POWERCUBE - CENTRAL EXTRACT SYSTEM

Similar documents
MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation

Apartment Ventilation. "Microbox" Continuous Mechanical Extract Units

MRXBOXAB-ECO3 MRXBOX-ECO3

MRXBOXAB-ECO2 MRXBOX-ECO2

Centrifugal extract and condensation control fans

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR)

Installation and Maintenance

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE

OPUS PLUS TWINFANS COMPACT & POWERFUL, IDEAL FOR LARGER ROOM APPLICATIONS WHILST MAINTAINING LOW NOISE LEVELS.

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

Installation and Maintenance

Unity CV2GIP Decentralised Mechanical Extract Ventilation (dmev) Installation Instructions

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside

Domestic & Commercial Fans

OPUSXBOX - SMALL COMMERCIAL HEAT RECOVERY SYSTEM LOW DEPTH, HEAT RECOVERY UNIT WITH MULTIPLE SPIGOTS AND ECOSMART CONTROLS.

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref.

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

The Silent Range Pure Elegance & Tranquillity. The widest range of ultra quiet silent fans

MRXBOX90 - WHOLE HOUSE HEAT RECOVERY UNIT

PA 500/1100V Ultra Quiet Ventilation Fan

SPLASHPROOF AXIAL EXTRACT FANS USED TO EXTRACT AIR EITHER DIRECTLY TO THE OUTSIDE OR INTO DUCTING UP TO 4m LONG

S ILENT Series INSTALL SILENCE, INSTALL QUALITY OF LIFE. The Quietest Extractors in the World in their Category 26,5

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW

Installation and Maintenance

Ventilation. Axial Fans Centrifugal Fans Low Voltage Fans Shower Fans Commercial Fans Flexible Ducting Fixing Kits External Grilles Hand Dryers

SPECIFICATION casing manufactured from aludip steel in white low energy DC external motor aluminium plate heat exchanger

dmev Unit Quietest dmev available. Discreet, tasteful styling. Single fan for use in all applications.

MRXBOX95AB-WH2 (with automatic summer bypass)

IF IN DOUBT, INSTALLATION SHOULD BE MADE BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH CURRENT WIRING REGULATIONS.

Chrome. Approximately 26 seconds drying time. 1.0kW Automatic Eco Fast Dryer Epoxy Coated. 1.2mm thick steel cover

Installation and Maintenance

Installation and Maintenance

Installation and Maintenance

Residential Carbon Friendly Ventilation SAP Q Eligible. ventilation

MRXBOX95B-LOFT. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Loft Mounting. Installation and Maintenance

Lo-Carbon Sentinel Kinetic Range Overview

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside

CI/SfB (57.7) 1st Edition. Lo-Carbon Response/SELV dmev Unit. A new generation of Lo-Carbon continuous running fans

WHHR Midi & Midi Lite

Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System Installation Instructions

SUNWARM AIR SOLAR PRE-HEAT VENTILATION SYSTEM

BATHROOM EXTRACT FANS SILENT-100 Series

Ventilation and Hand Dryers

Installation and Maintenance

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Installation & Commissioning

The Range HIGHEST INDOOR AIR QUALITY IN NEW HOMES

isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans

HRXD MVHR UNIT Mechanical Ventilation with Heat Recovery.

SPECIFICATION GUIDE. Tel DOMUS VENTILATION

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW

Lo-Carbon Quadra SELV

ONE FAN FITS ALL CYFAN CENTRIFUGAL EXTRACT FAN

CI/SfB (57.7) 3rd Edition WINNER2011. Winners of the Energy Efficiency Initiative 2011 Award with our Lo-Carbon Continuous Ventilation Product Range.

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Bracket

MEV-DC. Continuous Mechanical Extract Ventilation Units Installation and Maintenance. Figure 3. Fixing screw hole.

