Guide to Maintaining a Mobile / Manufactured Home August 2010

2016 CALIFORNIA CODES KITCHEN, BATH & LAUNDRY REMODEL REQUIREMENTS

Habitability Guidelines

Town of Cicero Local Code Amendments

TECHNICAL ARTICLE. Inspecting Existing Dwelling Electrical Systems Using NFPA 73 by Skip Walker September 2009

General Kitchen, Bath & Bedroom Remodeling Notes County of Marin, Building Inspection Division

Spring Test 6 due 04/26/2013

FAQ. (Frequently Asked Questions) What is required to convert my unfinished basement to finished space?

IEC and NCCER Mapping for Year 1

2010 Residential Ques. & Ans.

Chapter 1 General...9 Article 100 Definitions...11 Article 100 Questions Article 110 Requirements for Electrical Installations...

Informational Bulletin on Mobile office Units Prepared by Mark Hilbert May 17, 2017

Electrical Tech Note 107

2017 NEC Presented by: Russ LeBlanc

Inspection Report. 1 Inspection Way Orlando, FL Prepared for: Wanda Figueroa Prepared by: ACF Home Inspections Inc

CONTINUING EDUCATION FOR OREGON ELECTRICIANS. AMERICAN ELECTRICAL INSTITUTE PO Box Spokane, WA

Electrical Systems. Electrical Plans. Electrical Plans. Essential to ensure. National Electrical Code (NES) Consider electrical needs.

TABLE OF CONTENTS. Part I Administrative... 1

Michigan Chapter IAEI Annual Meeting Ann Arbor, Michigan Code Panel Questions December 5 th and 6 th, 2013

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 8/10/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

8. Multi-Family Residential Buildings

Units 2, 3, 4, 5, 6, 8, 9, 10, Electrical Wiring Residential Unit 2 (Unit 5 Fourth Edition)

ll. Consistency Questions

FIRE ALARM: BY OTHERS, IF REQUIRED.

BUILDER S PRE-INSPECTION CHECKLIST

FIRE ALARM: BY OTHERS, IF REQUIRED.

SDEC 2017 Questions, Group 1

The following report was prepared for the buyers of the home and property at 1400 Main St. Anywhere City, Tennessee. The inspection was conducted on

Troy's Home Inspection Services LLC

BALTIMORE CITY RENTAL LICENSE INSPECTION FORM RENTAL LICENSING INSPECTOR GUIDANCE

Public Comment No. 2-NFPA [ Section No ] Statement of Problem and Substantiation for Public Comment. Submitter Information Verification

***DRAFT - NOT FOR FILING***

Photovoltaic (Solar) Array Installation Guide

Electrical Design Guidelines Table of Contents

2009 WESTERN SECTION CODE PANEL QUESTIONS

Montgomery County Land Bank PRE SALE INSPECTION REPORT

CITY OF LOS ANGELES LARUCP ELECTRICAL PLAN CHECK LIST

Code verification sign-off

NEC Study Guide CORRECT: C NEC (A)(1)

Code Compliance Report

TABLE OF CONTENTS CHAPTER 2 WIRING AND PROTECTION CHAPTER 1 GENERAL RULES... 19

.4 Do complete installation in accordance with latest Electrical Bulletins of the local inspection authority.

District 1. 1 Tony Tadysak Craig Mulder

BUILDER S PRE-INSPECTION CHECKLIST

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- ELECTRICAL

INDEX. Page 2 to 7 Electrical Specifications. Page 8 Electrical Schemes: Basement Plan. Page 9 Electrical Schemes: First Floor Plan

Mechanical Systems Submittal Guide

ELECTRICAL - WIRING DESIGN AND PROTECTION SELF INSPECTION CHECKLIST

1710 ANYWHERE DRIVE, MONTGOMERY, AL 36109

Inspection Report. Mr. Happy Homeowner. Property Address: Focal Point Home Inspection Ltd.