Lo-Carbon Sentinel Kinetic Range Overview

INTEGRA PLUS ABC. 230V~ 50Hz. Stock Ref. N. Installation and Wiring Instructions IPX2

Technical Data Ducted Three Phase Split System Air Conditioner

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Installation & Commissioning

Lo-Carbon Quadra Centrifugal Fan

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Intake air from outside

Green Line HRX. Mechanical Ventilation with Heat Recovery appliance. Installation and Operating Instructions

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans

HR100R. Mini Air Handling Unit - For Ducted Ventilation With Heat Recovery. Installation and Servicing Instructions

Centrif Duo & Centrif Duo Plus

CREATING A HEALTHY INDOOR ENVIRONMENT POSITIVE INPUT VENTILATION (PIV)

MRXBOX95-WM2H. Mechanical Ventilation Unit with Heat Recovery and Integral Humidistat for Wall Mounting Installation and Maintenance

A GUIDE TO SELECTING THE RIGHT FAN

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Installation & Commissioning

IMPROVING INDOOR AIR QUALITY IN NEW HOMES. MECHANICAL EXTRACT VENTILATION (MEV & dmev)

MRXBOX95-LH1/LH2. Mechanical Ventilation Unit with Heat Recovery for Loft Mounting Installation and Maintenance. Spigot 4.

ECO dmev Decentralised MEV

Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System User / Homeowner Guide

MRXBOX95-WH1 MECHANICAL VENTILATION WITH HEAT RECOVERY

Integra. Integra Plus EC MVHR. Installation & Commissioning. Stock Ref. N EC Integra Plus EC PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT.

IDEO 325 ECOWATT. Counter-flow, high-efficiency heat recovery unit IDEO 325 ECOWATT. Low noise. Heat recovery units. Wireless programmable control

WHHR125DC - Aera. Whole House Mechanical Ventilation with Heat Recovery - MVHR

MEV Ecosmart. Installation and Maintenance. Continuous Mechanical Extract Ventilation Units. 1.0 Introduction

Sentinel. Kinetic MVHR Range. Installation & Commissioning. Stock Ref. N PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT.

Itho Advance heat recovery ventilation unit. comfortable. indoor climate

SLIMAIRE 230V & 12V SINGLE SPEED FANS

CI/SfB (57.7) 2nd edition. Lo-Carbon Quadra

1. Oxygen Master 2. Oxygen Sensor 3. Oxygen Refresh Stand-Alone 4. Touch button controls 4. Oxygen Refresh Built-In 5.

MRXBOX95-WM2. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Intake air from outside

RESIDENTIAL VENTILATION DUCTING SOLUTIONS

CVE ECO 2 Range. System Brochure Continuous Mechanical Extract Ventilation Appendix Q Eligible

(57.7) X. March 2006 PRODUCTS. ... the complete solution

Ventilation Fan Model VFB24ACTH VFB24ADTH VFB24AXTH

MRXBOX95AB-WH1. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Wall Mounting. Installation and Maintenance

Swegon CASA R120. Ventilation unit with rotary heat exchanger HOME VENTILATION

Acoustic solution for MRXBOX95(AB)-WH1 and MRXBOX95(AB)-WM2

TOSHIBA AIR CONDITIONING

Green Line HRX. Mechanical Ventilation with Heat Recovery appliance. Installation and Operating Instructions

Model: Kair Whole House Ventilator Model Number: KHRVWH2000

Small Room Heat Recovery Ventilation

Installation & Operating Instructions

Airflow. Add a little Sunshine to your bathroom

Turbo Inline Fan, White - Non Illuminated Art no.33500

HR100R. Mini Air Handling Unit - For Ducted Ventilation With Heat Recovery. Installation and Servicing Instructions

Installation and Maintenance. OPUS 30 and 60. Duct Mounted ('M' range) Domestic Extract Fans IMPORTANT WARNING

Transcription:

58 POWERUBE - ENTRAL EXTRAT SYSTEM DIMENSIONS Measured in mm TOP A A : 345 B : 280 : 335 : 150 B POWERUBE - ENTRAL EXTRAT SYSTEM PERFORMANE GRAPH For POWERUBE ENTRAL EXTRAT SYSTEM 600 500 400 300 200 100 0 100 200 300 400 500 600 700 800 m 3 /h TEHNIAL DATA MAINS VOLTAGE MODELS Extract Volume : 720 m 3 /h (HIGH) : 220 m 3 /h (LOW) Sound Volume* : See Table Below Voltage : 230-240v A~ Frequency : 50 Hz Wattage : 200W (HIGH) : 105W (LOW) Max. Temp. : 50 º Weight : 10.4 kg (POWERUBE ONLY) Max Pressure : 450 pa FAN OPERATION LASS 1 PRODUT MUST BE EARTHED * : Independent Tests 14-7-2003 Standard : Unit can be wired to operate continuously at low speed with boost via 2 speed switch (AN 812A - not supplied) or from multiple 2 pole (bathroom / en-suite light) switches. Alternatively can be wired to operate single speed on and off at any of the 4 speeds. Timer : Unit is wired to operate continuously at low speed with boost via up to 4 standard remote switches i.e. bathroom & en-suite light switches. This model contains integral relay to eliminate electrical backfeed and 2-25 minutes over-run timer before unit drop back to low speed. Both low and high speeds are selectable from 4 speeds. Humidistat : Unit is wired to operate continuously at low speed with boost via integral humidistat and up to 4 standard remote switches i.e. bathroom & en-suite light switches. This model contains integral relay to eliminate electrical backfeed and 2-25 minutes over-run timer before unit drop back to low speed. Both low and high speeds are selectable from 4 speeds. SOUND LEVELS SPEED EXTRAT WATTS 63 125 250 500 1.0K 2.0K 4.0K 8.0K Lw,dB(Lin) LwA,dB(A) LpA,dB(A) From Lp Trickle 230m 3 /h 105W 30.3 37.7 35.3 27.9 21.8 16.9 17.2 22.8 40.6 30.8 13.3 12.0 Medium 340m 3 /h 117W 33.8 42.3 40.7 34.2 29.0 28.9 19.9 22.8 45.5 37.0 19.5 14.0 Boost / High (Std) 500m 3 /h 135W 42.1 47.8 45.1 39.0 36.6 37.2 28.8 23.8 51.1 43.3 25.8 23.0 Extra High 725m 3 /h 200W 48.5 57.2 53.2 47.5 43.6 48.3 45.8 37.0 60.0 53.6 36.1 34.0

POWERUBE - ENTRAL EXTRAT SYSTEM 59 PRODUT SUMMARY Efficient Extraction for Applications Requiring Multi Room Ventilation Extract Range 720m 3 /h (201 l/s) to 220m 3 /h (61 l/s) Integral Relay For Switching From Up To 4 (Light) Switches (Not Standard Model) Suitable As Whole Flat Extract System (BRE Digest 398) Acoustic Lined For Whisper Quiet Sound Levels Selection of 4 Speeds Single Spigot For Flexible Ventilation Solutions 3 Year On-Site Warranty on All Models ode PW 750 PW 750TST PW 750HTST MODELS AVAILABLE Model ontinuous Trickle - Multi Switch Boost & Timer ontinuous Trickle - Multi Switch Boost, Humidistat & Timer SPEIFIATION & INSTALLATION OVERVIEW onstructed from zintec steel with a white enamel finish, the Powercube offers an ideal ventilation solution to application requiring top class multi-room extraction from one unit. The product is built with a highly efficient double inlet blower and ball bearing motor to BS EN60335. It is also acoustically lined to provide whisper quiet sound levels. The unit extracts from multiple rooms via one 150mm spigot located on the side and exhausts via a 150mm spigot located on the opposite. This design offers the ability to install in lofts, cupboards etc and other locations where it would prove inconvenient to install multiple duct runs. Simply run a 150mm duct along the most suitable route and use T adaptors in to the points. The Powercube entral Extract System is designed to comply with BRE Digest 398. POWERUBE - ENTRAL EXTRAT SYSTEM