Inspecta-Homes 2469 University Avenue West St. Paul MN Ph#: (651)

TABLE LIGHTING POWER DENSITIES FOR BUILDING EXTERIORS ASHRAE Uncovered Parking Areas. Building Grounds. Walkways 10 feet wide or greater

A HOMEOWNERS HANDBOOK

NEC CODE QUESTIONS. Western Section IAEI 103 rd Annual Meeting September 17-19, 2007

Revisions for the 2011 National Electrical Code - Part 1

Maintence/Renewal Report

Montgomery County Land Bank 130 West 2nd Street, Suite 1425 Dayton, OH PRE SALE INSPECTION REPORT

Overview of Significant 2017 NEC Changes

NEC CODE QUESTIONS and ANSWERS Wisconsin Chapter IAEI Green Lake, Wisconsin May 16-18, 2012

Steve Ramsey Home Inspections

Port of Portland Conveying Equipment Guidelines

SECTION 2 NEC REFERENCES SECTION 1 LOW-VOLTAGE AND POWER- LIMITED SYSTEMS...1. CHAPTER 1 GENERAL Introduction...35

Rental Housing Initial Inspection Checklist Community Development Department 208 NW 1 st Ave., Faribault, MN

The one-half hour seminar in module 2 that follows, will complete the remainder of chapter 3, building planning, already begun in module 1.

CODE PANEL QUESTIONS

Axiom Property Inspections

SMALL HOMES COUNCIL - BUILDING RESEARCH COU CIL CIRCULAR SERIES INDEX G4 2 NUMBER ELECTRICAL WIRING

Montgomery County Land Bank 130 West 2nd Street, Suite 1425 Dayton, OH PRE SALE INSPECTION REPORT

Electrical Code Incorporating the 2014 International Building Code as amended

FAIRA TRANSPARENCY REPORTS. November 21, 2016

SW District 1. 1 Tony Tadysak Craig Mulder

SAN JOAQUIN COUNTY ELECTRICAL PLAN CHECK CORRECTION SHEET (209) FAX (209)

Watson Home Inspection Services, LLC.

TABLE 1-E (2017) Effective July 1, 2017

Neil Hewitt Electrical & Air Conditioning P/L

Montgomery County Land Bank 130 West 2nd Street, Suite 1425 Dayton, OH PRE SALE INSPECTION REPORT

2014 National Electrical Code & NFPA 70E/Arc Flash

Rental Housing Inspection Guide

Transcription:

BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS Building Code compliance is the obligation of design professionals and/or contractors. Plan Review and Inspection Guidelines are intended to be used by design professionals and contractors to ensure that construction plans and construction projects, at a minimum, address the code priorities that the City of Ocala Growth Management will be looking at during plan reviews and inspections. These Guidelines are not all inclusive. Additional requirements in the Florida Building Code may also apply to your project. If you need assistance with a code question, please consult the 2017 Florida Building Code or contact the City of Ocala Growth Management at (352) 629-8421. Abbreviations for Code Citations Found on Building Division Forms: Volume Abbreviation 2017 Florida Building Code - Building FBC-B 2017 Florida Building Code - Plumbing FBC-P 2017 Florida Building Code - Mechanical FBC-M 2017 Florida Building Code - Fuel Gas FBC-G 2017 Florida Building Code - Existing Building FBC-EB 2017 Florida Building Code - Residential FBC-R 2014 National Electrical Code NEC 2017 National Fire Protection Association NFPA Mobile Home FAC-15C, MH04-02 Ocala Municipal Code OMC **Electrical Inspection Guidelines based on 2014 NEC General Information for all Permits A. Permit Card FBC 105.7 B. Approved site Plan FBC 107.3.5 C. Approved Complete set of Plans FBC 107.3.1 D. Sanitary Facilities on site FBC 3305.1, FBC P 311.1 Temporary Power Pole: A. Support post to be a minimum 4"x4" pressure treated post with two 2 x 4" x 14' long braces or a 6" round pole, all to be of adequate height and buried to the proper depth. Overhead bracing is not required if service is underground. B. Service drop conductors required to have a minimum 10'or 12 Utility Requirement NEC 230.24B1 or B2 NEC 225.18 vertical clearance. C. Proper riser weather-head installed for overhead services. NEC 230.54, 250.53 D. Conductors to be suitable for the location. NE 310.8 and Table 310.13 E. Meter-can mounted between 3 ½ ' and 5 ½ ' above grade. Utility Requirement F. Service equipment to be suitable for the location. NEC 230.70(A) and 110.3 G. Grounding electrode installed. NEC 250.52 H. Proper identification of neutral and grounding conductors. NEC 200.6, NEC 250.119 I. Service equipment properly bonded with main bonding jumper installed. NEC 250.24, NEC 250.28, NEC250.102 NEC 250.96 J. Receptacles must be GFCI protected and weatherproofed. NEC 590.6, NEC 406.8 K. Minimum #8 AWG CU or #6 AWG aluminum conductors. NEC 230.23(B), NEC 230.31(B)