60 TRIPLEVENT - ENTRAL EXTRAT SYSTEM DIMENSIONS B D Measured in mm A : 337 B : 294 : 74 D : 121 : 100 A TRIPLEVENT - ENTRAL EXTRAT SYSTEM PERFORMANE GRAPH For TRIPLEVENT ENTRAL EXTRAT SYSTEM Pa 350 300 250 200 150 100 50 0 0 40 80 120 160 200 240 FAN OPERATION TEHNIAL DATA MAINS VOLTAGE MODELS Extract Volume : 240 m 3 /h (HIGH) : 120m 3 /h (LOW) Sound Volume * : 19.0dB (A)@3m(HIGH) : 12.0dB (A)@3m(LOW) Voltage : 230-240v A~ Frequency : 50 Hz Wattage : 90W Max. Temp : 50 º Weight : 3.1 kg (FAN ONLY) Max Pressure : 300 pa Double Insulated * : Independent Tests 14-7-2003 Single Speed : The unit will be activated by one of the separate switches / remote room switches (not supplied). When the switch is turned off, the unit will continue to run at high speed for 2-25 minutes, dependant on the timer adjustment. The fan unit will then switch itself off. Twin Speed : The unit is designed to operate continuously at low speed. High speed is activated by one of the separate switches (not supplied). When the switch is turned off, the unit will continue to run at high speed for 2-25 minutes, dependant on the timer adjustment. The fan unit will then switch back to low speed. Twin Speed Kit : The BAR 240TST operates as the twin speed described above. It comes with the Triplevent unit (TVT 240TST), 10 metre length of 100mm flexible ducting (AN 505B), 3 adjustable airvents (AN 819A) and 1 external fixed louvred grille (AN 410D).

TRIPLEVENT - ENTRAL EXTRAT SYSTEM 61 PRODUT SUMMARY Efficient Ventilation of 2 or 3 separate toilets, bath rooms and en-suites from one unit Extract Rate 240m 3 /h (67 l/s) (BOOST) 120m 3 /h (33 l/s) (TRIKLE) Integral Relay For Switching From Up To 3 (Light) Switches (Not Standard Model) ontinuous Trickle Model Suitable As Whole Flat Extract System (BRE Digest 398) Motor Mounted On Rubber Bushes - Significantly Reduces Vibration 3 Year on-site Warranty on All Models ode TVT 240 TVT 240SST TVT 240TST BAR 240TST MODELS AVAILABLE Model Single Speed - Over - run Timer Twin Speed - ontinuous Trickle with Boost and Over-run Timer Twin Speed - ontinuous Trickle with Boost and Over-run Timer including 100mm ducting, grille and 3 airvents SPEIFIATION & INSTALLATION OVERVIEW The TripleVent is, as its name suggests, designed to extract from up to 3 separate toilets, bathrooms or en-suites. Made from a high gloss ABS, the unit comes in single or twin speed models and is specifically designed for in-line installation. The unit should be installed with loft space and can be mounted on ceiling joists using the bracket supplied, or wall mounted on one of the gable ends. Interconnection to the main unit and the 3 extract points is via 100mm flexible ducting and 3 airvents mounted in the ceiling of the rooms to be ventilated. The ducting (AN 505B) and airvents (AN 819A) are only supplied as part of the BAR 240TST TripleVent Kit. TRIPLEVENT - ENTRAL EXTRAT SYSTEM Extract from the central unit can be made through the roof, gable end wall or soffit as required. Extract is via 100mm flexible (AN 819A) or rigid ducting (AN 531A) with a suitable termination point.