Construction Electrical Service: A. Support is to be a structurally sound masonry wall. Bldg. Department Requirement B. Meter-can mounted between 3 ½ and 5 ½ above grade. Utility Requirement C. Service disconnect equipment to be suitable for the location. NEC 230.70(A) and 110.3 D. Conductors to be suitable for the location. NEC 310.8 and Table 310.13 E. Grounding electrode installed. NEC 250.52, 250.53 F. Proper identification of neutral and grounding conductors NEC 200.6, NEC 250.119 G. Service equipment properly bonded with main bonding jumper installed H. Receptacles must be GFCI protected and weatherproofed NEC 590.6, NEC 406.8 I. Main disconnect enclosure must be lockable Bldg. Department Requirement NEC 250.24, NEC 250.28, NEC 250.102 NEC 250.96 Rough Electric Underground: A. Direct Burial Conductors and Cables 1. Ensure burial depths of all direct burial conductors comply with NEC NEC Table 300.5 Table 300.5. 2. All direct burial conductors must be rated for direct burial and NEC 310.8, NEC 310.13 suitable for wet locations. 3. Bushings or terminal fittings with integral bushed opening shall be NEC 300.5(H) used at the end of conduit or raceways that terminate underground where conductor or cables transition to a direct burial method. 4. Confirm that all direct burial conductors or cables emerging from NEC 300.5(D)(1) & (4) the ground are protected by enclosures or raceways extending from the minimum cover distance required by Table 300.5 below grade to a point up to 8 above finished grade. 5. Ensure any splices on direct burial cables or conductors are listed for NEC 300.5(E) burial application. B. Underground Raceways 1. Ensure the raceway is listed for underground application. NEC 110.3 2. Ensure the raceway depth complies with NEC Table 300.5 NEC Table 300.5 3. Ensure raceway fill and conductor ampacity for service conductors, NEC 310.15, Chapter 9 and Appendix C feeder and branch circuits conductors comply with: 4. Ensure the sizes and types of all other conductors comply with: NEC Table 310.16 5. All conductors installed in raceways underground, in concrete NEC 310.8, 310.13 slabs or masonry in direct contact with the earth must be suitable for wet locations. 6. Conduits or raceways that are installed underground through which NEC 300.5(G) moisture may contact energized parts shall be sealed. 7. Floor boxes shall be listed specifically for this application and shall NEC 314.27(C) be used for receptacles located in the floor. C. Grounding Electrode System: If a structure is to have electric NEC 250.52(A)(3) installed now or at a later date, then a concrete encased electrode is to be installed in the footing or monolithic slab. (This concrete encased electrode is to be inspected at the footing or monolithic slab inspection and a note placed on the Inspection Information tab of CD-Plus confirming the location of the electrode)

Rough Electric: A. Service: Verify service entry location, size, raceway, conduit-fill, bushings, bonding and grounding. NEC 230, 250, 310,312, 314, Chapter 9 Tables 4 & 5 B. Receptacle Circuits 1. Two 20 amp circuits for small appliances in the kitchen. NEC 210.11(C).1 2. One 20 amp circuit for laundry. NEC 210.11(C).2 3. One 20 amp circuit for bathroom receptacles. NEC 210.11(C).3 4. One receptacle on exterior front and rear of building NEC 210.52(E), 400.6 5. Receptacle spacing - 6' rule in habitable rooms, 2' rule on kitchen countertops, any wall space greater than 2', and any counter space greater than 12", Islands C. General Lighting Circuits 1. Verify all required outlets NEC 210.70, 210.63 2. Maintain proper clearance for clothes closet lighting fixtures. NEC 410.2 3. Confirm bathroom light fixture type and location. NEC 410.10(D) 4. Confirm attic, storage or equipment space lighting outlet and Check all other requirements of NEC 210.52 NEC 210.63, 210.70 receptacle locations. 5. Verify exterior and dwelling unit personnel entrance / exit door NEC 210.70 fixture locations. D. General Wiring 1. All wiring installed and properly supported with no open splices. NEC 334.30, 322.56, 110.14, 300.15 2. Nail protection plating as required. NEC 300.4(A)(1), 300.4(B)(2), 300.4(D) 3. Minimum of 6" of free conductor at each outlet, junction or switch box. NEC 300.14 4. Where NM cable is used with non-metallic boxes, the sheath shall extend not less than 1/4" inside the box/beyond the clamp. NEC 314.17(C) 5. Verify Proper Box Fill. NEC 314.16, Table 314.16(A) 6. Proper application of installed wiring system (MC Cable, NM Cable, SE Cable, etc.). NEC 330, 334, 338 Ampacities 310.16 7. Proper fittings used with raceways and cables. NEC 300.15 8. Conductors shall be insulated. NEC 310.2 9. Raceways shall be complete runs. NEC 300.18 10. Paddle fan outlet boxes must be listed for fan use. NEC 314.27(D), 422.18 11. Protection of attic wiring shall be within 6' of access opening or storage floor area. NEC 334.23, 320.23, 330.23 12. Verify bushing on all raceways containing ungrounded conductors, #4 or larger. NEC 300.4(G) 13. All unused opening in junction boxes and cabinets must be closed. NEC 110.12(A), 408.7, 312.5A 14. Verify ceiling insulation type, if structure receives batt insulation, all wiring will be required to be secured above the trusses to allow FBCEnergy 303.2.3 for installation of insulation. 15. Limited energy (security, sound, intercoms, etc) systems must be listed on the approved plans or a separate permit posted on the site. If the limited energy work is performed under a separate permit, then all work must be completed and inspected prior to full approval of the 208 inspection. (compliance with Ch. 7&8) NEC 720, 725, 760, 770

E. Grounding & Bonding 1. All metal boxes and raceways shall be grounded. NEC 250.80, 250.148, 314.4, 314.40(D) 2. Grounding conductors shall be mechanically connected. NEC 250.80, 250.148, 110.14 3. Metal piping systems, exposed interior structural steel and all metal framing members shall be bonded. NEC 250.104 FBC 2704, FBC-R 3402, 250.122 4. Locate the grounding electrode and if it is connected to the services at this time make note under the Final inspection in CD Plus. Inspector staff only F. Smoke Detectors NFPA 72 2007 Edition 1. Inside and outside all sleeping areas. 11.5.1.1 2. On each floor level, including basements. 3. Must maintain a minimum distance of 36" form supply air grills, bathroom and kitchen doors and ceiling fan blades. 11.8.3.5 4. Must be hard-wired and inner-connected. 11.6, 11.8.5 Semi-Power Release: A. This inspection is requested prior to a Final inspection to release power to a structure for various reasons such as finishes, testing, etc. This inspection can only be added by Permitting Staff. B. Service must be complete including the grounding electrode conductor. C. All open boxes, outlets, switches, etc. are required to be made safe and properly completed or covered up to 8'. D. All wiring and boxes above 8' must be capped off and made safe. E. All Doors and Windows capable of being locked(includes Garage) Final Electrical (With or Without) Power Release A. Services: Require proper working clearances. NEC 110.26, 230.24 1. Overhead Service a. Verify proper weather-head height, riser and support. NEC 230.26-28, 230.54 b. Meter enclosure properly secured. c. Grounding electrode conductor properly sized and connected to electrode. 2. Underground Service a. Service laterals that are not installed by the power utility must comply with the location identification requirements of: NEC 250.50, 250.52, Table 250.66 NEC 300.5(D) b. Conductors must be properly sized and supported in a raceway. NEC 230.31, 230.42 c. Meter enclosure properly secured. NEC 312 d. Grounding conductor properly sized and connected to electrode. NEC 250.50, 250.52, Table 250.66