62 QUADVENT - ENTRAL EXTRAT SYSTEM DIMENSIONS Measured in mm 1 A B SIDE A : 345 B : 280 : 335 : 100 1 : 150 QUADVENT - ENTRAL EXTRAT SYSTEM PERFORMANE GRAPH For QUADVENT ENTRAL EXTRAT SYSTEM 600 500 400 300 200 100 0 100 200 300 400 500 600 700 800 m 3 /h TEHNIAL DATA MAINS VOLTAGE MODELS Extract Volume : 720 m 3 /h (HIGH QVT750) : 220 m 3 /h (LOW ALL MODELS) Sound Volume* : See Table Below Voltage : 230-240v A~ Frequency : 50 Hz Wattage : 200W (HIGH) : 105W (LOW) Max. Temp. : 50 º Weight : 12.2 kg (QUADVENT ONLY) Max Pressure : 450 pa FAN OPERATION LASS 1 PRODUT MUST BE EARTHED * : Independent Tests 14-7-2003 Standard : Unit can be wired to operate continuously at low speed with boost via 2 speed switch (AN 812A - not supplied).alternatively can be wired to operate single speed on and off at any of the 4 speeds. Timer : Unit is wired to operate continuously at low speed with boost via up to 4 standard remote switches ie, bathroom & en-suite light switches. This model contains integral relay to eliminate electrical backfeed and 2-25 minutes over-run timer before unit drop back to low speed. Both low and high speeds are selectable from 4 speeds. Humidistat : Unit is wired to operate continuously at low speed with boost via integral humidistat and up to 4 standard remote switches ie, bathroom & en-suite light switches. This model contains integral relay to eliminate electrical backfeed and 2-25 minutes over-run timer before unit drop back to low speed. Both low and high speeds are selectable from 4 speeds. SOUND LEVELS SPEED EXTRAT WATTS 63 125 250 500 1.0K 2.0K 4.0K 8.0K Lw,dB(Lin) LwA,dB(A) LpA,dB(A) From Lp Trickle 230m 3 /h 105W 30.3 37.7 35.3 27.9 21.8 16.9 17.2 22.8 40.6 30.8 13.3 12.0 Medium 340m 3 /h 117W 33.8 42.3 40.7 34.2 29.0 28.9 19.9 22.8 45.5 37.0 19.5 14.0 Boost / High (Std) Extra High (QVT750) 500m 3 /h 135W 42.1 47.8 45.1 39.0 36.6 37.2 28.8 23.8 51.1 43.3 25.8 23.0 725m 3 /h 200W 48.5 57.2 53.2 47.5 43.6 48.3 45.8 37.0 60.0 53.6 36.1 34.0

QUADVENT - ENTRAL EXTRAT SYSTEM 63 PRODUT SUMMARY Efficient Extraction for Applications Requiring Multi Room Ventilation Extract Range (Model Dependant) 720m 3 /h (201 l/s) to 220m 3 /h (61 l/s) Integral Relay For Switching From Up To 4 (Light) Switches (Not Standard Model) Suitable As Whole Flat Extract System On Properties Up To 700m 3 (BRE Digest 398) Acoustic Lined For Whisper Quiet Sound Levels Selection of 4 Speeds All Spigots On Top Side Of Unit For Ease Of Flexible And Easy Installation 3 Year On-Site Warranty on All Models ode QVT 600 QVT 600TST QVT 600HTST QVT 750 QVT 750TST QVT 750HTST MODELS AVAILABLE Model ontinuous Trickle - Multi Switch Boost & Over-run Timer ontinuous Trickle - Multi Switch Boost, Humidistat & Timer ontinuous Trickle - Multi Switch Boost & Over-run Timer ontinuous Trickle - Multi Switch Boost, Humidistat & Timer SPEIFIATION & INSTALLATION OVERVIEW onstructed from zintec steel with a white enamel finish, the QuadVent offers an ideal ventilation solution to application requiring top class multi-room extraction from one unit. The product is built with a highly efficient double inlet blower and ball bearing motor to BS EN60335. It is also acoustically lined to provide whisper quiet sound levels. The unit extracts from multiple rooms via 4 100mm spigots located on the top face and exhausts via a 150mm spigot also located on the top face. This design offers the ability to install in lofts or cupboards alike. The QuadVent entral Extract System is designed to comply with BRE Digest 398. QUADVENT - ENTRAL EXTRAT SYSTEM