3. Service entry conductors must be properly sized and the correct NEC Table 310.15(B)(6), Table 310.16, Table type. 310.13(A) 4. Main service disconnect properly sized and secured; and all service NEC 230.70-212, NEC 250 equipment properly bonded. 5. All service equipment must meet or exceed the Available NEC 110.9, 250.53, Table 250.66 Instantaneous Current (A.I.C.) at the point of power delivery. 6. Over-Current devices must be properly identified with proper NEC 110, 240, 312, 408 termination of all conductors and proper conduit fill and conductor protection. 7. Panel schedule is complete and accurate. NEC 408.4 8. Only one neutral conductor per terminal on neutral bar. NEC 408.41 9. Services containing a steel nipple between the meter can and NEC 250.94B4 panel requires a bonding bushing. 10. Arc Fault Protection installed for all bedrooms. NEC 210.12 B. Sub Panels and Disconnects: 1. Proper working clearance per: NEC 110.26 2. Check that enclosures, feeder conductors, over-current devices and circuit conductors are properly sized, identified, terminated and NEC 110, 312, 314, 408 grounded or bonded. 3. Arc Flash Protection NEC 110.16 C. Receptacles: 1. Check condition 2. Open grounds or reversed polarity. NEC 200.11 3. Confirm all spacing: 6' spacing in habitable rooms, 2' spacing on NEC 210.52 countertops, and within 3 of all bathroom sinks. 4. GFCI protection installed where required - bathrooms, kitchens, garages, exterior receptacles, hydro tub if installed, within 6' of NEC 210.8 wet bars, etc. 5. Receptacle installed at exterior front and rear of building. If a screen enclosure is installed, then a receptacle must be installed NEC 210.52(E) outside the enclosure. 6. Receptacle within 25 of all heating and cooling equipment and on NEC 210.63 the same level. 7. Extension rings as required in combustible surfaces. NEC 314.20 8. Arc Fault Protection installed for all bedrooms. NEC 210.12 D. Luminaries (lights fixtures) 1. Condition and support. NEC 410 2. Installed where required or switchable receptacles as permitted. NEC 210.70 3. In closets: fixture type, maintain proper spacing from edge of shelf storage area. No incandescent fixtures with open or partially NEC 410.2, 410.16 enclosed lamps and no pendant fixtures. 4. Exterior fixtures at all egress doors and listed for wet or damp NEC 210.70(A)2, 410.10 location. 5. No hanging fixtures or fans are installed inside the tub/shower zone. Bathroom tub/shower zone is 8 up from and 3 out from the NEC 410.10(D) tub rim or shower stall threshold. 6. Fixture grounding NEC 410.40-46

E. Smoke Detectors NFPA 72 1. Functional test all detectors. Ch. 10, 11.10 2. Required inside and outside all sleeping rooms. 11.5.1.1, 11.8.3.5 3. On each floor level, including basements 11.8.3.5, 11.5.1.1 4. Must maintain a minimum distance of 36" form supply air grills, bathroom and kitchen doors and ceiling fan blades. 11.8.3.5 5. Detectors must be hardwired with battery back-up and be interconnected. 11.6, 11.8.5 6. Detectors within 20' of cook appliances must have silencing capability or be photoelectric type. 11.8.3.5 F. Paddle Fans 1. Properly supported. Boxes to be listed per: NEC 422.18 2. Must be mounted no less than 7'6" above maximum water level of NEC 680, FBC-R 305.1 pools, spas, hot tubs; 8' above flood rim of bathtubs; or 7 above the finish floor in any room. G. Miscellaneous 1. If structure contains gas, ensure gas system is bonded to the NEC 250.104(B) grounding grid. 2. If structure contains copper piping for water, confirm the piping is NEC 250.104(A) bonded. Well / Pump Electric: Inspection code # 202 A. Electric disconnect is within sight and within 50'. NEC Article 100 Definition of "In Sight From" and 430.102(B) B. Proper size and branch circuit breaker or fuses. C. Proper conductors for motor load, voltage drop, type of location and NEC 300.5, 310.16, 430 burial depth. D. Physical protection of circuit conductors. NEC 300.5(D)(1)&(4) E. Re-identify any white conductors used as a "hot" conductor in a NEC 200.7(C)(1) cable assembly. F. Well casing bonded. NEC 250.112(M)